Tender For special Repair Of Bldg No P-60 (Chdh Of Arc) And Provn Of Drain From C Coy Cook House To Reflex Shooting Range Of Arc, Happy Valley Shillong Under Ge Shillong
Tender Overview
Project Description
Tender for special Repair Of Bldg No P-60 (Chdh Of Arc) And Provn Of Drain From C Coy Cook House To Reflex Shooting Range Of Arc, Happy Valley Shillong Under Ge Shillong
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-Jul-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 17-Jul-2026 |
| 2 | 17-Jul-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 22-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches in soft/loose soil, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed. |
| 2 | Demolition for Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 3 | Demolition of cement concrete (unreinforced) in ground floors and pavings, drain not exc 15 CM thick below or above GL complete all as specified and directed. |
| 4 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 5 | M&L for providing Hard core of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 6 | M&L for cement concrete 1:3:6 Mix, type C-2, using 40 mm graded crushed stone aggregate, as in foundations, filling and mass concrete complete all as specified and directed. |
| 7 | M & L for Pre-cast cement concrete block masonry using cement concrete, 1:3:6 Mix, type C1 ( using 20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6 , complete all as specified and directed. |
| 8 | M&L for plastering 15mm thick in CM 1:4 on brick or concrete surfacesof walls to be finished even and smooth (without using extra cement) complete all as specified and directed. |
| 9 | M&L for 25mm thick cement concrete 1:2:4 Mix, type B-1, (using 12.5 mm graded crushed stone aggregate), as in surface channels and drains and finishing even and smooth without using extra cement complete all as specified and directed . |
| 10 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 11 | M&L for providing coping, using cement concrete 1:2:4 Mix, Type B0 (using 12.5mm graded crushed stone aggregate) as in coping including necessary form work complete all as specified and directed. |
| 12 | Removing excavated material /soill to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 13 | Returning, filling in including spreading, levelling, watering & well ramming in layers n.exc 25cm of hard/dense soil complete all as specified and as directed. |
| 14 | M&L for reinforced cement concrete 1:1.5:3 Mix, (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and the like as in pavement slab etc. complete all as specified and directed. |
| 15 | M&L for Mild steel TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 16 | Material & Labour for formwork to soffits of suspended slabs such as roof slab not exceeding 200mm thick (Horizontal or sloping) fair finished surfaces of concrete flat complete all as specified and as directed. |
| 17 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strenngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed. |
| 18 | S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strenngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed. |
| 19 | S&F 2nd class HW boarding 20mm thick fixed with nails as in eaves board planed one side with butt joint including dismantling boarding of any description complete all as specified and as directed. |
| 20 | M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top:-(i) Taking out old roof treatment and roughening the same old concrete slab by picking, sweeping clean and washing down with water to remove dust etc.and applying cement slurry @3kg/Sqm(ii) Screed bed or bedding layer of mortar 1:4 in 15 mm thick for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items)(iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986.(iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be less applied over bituminous primer as specified above over a Application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction.(v) Applying one coat of aluminum paint over the APP modified membrance @ 0.11Kg/sqm. |
| 21 | M&L for 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with nails as in ceiling,including dismantling wall and ceilling boards of any description including cover fillets complete all as specified and directed. |
| 22 | Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section of unframed work complete all as specified and as directed. |
| 23 | M&L for 2nd class hard wood plain fillets bullnosed, splayed, chamfered or rounded on one edge or face in section clean sawn, fixed with screws sec are exc 6 sq cm n exc 13 sq cm complete all as specified and directed. |
| 24 | M&L for 2nd class hard wood plain fillets bullnosed, splayed, chamfered or rounded on one edge or face in section clean sawn, fixed with screws sec are exc 3 Sq cm and n exc 6 sq cm complete all as specified and as directed. |
| 25 | M&L for preparation of new wooden surfaces of any description n.exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 26 | Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MD land complete all as specified and directed. |
| 27 | M&L for rendering 10 mm thick on concrete surface in cement mortar (1:6) as backing coat and 5 mm th in CM 1:4 using finishing the surface even and smooth without using extra cement, including mixing only liquid water proofing compound as per manufacturer instruction complete all as specified and as directed on External surface.Note:- WPC shall be measured & Paid separately |
| 28 | M&L for 10mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and as directed. |
| 29 | M & L for rendering 05 mm thick in CM 1:3 on ceiling surfaces of cement concrete and finished the surface even and smooth without using extra cement complete all as specified & directed . |
| 30 | Supply only for water proofing compound (Powder) complete all as specified and directed. |
| 31 | M&L for complete removal of existing treatment from wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over complete all as specified and directed |
| 32 | M&L for preparation of newly plastered external surface of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm overcomplete all as specified and directed. |
| 33 | M&L for Complete removal existing treatment of wall and applying 1mm thick Birla/JK white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified and as directed. |
| 34 | M & L for preparation of new plastered/concrete surfaces of walls, and applying 1 mm thick of Birla/JK white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified and directed. |
| 35 | M&L for preparation of old plastered surfaces of ceiling and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified and directed. |
| 36 | M & L for preparation of old decorated surfaces (plastered or unplastered) and applying two coats of white wash on the surfaces of ceiling complete all as specified and directed. |
| 37 | M & L for preparation of new plastered/concrete surfaces of ceiling, applying three coats of white wash on the surfaces of ceiling complete all as specified and directed. |
| 38 | M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 39 | M&L for preparation of old painted of steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed. |
| 40 | M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded agg) as in plinth protection/path incl finishing even & smooth with using extra cement in, complete all as specified and directed. |
| 41 | M&L for PCC 1:3:6 type C2 (using 20mm graded aggregate) as in surface channels and drains complete all as specified and directed. |
| 42 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 43 | M&L for 25mm thick PCC 1:2:4 type B-0 (12.5 mm graded aggregate) as in levelling coarse of tile flooring etc complete all as specified and as directed. |
| 44 | M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed. |
| 45 | M&L Glazed ceramic colour tiles of size 450 x 300 x 7mm thick (premium/special quality) as in vertical surfaces wall such as dado/ skirting etc. set and jointed with neat cement slurry and pointed in white or colour cement to match with the colour of tile over and including 10 mm thick backing course in cement sand mortar 1:4 complete all as specified and directed. |
| 46 | Demolition of stone slabs and granite laid, bedded and pointed in any mortar of any description or thickness in floors, aprons cills or plateform etc complete all as specified and directed. |
| 47 | M & L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 48 | M&L for rounding to edges of stone slabs one edge, such as in steps cooking plateform, and other similar situation complete all as specified and directed. |
| 49 | M& L for Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and 20 mm thick screed bed in CM 1:3 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed. |
| 50 | M& L for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with and including 10 mm thick baking course in CM 1:4 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed. |
| 51 | M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set jointed and pointed in neat cement slurry in floor with grey cement and pigment over and including 15mm thick screed bed in cement mortar 1:4 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed. |
| 52 | M&L for Pre cast RCC 1:2:4 Mix, type B1 (using 20 mm graded crushed stone aggregates) as in cover slab for soakage well / manhole and similar works supported on walls set in cement mortar 1:6 complete all as specified and directed.Note:- Reinforcement steel shall be measured & paid separately. |
| 53 | S & F 500 litres capacity double layer, rotational molded, polyethylene (white colour), tripple layer water storage tank, ISI Marked (Cylindrical vertical with closed top),colour white , hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including dismantling complete all as specified and directed. |
| 54 | S & F 1000 litres capacity double layer, rotational molded, polyethylene (white colour), tripple layer water storage tank, ISI Marked (Cylindrical vertical with closed top),colour white , hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including dismantling complete all as specified and directed. |
| 55 | S&F in repair for 20mm dia Ball cock valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 2 0 m m - 2 1 0 g m s ) complete all as specified and directed. |
| 56 | Taking down GI tubing 15mm dia and connections including removing to store complete all as specified and directed. |
| 57 | Supply and fix 15 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line complete all as specified and directed. |
| 58 | Refixing only 15mm tubes any grade, to walls and ceilings or laying in floors complete all as specified and directed. |
| 59 | Taking down GI tubing 20mm dia and connection including removing to store complete all as specified and directed. |
| 60 | Supply and fix 20 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line complete all as specified and directed. |
| 61 | Refixing only 20mm tubes any grade, to walls and ceilings or laying in floors complete all as specified and directed. |
| 62 | M&L for Cutting chases, of girth not exceeding 10 cm for concealed water tubing or concealed conduit wiring, etc. in stone / brick / Concrete block masonry wall built in cement mortar and making good, disturbed surface in Cement mortar 1:3 complete all as specified and directed. |
| 63 | S&F in repair 15mm bore stop cock cast copper alloy, fancy type, chromium plated, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed. . |
| 64 | S & F in repair 15 mm bore CP fancy type bib tap long body cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 65 | S & F in repair 15 mm bore CP fancy type 2 in 1 bib tap long body cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 66 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all as specified and directed. |
| 67 | S&F in repair brass chromium plated tubular towel rail 600mm long between the flanges and 20mm dia complete all as specified and directed. |
| 68 | S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 69 | S&F in repair for PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 70 | S & F in repair Vitreous china squatting pan of pattern Orissa Pattern of size 580x 440 mm white with PVC ‘P’ or ‘S’ trap , front or back inlet but excluding flushing cistern and flush pipe including placing in position in floor and embedded in cushion of PCC type E2 ( 1:5:10, using 40 mm graded stone aggregates), and finishing the top surfaces to match with the existing flooring as in repairs (bore 110 mm) complete all as specified and directed. |
| 71 | S & F in repair PVC (Plastic polymer Cistern) valve less, Syphonic action type, flushing cistern of capacity 10 litres, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete all as specified and directed. |
| 72 | S&F in repair sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 73 | S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed. |
| 74 | S&F in repair PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed. |
| 75 | S&F in repair PVC (SWR) vent cowl 110mm dia complete all as specified and directed. |
| 76 | S&F in repairs PVC (SWR) bend with access door of 110mm bore complete all as specified and directed. |
| 77 | S&F in repairs PVC (SWR) bend with access door of 75mm bore complete all as specified and directed. |
| 78 | S&F in repair PVC (SWR) 110mm dia in junction single, (Single T) equal or unequal complete all as specified and directed. |
| 79 | S&F in repair PVC (SWR) 75mm dia in junction single, (Single T) equal or unequal complete all as specified and directed. |
| 80 | S & F in repair 75mm dia of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 81 | Taking down chowkhats or frame with shutter without taking off shutter from the frame area exc 1.50 sqm but not exc 4 sqm each & removing from site complete all as specified and directed. |
| 82 | Taking down chowkhats or frame with shutter without taking off shutter from the frame area not exc 1.50 sqm & removing from site complete all as specified and directed. |
| 83 | Resecuring or easing & adjusting without taking down the shutter of any description area exc 1 Sqm and n.exc 2 Sqm in same opening complete all as specified and directed. |
| 84 | S&F MS flat iron such as small articles for hold fast and similar work complete all as specified and directed. |
| 85 | M&L PCC (1:2:4) type B1 (20mm graded Aggregate) for fixing hold fast complete all as specified and directed. |
| 86 | Supply and fixing 2nd class HW plain solid straight chowkhats/frame wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 87 | Supply and fixing 2nd class HW 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares (without sash bars ), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 88 | Supply and fixing 2nd class HW 35mm thick plain framed panelled shutters (any number of panels), with panel of timber flats on both sides or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats complete all as specified and directed. |
| 89 | Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed. |
| 90 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 91 | Supply and Fix Factory made Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 92 | Supply and Fix Factory made Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed. |
| 93 | S&F in repair stainless steel decorative pattern holder/end brackets suitable for drapery rod of 25 mm dia complete all as specified and directed. |
| 94 | S&F in repair stainless steel decorative pattern end support suitable for drapery rod of 25 mm dia complete all as specified and directed. |
| 95 | S&F in repair 25 mm dia stainless steel drapery rod not less than 1mm thick cut to size and fixed in position, including Standard screw complete all as specified and directed. |
| 96 | M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 97 | Supply and fixing 100mm size butt hinges cold rolled mild steel, medium weight, ISI marked complete all as specified and directed. |
| 98 | Supply and fixing 200mm size MS barrel tower bolt stone enamelled black with bright bolt ISI marked complete all as specified and directed. |
| 99 | Supply and fixing 150mm size MS pressed handle oval type stove enameled block complete all as specified and directed. |
| 100 | Supply and fixing 250mm long MS sliding door bolt, plate type, stove enameled black with bright bolt not less than 12mm dia with and including a min of siz bolt & nuts four on bolt & two on staple,ISI marked, complete all as specified and directed. |
| 101 | S & F 140mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 102 | S & F 300mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 103 | Supply and fixing in repairs 250mm long MS sliding door bolt, plate type, stove enameled black with bright bolt not less than 12mm dia with and including a minimum size of bolt & nuts four on bolt & two on staple, ISI marked, complete all as specified and directed. |
| 104 | Supply and fixing in repair 200mm size MS barrel tower bolt stone enamelled black with bright bolt ISI marked complete all as specified and directed. |
| 105 | Supply and fixing in repair 150mm size MS pressed handle oval type stove enameled block complete all as specified and directed. |
| 106 | S & F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples comlete all as specified and as directed. |
| 107 | S & F in repairs Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples comlete all as specified and as directed. |
| 108 | S&F 3 mm thick sheet glass quality and glazing fixed to aluminium frame exc 0.50 sqm complete all as specified and as directed. |
| 109 | S&F 3 mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and as directed. |
| 110 | Forming jambs, etc. to openings CM 1:6 (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and directed. |
| 111 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and dircted. |
| 112 | S&F MS frame work such as grills grating etc, with ends of bar shouldered and or riveled, or forged into spickes framed quared bars and similar work all as specified and directed. |
| 113 | M&L for preparation of new steel surface exc 10cm width or girth and applying of two coat of synthetic enamel paint over a one coat of red oxide primer complete all as specified and directed. |
| 114 | Taking down carefully aluminium/copper conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified. |
| 115 | Material and labour concealed point wiring for one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including suitable size PVC conduit and fittings of medium grade, including pressed steel / PVC terminal switch boxes fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. including cutting chases and making good disturbed surfaces complete all as specified and directed. |
| 116 | All as per item No.115 above but One 3 pin 5 Amps socket out let points on independent board complete all as specified and directed. |
| 117 | All as per item No.115 here in before but 5 Amp socket on same board with other switches complete all as specified and directed. |
| 118 | Material and labour concealed point wiring for power point controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including 20 mm width or higher size PVCconduit and fittings of medium grade, including including pressed steel / PVC terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. including cutting chases and making good disturbed surfaces complete all as specified and directed. |
| 119 | Supply and fixing concealed submain wiring for DBs/ Power Point, two single core, 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked) including 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire including cutting chases and making good disturbed surfaces including taking down old unserviceable one complete all as specified and directed.Note: Two run of main wire, one run of earth wire and one run of conduit shall be measured as single unit. |
| 120 | Supply and fix switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed. |
| 121 | Supply and fix switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified and directed. |
| 122 | Supply and fix socket outlets 2 in 1, 3 pin, 5/6 Amps flush type230/240 V complete all as specified and as directed. (For Same Board only) |
| 123 | Supply and fix switch socket combination 5 in 1 , 6 pin , (6/16 Amps ) flush type controlled by one switch complete all as specified and directed. |
| 124 | Supply & fix ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified. |
| 125 | Supply and fix in repair Bldg security light fittings 35 watts, minimum system lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. |
| 126 | Supply and fix 18 W LED light fitting wall mounted batten 4'ft , extruded aluminium housing, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6000K including necessary connection complete all as specified and directed. |
| 127 | Supply & fix lamp holder, PVC/polycarbonate type with back plate straight or angular suitable for batten fittings complete all as specified and directed. |
| 128 | Supply and fix Vertical distribution board double door MCB TPN 4 way with IP 43 multiphase outgoing suitable for mounting 63 Amps MCB as incomer with Bus bars, Neutral links complete with all accessories including taking down old unserviceable one complete all as specified and directed. |
| 129 | Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 12 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact including taking down old unserviceable one complete all as specified and directed. |
| 130 | Supply and fix MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed. |
| 131 | Supply and fix MCB SPN 40 - 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed. |
| 132 | Supply and fix MCB TPN 40 - 100 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed. |
| 133 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including cutting holes and making surfaces good including white colour paint on wall surface complete all as specified and directed. |
| 134 | Supply and fix Water heater storage type, vertical type wall mounted, electrically operated 230 V, 50 Hz of capacity 50 litres, heating element of 2 KW, Incoly 800 glass coated heating element, 4 year warranty, Inner tank finish and coating with feroglass dry powder technology, 2 units of PVC connection hot and cold water hose, BEE 4 star rated and 05 Year complete product Warranty complete all as specified and directed. |
| 135 | Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion complete all as specified and directed. |
| 136 | Taking down carefully LED battern light fitting and refixing the same complete all as specified and directed. NOTE FOR ALL ITEMSIn case in BOQ any item found repeated and contractor quotes different rate for the same, the rate quoted on lesser side shall only be applicable for payment and no claim whatsoever on this account shall be entertained by the Department. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender