Tender For Repair/ Maintenance Of External Water Supply Day To Day Complaints And Old Rusted Gi/Ci Pipe Lines Of Water Supply Distribution Network & Certain Other Allied Work Of Water Supply Service For Building And Pump House At Varunapuri, Dcra, Uw
Tender Overview
Project Description
Tender for Repair/ Maintenance Of External Water Supply Day To Day Complaints And Old Rusted Gi/Ci Pipe Lines Of Water Supply Distribution Network & Certain Other Allied Work Of Water Supply Service For Building And Pump House At Varunapuri, Dcra, Uwr And Map Buildings Under Age E/M-Ii Of Ge (Nw) Vasco (Tender Id No : 2026_Mes_733184_1)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-Jun-2026 | Revised Tender Pages | Other | 10-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | M & L for MS Special fitting of IS 1239 and wall thickness not less than 5mm any type spigot and socket ends or flanged pipe as required at site (such as bend, taper, Tee, flange, socket etc) Socket end/ flanged as ordered of any size from 80mm to 300mm as required at site including painting with one coat of red oxide primer and 2 coats of acrylic paint complete all as specified and directed.Note: (i) The weight of the fittings shall be measured and paid as given in relevant IS or actually provided whichever is less.(ii) All fittings shall bear relevant IS stamping marking and most adhere to the IS.(iii) Excavation and earth work shall be measured and paid separately under respective item of BOQ.(iv) Cost of the joints and jointing materials shall be deemed to be included in the relevant items of DI pipes here-in-before. |
| 2 | Supply and fix PTMT float valve of following sizes, with epoxy coated aluminium rod and high density plastic ball complete all as specified and as directed. |
| 3 | PTMT float valve, 20 mm bore |
| 4 | PTMT float valve, 25 mm bore |
| 5 | PTMT float valve, 40 mm bore |
| 6 | Supply and fix in repairs Gun metal gate valve, with iron wheel head screwed both ends for iron pipe as per IS-778 and fixed including taking out unserviceable one, complete all as specified and as directed of following sizes. |
| 7 | Gun metal gate valve, 20 mm bore |
| 8 | Gun metal gate valve, 25 mm bore |
| 9 | Gun metal gate valve, 40 mm bore |
| 10 | Gun metal gate valve, 50 mm bore |
| 11 | Taking up or down GI/CPVC tubing of following sizes with connections from Trenches/floors/walls including cleaning for removal complete all as specified and as directed.Note :- Excavation & earth work shall be measured & paid separetely under respective item of this schedule.. |
| 12 | 20 mm bore |
| 13 | 25 mm bore |
| 14 | 40 mm bore |
| 15 | 50 mm bore |
| 16 | 80 mm bore |
| 17 | 100 mm bore |
| 18 | 150 mm bore |
| 19 | Supply & laying GI Tube medium grade with all fitting (tee, union, elbow, socket) , flanges,nut & bolts laid in trenches complete of the following size |
| 20 | 20 mm bore |
| 21 | 25 mm bore |
| 22 | 40 mm bore |
| 23 | 50 mm bore |
| 24 | 80 mm bore |
| 25 | Supply & Laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 with all plain fittings such as elbow, bend, socket, nipple, union, MT,FT and Reducer socket etc fixed to wall, ceiling or floor for following bore of pipes.Note: if the CPVC pipe is requiired to be laid in trenches the excavation and return filling will be measured and paid seperately under relevant schedule item. |
| 26 | 20 mm outer dia |
| 27 | 25 mm outer dia |
| 28 | 40 mm outer dia |
| 29 | 50 mm outer dia |
| 30 | S & F CPVC ball valves and connected items suitable to connect with CPVC pipes of following sizes complete including taking downn old unserviceable valves of any type all as specified and directed. |
| 31 | 20 mm bore |
| 32 | 25 mm bore |
| 33 | 40 mm bore |
| 34 | 50 mm bore |
| 35 | Supply and Fixing in replacement C.I Ball type foot valve flanged in UG sump of any capacity by carefully disconnecting suction pipe of motor and reconnecting after replacement of foot valve by replacing any unserviceable nut and bolts and rethreading/ welding flange works etc if necessary, complete all as directed by engr-in-charge including taking down the old foot valve of any type and following sizes. |
| 36 | 150 mm bore |
| 37 | 100mm bore |
| 38 | Supply and Fixing in replacement Brass foot valve threade type in UG sump of any capacity by carefully disconnecting suction pipe of motor and reconnecting after replacement of foot valve by replacing any unserviceable nut and bolts and rethreading/ welding flange works etc if necessary, including taking down the old foot valve of any type complete all as directed by engr-in-charge for following sizes. |
| 39 | 50 mm to 65 mm bore |
| 40 | 80 mm to 100 mm bore |
| 41 | Supply and fix in repairs for bib tap standard of PTMT any colour of size 15mm high pressure screwed for iron pipe or with suitable fittings to fix with existing CPVC pipe including taking down old u/s complete all as specified and directed. |
| 42 | M & L Lead wool joints suitable for spigot & socketed CI Pipes and caulking the joints properly for avoiding leakage etc for the following sizes as directed :-Note: Excavation if required shall be measured and paid seperately |
| 43 | 200mm bore size |
| 44 | 150mm bore size |
| 45 | 100mm bore size |
| 46 | Supply, laying, jointing and testing in trenches 100 mm bore size DI pipes class K-9 of standard length spigot and socketed end push type joint with rubber gasket as jointing material , internal cement morter cutting and external surface with bituminious paint ISI marked complete all as specified & directed. |
| 47 | Supply and fix in repairs CI special fittings for spigot and socketed pipes such as bbends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot)collars, caps and plugs all as per IS:1538 complete upto 150mm dia all as directed by Engineer-in-charge. |
| 48 | M/L providing cement concrete type B2 (1:2:4) using 40mm graded stone aggregate as in foundation, filling in mass concrete, making good the road cutting etc including levelling existing surface and cleaning surrounding area by removing any existing grass and bushes etc complete all as specified and directed. |
| 49 | S&F Cast iron detachable long joint (CID) / tapping saddle joint clamp with suitable tapping including cutting, cleaning, preparing pipe surface complete for the following sizes of pipes:- |
| 50 | (a) 200 mm dia bore |
| 51 | (b) 150 mm dia bore |
| 52 | (c) 100 mm dia bore |
| 53 | S&F in replacement Sluice Valve CI class PN 1.6 flanged type 80mm, ISI marked with Hand Wheel for operation, Non- Rising SS stem, bronze body seat ring, ISI marked as per IS 1538 including all minor fixing arrangementcomplete all as specified and directed. |
| 54 | All as per item No-16 above but of size 100mm bore sluice valve |
| 55 | All as per item No-16 above but of size 150mm bore sluice valve |
| 56 | All as per item No-16 above but of size 200mm bore sluice valve |
| 57 | Providing services for collection of filtered potable water sample from various point of C Zone area periodically or as and when directed by following standard procedure of sample collection, taking sample safely to Govt Approved Lab to carry out Water Testing for Chemical & Biological Analysis and submit the report within stipulated time period complete all as specified and directed. |
| 58 | Providing services for welding/ jointing of GI/MS pipe of any size for any alteration or arrest leakage by using electric arc welding including all necessary patch material including necessary excavation and refilling of spoil complete all as specified and directed. Please Enable Macros to View BoQ information |
| 59 | Providing services for welding/ jointing of GI/MS pipe of any size for any alteration or arrest leakage by using electric arc welding including all necessary patch material including necessary excavation and refilling of spoil complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender