Tender For special Repairs To Roof At Building Number 6, Victoria Road In The Area Of Age B/R (East) Under Ge (North) Pune
Tender Value
44.86 Lakhs
Estimated cost
Bid Submission
10 Jul 2026
2 days left
EMD
89720
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repairs To Roof At Building Number 6, Victoria Road In The Area Of Age B/R (East) Under Ge (North) Pune
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling Single layer Mangalore Pattern or similar tiles in roofing and rubbish off the premises complete all as specified and as directed |
| 2 | Material and labour for roof tiles Mangalore pattern interlocking at side joints, laid dry in roofing complete all as specified and as directed. |
| 3 | All as per serial item No 2.00 here-in-before but using Mangalore pattern roof tiles obtained from dismantling. |
| 4 | Material and labour for ridge or hip tiles to suit Manglore pattern of roofing tiles,bedded and jointed in cement mortar (1:4) etc complete all as specified and as directed. |
| 5 | Dismantling tile battens, spaced at spacing exc 15cm centres to centres fixed with nails complete all as specified and as directed. |
| 6 | Dismantling wooden scantling of section n.exc. 40 sqcm and over at any position all as directed. |
| 7 | Material and labour for Second class hard wood, clean sawn, in scantling as in timber work all as specified and as directed. |
| 8 | S & F of mild steel work as in Roof battens etc and similar work complete using ERW or induction butt welded tubes conforming to IS1161-1998 grade ST.-240, fixed independently shelf tapping screw and in iron cleats etc complete all as specified and directed. |
| 9 | M&L for preparation of New steel surfaces of any description over 10cm girth or width and applying Two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 10 | Dismantling plain or corrugated steel sheeting , any gauge or any thickness, as in roof coverings complete all as specified and as directed |
| 11 | Supply and fix for 0.63mm thick galvanised,plain mild steel sheeting with two corrugations side lap, fixed with 'J' Bolts and washers, in roofs, walls etc with grade of zinc coating 120gms/ Sqm complete all as specified and as directed. |
| 12 | Supply and fix for 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with 'J' Bolts and washers, in roofs, walls etc with grade of zinc coating 120gms/ Sqm complete all as specified and as directed. |
| 13 | M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregates) as in roof kerbs or mud stops rounded or chamfered on edges and as in Coping and similar work complete all as specified and directed. |
| 14 | Material and labour for false ceiling with made up of size 1800mm x 1200mm x 12.5mm thick, tapered edge gypsum board (Gypboard) Plain (conforming to IS 2095-Part 1:2011, Certified board) is then screw fixed to ceiling section with 25mm drywall screws {Material-Carbon steel EN-ISO 7049/50, Finish-Case hardened Grey Phosphating} at 230mm centres on ceiling section & 150mm at periphery of ceiling. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Gyproc Pro-Fill Jointing compound (Conforms to ASTM C475), Gyproc Joint Paper tape fixed on metal grid of hot dipped galvanized steel sections and suspended as per manufacturer's specifications and instructions including dismantling of ceiling board of any description and any thickness including cover fillets/ grid etc. Including dismantling existing complete all as specified and as directed. Make: Gyproc-Saint Gobain or equivalent of Armstrong, Diaken, New Age (ACE) as approved by GE. |
| 15 | Material and labour for plaster of paris decorative cornices/ moulding to the pattern as approved, cross sectional area exceeding 13 Sq.cm and not exceeding 25 Sq.cm and fixed in decorative pattern including preparation of surfaces and applying two coats of oil bound distemper over a coat of primer matching with the colour of ceiling including dismantling existing complete all as specified and as directed. |
| 16 | Material and labour for 12 to 12.50mm thick PVC laminated mineral board false ceiling board of size 600 mm x 600 mm on and including GI powder coated grid work with using 32mm x 23.5mm x 1.5 mm thick main tee, 23.5 mm x 23.5 mm x 1.28 mm cross tee and 23.5mm x 23.5mm x 1.5mm angle fixed to wall for false ceiling including necessary supporting hanger with 2.0mm dia GI wire with 2 layer and 'J' bolts washer nuts for securing frame work to ceiling, suspended @ 120 cm C/C both ways, size of grid shall be 605 mm x 605 mm including dismantling of ceiling board of any description and any thickness including cover fillets/ grid etc. Including dismantling existing complete all as specified and as directed. Make :- Armstrong, Diaken, New Age (ACE). Note: Height of ceiling is above 5 metres. |
| 17 | Material and labour for preparation of old treated plastered or unplastered surfaces of wall by removing all loose paints etc removing nails ,applying birla putty whereever required, smoothen the surface with sand paper and finally applying one coat of acrylic distemper complete all as specified and as directed. |
| 18 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as directed. Note : Old tiles become in contractor property after dismantling. |
| 19 | M&L for double charged vitrified ceremic tiles 10 mm thick (square/rectangular) polished, area of each tile exc. 0.42 sqm not exceeding 1 sqm, in flooring etc , laid over and including screed bed of 15 mm thick cement mortar (1:4) and jointed in neat cement slurry and pointed in white or coloured cement to match dark shade complete all as specified and directed. |
| 20 | -ditto- all as per item No 19 above but in skirting/dado and including 10mm thick screed bed in cement mortar 1:3 complete all as specified & directed. |
| 21 | Material and labour for 18 to 20mm thick granite (of any type) work ( table rubbed and polished) in steps , jambs. pillars, window cills, cooking platforms and any other platform like in cement mortar (1:4) over and including 10mm thick backing coat in cement mortar (1:3), pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting, edge moulding, full curving the edges complete all as specified and as directed. |
| 22 | Taking down cement plaster on brick/ stone walling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 23 | Material and labour for rendering 15mm thick in cement mortar (1:6) on fair faces of on stone wall or brick work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and as directed. |
| 24 | Material and labour for preparation of New plastered wall surface and applying two coats of oil emulsion distemper over a coat of alkali reistant primer over a thin layer (1 to 1.5mm) complete all as specified and as directed. |
| 25 | M/L for 15mm thick cement plaster in CM 1:4 on brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 26 | Dismantling of stone masonry built in cement mortar and in any position complete all as specified and as directed. |
| 27 | M & L stone walling of Random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 including cemet pointing with CM 1:4, complete all as specified and as directed. |
| 28 | M&L Brick work with fly ash bricks, conforming to IS- 12894:2002, Non modular, class designation 75, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 etc complete all as specified and as directed. |
| 29 | Taking down old / perished sub main wiring of any size aluminium conductor cable along with TW batten / PVC conduit and making good the disturbed surface of wall complete all as specified and as directed. |
| 30 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. |
| 31 | M&L for point wiring with two runs of single core FRLS 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable confirming to IS drawn through and including PVC casing capping suitable width complete with all accessories including Modular PVC Flush Box for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm. copper conductor as earth wire connected to common earth dolly and earth in distribution board Complete all as directed all as specified (a) one light/exhaust fan/fan point controlled by one switch.Note: Modular Cover plates will be measured and paid seperately under relavent item. |
| 32 | One light point controlled by one switch Complete. |
| 33 | One 3 pin switch socket outlet, 5 Amps, independent Complete. |
| 34 | One fan & exhaust fan point controlled by one switch. |
| 35 | All as per item No 31 above but with copper conductor cable for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm Complete. |
| 36 | S & F Modular switch one way 6 amp, 01 Module complete all as specified and as directed |
| 37 | S & F Modular switch one way 16 amp, 01 Module complete all as specified and as directed |
| 38 | S&F Modular socket 6A -2/3 pin combined 02 module complete all as specified and as directed |
| 39 | S&F Modular socket 6A/16A -2/3 pin combined 02 module complete all as specified and as directed |
| 40 | Supply & fix modular type fan step regulator,360 Degree rotatable type 120W - 2 Module complete all as specified and as directed |
| 41 | S& F modular white cover plate with frame 3 module complete all as specified and as directed |
| 42 | S& F modular white cover plate with frame 6 module complete all as specified and as directed |
| 43 | M&L complete for ceiling rose surface backelite three terminal 240 volts complete all as specified and as directed |
| 44 | S&F sub main wiring drawing through PVC conduit with two single core 2.5 sq mm and one run of 2.5 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade complete all as specified and as directed. |
| 45 | S&F sub main wiring drawing through PVC conduit with two single core 4.0 sq mm and one run of 4.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade complete all as specified and as directed. |
| 46 | S&F sub main wiring drawing through PVC conduit with two single core 6.0 sq mm and one run of 6.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade complete all as specified and as directed. |
| 47 | Supply and fixing round shape 24 watt Warm White 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 48 | Supply , hanging and connecting up energy efficient, five star rated BLDC as per latest BEE norms, ceiling fan of size 1200mm sweep complete with down rod including provision of flexible copper cable 3 core of size 1.5 sqmm, including writing MES No 2cm height with synthetic enamel black paint call as complete in all respects all as specified and as directed Engineer in charge. |
| 49 | M&L for Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level, connected to galvanised iron or earth lead wire 4.0 mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion. |
| 50 | Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysJul 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender