| 1 | Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets,regulators light fittings) and removal from site and making good the disturbed surfaces of (wall/floors/ceiling etc) complete all as specfied & directed. |
| 2 | M&L for point wiring with PVC FRLS insulated multistranded unsheathed cable 1.5 Sqmm size with stranded copper conductor, 1100 volts grade conforming to IS:694 drawn in an existing conduit or as per site requirement making good the surfaces as per existing surfaces with concealed sunk in pressed steel/GI terminal boxes of 1.6 mm thick factory made fixed with brass screws and cup washers including single core stranded copper conductor 1.5 sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in an existing conduit or as per site requirement completed all as specified for the following:- |
| 3 | One light/fan/bell/Exhaust fan/Fresh Air Fan point controlled by one way switch 5 amps. complete all as specfied & directed. |
| 4 | One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board. complete all as specfied & directed. |
| 5 | One 3 pin 5 Amps socket outlet point controlled by one way switch on same board along with other switches. complete all as specfied & directed. |
| 6 | Ditto- all as per item no. 2.02 but one power point with insulated stranded copper conductor cable 2.5 Sqmm single core and PVC insulated FRLS 1100 Volts unsheathed copper conductor 2.5 Sqmm stranded conductor as earth wire connected to dolly complete. Note :- Point wiring drawn in existing conduit or as per site requirement all as specified and directed. |
| 7 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi stranded copper conductor 4.0 sqmm nominal cross sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC concealed conduit of dia not less than 20 mm and conduit accessories concealed in wall (Brick/stone masonary), ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), including PVC insulated multi stranded copper conductor 4.0 sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth duly complete including replastering and making good the surface of wall and painting with existing colour all as specified and directed.(For AC point) |
| 8 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi stranded copper conductor 1.5 sqmm nominal cross sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC concealed conduit of dia not less than 20 mm and conduit accessories concealed in wall (Brick/stone masonary), ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with modular metal flush boxes of size 1.6 mm thick including cover plate with frame of white colour of suitable size as required at site, including PVC insulated multi stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth duly complete including replastering and making good the surface of wall and painting with existing colour all as specified and directed at site for the following: |
| 9 | One light/fan/bell/Exhaust fan/Fresh Air Fan point controlled by one way switch 5 amps. complete all as specfied & directed. |
| 10 | One 3 pin 6 Amps socket outlet point controlled by one way switch on independent board. complete all as specfied & directed. |
| 11 | One 3 pin 6 Amps socket outlet point controlled by one way switch on same board along with other switches. complete all as specfied & directed. |
| 12 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi stranded copper conductor 2.5 sqmm nominal cross sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC concealed conduit of dia not less than 20 mm and conduit accessories concealed in wall (Brick/stone masonary), ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with modular metal flush boxes of size 1.6 mm thick including cover plate with frame of white colour of suitable size as required at site, including PVC insulated multi stranded copper conductor 2.5 sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth duly complete including replastering and making good the surface of wall and painting with existing colour all as specified and directed. |
| 13 | Identifying and rectifying the defects pertains to ceiling fans/exhaust fans/fresh air fans and connects electric circuit, tightening of loose wiring/conduits/ fan capacitors and connection carrying out minor repairs incl blade alignments,screwing/tightening the nuts/bolts/washers etc incl taking down & refixing properly in the same position after repairs, complete all as specified and directed. |
| 14 | M&L for rewinding of ceiling fans of any type and make with super enamelled copper wire of appropriate gauge suiatble for existing make in the workshop including necessary lathe work on shaft, both sides of rewinding covered with high quality varnish and provisions of new nuts/pins including taking out old burnt wind of copper/aluminium complete all as specified and directed. |
| 15 | Ditto- all as per Item No. 8 here-in-before but Air ventilation PVC body/ metal body exhaust fan of size 200/230/300 mm sweep.complete all as specfied & directed. |
| 16 | M&L for overhauling of celing fan 1200mm/1400mm by greasing and oiling,replacement of unserviceable/defective components, except rewinding of starter winding complete all as directed. |
| 17 | Note Sl.No. 8 : (a) Spare parts found unserviceable/defective will be measured and paid separately under relevant item as Supply and fix in repair . complete all as specfied & directed. |
| 18 | Supply in repairs/replacements of following spare of Ceiling fan 1200mm /1400mm sweep of different make :- complete all as specfied & directed. |
| 19 | S&F in repair MS clamp with rubber reel, nuts, bolts, split pin etc suitable for 1200/1400 mm sweep ceiling fan complete all as specified and as directed. |
| 20 | Ball bearing of size 6201/6202 as per sample complete all as specified and directed. |
| 21 | Gun metal bush as per sample. complete all as specfied & directed. |
| 22 | Fan canopy pvc body, white in colour, suitable for existing fan, as per sample and directed. |
| 23 | Ceiling fan blade 1200 mm sweep made up of aluminium body having provision of free size monting nuts/screw all as per requirement at site complete all as specified and directed. |
| 24 | S&F in repair of MS down rod 300/450 mm for fixing of ceiling fan complete all as specified and as directed. |
| 25 | M&L for taking down & refixing and repair of BLDC ceiling fans of any type and make complete including repair/replacement of PCB & ball bearing as requirment and provisions of new nuts and pins for 1200 sweep as per site reqiurement complete all as specified and as directed. |
| 26 | M&L in repair louver shutter of exhaust fan suitable for 300 mm size at the height from 3 mtr to 14 mtr height making good surface of disturbed area complete all as specified & directed.Note: Contractor shall arrange suitable T&P including necessary form work, scaffolding and safety measures to fix properly the exhaust fan shutter complete all as specified and directed. |
| 27 | M&L for Overhauling/Dismantling of defective/rusted Geyser of 25 Ltr capacity, removing inlet/outlet connections, taking out U/S parts by unscrewing bolts and nuts etc. Checking defects and re-assembling the Geyser after refixing serviceable/new parts & cleaning, dicling and refixing only serviceable items and re-installing the Geyser in suitable place/position and connecting inlet-outlet connections & testing complete, all as specified and directed by Engr-in-charge.Note:(a) Items required for replacement of U/S parts will be measured and paid separately under relevant item of sch \\"A\\" ). |
| 28 | Supply in repairs/replacements of following spare parts of geyser storage type of different make for capacity 25 ltrs all as samples as required. |
| 29 | Apparatus assembly duly prewired without heating element and thermostat/thermal cutout.complete all as specfied & directed. |
| 30 | Indication lamp (Green/Red) as per sample.complete all as specfied & directed. |
| 31 | Thermostat as per sample.complete all as specfied & directed. |
| 32 | Heating element 2.0 KW round, square, triangular bottom suitable for 25 Ltrs or as per sample complete all as specified and directed. |
| 33 | Cover outer for geysers suitable for any make/capacity/type of Geysers installed at site duly painted with two quotes with enamel (Deco) paint of colour & shade complete all as specified and directed |
| 34 | Stainless Steel inner tank of 25 Ltrs capacity complete all as specified and directed as . |
| 35 | Bottom and top cover for Geysers suitable for any make/capacity/type of Geysers installed at site duly painted with two quotes with enamel (Deco) paint of colour & shade complete all as specified and directed. |
| 36 | Geyser SS braided pipe of 12 mm (internal dia) suitable for hot/cold water, 600 mm long with nuts and rubber washers complete all as specified and directed. |
| 37 | Taking down DBs,VTPN DBs of any make and type from the site and making good to the disturbed surfaces complete all as specified and directed. |
| 38 | M&L in repair MCB distribution board SPN 8 way with 100 Amps rated bus bar metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet complete all as specified and as directed. |
| 39 | M&L in repair MCB distribution board SPN 12 way with 100 Amps rated bus bar metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet complete all as specified and as directed. |
| 40 | S&F in repair factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-54 & IK 09 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 100 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for 100 Amps, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings including blank spacer for blank space complete all as specified and conforming to IS: 8623 including taking down old DBs all as specified.NOTE :-(a) MCBs/MCCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. |
| 41 | S&F in repair sheet metal enclosure SP and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10 KA breaking capacity complete all as specified and directed. |
| 42 | S&F in repair amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. complete all as specfied & directed. |
| 43 | (i) SP 5 To 63 AMP complete all as specfied & directed. |
| 44 | (iii) SPN 40 to 63 AMP complete all as specfied & directed. |
| 45 | S&F in repair 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN 63-100 amp 4 pole complete all as specified and directed. |
| 46 | S&F in repair RCBO, 230 Volt, 40 Amp, 30mA, 50 Hz, with 10 kA short circuit capacity of double pole for ensuring protection from leakage current, short circuit & over load, complete all as specified and as directed. |
| 47 | Taking down carefully sub main wiring three single run 6/10 Sqmm of any make and type complete all as directed. |
| 48 | Supply, laying and drawing submain wiring in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of multistranded copper conductor PVC insulated, FRLSH, unsheathed cables of 1100 volts grade conforing to IS : 694 of 2010 complete including connection all as specified and directed. Note :- Two runs of IC x 6.00 sqmm (Phase wire and neutral ) and one run of IC x 6.00 sqmm (as earth wire) will be measured as one unit length. |
| 49 | S&F in repair MCCB 100 Amps, 4 Pole 415 volts 16 KA 50 HZ complete all as specified and directed. |
| 50 | S&F in repair MCCB 125 Amps, 4 Pole 415 volts 16 KA 50 HZ complete all as specified and directed. |
| 51 | S&F in repair MCCB 160 Amps, 4 Pole 415 volts 36 KA 50 HZ complete all as specified and directed. |
| 52 | S&F in repair MCCB 200 Amps, 4 Pole 415 volts 36 KA 50 HZ complete all as specified and directed. |
| 53 | M & L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-1 2009, connected to earthing test point, earth lead protected by medium grade 15 mm dia GI pipe connected to main control board and GI pipe medium grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:2:4 B-1 ( including excavation and earth work, disposal of surplus soil to a distance not exc. 50 Mtrs) all as specified and directed.Note:-(a). PCC pit shall be provided at list 500 mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipe and fittings, junction, elbow etc shall be deemed to be included in the unit rate.(b). RCC pit cover shall be of pre-cast RCC 1:2:4, type B-1, 80 mm thick reinforced with XPM weighing not less than 4 Kg/ Sq m in lieu of cast iron cover all as specified or indicated including testing on completion all as specified and directed. |
| 54 | S&F in repair copper wind motor, single phase, 240V suitable for PVC fresh air fan of sweep size 225/ 250/300 mm as per sample given at site complete all as specified and directed. |
| 55 | S&F in repair copper wind motor, single phase, 240V suitable for metallic heavy duty exhaust fan of sweep size 250/300/400 mm as per sample given at site complete all as specified and directed. |
| 56 | S&F in repair single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits complete all as specified and directed. |
| 57 | S&F in repair single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits complete all as specified and directed. |
| 58 | S&F in repair single core PVC insulated cable 4 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits complete all as specified and directed. |
| 59 | S&F in repair single core PVC insulated cable 6 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits complete all as specified and directed. |
| 60 | S&F in repair copper cable flexible 2 core PVC insulated of size 40/.0076 ll complete all as specified and directed. |
| 61 | S&F in repair PVC insulated flexible cable three core copper conductor of size 1.00 Sqmm ISI marked covered with white colour round insulation complete all as specified & directed. |
| 62 | S&F in repair , 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC armoured, PVC sheathed 6 sq. mm nominal cross section, 2 core. complete all as specfied & directed. |
| 63 | S&F in repair LED lights fitting mirror type with high out put diffuser 2 feet, 10 Watt ,220V,AC decorative box type with driver,holder and LED lamp incl. connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 64 | S&F in repair LED lights fitting (3.5 to 4 feet) 1x20Watt ,220V,AC decorative box type with driver,holder incl. LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 65 | S&F in repair 10 watts bulkhead fitting System level efficacy of the Luminary is =>100 lm/watt output, power factor =>0.9, Color Temperature 3000K-6500K, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and as directed. |
| 66 | S&F in repair 35 watts 230 V AC outdoor type with High efficient LED Building security light fitting with high pressure die cast Aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP: 65/66 protected complete with bracket made out of 32 mm GI pipe light grade 1.2 mtr long bend to shape with clamps and fixing bolts all as specified and directed. |
| 67 | S&F in repair 60 watts 230 V AC outdoor type with High efficient LED Building security light fitting with high pressure die cast Aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP: 65/66 protected complete with bracket made out of 32 mm GI pipe light grade 1.2 mtr long bend to shape with clamps and fixing bolts all as specified and directed. |
| 68 | S&F in repair post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified & directed. |
| 69 | S&F in repair new generation energy saving and environmental friendly long life versatile pressure die cast aluminium housing IP-65/66, Led industrial highbay light with high power 80 watt, system efficacy not less than 110 lumen/W,PF ≥ 0.95, colour temperature 5700K–6500K (cool white), including all connection upto ceiling rose complete all as specified and directed. |
| 70 | S&F in repair LED garden light 10 watt, 230 V AC, outdoor decorative type, made of pressure die-cast aluminium housing with corrosion-resistant powder coated finish, complete with high efficiency LED light source, integral electronic driver, adequate thermal management, opal / toughened glass diffuser, IP65 protection against dust and water ingress, suitable for lawns, gardens and pathways, including fixing on suitable base/ pole/ spike, connection with suitable size copper conductor cable, driver and lamp complete, all as specified and directed. |
| 71 | S&F in repair LED flood light 70 watt 230 Volt AC outdoor type with thermal management in multiple optics & equipped with IP 66 protection, with impact and corrosion resistant complete with driver & lamp complete all as specified & directed. |
| 72 | S&F in repair LED flood light 100 watt 230 Volt AC outdoor type with thermal management in multiple optics & equipped with IP 66 protection, with impact and corrosion resistant complete with driver & lamp complete all as specified & directed. |
| 73 | S&F in repair suspended linear LED lights fitting 28/30 W, 5700K , 220V, AC comprises of aluminium extrusion, end caps and clutch wire suspension kit for suspended mounting with driver, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 74 | S&F in repair flat panel light aesthetically designed (2ft x2ft) LED flat panel for surface/recessed mounting type which provides soft-light and glare free symmetrical illumination 35/36 Watt fixture should have minimum efficacy at system level 100 lm/watt output, Colour temperature 4000-6500K, an operating voltage Range of 140-270V including all connection upto ceiling rose complete all as specified and directed. |
| 75 | S&F in repair LED smartglow office lighting recessed luminaire 600mm x 600mm, 36 watt, 220 V AC with built PIR occupancy sensor offering flexibility of auto switching off when the space is not occupied complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 76 | S&F in repair round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. complete all as specfied & directed. |
| 77 | S&F in repair ultra bright compact LED downlighter 12 Watts (round or square shape) with high efficiency LEDs ideally suitable for roof ceiling areas to give glare free light, complete all as specified and directed. |
| 78 | S&F in repair ultra bright compact LED downlighter 15 Watts (round or square shape) with high efficiency LEDs ideally suitable for roof ceiling areas to give glare free light, complete all as specified and directed. |
| 79 | S&F in repair LED Lamp of wattage 09 Watt, 90 lm/W, with PF >0.9 & CRI:80,protection againt high voltage upto 360V, B22 ,230 Volts,50 Hz,complete all as specified and directed. |
| 80 | S&F of Fresh Air Fan made of sturdy Engineering plastic complete with louver shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm sweep, single phase,including cutting of holes in wall/windows for fixing the fresh air fan complete all as specified and directed. |
| 81 | S&F in repair Nut and Bolt full thread hexagon bolt mild steel of size (1/2x6) inch alongwith washer suitable for fixing of Geyser 25 ltrs. complete all as per site requirement all as specified and directed. |
| 82 | S&F in repair hylum sheets 3 mm thick of the following sizes :- complete all as specfied & directed. |
| 83 | Sheet as per sample suitable for mounting one piano switch 5 Amp and one 5 Amp socket duly cut for mounting as above complete all as specified and directed. |
| 84 | Sheet as per sample suitable for mounting one piano switch 15 Amp and one 15 Amp socket duly cut for mounting as above complete all as specified and directed. |
| 85 | Sheet as per sample suitable for mounting three piano switch 5 Amp duly cut for mounting as above complete all as specified and directed. |
| 86 | Sheet as per sample suitable for mounting five piano switch 5 Amp and one 5 Amp socket duly cut for mounting as above complete all as specified and directed. |
| 87 | S&F in repair metal sunken box of the following sizes:- |
| 88 | Box as per sample suitable for mounting one piano switch 5Amp and one 5Amp socket dully cut for mounting all as per sample complete all as specified. |
| 89 | Box as per sample suitable for mounting one piano switch 15Amp and one 15Amp socket dully cut for mounting all as per sample complete all as specified. |
| 90 | Box as per sample suitable for mounting five piano switch 5Amp and one 5Amp socket dully cut for mounting all as per sample complete all as specified. |
| 91 | M&L in repair switch piano flush type 6 Amp SP one way complete all as specified and directed. |
| 92 | M&L in repair switch piano flush type 16 Amp SP one way complete all as specified and directed. |
| 93 | S&F in repair socket outlet 3 pin 6 Amp flush type complete all as specified and directed. |
| 94 | S&F in repair socket outlet 2 in 1,3 pin 6/16 Amps complete all as specified and directed. |
| 95 | M&L in repair ceiling rose 3 phase PVC polycorbonate,insulated body complete all as specified and directed. |
| 96 | S&F in repair switch type normal electronic fan regulator 5 step complete all as specified and directed. |
| 97 | M&L in repair bell push,flush type,5 amp complete all as specified and directed. |
| 98 | M&L in repair bell ding dong AC,230 volts,single pole complete all as specified and directed. |
| 99 | M&L in repair insulated body pvc, angle holder (metal ring) B22 type ISI marked complete all as directed. |
| 100 | M&L in repair Modular switch 1 way 6A,1 module, 230V, 50 Hz complete all as specified and directed. |
| 101 | M&L in repair Modular switch 1 way 16A,1 module, 230V, 50 Hz complete all as specified and directed. |
| 102 | S&F in repair Modular socket 6A- 5 pin combined 2 module,230V, 50 Hz complete all as specified and directed. |
| 103 | S&F in repair Modular socket 6A/16A - 2/3 pin combined 2 module, 230V, 50 Hz complete all as specified and directed. |
| 104 | M&L in repair switch modular type single pole Bell push 6 Amp 1 module complete all as specified and directed. (As per sample) |
| 105 | S&F in repair Modular ceiling fan regulator, step type for BLDC ceiling fan 1 or 2 module. (As per sample) |
| 106 | S&F in repair metal plug top 20 Amps 3 pin 230 volts complete all as specified and directed. |
| 107 | S&F in repair PVC plug socket 20 Amps 3 pin 230 volts complete all as specified and directed. |
| 108 | S&F in repair 15A plug top 240 Volt AC and connection complete all as specified and as directed |
| 109 | S&F in repair of SS combined 15 amp without Box complete all as specified and directed.(As per sample) |
| 110 | S&F in repair of SS combined 15 amp with Box complete all as specified and directed. |
| 111 | S&F in repair of SS combined 5 amp without Box complete all as specified and directed.(As per sample) |
| 112 | S&F in repair of SS combined 5 amp with Box complete all as specified and directed. |
| 113 | S&F in repair ceiling fan capacitor for 1200/1400 mm sweep 2.5 mfd all specfied and directed Please Enable Macros to View BoQ information |
| 114 | S&F in repair ceiling fan capacitor for 1200/1400 mm sweep 2.5 mfd all specfied and directed Please Enable Macros to View BoQ information |