| 1 | Taking down cement plaster of any description on bricks walls etc, including racking out joints, hacking for keys, scrubbing down with water etc, complete all as specified and as directed. |
| 2 | Demolition of brick work or stone/boulder masonry, built in cement or lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 3 | Material and labour for Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 4 | M&L for rendering 15mm thick in (CM 1:4) with WPC on fair faces of brick work or concrete surfaces and to be finished fair and even complete all as specified and as directed. Note: WPC shall be measured paid separately. |
| 5 | Supply only integral water proofing compound complete all as specified and as directed. |
| 6 | M&L for preparation of new plastered wall surface and applying two coat of cement base paint in camouflage pattern over a coat of primer complete all as specified and as directed. |
| 7 | M&L for preparation of old plastered wall surface and applying one coat of cement base paint in camouflage pattern complete all as specified and as directed. |
| 8 | M&L for preparation of old steel surfaces over 10 cm in width of girth and applying one coat of synthetic enamel paint over the high security boundary wall complete all as specified and as directed. |
| 9 | Demolition of Cement concrete (unreinforced) of any description and in any position, surface channels not otherwise specifically provided for complete all as specified and as directed. |
| 10 | M&L for 100mm thick cement concrete type B-1, ( 1:2:4) (20 mm graded aggregate) finished even and smooth without using extra cement etc complete all as specified and as directed. |
| 11 | Dismantling of stone slabs & tiles of any description or thickness (except ceramic tiles) in floors, aprons etc laid bedded & pointed in any mortar complete all as specified and directed. |
| 12 | Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in soft soil complete all as specified and as directed. |
| 13 | M&L for Hardcore using broken stone or boulders nexc 63 mm deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 14 | M&L for 75mm thk Cement concrete Type D2 1:4:8 (40 mm graded aggregate) in footpath/Hard standing and finished the surface fair and even complete all as specified and directed. |
| 15 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 16 | Removing of excavated material n exc 50 m and depositing where directed at a level n exc 1.50m above the starting points in soil complete all as specified and as directed. |
| 17 | M&L Continuous brick edging; with width equal to the width of the brick; laid dry on end vertically with old size bricks complete all as specified and as directed. |
| 18 | Dismantling wrought iron, or mild steel or cast iron work of any description not otherwise provided for complete all as specified and as directed. |
| 19 | S & F mild steel angle iron fencing posts, struts and flat iron for fixing fencing and similar work conforming to Fe-290 Gde E- 165 including cutting tops to shape as directed, bent to shape, drilling holes, notching, hooking for wire etc.complete all as specified and as directed. |
| 20 | M & L for preparation new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint of 1st grade quality over and including one coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 21 | S&F in repairs Concertina coil 600mm Dia/56 Loops/2.5 mm core wire. Coil Diameter:600 mm. Type of Strip: Heavy Galvanized (IS 1730) Type of Core Wire: Heavy Galvanized (IS 280-2006) Core wire Diameter:2.50mm Dia Zinc coating to Strip: Minimum 200 GSM/Sq mm, Zine Coating on wire: Minimum 275 GSM/Sq mm (IS 6745-1972 reaffirmed 2006). Tensile Strength of wire 1400-1500 N/Sq mm Weight: 14.63 Kg (+5%) Number of Loops: 56 Blade Length: 22mm Barb Profile Medium Blade (MBBT) Distance Between Barb 35mm. Strechable length 12 mtrs. Type of clip Hardened Steelin Galvanized steel complete all as specified and as directed. |
| 22 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and as directed.(each line wire to be measured) |
| 23 | Dismantling of fencing wire mesh of any type n exe 4kg/sqm complete all as specified and as directed. |
| 24 | Supply only coated chain link MS galvanised fencing aprature size 50 mm and wire of 8 swg (4 mm), with line wire any size or type complete all as specified and directed. |
| 25 | Fixing only coated chain link fencing, including line wires any mesh, size and type to any type of standards, rails, straining bolts, etc incl provision of binding wire complete all as specified and directed. |
| 26 | S&F Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde -E-165) complete all as specified and as directed. |
| 27 | S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 28 | Supply of Mild steel screw bolts (machine made) with hexagonal or square heads at one end andscrewed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm long but n exc 10cm long and 16 to 20mm Diameter of neck complete all as specified and directed. |
| 29 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed. |
| 30 | Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in hard/dense soil complete all as specified and as directed. |
| 31 | M&L for plain cement concrete Type D-2 1:4:8 (using 40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and as directed. |
| 32 | M&L for Cement concrete in foundations, filling and mass concrete, type B2 1:2:4 (40mm graded aggregate) complete all as specified and as directed. |
| 33 | Supply and fix mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 34 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 35 | Dismantling Asbestos cement (corrugated and semi-corrugated etc sheet) in roof coverings complete all as specified and directed. |
| 36 | Supply and fixing Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed. |
| 37 | S&F for prepainted galvalume aluminium zinc coating GI based plain sheet 0.5mm thk of any colour having tensile strength of 550MPa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. Please Enable Macros to View BoQ information |