Tender For Special Repair To Arrest The Leakage/Seepage From Roof At Certain Smqs At Vsn Nagpur
Tender Overview
Project Description
Tender for Special Repair To Arrest The Leakage/Seepage From Roof At Certain Smqs At Vsn Nagpur
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-Jun-2026 | corrigendum No 1 | Date | 13-Jul-2026 |
| 2 | 06-Jul-2026 | corrigendum No 2 | Date | 20-Jul-2026 |
| 3 | 20-Jul-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement plaster on brick or stone wall/ceiling/chajjas etc including raking out joints hacking for key ,scrubbing down with water etc complete all as specified and as directed. |
| 2 | Demolition or brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins,arches,pillars, etc but excluding ashlar facings,dressed stonework and precast concrete articles in cement mortor in 1:4 complete all as specified and as directed. |
| 3 | Material and labour for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 all as specified and as directed. |
| 4 | Material and labour for Brick work with fly ash bricks, straight or corved on plan to any radius in half brick thick walls,built in CM 1:4 complete all as specified and as directed. |
| 5 | Material and labour for rendering 15 mm thick in CM 1:4 over brick or concrete surfaces finished even and smooth without using extra cement and water proofing compound @ 3% by weight of cement (WPC shall be measured and paid separately). |
| 6 | Material and labour for rendering 15 mm thick in CM 1:6 over brick or concrete surfaces, finished fair and even all as specified and as directed. |
| 7 | Supply only approved intergral water proofing compound complete all as specified and as directed. |
| 8 | Material and labour for preparing newly plastered surfaces and applying two coats of acrylic distemper over one coat of primer over two coats of wall care putty complete all as specified and as directed. |
| 9 | Material and labour for applying Two or more coats of 100% Premium acrylic emulsion paint for new surface having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed at any height incuding necessary scaffolding incl preparation of new surface complete all as specified and as directed. |
| 10 | Material and labour for applying Two or more coats of 100% Premium acrylic emulsion paint for old surface having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed at any height incuding necessary scaffolding incl preparation of existing surface |
| 11 | Material and labour for providing PCC 1:3:6 type C2 (using 40mm graded stone aggregate) 75mm thick finishing cement concrete surfaces even and fair without using extra cement as in plinth protection , path etc including necessary form work and provision of joints filled with bitumen, complete all as specified and as directed |
| 12 | Supply and fix 75mm PVC (SWR) bend any radius complete all as specified and as directed. |
| 13 | Supply and fix 75mm PVC (SWR) pipes single socketed in any length with rubber fing joints fixed to walls all as specified. |
| 14 | Supply and fix PVC SWR 75 mm bore pipe single socketed in any length with rubber ring joints fixed to walls / trenches or in floorsall as specified and directed. |
| 15 | Supply and fix in repair PVC(SWR) bend 110mm bore any radius and taking down old one, complete all as specified and directed. |
| 16 | Supply and fix PVC SWR 110 mm bore pipe single socketed in any length with rubber ring joints fixed to walls including taking down old one all as specified and directed. |
| 17 | Taking down carefully existing bitumen tar felt including plaster, concrete/brick coba /tiling from the roof till RCC slab and roughining the surface , and removing the rubbish to a distance exceeding 500m but n.exc 1Km & depositing where directed . |
| 18 | Construction Joints & Cracks treatment: Open the construction joints in the top form V shape groove with approx. 25 mm x 25 mm size. Thereafter apply in-depth waterproofing as a slurry application SmartCare Repair polymer mix with cement (mixing ratio of 1:1).Seal the groove with prepared in SmartCare Repair Mortar. (1:4) and polymer of 10% of weight of cement. (If required grout the joints through PVC injection nozzles fixed @ 1 M c/c, using cement slurry grout with CBX100 or equivalent added @ 250 gm per bag of cement to full saturation etc.) |
| 19 | Screed for Slope correction :-Providing and laying controlled Fibre Reinforced Screed Concrete of M20 grade at all levels and heights specified below using pozzolana Portland cement of grade 53 from approved manufacturer, fine aggregate, 12mm and down size coarse aggregates, necessary shrinkage compensating admixtures approved by Consultants including all leads and lifts, pumping using line pump or boom placer, vibrating/ compaction, scaffolding wherever necessary, curing as directed at all heights and depths as instructed. The concrete shall be laid and the control joints shall be provided for every 16 sqm and all the joints shall be treated with weather resistant elastomeric Hybrid PU sealants to groove with size of 1/3rd of thickness of protection concrete and cured properly. M20 grade with required finish at the top for medium traffic density with a minimum thickness of 50 mm at drain points and a slope of 1:100. (Groove cutting, sealant filling and fibres are mesured under seperate item if required). |
| 20 | Infenia Coating :-Providing and applying the surface with Acrylic primer: Asian Paints or equivalent SC Infinia Primer with a minimum consumption of 0.10-0.15 Kg/Sqm, followed by application of best in class, PUD based, fleece reinforced, weatherproof and waterproofing coating for UV exposed terrace surfaces Asian Paints SmartCare or equivalent Infinia - with consumption of 1.8 kg/Sqm in 3 coats to achieve DFT of 1±0.1 mm. A 50 GSM non-woven needle punched fleece to be embedded during the application of 2nd coat. The cured membrane with reinforced fleece should have the below properties:> Surface Temperature Reduction by Temperature resistance Test : Upto 10 Degrees as per ASTM D4803> Elongation at break >70% as per ASTM D 2370> Tensile strength > 3.5Mpa as per ASTM D 2370 > Crack Bridging Ability> 6 mm as per AS NZ 4548 > Puncture Resistance - > 200 N as per ASTM E 154> Pull-off Adhesion Strength to Concrete >1.5 MPa as per ASTM D7234> Solar Reflective Index > 100 as per ASTM E 1980> Passes Resistance to Dynamic Indentation 5.9 Joules Impact/10 mm Dia @25 deg Celsius as per EOTA: TR-006> Passes Resistance to Static Indentation 200 N Load/ 10 mm Dia. Indentor @25 deg Celsius as per EOTA:TR-007> Passes Resistance to Fatigue Movement Test @ -5 deg Celsius/ 1000 cycles as per EOTA: TR-008> Resistance to low temperature by Dyanmic Indentor @ 0 deg Celsius, 5.9 Joules Impact/10 mm dia. indentor as per EOTA:TR-006 Contd.../- |
| 21 | Contd.../-> Resistance to heat ageing @80 deg Celsius/200 days. Post 200 days the values of membrane performance for dynamic & static indentation tests, tensile strength & elongation values should not exhibit a change of more than 10%> No blistering observed on visual inspection subject to resistance to waterageing test @60 deg Celsius for 180 days> No chalking or flaking observed on exposure to aritificial weathering test in ATLAS Xenon arc reactor for 4200 hrs. The values of membrane performance for tensile strength, elongation at break & crack bridging ability values should not exhibit a change of more than 10% |
| 22 | Supply and fix 40mm dia Bore Packing: (Quantity shall be as per service consultant requirement)Cleaning the surface area to ensure that it is free from oil, grease, dirt and contaminants, all loose materials to be removed and roughen the pipe with wire brush. Apply bonding agent either epoxy resin over roughened pipe and then sprinkled sand over applied epoxy coating when it is green, this is for better adhesion between the pipe and concrete packing. Cost to include packing the gap using water stop tapes, sealing rings and plugs,filling the bore with Non-shrink Smartcare Genral Purpose Grout, sealing the outlet felxible pipe drain collar and application of addition coat of elastomeric PU Magnum coating alround the coller over pipe and concrete surface etc., complete . Rate to include finishing the underside of the bore , pond testing and making the surface good to receive further treatment etc., for following diameters of penetration sizes .Note : Bore packing coming under waterproofing areas are included as part of the waterproofing system same is not measured separately. |
| 23 | Material and labour for repairs to ends of chajja by removing the old loose concrete material, cleaning the reinforcement and finishing the surface apply epoxy base resin of manufacturer pidicrete and choksey and make good with concrete 1:1.5:3 as required to existing broken surface and fair and even in cement mortar 1:3 with epoxy coating and applying two coats of weather proof emulsion paint upto 600mm depth and 100 mm thickness including necessary scaffolding as required at site all as specified and as directed |
| 24 | Material and labour for cutting groove exc 200mm but n exc 250 mm gifth in brick or stone walls and making good the surfaces using PCC 1:2:4 type B0 in CM 1:3 after inserting water proof bituminus membrane complete all as specified and directed. |
| 25 | Taking up/down steel tubing 15 mm bore and connection including cleaning/removal to store, complete all as specified and directed. |
| 26 | Taking up/down steel tubing 20 mm bore and connection including cleaning/removal to store, complete all as specified and directed. |
| 27 | Supply and fix GI water tubes of bore 15 mm dia tubes medium grade with all fittings and fixed complete to walls and ceilling or laid in floors all as specified and directed. |
| 28 | Supply and fix GI water tubes of bore 20 mm dia tubes medium grade with all fittings and fixed complete to walls and ceilling or laid in floors all as specified and directed. |
| 29 | Supply and fix 20 mm dia Stop valves,cast cpper alloy,screwed down,high pressure,with crutch or butterfly handle,screwed both ends for unions and fixed all as specified and directed. |
| 30 | Supply and fix for 20 mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule all as specified and directed. |
| 31 | Supply and fix for 25 mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule all as specified and directed. |
| 32 | Repairs to RCC exposed surfaces by removing the loose material, cleaning the reinforcment with rust remover & applying fosroc's construction solution (renderoc HS XTRA )bonding agent and finishing the same 20 mm thick CM (1:3) with mixing adhesive as direction of manufacturers. |
| 33 | Disconnecting existing PVC water tanks of capacity exc 250 litres & n. exc 500 litres setting aside (or lowering) for repair work and hoisting , reconnecting, refixng in the same position complete all as specified and as directed. |
| 34 | Dismantling existing PVC water tanks exc 250 litres & n. exc 500 litres and removing in store as specified and directed |
| 35 | Supply and fix 500 Ltr Rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed by EIC |
| 36 | Note : The amount against Schedule of Credit on Page No. 28 shall be deducted from the total amount quoted against Sch 'A' while deriving lum Sum for Acceptance. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender