| 1 | M&L for point wiring as per colour coding with 1.5sqmm FRLSH cable PVC insulated unsheathed with stranded copper conductor cable drawn in and including 19mm thick rigid non metallic PVC concealed conduit medium grade with all standard fittings including Cutting chases, pinning in making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring and making good, cutting not exceeding 10cm girth, and removal of rubbbish outside premises and providing new sunken terminal boxes and cover for mounting modular switch/ sockets etc. including PVC insulated unshearthed 1.5 sqmm multistranded copper conductor cable FRLSH colour code cable 1100 volts grade for earth continuity including taking down old copper/ aluminium point wiring (light, fan, socket or power) complete from existing concealed/ surface conduits/ casing capings etc and making good disturbed surface of walls, floors, etc. for the One light/fan point controlled by one switch, complete all as specified and directed.Note : Sunken box and cover plates required shall be measured and paid separately under respective item. |
| 2 | M&L for point wiring as per colour coding with 1.5sqmm FRLSH cable PVC insulated unsheathed with stranded copper conductor cable drawn in and including 19mm thick rigid non metallic PVC concealed conduit medium grade with all standard fittings including Cutting chases, pinning in making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring and making good, cutting not exceeding 10cm girth, and removal of rubbbish outside premisesand providing new sunken terminal boxes with new 3 mm thick PVC laminated sheet for mounting piano type switch/sockets etc and incl 1.5 Sqmm multi stranded copper conductor PVC insulated unshearthed FRLS colour code cable 1100 volts grade for earth continuity including taking down copper/aluminium point wiring (light, fan, socket or power) complete, including conduits/casing caping etc and making good disturbed surface of walls, floors, etc for the One light/fan point controlled by one switch, complete all as specified and directed.Note : The unit rate includes Sunken box and 3 mm thick PVC laminated sheet. |
| 3 | S&F in replacement modular switch 1 way 6 A, 1 module all as specified and directed. |
| 4 | S&F in replacement concealed type flush mounted GI sheet metal box 18 gauge thickness suitable for mounting modular switch/ sockets complete with fixing plate and cover plate with frame, with earthing terminal and good quality thread including making good the disturbed surfaces complete all as directed for the for One/two module. |
| 5 | S&F in replacement of switch piano type, flush type, single pole, one way, 6 Amps complete all as specified and directed. |
| 6 | S&F in replacement MCB SP 240 volts 6 to 32 Amps, 10KA, 'B' curve type all as specified and directed. |
| 7 | S&F in replacement MCB SPN 240 volts 40 to 63 Amps, 10KA, ‘B’ curve complete all as specified and directed. |
| 8 | S&F in replacement DB sheet metal enclosure double door for MCB’s company made, SPN 240 Volts 12 ways with IP 42 protection with 200 amps rated bus bars complete all as specified and directed. |
| 9 | S&F in replacement DB sheet metal enclosure double door for MCB’s company made, SPN 240 Volts 8 ways with IP 42 protection with 200 amps rated bus bars complete all as specified and directed. |
| 10 | S&F in repairs LED light fitting 1 x 9W/ 1 x 10W bulk head luminaires including LED light driver, holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 11 | Supply & replacement of energy saving LED street light 30 watt capacity high pressure die cast aluminium housing with seal toughened glass cover, light source should be multi LED SMD array with individual secondary lenses, colour temperature 6000K, 500(±) system efficiency should be minimum 110 lumen/ watt and minimum system lumen package of 6000 lumen as LM 79 operating voltage range 120-180 volts IP-66 THD less than 10%, surge protection minimum 5 KV with flash indication, driver should be potted/ CE certified/ R certified and driver efficiency 85% including bracket of size 1.5 metre made out of 40mm dia GI pipe & all other accesories and making connection complete all as specified and directed. |
| 12 | S&F in repairs ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals, complete all as specified and directed. |
| 13 | M&L in replacement for earthing complete with galvanised steel earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using earth lead wire 4.0mm connected by means of bolts ,nuts ,check nuts and washers of galvanized iron or steel and thimbles and other end of the earth wire connected to main switch board and protected by galvanized steel pipe 40mm bore (medium grade) connected to test point all as shown in electrical plate No. 3 of SSR - 2009 (Part-I) and including necessary excavation and earth work in any type of soil, 20mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber shall be constructed 500mm away from the edge of earth pit, pit cover of precast RCC (1:1½:3), type B-1, 80mm thick reinforced XPM of weight not less than 4 Kg/ Sqm. complete & connected to earthing test point all as specified or indicated including brazing/ testing on completion complete all as specified and directed. Notes:- (i) The unit rate includes galvanised Iron strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/ test point. (ii) Old earthing may have been burried down to a depth of exceeding 2.25m below ground level. No extra payment will be made if excavation is done beyond 2.25m depth to retrieve the old earthing. |
| 14 | M&L for Plain cement concrete (1:4:8), type D-2, using 40 mm graded mechanically crushed stone aggregates as in sub base ,foundations, filling and mass concrete, in and including demolition of unreinforced cement concrete in ground floors and paving n.exc 15cm thickness (below or above ground level) and removal of rubbish to a place as earmarked by civic body for this purpose outside of MoD land , complete all as specified and directed. Please Enable Macros to View BoQ information |