| 1 | Dewatering of septic tank and soakage well and manholes of any depth in any position by pumping out and removing outside Militery/Defence land by meachanical means (trolly mounted) and burying in pits all as directed including digging of pits in any type of soil nand covering pits with eart after absorption of water and including providing and spreding required quantity of bleaching powder around the pit and dispose of waste material as per state material as per state protocol and washing the top of septic tank and soakge wells and surround with fresh water and sprinkling lime to make hygenic, complete all as specified and as directed by Engr-in-Charge. |
| 2 | De-Sludging of septic tank of any capacity including connected intercepting chamber manhole shaft, sludge chamber & filter beds of any description and in any in any position by pumping out and removing outside Militery/Defence land by meachanical means (trolly mounted) and burying in pits all as directed including digging of pits in any type of soil and covering pits with earth after filling of sludge and including providing and spreading required quantity of bleaching powder around the pit and dispose of waste material as per state material as per state protocol and washing the top of septic tank and soakge wells and surround with fresh water and sprinkling lime to make hygenic , including taking down of slabe cover and placing the same in existing position, complete all as specified and as directed by Engr-in-Charge. |
| 3 | Providing of a sweeper for 08 working hours for the work of cleaning of SGSW/CI pipe line up to the dia of 300 mm fixed to wall/floor any position and cleaning of blockage from water closet(Indian or Eurpean), trap, Floor/Nanhi trap of kitechen/Bathroom by by rodding, pumping, etc and the work all as specified and directed.NOTE :-(i) The rates quoted in the above item includes cost of T&P likd rods, bamboos and other safety devices etc complete.(ii) Contractor shall deployed sufficient number of persons as per requirement /as decided by Engineeer-in-Charge who shall be present on all working days from 0900 hrs to 1700 hrs for maintenance of sewage lines. The persons will be detailed by JE / AGE concerned every morning for attending complaints on daily basis.(iii) Complaint shall be rectified within 06 hours in receipt of complaint. A sum of Rs. 250/- per complaint per day will be recovered from payment of contractor if the complaint is not cleared with 24 hours. |
| 4 | Providing of a mazdoor man, 18 years and above for 08 working hours for the for to assist and help of sweeper as work of cleaning of SGSW/CI pipe line up to the dia of 300 mm fixed to wall/floor any position and cleaning of blockage from water closet(Indian or Eurpean), trap, Floor/Nanhi trap of kitechen/Bathroom by by rodding, pumping, etc and the work, complete all as specified and directed.Note :-(i) The rates quoted in the above item includes cost of T&P likd rods, bamboos and other safety devices etc complete.(ii) Contractor shall deployed sufficient number of persons as per requirement /as decided by Engineeer-in-Charge who shall be present on all working days from 0900 hrs to 1700 hrs for maintenance of sewage lines. The persons will be detailed by JE / AGE concerned every morning for attending complaints on daily basis.(iii) Complaint shall be rectified within 06 hours in receipt of complaint. A sum of Rs. 250/- per complaint per day will be recovered from payment of contractor if the complaint is not cleared with 24 hours. |
| 5 | Excavation in trenches in hard/dense soil n. exc 1.5m wide and n. exc 1.50m deep and getting out, complete all as specified and directed |
| 6 | Excavation over areas in hard/dense soil n exc 1.5 m deep and getting out, complete all as specified and directed. |
| 7 | Excavation over areas in hard/dense soil exc 1.5 m but n exc 3.00 m deep and getting out, complete all as specified and directed. |
| 8 | Returning filling in incl spreading, levelling, watering and well ramming in layers n.exc 25 cm thick, complete all as specified and directed. |
| 9 | Removing excavated materials to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed. |
| 10 | M & L for salt glazed stone ware drain pipe grade 'A' , laid in trenches and jointed in CM, internal dia of pipe 150 mm incl providing concrete bed to drain pipes 150 mm dia (SGSW) in cement concrete (1:3:6) Type D-2 including packing under and haunching against the sides of pipe after they are laid and tested, complete all as specified and directed. |
| 11 | S&F for reinforced concrete pipes class, NP-2, laid and jointed complete with collars 200mm bore of pipe incl providing concrete bed to drain pipes 200 mm dia (RCC) in cement concrete (1:3:6) Type D-2 including packing under and haunching against the sides of pipe after they are laid and tested, complete all as specified and directed. |
| 12 | M&L for 100 mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) as in flooring, complete all as specified and directed. |
| 13 | M&L for forming 12mm thick expansion joints of150mm thick filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, grade 'A', complete all as specified and directed. |
| 14 | S&F in repair for 35 mm thick precast PCC louvers and jallies in 1:2:4 type B-0 (Using 12.5mm graded crushed stone aggregate) incl suitable reinforcement all moulding etc set in CM 1:4, complete all as specified and directed. |
| 15 | M & L for non skid Heavy duty endura tile 300x300x10-12mm thick joint free in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed in cement mortar 1:4 complete, incl Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), rubbish off the premises, complete all as specified and directed. |
| 16 | M & L for Chequered cement concrete tiles pre polished 30cmx30cmx22-25mm thick, set ,jointed and pointed in neat cement slurry with grey cement and pigment in floors.incl over 20mm thick screed bed or bedding layer in CM 1:6, complete all as specified and directed. |
| 17 | Supply and fixing in repair Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; over incl M&L 75 mm thick PCC (1:4:8 TYPE D-2) using 40mm graded aggregate as in sub base of floor, complete all as specified and directed. |
| 18 | Supply and fixing in repair Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; M&L 100 mm thick PCC (1:4:8 TYPE D-2) using 40mm graded aggregate as in sub base of floor, complete all as specified and directed. |
| 19 | S&F in repair for PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in foundation of man hole, complete all as specified and directed. |
| 20 | M & L for RCC type B1 1:2:4 (using 20mm graded crushed stone aggregate) as in slab for roofs, landing, balconies , canopies, deck slabs and in shelves Demolition of cement concrete (reinforced) n.exc as in man hole cover and the like, complete all as specified and directed. |
| 21 | Use and waste of form work to soffits of suspended slabs such as roof , floor slabs, landing or similar work, n.exc 200mm thick (horizontal or sloping), flat rough finished, complete all as specified and directed. |
| 22 | S & F for TMT bars 10mm dia and over, cut to length, bent to shape required incl cranking bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire not less than 0.9 mm dia or securing with clips, complete all as specified and directed. |
| 23 | All as per item No 22 here-in-before but 6 to 8 mm dia, complete all as specified and directed. |
| 24 | M & L for broken brick bat 40 to 80mm loose filling in soakage pits/filter beds etc, complete all as specified and directed. |
| 25 | Cutting in to existing manholes/outlet chamber of safety tank for connecting drain pipes making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 smooth finished and reforming benching as required, for 150 mm internal bore pipe, complete all as specified and directed. |
| 26 | Demolition of brick or stone masonry, built in cement mortar incl all quoins, pillars, arches etc but excluding ashlar facing, complete all as specified and directed. |
| 27 | M&L for brick work with Sub class 'B' brick straigth or curved on plan exc. 6m mean radius built in cm 1:6, complete all as specified and directed. |
| 28 | M&L for reuses brick work with Sub class 'B' brick straigth or curved on plan exc. 6m mean radius built in cm 1:6, complete all as specified and directed. Note: bricks obtain from item No 27 above. |
| 29 | Taking down Cement plaster on brick or stone walls incl raking out joints hacking for key & scrubbing down with water etc, compplete all as specified and directed. |
| 30 | M&L for rendering 15mm thick in cm (1:6) on other than fair faces of brick work or concrete surfaces finished & even and smooth without usnig extra cement, Taking down Cement plaster on brick or stone walls incl raking out joints hacking for key & scrubbing down with water incl preperation of new plastered surfaces wall applying two coats of cement base paint over one coat of primer, complete all as specified and directed. |
| 31 | M & L for preperation of new plastered surfaces wall applying two coats of cement base paint over one coat of primer, complete all as specified and directed. |
| 32 | M&L for rendering 15mm thick in cm (1:6) on other than fair faces of brick work or concrete surfaces finished & even and smooth without usnig extra cement, complete all as specified and directed. |
| 33 | M & L for preperation of new plastered surfaces wall applying two coats of cement base paint over one coat of primer, complete all as specified and directed. |
| 34 | M&L for Prepration of old plastered surfaces of wall and applying one coats of cement base paint incl preparation of old plastered surfaces, complete all as specified and directed. |
| 35 | M&L for Prepration of old plastered surfaces of wall and applying one coats of Appx exterior emulsion paint (Asian paint) incl preparation of old plastered surfaces, complete all as specified and directed. |
| 36 | Demolition and breaking up drain pipes up to 150mm dia (SGSW/AC/PVC or reinforced concrete pipe) set in cement mortar incl concrete bed to drain pipes, complete all as specified and as directed. |
| 37 | S & F in repairs PVC (SWR) pipes 110 mm bore single socketed, in any length, with rubber ring joints, laid in trenches or under floors, inserted in retaining wall etc, complete all as specified and directed. |
| 38 | All as per item No 37 here-in-before but bore of pipe 75 mm, complete all as specified and directed. |
| 39 | S & F in repairs PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls etc, complete all as specified and directed. |
| 40 | S & F in repairs PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls etc, complete all as specified & directed. |
| 41 | S&F in repair 110 mm dia PVC (SWR) bends with access door, complete all as specified and directed. |
| 42 | S&F in repair PVC (SWR), junction single, (Single T) equal or unequal with access door 110 mm bore, complete all as specified and directed. |
| 43 | PVC (SWR), junction single, (Single T) equal or unequal with access door 75 mm bore, complete all as specified and directed. |
| 44 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. Please Enable Macros to View BoQ information |