| 1 | M&L inspection, cheking and repair of APFC panel by cleaning of dust inside with blower, cleaning of moving part/contract from CT cleaner, tightening of loose parts/electrical wiring , cleaning of contractors, relays and capacitor juction points, oiling of cooling fan , complete testing of APFC relay with necessary settings with CTs /load adjustments to match with the APFC load management system complete with replacement of burnt/worn out unserviceable components /burnt wires thimbles /lugs etc for APFC panel capcity 50 KVAR to 150 KVAR complete all as specified and directed. Note : All unserviceable parts shall be measured and paid seprately as supply only. Replacment of small nuts/screws, wires lugs or thimbles and cleaning material cost included in this item. complete all as specified and directed. |
| 2 | Supply only MCB, TP 6 to 32 Amp 10 KA C curve for existing APFC panel complete all as specified and directed. |
| 3 | Supply only MCB, TP 40 to 63 Amp 10 KA C curve for existing APFC panel complete all as specified and directed. |
| 4 | Supply only Auxillary contractor 1 NO+1NC TP 415 volts suitable for 25 KVAR rating for existing APFC panel complete all as specified and directed. |
| 5 | Supply only Auxillary contractor 1 NO+1NC TP 415 volts suitable for 50 KVAR rating for existing APFC panel complete all as specified and directed. |
| 6 | Supply only capacitor 440 volts 50 Hz 15 KVAR for existing APFC panel complete all as specified and directed. |
| 7 | Supply only capacitor 440 volts 50 Hz 25 KVAR for existing APFC panel complete all as specified and directed. |
| 8 | Supply only capacitor 440 volts 50 Hz 50 KVAR for existing APFC panel complete all as specified and directed. |
| 9 | Supply only APFC relay square flush type with protection devices intelligent auto processor based on electronic controller unit 6 stages for existing APFC panel complete all as specified and directed. |
| 10 | Supply only APFC relay square flush type with protection devices intelligent auto processor based on electronic controller unit 8 stages for existing APFC panel complete all as specified and directed. |
| 11 | Supply and fix and draw ACSR Weasel conductor of size 06 strands of aluminium of 2.59 mm dia and 1 strand of steel of 2.59 mm dia on HT/LT poles, bringing the sag within limit fixing on Insulator/Cross arms by means of necessary binding with 16 SWG aluminium binding wire and providing alkathin pipe of approved quality for jumpers, reconnecting the service connections after removing the carbon material including taking down old UNSV, ACSR conductor of any size & type from LT poles at any height position and place complete all as specified and directed. |
| 12 | M&L for work confirming to Fe-410-O or Fe-310-O as in cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of aluminium paint over a coating of red oxide primer including taking out old UNSV cross arms complete all as specified and directed. |
| 13 | Supply and fix in replacement of steel tubular swaged poles type 410 SP-31 (9 meter long), Including taking out old UNSV, RCC/Steel Pole/WOODEN POLE complete all as specified and directed. |
| 14 | Supply & fixing pin type porcelain vitreous insulator 100 mm height and 65 mm dia for 1100 Volts grade including galvanised mild steel spindle, one nut and two washers & Including taking out old UNSV insulators complete all as specified and directed. |
| 15 | Supply and fixing shackle type insulator porcelain vitreous white,brown and green of size 75 mm heaight and 90 mm dia incl galvanised MS straps 31x3 mm size ,washers,insulator bolt 12 mm dia and nut for working pressure 1100 Volts grade & Including taking out old UNSV insulators complete all as specified and directed. |
| 16 | Material & Labour for stay asembly comprising of stay bow (4000 x 14mm), stay rod 215 cm long and 16 mm dia with nuts, stay plate 300 x 300 x 6 mm thick and 2 nos of thimble complete as shown in electric plate no 1 of SSR part-1 connected to loop type insulator, including dismantling old UNSV stay assembly complete all as specified and directed.NOTE :- Earth work excavation, concrete and loop type insulator & Stay wire shall be measured and paid separetely under relevent items of Sch 'A'. |
| 17 | Supply and fix LT loop type insulators, vitreous, porcelain brown, white or green insulators for working pressure of 1100 volts grade of Small size with over all dimensions 65 x 90 mm including dismantling of existing LT loop type insulator from LT poles of any height place and position complete all as specified and directed. |
| 18 | S&F Galvanised stay wire stranded of size 7/4 mm including necessary binding, strengthening complete all as specified and directed. |
| 19 | Material and labour for cement concrete 1:4:8 type D2 using 40mm graded crushed trap stone aggregate for foundation of poles/stays, complete all as specified and directed. |
| 20 | Material and labour for cement concrete 1:3:6 type C1 using 20mm graded crushed trap stone aggregate for coping of HT/LT poles, including necessary form work and finishing exposed surface of concrete even and smooth without using extra cement complete all as specified and directed. |
| 21 | Material and labour for PCC (1:2:4) type B-2, using 40 mm graded crushed stone aggregate for making good the road cutting all as directed by Engr in Charge. |
| 22 | Material and labour for danger notice plate of 1.6 mm thick Mild Steel sheet vitreous enamelled white with letters figure and conventional skull & bones in signal red colour & fixed with MS clamps, bolt,nuts of approved size for LT 20 x 15 cm size including dismantling the old unserviceable one, complete all as specified and directed. |
| 23 | M&L for Preparing old pained surfaces of steel tubular poles sewaged pole of any description and length not exc 7.5 above ground level erected in vertical position in LT OH line including cross arms of angle iron/ channel section clamps brackets etc with one coat of aluminium paint 6.0 mtr from top of the pole onward & remaining with black & Yellow paint strip in 30 cm width alternatively upto ground level & numbering the pole with white paint on black paint base 20 cm dia circular/square shape complete all as specified and directed. |
| 24 | Supplying, laying, testing or passing through pipe and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, including taking out old UNSV, UG cable of cross sectional area 120 Sqmm 3.5 Core complete all as specified and directed. |
| 25 | All as per item No. 24 above but of size 95 Sqmm 3.5 core complete all as specified and directed. |
| 26 | All as per item No. 24 above but of size 70 Sqmm 3.5 core complete all as specified and directed. |
| 27 | All as per item No. 24 above but of size 50 Sqmm 3.5 core complete all as specified and directed. |
| 28 | All as per item No. 24 above but of size 35 Sqmm 3.5 core complete all as specified and directed. |
| 29 | All as per item No. 24 above but of size 25 Sqmm 4 core complete all as specified and directed. |
| 30 | All as per item No. 24 above but of size 16 Sqmm 4 core complete all as specified and directed. |
| 31 | All as per item No.24 above but of size 10 Sqmm 4 core complete all as specified and directed. |
| 32 | Excavation in trenches not exceeding 1.5M width and not exceeding 1.5M depth and getting out for laying of pipe etc in any type of soil complete all as specified and directed. |
| 33 | All as per item No. 32 above but exceeding 1.5 mtr but not exceeding 3 mtrs in depth complete all as specified and directed. |
| 34 | Returning, filling of excavated soil, including spreading leveling, watering and well ramming in layers, not exceeding 25cm complete all as specified and directed. |
| 35 | Removing of surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 36 | Sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete all as specified and directed. |
| 37 | Bricks, old size sub class `B (230 mm x 110mm x 70mm) ' laid in trenches with width wise along the alignment of the cable as protection complete all as specified and directed. |
| 38 | S&F tube 'medium' grade galvanised Pipe of 40 mm dia with all fitting for cable protection, laid in trenches, fixed to wall and floor by MS shaddle & fixed with pole, 02 position by MS clamp made of 40x5 mm MS flat, complete all as specified and directed. |
| 39 | All as per item No. 38 above but of size 50 mm dia. complete all as specified and directed. |
| 40 | Supply & Fixing in replacement MCCB 4 pole 63 amps 50Hz 415 volts with reputing cap 16 KA , complete all as specified and directed. |
| 41 | Supply & Fixing in replacement MCCB 4 pole 100 amps 50Hz 415 volts with reputing cap 16 KA |
| 42 | Supply & Fixing in replacement MCCB 4 pole 125 amps 50Hz 415 volts adjustable type with reputing cap 16 KA , complete all as specified and directed. |
| 43 | Supply & Fixing in replacement MCCB 4 pole 160 amps 50Hz 415 volts adjustable type with reputing cap 25KA , complete all as specified and directed. |
| 44 | Supply & Fixing in replacement MCCB 4 pole 200 amps 50Hz 415 volts adjustable type with reputing cap 25KA, complete all as specified and directed. |
| 45 | Supply & Fixing in replacement MCCB 4 pole 250 amps 50Hz 415 volts adjustable type with reputing cap 36KA, complete all as specified and directed. |
| 46 | Supply & Fixing in replacement MCCB 4 pole 400 amps 50Hz 415 volts adjustable type with reputing cap 36KA complete all as specified and directed. |
| 47 | Supply & fixing in replacement Aluminium thimbles for LT panels in cable and connecting upto with GI nut bolts and washers suitable for 25 Sqmm to 50 Sqmm cable size, complete all as specified and directed. |
| 48 | Supply & fixing in replacement Aluminium thimbles for LT panels in cable and connecting upto with GI nut bolts and washers suitable for 70 Sqmm to 95 Sqmm cable size, complete all as specified and directed. |
| 49 | Supply & fixing in replacement Aluminium thimbles for LT panels in cable and connecting upto with GI nut bolts and washers suitable for 120 Sqmm to 150 Sqmm cable size, complete all as specified and directed. |
| 50 | M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead Strip 32x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40 mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 40 mm dia GI medium grade earth lead protection pipe upto 7.5 mtr length complete all as specified and directed. Please Enable Macros to View BoQ information |