Tender For special Repair Of Security Lights And Alled Works At Stn Hq Area, Provn Of Veh Parking Shed Near Bldg No P-386 And Other Sanctioned Work In Army Area Under Ge (A) No 1 Jodhpur Job Nos (I) 10/Sr (M&O)/ Jodh/ 2025-26 (Ii) 36/Rw/Jodh/2025-26
Tender Value
43.15 Lakhs
Estimated cost
Bid Submission
10 Jul 2026
9 days left
EMD
86300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair Of Security Lights And Alled Works At Stn Hq Area, Provn Of Veh Parking Shed Near Bldg No P-386 And Other Sanctioned Work In Army Area Under Ge (A) No 1 Jodhpur Job Nos (I) 10/Sr (M&O)/ Jodh/ 2025-26 (Ii) 36/Rw/Jodh/2025-26 (Iii) 33/Rw/ Jodh/2025-26 (Iv) Jodh/Mw/18/2025-26
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, erection of poles, struts/stays, leveling of yard etc not exceeding 10 M² on plan and not exceeding 1.5 m in depth and getting out in any type soil, complete all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in depth but not exceeding 3.0 m in depth for laying of cables, erection of poles, struts/stays, leveling of yard etc not exceeding 10 M² on plan and not exceeding 1.5 m in depth and getting out in hard rock, complete all as specified and directed. |
| 3 | Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description complete all as specified and as directed |
| 4 | M &L for plain cement concrete 1:4:8 ,type D-2 (using 40 mm graded crushed stone aggregate) as in foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and direc |
| 5 | M&L for squared rubble walling, Jodhpur type, regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6, complete all as specified and directed. |
| 6 | Extra over stone walling for hammer dressing to face stone & dressing of face beds & joints as specified of squared rubble walling Jodhpur type brought upto courses with maximum depression of face from straight edge held against the dressed surface n exc 20mm and dressing face beds and joints, complete all as specified and directed. |
| 7 | M&L for framed work as in banks,straps, supports or stays for rainwater, ventilating pipes, including bolts, if required ; hooks ( stay), heavy, for large gates ; hook and pintle hinges; large hasps and staples; chain; hand made sliding bolts; clamps; hold fasts ; will ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters ; knee piece inserts ; two way and three way straps, plate washers and similar small articles conforming to Fe 290.Gde E165,complete all as specified and directed. |
| 8 | M&L for 20 mm thick Granite (of any type) work ( table rubbed and polished ) in steps, jambs, pillars, window cills cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite ,over & including 15 mm thick screed bed in cement mortor 1:4, rubbing,moulding and polishing complete all as specified and directed. |
| 9 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft /loose soil complete all as specified and directed. |
| 10 | M&L for hard core broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, water and rammed to a true surface, complete all as specified and as directed. |
| 11 | M&L for 75 mm thick plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring, etc complete all as specified and directed. |
| 12 | M & L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand etc., complete all as specified and as directed. |
| 13 | Supply and laying factory made kerb stone of M-25 grade, at or near ground level, cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 ( 1 part cement : 3 part coarse sand), including making joints with or without grooves ( thickness of joints except at sharp curve shall not more than 5 mm), including making drainage opening wherever required , complete all as specified and directed, |
| 14 | Removal of surplus excavated soil not exceeding 50 mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 15 | Returning, filling in including spreading, levelling, watering and well ramming in layers of not exceeding 25 cm thick in each layer complete all as specified and directed by Engineer-in-Charge. |
| 16 | Excavating in post holes (of similar holes) each not exceeding 0.50 cum getting out in hard/dense soil and making good surface complete all as specified and directed. |
| 17 | M &L for plain cement concrete 1:3:6 ,type C-2 (using 40 mm graded crushed stone aggregate) as in foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed. |
| 18 | S&F for rolled mild steel roof trusses( framed),trussed, vetrical post, purlins, crane gantries, rails and fastenings and heavy bracket framing including distance pieces,cleats tee angle etc.conforming to grade Fe 410-W Grade E-250 quality etc complete all as specified and directed |
| 19 | M&L for plates (plain or chequered) channels, square cut ot notched (ordinary and counter sunk) forming holes, without any attachment conforming to grade Fe 410-W, Grade E-250 quality etc complete all as specified and directed |
| 20 | M&L for prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed. |
| 21 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa & minimum AZ @150 gm/Sqm( be coated with hot dip alloy of 55 % aluminium, 43.5% Zinc, 1.5% Silicon and finished with resin coat on both surface @ 150 gm/Sqm of coating both surfaces) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed. |
| 22 | M&L for precast cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in louvres and jallies, cement grill any type model of Zafri , 40 mm thick (measured solid), set in cement mortar 1:4 fixed with PCC post, including all mouldings & mild wire as reinforced wire etc, complete all as specified and directed. |
| 23 | M & L providing precast concrete posts 1:2:4 type B-0( using 12.50 mm graded crushed stone aggregate) as in RCC jali post (size 150x150mm size & 750 mm height), setting in cement mortar 1:6 with & including requird reinforced complete all as specified and directed. |
| 24 | M&L keyed pointing in cement mortar (1:3) to squared rubble masonry regular coursed or uncoursed complete all as specified & directed. |
| 25 | M&L for preparation of newly plaster surface of walls/chajjas/lintel and applying two coats of cement base paint white or tinted over a coat cement base primer including necessary scaffolding complete all as specified & as directed. |
| 26 | Supply and fix water heater, stroage type steel body with copper inner tank and heating element 2 KW capacity 25 ltr, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV , including inlet and outlet ( hot & cold) connection piece, brass nut etc. complete ass as specified and directed.Note :Five year warranty of geyser body & two year warranty of element and thermostate. |
| 27 | M & L Sub main wiring with two runs of single core 2.50 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 2.50 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia/appropriate dia with accessories & fittings complete and making good disturbed surface wall complete all as specified and as directed. Note : - Two runs of 2.50 Sqmm cable and one run of earth wire 2.50 Sqmm & conduit shall be measured as one unit length and extra length of cable required for connection to MCBs shall be deemed to be include in unit rate quoted by bidder. |
| 28 | M&L for metal clad enclosure three pin plug and scoket complete with MCB SPN 20 Amps Ç\\"series ,breaking capacity 10 KA complete all as specified and directed by Engr-in-Charge. |
| 29 | S&F miniature circuit breaker (MCB) of single pole (SP) and current carrying capacity 20 Amp , 240V ,breaking capacity 10 KA, 'C' curve in the MCB DB complete with connection testing and commissioning including suitable size copper lugs complete all as specified and as directed. |
| 30 | M&L for writing letters in black colour synthetic enamel paint 40mm width and height of letter as directed by engineer -in -charge :- (a) Manufacturer srl No. (b) Date set to work. (c) Initial cost. (d) PRB page No. (e) Location etc, complete. |
| 31 | S & F for 15mm bore stop valve , chromium plated cast copper alloy, screwed down, high pressure, with crutch handle, screwed both ends for brass ferrule,complete all as specified and directed. |
| 32 | S&F PVC connection (ISI Marked) 15mm dia, 450 mm long with brass alloy crome plated nuts , suitable for hot and cold water application complete all as specified and directed. |
| 33 | Supply ,fixing & laying for GI water tubing medium grade, ISI marked, galvanised, 15 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors/laid in trenches including cutting chases for brick walls and making good the surface in cement mortar 1:3 complete all as specified & directed. |
| 34 | M & L for cutting existing location and position galvanised pipe upto 50mm dia inserting tee of required size and connecting 15 mm dia pipe complete all as specified & directed. |
| 35 | S&F for 15mm bore long body (weight not less than 400 gm) bib tap, cast copper alloy, CP fancy type with crutch or butterfly handle, screw down, screwed for iron pipe or for brass ferrule including flange complete all as specified and directed |
| 36 | Supply, laying , jointing & testing LT cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor,1100 Volts grade of cross sectional area 185 Sqmm 3.50 core.laid in trenches/ducts /encased in GI pipe /fixed to pole including taking down existing cable complete all as specified and directed. Note: Earthwork, RFR, removing of excavated soil, precast concrete cable cover, sand for cusioning of cable & GI protection pipe shall be measured and paid seperately under respective of BOQ. |
| 37 | Supply, laying , jointing & testing LT cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor,1100 Volts grade of cross sectional area 120 Sqmm 3.5 core.laid in trenches/ducts /encased in GI pipe /fixed to pole including taking down existing cable complete all as specified and directed. Note: Earthwork, RFR, removing of excavated soil, precast concrete cable cover, sand for cusioning of cable & GI protection pipe shall be measured and paid seperately under respective of BOQ. |
| 38 | Supply, laying , jointing & testing LT cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor,1100 Volts grade of cross sectional area 50 Sqmm 3.50 core.laid in trenches/ducts /encased in GI pipe /fixed to pole including taking down existing cable complete all as specified and directed. Note: Earthwork, RFR, removing of excavated soil, precast concrete cable cover, sand for cusioning of cable & GI protection pipe shall be measured and paid seperately under respective of BOQ |
| 39 | Supply, laying , jointing & testing LT cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor,1100 Volts grade of cross sectional area 35 Sqmm 3.5 core.laid in trenches/ducts /encased in GI pipe /fixed to pole including taking down existing cable complete all as specified and directed. Note: Earthwork, RFR, removing of excavated soil, precast concrete cable cover, sand for cusioning of cable & GI protection pipe shall be measured and paid seperately under respective of BOQ. |
| 40 | Supply, laying , jointing & testing LT cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor,1100 Volts grade of cross sectional area 16 Sqmm 4 core.laid in trenches/ducts /encased in GI pipe /fixed to pole including taking down existing cable complete all as specified and directed. Note: Earthwork, RFR, removing of excavated soil, precast concrete cable cover, sand for cusioning of cable & GI protection pipe shall be measured and paid seperately under respective of BOQ.. |
| 41 | Supply, laying , jointing & testing LT cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor,1100 Volts grade of cross sectional area 10 Sqmm 2core.laid in trenches/ducts /encased in GI pipe /fixed to pole including taking down existing cable complete all as specified and directed. Note: Earthwork, RFR, removing of excavated soil, precast concrete cable cover, sand for cusioning of cable & GI protection pipe shall be measured and paid seperately under respective of BOQ. |
| 42 | Supply and spreading clean, dry, fine river sand for under ground electric cable in two layers (8cm thick before laying of cable & 15cm thick after laying cable to a total of 23cm) including gentle punning the sand upto 18cm (total thickness) and consolidated around cable for protection of UG cable complete all as specified and directed. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I. |
| 43 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250 mm x 150 mm x 40 mm and abutting each other with gap between adjacent precast concrete cable cover not exceeding 10 mm over underground cables for protection, complete all as specified and as directed. |
| 44 | M& Lfor Earthing complete with GI earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth strip of size 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I (2009) connected to LT panel boards all as specified and directed including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1(using 20 mm graded crushed stone aggregate ) as in pit, 20mm dia GI pipe medium grade for watering pipe, 40 mm dia bore GI light grade as earth strip protection pipe, 50 mm thick pre-cast RCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate ) as in cover slab of size 300 mm x300 mm x 50mm as earth pit cover slab with & including 8 mm dia TMT bars @ 100 mm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer, charcoal and testing on completion including dismantling / taking down of old unserveciable earthing complete all as specified and directed. Note-(i) Unit rate quoted by bidder deemed to be included excavation a(ii) Rate included for excavation & earth work in any type of strata as shown in electric plate no-3 in SSR Part-I. |
| 45 | Dismantling and removal of Aluminium conductor, steel reinforced (ACSR) conductor any size from the pole at various location complete all as directed by Engr-in-Charge. |
| 46 | Dismantling of cross arms including clamp,nut,bolt & washers etc from site complete all as directed. |
| 47 | Dismantling of insulators any type or any size from existing poles complete all as directed. |
| 48 | Taking down serviceable LT cable of any type and size from existing poles at various location and re used /re laying in ground /along wall at site as directed by Engr-In-Charge,including necessary earth work , sand & PCC covers/stone slab, if required complete all as specified and directed. |
| 49 | Supply and fix security light junction boxes of dimension 240×130×110, with shock proof, rust proof, termite resistant, weather proof, cable entry from bottom , pole mounting arrangement along with 3 phase 4 wire almunium busbar with insulators and MCB SP-0.5 amps rating with provision of MCB, Cable Glands, lugs including three core copper cable with suitable size PVC conduit from junction box to existing LED fitting complete all as specified and directed. |
| 50 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 /4 core XLPE, armoured, aluminium conductor cable of size 120 to 150 Sqmm complete all as specified and directed. |
| 51 | Supply and fix cable path indicators made out of thick roughly hamer dressed stone slab size (30cmX75cmX7.5cm) with applying two coats of paint , marking of voltage and size of cable, route including necessary earth work required complete as specified and directed by Engr-in-charg. |
| 52 | Supply and erection of steel tubular pole swaged type 410-SP -22 (08.50 mtr long pole) complete conforming to IS: 2713 complete with mild steel base plate, finial taper plug pole cap, mild steel bolt, nuts and screws,painting of pole externally with one coat of black bituminous paint (upto planting depth) and remain exterior portion of the pole shall be painted with two coats of aluminium paint over a coat of primer with blue & white strip upto 1.20 m height above GL and all as specified and directed with two coat of aluminum paint over a coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 5 Nos with yellow and black paint of radium/photosinthetic paint alternately on external surface above base / coping upto the height of 1.5mtr above plinth block,writing letter or figures (Block Roman) with thick synthetic enamel paint of approved shade not exceeding 5 cm height including numbering of pole, Painting coping with two coats of cement based paint etc complete all as specified and directed.NOTE : (i) All excavation and earthwork ,PCC shall be measured and paid separately under respective items of BOQ. (ii) Manufacture's test certificate for pole shall be produced before execution work. |
| 53 | M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in kerb/benching/copings including weathering, slightly rounded or chamfered angle and throating including use & waste of necessary form work etc complete all as specified and directed |
| 54 | Supply and fix of smart LED Street with PDC housing, IP 66 and IR sense based auto ON/OFF capacity 60 Watts including providing GI pipe bracket made out of 32 mm dia light grade GI pipe bend to shape as per site requirement not less than 1.50 m long to be fitted / fixed to on PCC/Steel tubular pole/ wall with & including nuts, bolts of 12 mm dia 100 mm long including washer, 40 x 6 mm size clamps-03 Nos etc and applying two coat of aluminium paint over a coat of primer on steel surface complete all as specified and directed. |
| 55 | Auguring/driling in road/Boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including sutable for laying of 50 mm /40 mm dia GI tubing pipe complete all as specified and directed by the Engineer-in-Charge. |
| 56 | Supply and laying GI pipe 40 mm bore light grade with fitting for cable protection at under road crossing/ for protection of cables on poles / wall including taking down of old one,& clamp.nuts & bolt etc.,complete all as specified and directed by the Engineer-in-Charge. |
| 57 | Supply and laying GI pipe 50 mm bore light grade with fitting for cable protection at under road crossing/ for protection of cables on poles / wall including taking down of old one,& clamp.nuts & bolt etc.,complete all as specified and directed by the Engineer-in-Charge. |
| 58 | S&F of LED based bollard with aluminium pipe housing, PDC base and top cover with glare free PC diffuser and High Lumen with IP 66 protection suitable for LED 1X15 Watt , with 4 way connector from electric connection , 1.0 meter height and including foundation complete all as specified and directed by Engr-in-Charge. |
| 59 | S & F in replacement of PVC insulated, sheathed weather proof, flate cable copper stranded conductor of size 2.5 sqmm, twin core complete all as specified and directed by EIC. |
| 60 | Supply and laying in trenches of HDPE double wall corrugated ( DWC) pipe conforming to IS-16205:2018 having 25mm dia including necessary earth work (depth not less than 350mm) complete all as directed by Engr-in-charge. |
| 61 | Supply and fix street light timer switch using digital timer switch for switching of street lights based on timing set manually on digital timer. The digital timer switch along with suitable power contactors, MCBs in incoming and outgoing side, copper short links in contactors, PVC insulators for incoming and outgoing 40 amps MCBs and 02 Nos support terminals to support the timer box on pole and wall, including suitable lugs and cable glands, enclosure made of rust proof, electric shock proof, termite proof and junction box conforming to IP 65 suitable for three phase complete all as specified and directed, |
| 62 | Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, factory made (CPRI approved) suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 200 amps duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA.The panels shall be factory made, double door, made out of 3.15 mm thick and inner shall be of 2.00 mm thick mild steel sheet totally enclosed dust, vermin and 33 Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable Each roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 200 amps duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1200 mm x 900 mm x 450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of mild steel angle section not less than 50 mm x 50 mm x 5mm. Entire panal shall have common aluminimum earth bar of size 25 mm x 5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of copper bas bar and controlling wiring with minimum 1.5 sqmm PVC insulated copper conductor cable. The ground clearance should be minimum 600 mm. mild steel angle section 30 mm x 30 mm x 5 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size including lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- |
| 63 | (A) IN COMING |
| 64 | (a) MCCB 4 Pole 415 Volts,breaking capacity 36 KA, 250 Amp rating thermal magnetic adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No. |
| 65 | (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. |
| 66 | (c) Panel mounted multi function energy (voltmeter & ammeter) meter of accuracy CL-1.0 rating including CT of ratio 200/5 - 01 No |
| 67 | (B) OUT GOING |
| 68 | (a) MCCB 4 Pole, 415 Volts,breaking capacity 36 KA, 160 Amp rating thermal adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No. |
| 69 | (b) MCCB 4 Pole ,415 Volts,breaking capacity 35 KA, 100 Amp rating thermal adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -02 No. |
| 70 | (c) MCCB 4 pole, 415 volt , breaking capacity 16 KA, 63 Amp rating thermal magnetic release type ( icu= ics= 100%) |
| 71 | Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable Each roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 200 amps duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick mild steel Sheet totally enclosed of size not less than 1200 mm x 900 mm x 450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of mild steel angle section not less than 50 mm x 50 mm x 5mm. Entire panal shall have common aluminimum earth bar of size 25 mm x 5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of copper bus bar and controlling wiring with minimum 1.5 Sqmm PVC insulated copper conductor cable. The ground clearance should be minimum 600 mm. mild steel angle section 30 mm x 30 mm x 5 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size including lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge |
| 72 | (A) IN COMING |
| 73 | (a) MCCB 4 Pole, 415 Volts, breaking capacity 36 KA, 160 Amp rating thermal magnetic release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No. |
| 74 | (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. |
| 75 | (c) Panel mounted multi function energy (voltmeter & ammeter) meter of accuracy CL-1.0 rating including CT of ratio 200/5 - 01 No |
| 76 | (B) OUT GOING |
| 77 | (a) MCCB TPN, 415 Volts,breaking capacity 35 KA ,63 Amp rating - 03 Nos |
| 78 | (b) MCCB 4 Pole, 415 Volts,,breaking capacity 35 KA, 100 Amp rating thermal magnetic adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No. |
| 79 | (c) Changeover switch 4 pole, 415 Volts ON load 100 Amp rating.panel mounting type 415 volt in sheet metal enclosure - 01 No. Note- Phase barriers & handle with door integral part of the chandeover switch . |
| 80 | Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, factory made (CPRI approved) suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 400 amps duly insulated by insulation of RYB colour 100 Amps rating mounted on porcelain insulators. The panels shall be factory made and minimum size of panel 1.5mtrs X 1.2mtrs X 0.5mtrs double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40X40X5 mm and including of lowers on both sides including embedding the panel in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed and including danger board and including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge and including taking down existing panel & comprising of the following:- |
| 81 | (A) IN COMING |
| 82 | (a) MCCB 4 Pole, 415 Volts ,breaking capavity 36 KA ,250 Amp rating microprocessor release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No |
| 83 | (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. |
| 84 | (c) Panel mounted multi function energy (voltmeter & ammeter) meter of accuracy CL-1.0 rating including CT of ratio 200/5 - 01 No |
| 85 | (B) OUT GOING |
| 86 | (a) MCCB 4 Pole, 415 Volts, breaking capacity 36 KA, 100 Amp rating microprocessor release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 Nos |
| 87 | Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable Each roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 200 amps duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1200 mm x 900 mm x 450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of mild steel angle section not less than 50 mm x 50 mm x 5mm. Entire panal shall have common aluminimum earth bar of size 25 mm x 5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of copper bas bar and controlling wiring with minimum 1.5 Sqmm PVC insulated copper conductor cable. The ground clearanc should be minimum 600 mm. mild steel angle section 30 mm x 30 mm x 5 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size including lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge & comprising of the following:- |
| 88 | (A) IN COMING |
| 89 | (a) MCCB 4 Pole 415 Volts,,breaking capacity 35/36 KA ,100 Amp rating thermal magnetic adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No. |
| 90 | (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. |
| 91 | (c) Panel mounted multi function energy (voltmeter & ammeter) meter of accuracy CL-1.0 rating including CT of ratio 200/5 - 01 No. |
| 92 | (B) OUT GOING |
| 93 | (a) MCB TPN, 415 Volts,breaking capacity 25 KA ,63 Amp rating,, \\"C\\" series - 02 Nos |
| 94 | (b) MCCB 4 Pole 415 Volts ,breaking capacity 25 KA, 200 Amp rating thermal adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No. |
| 95 | Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable Each roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus Job bars chamber with copper bus bars of rating 200 amps duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick mild steel Sheet totally enclosed of size not less than 800mm x 600 mm x 450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bottom base channel of mild steel angle section not less than 50 mm x 50 mm x 5mm. Entire panal shall have common aluminium earth bar of size 25 mm x 5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of copper bus bar and controlling wiring with minimum 1.5 Sqmm PVC insulated copper conductor cable. The ground clearance should be minimum 600 mm. mild steel angle section 30 mm x 30 mm x 5 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size including lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge complete all as directed by Engr-in-charge & comprising of the following:- |
| 96 | Incoming :- |
| 97 | (a) MCCB TPN, 415 Volts, breaking capacity 35 KA, 100 Amp rating thermal magnetic adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No. |
| 98 | (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. Please Enable Macros to View BoQ information |
| 99 | (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysJul 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 days