| Sl. No. | Item Description |
| 1 | SCHEDULE \\"A\\" Part-I (Building/Structures) (To be quoted by the tenderer) |
| 2 | Item No 01 : Design & Construction of single living accn with garage for 24 JCOs with permanent specification, RCC frame construction with RCC M-25 design mix, provision of ATT, provn of mosquito proofing, Provn of roof treatment, exterior emulsion paint on external surface OBD in internal surface, complete all as specified and shown on drawings, Soil bearing capacity report, design basis report and tender documents. |
| 3 | Sch 'A' Part-II (External Water supply) Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES. |
| 4 | Sch 'A' Part-III (Demolition) Lump sum price worked out by the contractor for (Demolition) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES. |
| 5 | Sch 'A' Part-IV (External Electric supply) Lump sum price worked out by the contractor for (External Electric supply) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES. |
| 6 | Sch 'A' Part-V (Road Path Culvert) Lump sum price worked out by the contractor for (Road Path Culvert) as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES. |
| 7 | Sch 'A' Part-VI (Area Drainage) Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES. |
| 8 | Sch 'A' Part-VII (Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES. |
| 9 | Sch 'A' Part-VIII (Security Compound wall and Gate) Lump sum price worked out by the contractor for (Security Compound wall and Gate) as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES. |
| 10 | Sch 'A' Part-IX (Rain Water Harvesting) Lump sum price worked out by the contractor for (Rain Water Harvesting) as listed in Schedule 'A' Part-IX against the lump sum price inserted by the MES. |
| 11 | Sch 'A' Part-X (Refrigeration and Air Conditioning) Lump sum price worked out by the contractor for (Refrigeration and Air Conditioning) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES. |
| 12 | Sch 'A' Part-XI (Hot Water Supply & Solar Hot Water) Lump sum price worked out by the contractor for (Hot Water Supply & Solar Hot Water) as listed in Schedule 'A' Part-XI against the lump sum price inserted by the MES. |
| 13 | Sch 'A' Part-XII (Lift) Lump sum price worked out by the contractor for (Lift) as listed in Schedule 'A' Part-XII against the lump sum price inserted by the MES. |
| 14 | Sch 'A' Part-XIII (Site development) Lump sum price worked out by the contractor for (Site development) as listed in Schedule 'A' Part-XIII against the lump sum price inserted by the MES. |
| 15 | Sch 'A' Part-XIV (Internal Electrification) Lump sum price worked out by the contractor for (Internal Electrification) as listed in Schedule 'A' Part-XIV against the lump sum price inserted by the MES. |
| 16 | Sch 'A' Part-XV (Internal Water Supply) Lump sum price worked out by the contractor for (Internal Water Supply) as listed in Schedule 'A' Part-XV against the lump sum price inserted by the MES. |
| 17 | Note for Srl No 3 to 16The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 3 to 16 by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule |
| 18 | Schedule 'A' Part- XVI (Miscellaneous items of works) |
| 19 | Security Compound wall and Gate |
| 20 | Item No 02 : M& L for Steel gate 5.5 m wide as per TD drg No.CEJZ/TD/13 OF SHEET NO 1/2 AND 2/2 DT 5/5/2000 Complete all as spd and directed. |
| 21 | External Water Supply |
| 22 | Item No 03 : Cutting existing pipe up to dia 80mm / 100mm and fixing/ connected new pipe line with all connected accessories Complete all as spd and directed. |
| 23 | Refrigeration and Air Conditioning |
| 24 | Item No 04 : Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with zcuracy of + 2.5% and of capacity 1.00 KVA complete all as specified and directed. |
| 25 | External Electric supply |
| 26 | Item No 05 : Supply, installation, commissioning and testing outdoor wall mounting LT Panel Board of minimum size 1.00 m (height) x 1.00 m (breath) x 0.30m (depth) factory made CPRI approved panel, weather, dust & vermin proof indoor, double door, front openable, including four comparment for fixing of four nos Three phase meter and MCB TPN and providing glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with PVC tape/ sleeves with maintainedvthe colour code and copper strip/wire busbar of suitable size ot MCCB input and MCCB /MCB output of suitable length for connection of cable from main busbar, |
| 27 | made out of 2.50 mm thick mild steel CRCA sheet with suitable size angle in supporting frame including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external internal surface suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 10 Sqmm copper wire and necesary with all incoming and outgoing cables complete all as directed bt Engineer-in-charge. |
| 28 | INCOMMING :-(a) Copper busbar suitable for 250 Amps wrapped with PVC sleeves with maintained the colour code and provision of making holes with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos.(b) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=36 KA breaking capacity, rating 200 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links-01No. |
| 29 | (c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4\\"x4\\") square dial with selector switch - 01 Nos (Make : Legrand/Schneider/L&T)(d) Digital Ammeter 400 Amps -01 Nos(e) LED Neon indicator lamp (RYB) with holder, 230/250 volts, AC -01 set (set of three) Make:-AE, L&T |
| 30 | OUTGOING(a) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=36 KA breaking capacity, rating 100 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links-02 Nos.(b) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 63 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links-01 Nos.(c) MCB TPN 40 Amps- 01 Nos |
| 31 | Item No 06 : M & L in repair for Earthing to Electric panels with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth GI strip of size 25 x 4 mm by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth wire protected by GI pipe 15mm dia light grade and connected to earth test point including excavation in any type of soil, returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete. (2 Nos for LT Panels) |
| 32 | Item No 07 : S & F Wall mounted MCCB VTPN DB 4 way double door with provision of 3 pole MCCB as incomer and SP/TP MCB's / Isolator as outing with metal door protection with suitable rated bus bar complete all as specified and directed by Engr-in-charge. |
| 33 | Furniture Items |
| 34 | Item No 08 : Almirah Med SteelSheet: MS sheet 1mm for Shutter, shelf, sides ,back and bottom shall be used. Fitting: Chromium plated handle with a three way locking device shall be provided as shown on drawing. Brass lock 6 leaver of Make :Godrej/ Harrison.Painting: POWDER COATING:- All steel components shall be Pre Treated 7 stages Epoxy powder coating shall be done. Rest: All as shown on the drawing & as directed by Engr-in-charge |
| 35 | Item No 09 : Bath Mat (Cello)Bath mat shall be made of superior quality PVC as per drawing and as per specified by Engineer-in Charge. Colour : RED/Green/Blue. |
| 36 | Item No 10 : Chair Easy CushionAll as showen on drawing. All wood shall bwe first class hard wood teak (MP). Front lets shall be 70mmx25mmhigh. Rear legs shall be of 70mmx25mm in section stanting 185mm horizontally I height of 490mm. Front and rear rails shall be provided below the seat joining front legs and rear legs. Front legs shall be 510mm apart and rear legs shall be 480mm apart. The top of front legs shall have wooden arms rest of 65mmx25mm in section and 610mm long made to shape as shown of drawing. The legs shall be joined by side rails of 70mmx25mmin section teak wood. The bottom frame of seat shall be of 55mmx20mm in section over which 3mm thick plywood commercial shall be fixed 75mm thick foam cushion of 32 density with upholster with leatherised Rexene of approved shade and texture as directed by Engineer-in-Charge. |
| 37 | The side frame of back rest shall be of 70mmx25mm in section joined with seat and rear legs as shown on drawing and fixed back support of 55mmx20mm in section fixed horizontally between side frames of back rest. 3mm thick plywood commercial shall be fixed over the wooden frame of back rest over which 50mm thick 32 density foam upholstered with leatherised Rexene shall be provided over the wooden arms as shown of drawing ans as directed by Engineer-in-Charge. All wood surfaces exposed to view when placed in position shall be French polished with lacquer finish. Hard rubber/PVC shoes of 25mm dia and 25mm high shall be provided to the bottom of legs with screws.FD-358 |
| 38 | Item No 11 : Chair WritingTimber : All wood work shall be 1 st class MP Teak wood well seasoned free from all defect and knots .Cane : Caning shall be of with 2.0mm wide and 0.4mm thick plastic cane half round of superior quality white or cream colour woven to the pattern all as shown on the drawing and as approved by the Engineer-in-charge (Godrej Pattern). Strengthening band shall be of 3.5mm wide plastic cane.Make : Premier/Shah/Garware .Ring : Hard PVC ring shall be 20mm dia screwed to bottom of the legs.Polish : All expose wooden surface shall be French polished glossy finish.Rest: All as shown on the drawing & as direc ted by Engr-in-chargeFD-280 |
| 39 | Item No 12 : Bed HardPipe: 38mm sq 1.2mm thick Square pipe for the main frame of head & foot board 19mm sq 1.2mm thick for inner frame for head & foot board 65mm x 25mm 1.2mm thick for long rails, 25m sq 1.2mm thick for stiffener under 12mm plywood shall be used. Prelaminate PARTICLE BOARD: 18mm prelaminted PARTICLE BOARD board exterior grade shall be used in head and foot board with PVC taping 1mm thick all round the board of Make : Kit Ply /Greenply/Century. Plywood: 12mm BWP plywood shall be used for the top Plywood Make: Century/Greenply/Kit Ply Finish: All steel surface shall be black 7 stages pre treated powder coating shall be done.Rest : All as shown on drawing & as directed by Engr-in-ChargeFD-E6/ MAP/08(R) |
| 40 | Item No 13 : Table Dressing Gents with MirrorTimber : All wood work shall be 1 st class MP Teak wood well seasoned free from all defect and knots. Prelaminate PARTICLE BOARD: 18mm prelaminted PARTICLE BOARD board exterior grade IS-12823 of Make : Kit Ply /Greenply/Century shall be used. Back of the shall be of 12 mm commercial plywood and back of the mirror shall be of 6 mm Commercial plywood. Mirror : Mirror Shall be of 5mm sheet glass of Make Saint Gobain/ Modi Guard/ Golden Fish. Mirror Frame shall be fixed with Piano Hinge and one no of Magnetic catcher. Polish : All exposed wooden surface shall be French polish glossy finish.Rest : All as shown on drawing. FD-230 |
| 41 | Item No 14 : Table writingTimber: All wood work shall be 1 st class MP Teak wood well seasoned free from all defect and knots.Board: 18mm pre laminate PARTICLE BOARD Board exterior grade IS-12823 for sides, top, shutter, shelf, and front of drawer beading shall be 4mm teak fixed with head less nail.Plywood: Back of the box and bottom of the drawer shall be of 6mm commercial plywood IS-303. Sides and back of the drawer shall be of 12mm commercial plywood.Lock: Brass lock with four lever shall be provided to shutter (Make: Godrej/ Harrison).Shoes: 25 mm dia high rubber/PVC shoes shall be fixed to botom of legs of table with screws.Polish : All exposed wooden surface shall be French polish glossy finish.Rest : All as shown on drawing. FD-275 |
| 42 | Item No 15 : TeapoyTimber: All wood shall be 1st class MP teak wood well seasoned free from all defect and knots. One extra stifener between short rails of legs to be provided of size 25x25mm thick in middle of teapoy on side short rail stifener both and two end.TOP: 18mm Prelaminted particle board exterior grades ISI marg. Make: Kit Ply/Green Panel. Beading shall be 4mm teak wood fixed with head less nails. Shoes hard rubber/PVC shoes shall be provided at the bottom of the leg. French polish glossy finish. Rest all as shown on drawing and as directed . FD-278 |
| 43 | Sewage Disposal |
| 44 | Item No 16 : Supply laying and testing of 150 mm inner diameter of double well corrigated high density polethelene pipes (HDPE) and Stiffness class-8(SN-8) with ISIS marked with including all fitting & jointing materials for sewage line and laid in trench. complete all as spd and directed. |
| 45 | Item No 17 : S&F factory made SFRC MH cover with frame confirming to IS 12592-2002 HD 20 Grade of Size 750 mm circular or rectangular sorrounded with steel strip 70 x 1.5 mm reinforced shall be as per relevet IS and laid over man hole brick work or concrete in CM 1:4 including Reinforcemnt complete all as spd and directed |
| 46 | Item No 18 : RCC Septic tank designed to carry sewage and sludge water, excavation in hard dense soil, PCC 1:4:8 below the foundation, RCC M-30 design mix in walls, base slabs, baffle walls and roof slab including beams etc ewith Vent shaft, Manhole openings with cover connection etc, complete with Effective depth of 1.5m and over all depth of 3mtr for 50 users septic tank with upflow filters complete all as specified and directed. |
| 47 | Item No 19 : Soakage well excavation in hard dense soil, foundation in PCC 1:3:6, walls of honey combed masonary with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonary in CM 1:4, RCC cover slab in M25 interconnecting pipes of RCC complete filled with brick bats of size 1.8 m Dia x 3.0 m effective depth complete all as sped and directed. |
| 48 | Item No 20 : M & L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanised earth 32 x 6 mm galvanized MS strip by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc complete all as shown in electrical plate No 3, connected to earthing test point including 15mm dia eavy Grade GI pipe for protection of GI wire up to test point and 40mm dia GI Pipe heavy Grade for watering with wire mesh, funnel complete including testing on completion all as specified. |
| 49 | Internal Electrification |
| 50 | Item No. 21 : S & F modular type TV Socket out let complete all as specified and as directed. |
| 51 | Item No. 22 : Supply and fixing wall mounted indoor decorative type fitting of wattage 1x 10 w warm white LED lamp along with material MS type poly carbonate/ glass diffuser comprising base cap B22 suitable for bed room , dining room , living room including led bulb having Luminous Efficacy range lies between ( ≥90 and <105 ) lm/W as per BEE guidelines warranty for 1 year complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor with flexible conduit of suitable size complete all as specified and as directed. |
| 52 | Internal Water Supply |
| 53 | Item No. 23 : S&F for CP Towel rail 600 mm long fixed with an incl chromium plated brass screws and wooden cleat (min wt 190 gms) complete all as specified and directed. |
| 54 | Item No. 24 : S& F for CP Towel ring of dia 250 mm fixed with an incl chromium plated brass screws and wooden cleat (min wt 190 gms) complete all as specified and directed. |
| 55 | Item No. 25 : Supply and fixing of brass extension nipple 15 mm dia and 50-75 mm long alongwith SS cover plate complete all as specified. |
| 56 | Item No. 26 : S & F CP Health faucet mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 57 | Item No. 27 : S& F for CP jet sprey of leangth 1.25 m long fixed in posuition. Complete all as specified and directed. |
| 58 | Item No. 28 : S&F Brass CP WHB mixer central hole15 mm dia for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 59 | Rain Water Harvesting |
| 60 | Item No. 29 : S&F In-line FL-250 suitable for area upto 250 sq mtr self cleaning dual intensity roof top rain water harvesting gravity filter 360 rotatable working on cohesive & centrifugal force of max discharge at 250 ltrs per minute, mesh size-250 micron suitable for intensity of rainfall upto 75mm/hour over ended, non-clog, 100 mm lntel size and clean water outlet size-90 mm with reducer upto 75mm, drain size 90 mm 90% filter efficiency, filter element SS-304 Multi surface screen food grade and filter housing-UV stabilized HDPE with 10 year warranty complete all as specified and directed. |
| 61 | Item No. 30 : S&F for First flow flush system of 110 mm dia inclusive of T-Junction, Ball, sealing Ring, 1.5 mtr length of 110 mm dia PVC Chamber Pipe and end cap with Slow release drain valve, ball clamps and fitting Accessories. Complete all as specified and directed. Please Enable Macros to View BoQ information Schedule 'A' Part II (External Water supply) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 62 | Excavation in Trenches in soft loose soil n.exe 1.5m wide &1.5 m depth and getting out for taking out old unservieable water tubing or laying of new water tubing ,all as specified and directed. |
| 63 | Returning filling in including spreading leveling watering and well ramming in layer n exc 25 cm all as specified and directed. |
| 64 | Removing surplus soil to a distance n exc 50 mand depositing where directed at a level n exe 1.5 m above the starting point all as specified & directed. |
| 65 | Supply & fixing pipes galvanized medium grade and laid in trench complete including fittings of size 40 mm. |
| 66 | Supply & fixing pipes galvanized medium grade fixed to walls and ceilings or laid in floors fixed complete including fittings of size 20 mm |
| 67 | Supply and fix Bronze Gun-metal, globe or gate valves, with iron wheel head, screwedboth ends for iron pipe and fixed of size 40mm dia . |
| 68 | Supply and fix Bronze Gun-metal, globe or gate valves, with iron wheel head, screwedboth ends for iron pipe and fixed of size 20mm dia . Total carried over to BOQ Rs. 62774.4 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part-III (Demolition) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 69 | Demolition of brick work built in cement mortar including all quions, arches, pillars, etc complete. |
| 70 | Taking down Chowkhats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) |
| 71 | Taking down Chowkhats or frames exc 1.5 sqm not e xc. 4 sq. m each with shutters (without taking off shutters from the frames) |
| 72 | Dismantling timber scantlings as in framed work 40 sq. cm and over in section, in any position |
| 73 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings |
| 74 | Dismantling wrought Iron or mild steel work of any description not otherwise provided for all as spd and directed. |
| 75 | Dismantling of ceiling board with fittings and any description including cover fillets as directed. Total carried over to BOQ Rs. 77481.13 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part IV (External Electric supply) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 76 | Excavation in trenches n.exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose soil for laying of cables etc complete all as specified and as directed. |
| 77 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft / loose soil complete all as specified and as directed. |
| 78 | Removing surplus excavated soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 79 | Material and labour for sand filling in trenches with clean dry unwashed sand for cushioning of under ground cable in layers of 23cm thick (8 cm before laying the cable and 15 cm thick after laying the cable) including watering and consolidation, complete all as specified and as directed. Note : Punned thickness of sand will be measured. |
| 80 | Supply and laying of sub class B bricks laid flat adjacent to each other perpendicular to the direction of U/G cable all as specified and directed. |
| 81 | M & L for GI tube light grade ISI marked laid in trenches in road crossing or fixed on pole with clamp made out of MS flat 25 x 4mm with bolts, nuts and washer of suitable size for cable protection of size 80 mm dia complete all as specified and as directed. |
| 82 | Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 Sqmm 3.5 core. |
| 83 | All as per item No. above but 35 Sqmm 3.5 core. |
| 84 | Supply and fix 4 Pole MCCB 12 to 63 Amp,50 Hz, 415 V with rupturing capacity 25 KA |
| 85 | Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN and current carrying capacity 16 to 32 Amp in the DB complete with connection testing and commissioning. Total carried over to BOQ Rs. 290543.39 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part -V (Road Path Culvert) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 86 | Excavation over areas n.exc. 1.5m deep and getting out in any type of soil. |
| 87 | Rolling and consolidating formation surface in cutting on power roller exc 5 tonne & n exc 8 tonne |
| 88 | M&L laying and compacting 150 mm thick (compacted thickness) Granular Sub Base (GSB) grading as per Grade III as per table 900-1 of MoRTH specifications for Road and Bridge Works 2013 in a single layer over compacted subgrade with natural sand crushed gravel crush stone crushed slag or combination thereof as per the grading required. The material are mechanically mixed, spread and levelling on the subgrade by using motor gradetr of adquate capacity and rolling with vibratory roller of capacity 80-100 KN static weight for achieving required compaction density of atleast 98% of the Maximum Dry Density Consolidating to required gradient and camber complete all as specified and directed with finished surfaces tolerances as per Table 900-1 of MoRTH specifications for Road and Bridge works 2013 complete all as specified and as direceted. |
| 89 | M&L for 150 mm thick laying and compacting in two equal layers of 75mm each (compacted thickness) Wet Mix Macadam (WMM) grading as per table 400-13 of MoRTH specifications for Road and Bridge Works 2013 manufactured in WMM plant material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and consolidating to required gradient and camber complete all as specified and directed. |
| 90 | M&L applying evenly a prime coat of Cationic Bitumen Emulsion SS1 confirming to IS 8887 at a rate of application of 0.70-1 kg/sqm on surface of WMM/WBM as specified in Table 500-3 of MoRTH specification for road and bridge works 2013 using mechanical sprayer compl;ete all as specified and directed. |
| 91 | M&L for premixed bituminous macadam with 4% binder (paving bitumen,viscosity grade VG-10) contentby weight of total mix laid/rolled with 8 to 10 Ton power roller to required gradient and camber complete all as specified and directed. Note:- (i) cost of testing charges,materials andtranportations for Job mix formula shall be inclusive in the unit rate and no extra cost will be admissible on this account.(ii) Mix shall be obtained from hot mix plant and spreading shall be done by using Mechanical Paver. |
| 92 | M&L Bituminous premix dense asphaltic concrete 40mm consolidated thickness with 6% binder content by weight by total mix, rolled and compacted to required camber and gradient complete using VG-30 bitumen with cement as filler material, laying with mechanical paver and rolled with 8 to 12 ton power etc complete. |
| 93 | M & L for stone kerb of roughly squared stone (lime and sand stone) of size 30cm(length) x20 (height) x 50 mm thick all surfaces hammer dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 20 mm jointed in CM 1:6 and struck flush incl. necessary excavation returning filling in and removal of surplus soil etc complete all as specified and directed. |
| 94 | M&L for preparing bituminious surfaces of road and marking 2.5 mm thick centre lines, stop lines, dashes, arrows etc and the like n. exc 10 cm wide in roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed |
| 95 | Removal of excavated material soils to a distance exceeding 250m but n exc.500m and depositing where directed |
| 96 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose all as specified and directed |
| 97 | M & L for Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in subbase 100 mm thick |
| 98 | M&L for Moorum/red bajri filling, laid in layers n. exc. 15 cm thick, spread, levelled and rammed including watering as required complete all as specified and directed.Note : consolidated thickness shall be measured. |
| 99 | M&L Hard Core of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled/ rammed to a true surfce. |
| 100 | M&L for 80mm thick coloured machine pressed precast concrete interlocking paver block glossy finished any size and shape conforming to IS 15658-2006 , M-40 Grade with grey cement and pigment over stone dust filling complete all as directed. (Cost of Stone dust will be measured and paid separately) |
| 101 | M & L for Sand filling under floors or in foundations including wateringand consolidation complte all as specified. |
| 102 | Providing and laying at or near ground level factory made kerb stone of M25 grade cement concret in position to the required line, level and curvature, jointed with cement mortar 1:3 including making joint with or with out grooves including making drainage opening wherever required. |
| 103 | M&L for Concrete bed to drain pipes including packing under, and completely surrounding pipes with concrete after they are laid and tested in cement conrete 1:3:6 type C-2 around 450mm dia complete. |
| 104 | M&L for 450mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars all as specified and as directed. Total carried over to BOQ Rs. 3010579.09 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VI (Area Drainage) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 105 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 sqm on plan and n exc 1.50m in depth and getting out in any type of soil. |
| 106 | M&L for Cement concrete in surface channels and drains concrete type D-2 1:4:8 using 40mm graded aggregate in foundation and mass filling. |
| 107 | M&L for brick work withfly ash brick built in cement mortar (1:4) using curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 108 | M & L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work and finished even and smooth without using extra cement complete as specified and directed |
| 109 | M&L for PCC 1:3:6 type C-1 20mm graded stone aggregate in coping and like incl. weathering slightly rounded /chamfered angles with and incl. necessary use and waste of form work for fair faces of concrete complete all as specified and directed. |
| 110 | Returning, filling in any type of soil , including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 111 | Removal of excavated material soils to a distance exceeding 250m but n exc.500m and depositing where directed Total carried over to BOQ Rs. 459881.5 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VII (Sewage Disposal) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 112 | Excavating in trenches n exc 1.5m wide and n exc 1.5M depth for foundation in any type of soil and getting out. |
| 113 | M&L for PCC 1:3:6 Type C-2 (using 40mm graded stone agg) as in foundation/mass concrete filling etc all as specified. |
| 114 | M&L for brick work built in cement mortar (1:4) using fly ash bricks straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 115 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone agg) as in Man hole channel and surface drain slightly rounded or chamfered angles etc complete all as specified. |
| 116 | Extra for Forming fair finished channel 30 cm inner girth in cement concrete using extra cement including mitered stopped ends etc complete. |
| 117 | M&L for rendering 15 mm thick in CM 1:4 with water proofing compound on fair faces brick work or concrete surface etc all as specified. |
| 118 | Supplying only integral water proffing compound ISI marked |
| 119 | M&L for Concrete bed to drain pipes including packing under, and completely surrounding pipes with concrete after they are laid and tested in cement conrete 1:3:6 type C-2 around 150mm dia complete. |
| 120 | Removing excavating soil exc 50 M and n. exc 100m depositing where directed at a level n exc 1.5M above the starting point. |
| 121 | Returning , filling in, including spreading,leveling,watering and well ramming and layers n exc 25 cm thick in hard/dense soil etc,complete. |
| 122 | Form work to soffit of slab n.exc 200mm thick. |
| 123 | Form work to edges of concrete flats exc 10cm but n.exc 20 cm Total carried over to BOQ Rs. 140245.37 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VIII (Security Compound wall and Gate) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 124 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cmdeep and getting out in soft / loose soil all as specified and directed |
| 125 | Excavation in trenches n. exc. 1.5 m wide and not exceeding 1.5 m in depth, for foundation, etc or for shafts, walls, cesspits, manholes, pier holes, etc getting out in any type of soil, complete all as specified and as directed. |
| 126 | Excavation in trenches n. exc. 1.5 m wide and not exceeding 1.5 m in depth, for foundation, etc or for shafts, walls, cesspits, manholes, pier holes, etc getting out in soft /disintegrated rock, complete all as specified and as directed. |
| 127 | Material and Labour for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation, mass concrete etc complete all as specified and as directed. |
| 128 | Material and Labour for Reinforced cement concrete M-25 (Design mix) using 20mm graded stone aggregates as in foundation, including raft, footings foundation beams, plinth beams, bases for columns, basement slabs and like that complete all as specified and as directed. |
| 129 | All as per Sl. Item No. 5, here in before but as in columns. |
| 130 | All as per Sl. Item No. 5, here in before but as in beams. |
| 131 | M & L for Use and waste formwork to side of concrete foundation, footings bases of columns, sides and soffits of plinth beams for rough finished flat surfaces complete all as specified and as directed. |
| 132 | All as per Sl. Item No. 8, here-in-before but as to side of columns. |
| 133 | All as per Sl. Item No. 8, here-in-before but as to sides and soffits of beams. |
| 134 | Material and Labour for TMT bars 10mm dia and over dia cut to length, bent to shape required, including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 9mm dia or securing with clips complete all as specified and as directed. |
| 135 | All as per sl. Item No. 11, here-in-before but for 5 to 10mm dia bars as in stirrups, spacers and like that. |
| 136 | M&L for brick work built in cement mortar (1:6) using fly ash bricks straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 137 | Material and Labour for PCC 1:3:6 type c1 using 20mm graded stone aggregate as in coping including necessary formwork complete all as specified and as directed. |
| 138 | Material and Labour for rendering in CM 1:6, 15mm thick on fair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified and as directed. |
| 139 | Material and Labour for applying two coats cement base paints over one coat of alkali resistant priming paint on newly plastered wall surfaces including preparation complete all as specified and as directed. |
| 140 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm in soils complete all as specified and as directed. |
| 141 | Removal excavated material to a distance exc 250 but not exceeding 500 M and depositing where directed at a level n. exc. 1.5 m above starting point as in soils complete all as specified and as directed. |
| 142 | Supplying and Fixing of PVC (SWR) single sockted 110 mm bore of pipes as in weep holes of compound wall complete all as specified and as directed |
| 143 | S &F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted,or forged into spikes framed guard bars; barred iron doors ladders framed balusters; walk ways; railings; framework ofwater tanks and similar work conforming to Fe.290.Gde-E-165 |
| 144 | M & L for Two coats of synthetic enamel paint over primer with preparation of steel surface Total carried over to BOQ Rs. 1837187.99 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part IX (Rain Water Harvesting) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 145 | Earthwork in excavation by mechanical means over area in any, kind of soil (exceeding 30 cm deep 1.5 m in width as well as exceeding 10 Sqm in plan area) including getting out and disposal of excavated earth lead up to 50 m and lead upto 1.5m complete all as specified and as directed. |
| 146 | M&L for coarse sand filling under floors or in foundations including watering and consolidation. |
| 147 | Precast RCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in cover slab and similar work including necessary formwork set in cm 1:4 complete. |
| 148 | M&L for mild steel bars 10mm dia & over cut to length bent to shape required including, cracking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than0.90mm dia or securing with clips, quality confirming to TMT bars. |
| 149 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified. |
| 150 | Removing excavated material exc 250m but not exc 500 m and depositing where directed by Engr-in-charge at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 151 | S&F 75 mm bore UPVC Pipes (SCH-40) with and including all fittings and laid in walls or floors complete all as specified and directed. |
| 152 | S&F PVC pipes of 110 mm dia laid in down take pipe all as specified and directed.Note : Necessary bends, connectors etc are not measured separately. The length shall be measured overall) |
| 153 | S&F PVC underground water storage tank of 5000 Ltr capacity. Total carried over to BOQ Rs. 315085.97 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part X (Refrigeration and Air Conditioning) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 154 | Supply, installation, commissioning of energy efficient water cooler fully stainless steel, electric dirven single phase having approx storage and nominal cooling capacity 150/150 Ltrs with all arrangement etc complete all as specified and directed. Total carried over to BOQ Rs. 66544.45 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XI (Hot Water Supply & Solar Hot Water ) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 155 | Supply, Installation, Testing and commissioning of Solar Hot Water System with three layered evacuated glass tubes (ETC) as a solar collector, of capacity 200 LPD inner tank made of stainless steel, outer tank powder coated galvanized/SS, insulation fiber glass wool with electrical backup 2.0/ 3.0 KW with NRV, connecting accessories alongwith structure and its fixing arrangement as per OEM recommedation complete all as specified and directed. |
| 156 | Supply and fixing Gl tubing medium grade 25mm bore with fitting and connected items connecting with Rotational moulded PVC water storage tank as inlet and outlet for backup stainless steel hot water tank complete all as specified and directed. |
| 157 | Supply & lay Hot water pipe duly inslulated with glass wool and aluminium cladding 15 mm bore complete all as specified and directed. |
| 158 | Supply & lay Hot water pipe duly inslulated with glass wool and aluminium cladding 20 mm bore complete all as specified and directed. |
| 159 | Supply and fixing Stop valves 25 mm , chromium plated fancy type cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and connected items all as specified and directed. |
| 160 | Supply and fixing Stop valves 20 mm , chromium plated fancy type cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and connected items all as specified and directed. |
| 161 | S&F Rotational moulded PVC water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position of capacity 1000 ltrs with suitable size angle iron stand , height of the stand suitable for solar water heater of capacity 250 LPD (nearest higher standard size) complete all as directed at site. |
| 162 | S&F sheet metal enclosures single pole and neutral 2 way, 240 volt with 200 Amp rated bus bar for DBs complete all as specified and directed . |
| 163 | S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 volts breaking capacity 10 KA, C curve characteristics complete all as specified and as directed. |
| 164 | M&L Cross arms, bracings,supports,clamps and back plates fabricated from new structural steel sections including nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts in any shape or size as indicated or directed by Engr-in-Charge and inclusive of one red oxide metal primer coat,one under coat and one finishing coat of approved quality aluminium paint.Note :- Structure for PVC water tank should be as per standard engineering design and MS sheet shoul be fixed/welded on the top of structure for placing the PVC Tank. contractor has to vetted the structuctre from any govt engineering college and duly approved by MES. |
| 165 | S&F of concealed sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor cable of size 10.00 sqmm LT, 1100 volts grade, drawn through and including 25 mm dia PVC non metallic open conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 10 sqmm single core multistranded copper conductor cable green colour as earth continuity conductor. complete all as specified and as directed. Note:- (i) Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 25mm dia shall be measured as one run lenght. (ii) Cable required for connection to DBs shall deemed to be included and shall not be measured seperately. (iii) Earth wire shall run inside the PVC conduit. Total carried over to BOQ Rs. 291156.86 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XII (Lift) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 166 | Design supply, install testing & commissioning passengers lift of capacity 8 passanger (544 Kg), speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS14665, suitable to serve G + 03 upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, Car Size- as per IS and suitable to install in lift well,Door Size- as per IS or manufacture specification, automatic rescue device (ARD) system with suitable UPS and Battery Bank system with complete connected acessories deemed to be included as part of safety feauture, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) & human interface device, all other Finishes Standard safety features should be as per IS specification and modern practices in market in lift complete all as specified below :- (i) Contractor shall be submit detailed construction drawing of lift being provided with complete technical specification as per IS : 14665 (Including all ammendments till date) before dispatch the of material from OEM for approval of GE. (ii) The scope of work also covered the all civil works, car and counter weight guide rails, brackets, terminal buffer support and sil angle, plates and any other items required for successful completion of lift with respeect to safety required by OEM, and any other supprting structure required will be carried out by contractor without any extra cost If any clearance required from state government i.e lift inspector/ electrical safety department/ fire safety departments is the contractor's responsibility & any expenditure on this account shall be deemed to be included in the quoted rates. (vi) Any other component which are left out, but essentialiy required as per OEM's design, shall be provided without any extra cost.(vii )Lift technician shall be provided for 24X7 period including Sunday and holiday by the contracor for its functioning, operation or any issue arising in the lift during defect liability period. Any maint /replacement of any items during defect liability period will be borne by he contractor.(viii) Lift shall be taken over after inspection of lift by Sr IEM and all Mandatory test/fitness obtain from OEM consequent upon all satisfactory results. |
| 167 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 core x 25 sq mm complete all as specified (for lift supply) |
| 168 | S & F for MCCB adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu rating 63 Amps 16KA and including sheet steel. The enclosure shall be wall mounted with and including all fixing accessories complete all as specified. |
| 169 | S & F for Galvanised iron strip of size 25 mm x 4 mm for earth contunity conductor complete all as specified and directed. Total carried over to BOQ Rs. 2242540.92 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part XIII (Site development) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 170 | Surface excavation n. exc. 30 cm deep and averaging 15 cm deep and getting out Hard/dense soil complete all as specified and as directed. |
| 171 | Removing excavated material/soil to a distance exceeding 1.5 km but not exceeding 5.00 km and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 172 | Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, amming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base complete all as specified and as directed. |
| 173 | Grubbing up tree trunk including cutting of trunk portion protruding over ground, girth of tree exc 30 cm but n.exc 100 cm digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site complete all as specified and as directed. Total carried over to BOQ Rs. 205656.3 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part-XIV (Internal Electrification) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 174 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with mudular metal box min 1.2mm thick, duly covered with modular white colour plate with frame and other necessary accessories ncluding PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- Note :- a) One circuit should have maximum up to 8 points .b) Circuit wire from MCB to switch board is deemed to be included with unit rate of item point wiring and the size of circit wire should be 2.5 sqmm for L, N, Earth point .c) Core coding for phase wires are RYB maintain, for neutral black colour and for Earth Green (a) One light point controlled by one, one way switch 5 Amps Point 992.75 226.0 224361.5 (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator Point 992.75 73.0 72470.75 (c) One light point controlled by one, two way switch 5 Amps Point 1397.96 16.0 22367.36 (d) One bell point controlled by one, bell switch 5 Amps Point 992.75 24.0 23826.0 (e) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. Point 284.1 48.0 13636.8 (f) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. Point 1070.4 73.0 78139.2 |
| 175 | Description all as per item No 1 here in before but using 2.5 sq mm single core copper conductor two nos cables of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.Note :- a) Circuit wire from MCB to switch board is deemed to be included with unit rate of item point wiring and the size of circit wire should be 4.00 sqmm for L, N, E |
| 176 | Description all as per item No 1 here in before but using 4 sq mm single core copper conductor two nos cables of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for industrial socket point including necessary running of 4 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. Note connections to be drawn for segregated 4 way DBs in each dwelling unit for Ac and Geyser points .Note :- (a) Circuit wire from MCB to switch board is deemed to be included with unit rate of item point wiring and the size of circit wire should be 4.0 sqmm for L, N, E |
| 177 | S & F ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete. |
| 178 | S & F modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 179 | S & F modular switch piano flush type, single pole, two way, and 5/6 Amp single module complete all as specified. |
| 180 | S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 181 | S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 182 | S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 183 | S & F Bell push modular 6 Amps single module complete all as specified. |
| 184 | S & F Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed |
| 185 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit .Note:- Each dwelling unit two separate ciruits catered . |
| 186 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 187 | S & F for Tripper RCBO (EL+MCB) of rating 25 Amps,DP, 10 KA, C curve , 4 M , 100mA (nearest standard size ) 240 Volts , protection against over currents, short cuircuit and earth leakage faults As per IS 12640-2 & IEC 61009-1complete all as specified and as directed by Engineer -in Charge .Make :- Make :- L&T( Lauitz Knudsen), SIEMENS, , Schiender |
| 188 | S & F for MCB Single pole rated capacity 6-32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 189 | Supply and fixing ceiling fans complete with blades, down rods, electronic remote controlled regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.0 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 190 | S & F for energy efficient exhaust fan of 250 mm sweep 1200 RPM, with copper winding made of sturdy Engineering plastic ; flow rate not less than 860 CMH made of plastic body complete with louver shutter , with bolts nuts and washers, bolt , embedded on the wall including provision of PVC flexible copper cable three core from ceiling rose to exhaust fan for connection, complete with Louvers shutter and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. |
| 191 | S & F for wall mounted LED tube light fitting 1x 10 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting,luminous efficiency not less than 120 lumen/watt, CRI > 80% , THD < 30% , driver Efficiency > 85% , PF > 0.9. Correlated Color Temperature 6500K (cool daylight) 170 Volts to 230 volts and LED Chip, Diver and Housing should of same make with warranty option of 2 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor and flexible conduit of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.Make : Philips or equivalent in OSRAM/GE |
| 192 | S & F for wall mounted LED tube light fitting 1x 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting,luminous efficiency not less than 120 lumen/watt, CRI > 80% , THD < 30% , driver Efficiency > 85% , PF > 0.9. Correlated Color Temperature 6500K (cool daylight) 170 Volts to 230 volts and LED Chip, Diver and Housing should of same make with warranty option of 2 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor and flexible conduit of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.Make : Philips or equivalent in OSRAM/GE |
| 193 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts(or nearest standard size) , luminous efficacy not less than 110 lumen/watt, LED Chip, Diver and Housing should of same make with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make : Philips or equivalent in OSRAM/GE |
| 194 | M & L for earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 3 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-1 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe and 15 mm dia GI pipe for protection of GI wire up to 7.5 mtr connected to earthing point complete all as specified and as directed. Total carried over to BOQ Rs. 1485403.46 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part-XV (Internal Water Supply) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 195 | Supplying and laying of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings (incl all fittings i.e. elbow tee & other connected fitiings fixing with solution/ solvent cement) of 16 mm dia on walls/ceilings for laying in floors complete all as specified |
| 196 | Supplying and laying of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings (incl all fittings i.e. elbow tee & other connected fitiings fixing with solution/ solvent cement) of 20 mm dia on walls/ceilings for laying in floors complete all as specified |
| 197 | Supplying and laying of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings (incl all fittings i.e. elbow tee & other connected fitiings fixing with solution/ solvent cement) of 25 mm dia on walls/ceilings for laying in floors complete all as specified |
| 198 | S&F Bib tap 15mm bore fancy type chromium plated , cast copper alloy with crutch or butterfly handle screwed down for iron pipes all as specified and as directed. |
| 199 | Supply and fix 15mm dia pillar taps swan neck cast copper alloy chromium plated ,but fancy type screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks & fly nuts screwed for iron pipe (bore of pipe 15mm) |
| 200 | S&F Brass CP Wall mixerthree hole incl provn of shower rose inlet 15 mm dia formixing hot & cold water screwed down for iron pipe and fixed complete all as spd and directed. |
| 201 | S&F 15mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed but fancy type, chromium plated with long shank and cup(concealed type) |
| 202 | S&F 15mm Angle valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed but fancy type, chromium plated with long shank and cup(concealed type) |
| 203 | S&F Ball brass valves, high pressure, with polythene float & steel rod & fly nut complete, screwed for iron pipe or brass ferrule and fixed 20 mm bore pipe . |
| 204 | S & F 20 mm dia ball valve with iron wheel head screwed both for CPVC pipe and fixed |
| 205 | S & F 20 mm dia ball valve with iron wheel head screwed both for CPVC pipe and fixed |
| 206 | S & F 25 mm dia ball valve with iron wheel head screwed both for CPVC pipe and fixed |
| 207 | Supply and fix PVC connection 15mm size with PTMT nut of length 450 mm |
| 208 | S&F for Brass chromium plated shower rose 125mm size Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union. |
| 209 | Supplying and laying of brass elbow for CPVC pipes of 16 mm outer diameter walls/ceilings for laying in floors complete all as specified |
| 210 | Supplying and laying of brass Tee for CPVC pipes of 16 mm outer diameter walls/ceilings for laying in floors complete all as specified |
| 211 | Supplying and laying of Male brass threaded adaptor for CPVC pipes of 16 mm outer diameter walls/ceilings for laying in floors complete all as specified |
| 212 | Supplying and laying of Female brass threaded adaptor for CPVC pipes of 16 mm outer diameter walls/ceilings for laying in floors complete all as specified Total carried over to BOQ Rs. 1108881.8 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail