| 1 | Checking of unserviceable Window/split AC/Water Cooler/Desert Cooler U/S parts likewise relay,compressor,blade,motor, gas leakage,condensor coil,capacitor,Thermostate,Filter,PCB,Wiring etc all mechanical accessories in day to day and making it serviceable in all respect with all replacement of any major part but including minor repairs adhesive cable and other connected accessories by providing sufficient and skilled manpower, work shall also include to check & removal of leakage in window/splitAC /water cooler/ Deep freezer as and when directed. The scope also include complete checking of window/split/summer Appliances.Note:-(a) The rate quoted by the contractor for Each job is deemed to be included all minor repairs.(b) The contractor or his representative will take complaint from MES complaint Register through MES job card. (c)The contractor will made seprate items register with location and signature of user.(d) The contractor will maintain complete detail of JOB card and items involved with date and user signature. (e) The ladder and T&P as required will be provided by the contractor. (f) Risk Factor will be the contractor 's end. |
| 2 | M & L for servicing of window type AC of capacity 1.5/2 TR of any make including cleaning of filter on front side by removing dust, cleaning the condenser including fins, blower fan motor and checking and testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, replacing worn out rubber, bushes/rubber packing, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc and reassembling of complete AC including testing for smooth functioning Complete all as directed by Engineer-in-Charge. |
| 3 | S&F in repairs aluminium fan blade suitable for condenser of window type AC of any capacity complete all as specified and directed. |
| 4 | S&F in repairs PVC fan blower of cooling side of window type AC of any capacity complete all as specified and directed. |
| 5 | S & F in repairs wiring kit of window type AC complete with lugs, thimble and selector switch complete all as directed. |
| 6 | S&F for motor for window type AC of 1.5/2 TR capacity complete all as specified and directed. |
| 7 | Taking down electronic remote circuit board (PCB) of window type AC 1.5/2 ton removing for repair and re-fixing after repair including necessary dismantling, reconnecting, testing and putting into satisfactory working condition complete all as specified and directed. |
| 8 | M & L for servicing of split type AC of capacity 1.5/2 TR of any by opening the condenser unit fixed on roof top and cooling unit fixed inside the building, and cleaning the complete condenser unit and cooling unit including fins, blower fan motor and checking and testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, remore replacing worn out rubber, bushes/rubber packing, rectification of unusal noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc and reassembling of complete AC including testing for smooth functioning complete all as directed by Engineer-in-Charge.Note: Spare parts will paid in relevant item here in after:- |
| 9 | Supply only of air filter of size 10 micron Split type AC 1.5/2 TR complete all as specified and directed. |
| 10 | Supply only Blade for condensing fan motor Split type AC complete all as specified and directed. |
| 11 | Supply only running Capacitor 50 Mfd for 2 TR ac complete all as specified and directed. |
| 12 | Supply only running Capacitor 45 Mfd for 1.5 TR ac complete all as specified and directed. |
| 13 | Supply only condenser coil aluminium/copper of ac capacity 1.5 TR complete all as specified and directed. |
| 14 | Supply only condenser coil aluminium/copper of ac capacity 2 TR complete all as specified and directed. |
| 15 | Supply only suction valve brass type 5/8\\"of ac capacity 1.5 TR complete all as specified and directed. |
| 16 | Supply only suction valve brass type 5/8\\"of ac capacity 2 TR complete all as specified and directed. |
| 17 | Supply only coil sensor and room sensor for ac capacity of 1.5/2 TR complete all as specified and directed. |
| 18 | Supply only swing motor for air adjust of suitable size complete all as specified and directed. |
| 19 | Supply only relay for overload of suitable size for ac capacity 1.5/2 TR complete all as specified and directed. |
| 20 | Taking down electronic remote circuit board (PCB Indoor & Outdoor) of split type AC 1.5/2 ton for repairs and re-fixing after repair complete all as specified and directed |
| 21 | Supply only electronic remote circuit board (PCB) of window type AC 1.5/2 ton complete all as specified and directed |
| 22 | S & F in repairs PCB Senser unit with wire remote control of ductable split AC indoor unit of Capacity 1.5/2 TR for removing old PCB and refix with new PCB of same make & capacity (non inverter) and model in the same position complete all as directed by Engr in Charge. |
| 23 | S & F in repairs PCB Senser unit with wire remotre control of ductable split AC outdoor unit of Capacity 1.5/2 TR for removing old PCB and refix with new PCB of same make & capacity (inverter) and model in the same position complete all as directed by Engr in Charge. |
| 24 | S & F in repairs PCB Senser unit with wire remote control of ductable split AC indoor unit of Capacity 1.5/2 TR (PCB Inverter Type indoor units) for removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as directed by Engr in Charge. |
| 25 | S & F in repairs PCB Senser unit with wire remote control of ductable split AC outdoor unit of Capacity 1.5/2 TR (PCB Inverter Type outdoor units) for removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as directed by Engr in Charge. |
| 26 | M & L for gas charging in window type A/C unit 1.5/2 ton capacity using refrigerant gas as per standard practice after flushing, vacuuming incl detecting leakage, rectification of leakage, commissioning and testing upto sufficent pressure complete all as specified and directed |
| 27 | M & L for gas charging in split type type A/C unit 1.5/2 ton capacity using refrigerant gas as per standard practice after flushing, vacuuming incl detecting leakage, rectification of leakage, commissioning and testing upto sufficent pressure complete all as specified and directed |
| 28 | M&L for removing the cooling fan motor of capacity 1/30 or 1/35 HP from split type AC 1.5 TR,and S&F the same complete all as specified and directed. |
| 29 | M&L for removing the cooling fan motor of capacity 1/30 or 1/35 HP from split type AC 2 TR,and S&F the same complete all as specified and directed. |
| 30 | S&F of blower motor of capacity 1/30 or 1/20 HP split type AC 1.5/2TR complete all as specified and directed. |
| 31 | M & L for removing the unserviceable compressor sealed unit of any make from window/split type AC of capacity 1.5 TR after cutting copper tubing without any damage to existing parts, replacing compressor with reconditioned compressor of same make complete with erection of compressor on base with suitable capillary, filter etc. jointing of copper refrigerant pipe line, charging gas to required level, complete including cleaning of fins, leakage testing etc including testing for smooth functioning complete all as specified and directed. |
| 32 | M & L for removing the unserviceable compressor sealed unit of any make from window/split type AC of capacity 2 TR after cutting copper tubing without any damage to existing parts, replacing compressor with reconditioned compressor of same make complete with erection of compressor on base with suitable capillary, filter etc. jointing of copper refrigerant pipe line, charging gas to required level, complete including cleaning of fins, leakage testing etc including testing for smooth functioning complete all as specified and directed. |
| 33 | S & F in replacement of copper tubing 1/2\\" heavy duty complete all as specified and directed |
| 34 | S & F in replacement of copper tubing 1/4\\" heavy duty complete all as specified and directed |
| 35 | S & F in replacement of copper tubing 5/8\\" heavy duty complete all as specified and directed |
| 36 | S & F in replacement of PVC insulated & sheathed flexible 3 core copper cable of 4 Sqm complete all as specified and directed |
| 37 | S & F in replacement of PVC insulated & sheathed flexible 3 core copper cable of 6 Sqmm complete all as specified and directed |
| 38 | Supply only in replacement of new remote control for split/window type AC 1.5 ton/2 ton capacity with battery complete all as specified and directed |
| 39 | S&F for motor for window type AC of 1.5/2 TR capacity, complete all as specified and directed. |
| 40 | Installation /Re-installation only split tye Air conditioning electrically driven ,230/250V ,AC 50 Hz capacity 1.5/2.0 Ton to be fitted in wall with rowl plugs including making holes for inlet /outlet in the wall and making good existing surface including insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer all as specified |
| 41 | Supply and fixing in replacement of new auto swing motor for window/split type AC 1.5 TON/2 TON all as spcified. |
| 42 | Supply and fixing in replacement Fan Blower set for 1.5 Ton Split type AC (as per sample) complete all as spcified and directed. |
| 43 | M & L for removing the unserviciable compressor sealed unit of any make from water cooler 40/80 ltr after cutting copper tubing without any damage to existing part ,replacing compressor with reconditioned compressor of same make complete with erection of compressor on base with suitable capillary , filter etc, jointing of copper copper refrigerent pipe line charging gas to required level , complete including cleaning of fins, leakage testing etc including testing for smooth functioning. complete all as directed by engr in charge. |
| 44 | S&F in repaired Compressor for Deepfreezer capacity 300 ltr with relay and thermostat complete after dismantling and disconnecting of U/S compressor and topping up of refrigerant gas upto required level all as directed . |
| 45 | Supply & fix rubber gaskit of standard size for deep freezer with suitable screw and adhesives including removing u/s gaskits complete all as specified and directed. |
| 46 | S&F in repairs aluminium fan blade for water cooler complete all as specified and directed. |
| 47 | S&F in repairs thermostat suitable for water cooler of any capacity complete all as specified and directed. |
| 48 | S&F in repairs waste water tray, stainless steel with coupling suitable for water cooler of capacity 40/80 ltrs complete all as specified and directed. |
| 49 | S & F PVC drain out flexible pipe of 20mm dia 70 cms length with two mild steel clamps and necessary brass screws etc for water cooler of any size complete all as directed. |
| 50 | S & F in replacement push cock 15mm bore made out of brass chromium plated self closing vertical type complete all as directed. |
| 51 | Supply & fixing in repair copper cooling coil for deep freezer of capacity 310 ltr with suitable fittings after dismantling and disconnecting of U/S cooling coil including testing complete all as specified and directed. |
| 52 | Spply & fixing in repair of condensor motor of deep freezer of capacity 400 ltr with suitable fittings after dismantling and disconnecting of U/S cooling coil including testing complete all as specified and directed. |
| 53 | Supply & fix in repair 3 pin plug top of 15 amp including 3 mtr including PVC sheathed round flexible wire pvc 3 core 2.5sqmm of 3 mtr length for deep freezer complete all as specified and directed. |
| 54 | M & L for repair for cutting and removing unserviceable freezer unit of refrigerator capacity 165/170/175 ltrs of any make, and supply and fix new freezer unit with door and chill tray including jointing, brazing, recharging of refrigerator gas and testing for smooth functioning complete all as specified and directed. |
| 55 | S & F in repairs of bulb for pin/screw type 230 Volts suitable for refrigerator 175 to 310 ltrs capacity complete all as specified and directed. |
| 56 | Supply and topping up of Refrigerant gas R 134/404 in refrigerators/Deep freezers at different site as required including brazing and removal of leakage in equipment complete all as specified and directed. |
| 57 | Supply & fixing in repair copper cooling coil for refrigerator of capacity 190 ltr complete all as specified and directed. |
| 58 | Supply & fix in repair 3 pin tlug top of 5 amp including 3 mtr including PVC sheathed round flexible wire pvc 3 core 40/0.0076 of 3 mtr length for refrigerator complete all as specified and directed. |
| 59 | M&L for cleaning after taking down complete body including fitting and fixture of desert cooler of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparationand cleaning of surface for painting and applying two coats of synthetic enamel spray paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank, and rewriting of MES No. etc. complete all as specified and directed. |
| 60 | S&F in repairs PVC flexible pipe 16mm outer dia complete with PVC elbow etc complete all as specified and directed. |
| 61 | S&F in repairs selector switches three way 230 Volts single phase of standard quality fixed in desert coolers complete all as specified and directed. |
| 62 | S&F in repairs wood wool pad (set of three), minimum weight 0.8 Kg, fixed in side panels of desert coolers complete all as directed. |
| 63 | S&F in repairs switch piano type 250 Volts, single pole one ways 5 amps, fixed in desert coolers. |
| 64 | S&F repairs PVC insulated and PVC sheathed round flexible three core copper conductor cable of size 40/0.0076 Sqmm including necessary connection fixed in desert coolers. |
| 65 | S&F in repairs capacitor 4 Mfd for fan motors of desert coolers. |
| 66 | S& F in repairs Submersible pump 230 volts suitable for desert cooler of capacity 4000/5000 including necessary wiring complete all as directed.Make Crompton/ Khaitan |
| 67 | S & F in repairs side shutter (set of three) made out from 24 guagethick galvanized iron sheet suitable for 4000/5000 cum/hrs capacity desert coolers complete all as directed. |
| 68 | S&F in repairs float valve high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball, screwed for 15mm bore iron pipe, weight not less than 142 gm/each. Complete all as directed. |
| 69 | S & F in repairs Aluminium fan blade for fan motor of desert cooler 20 inch sweep. |
| 70 | S & F in repairs PVC, 3 way distributor suitable for 15 mm pipe with nut/screws all as directed. |
| 71 | S & F desert cooler fan motor 3 speed copper winding ISI mark including suitable leg set of three including nut bolt washer all as directed. |
| 72 | M & L for sub main wiring along with earth wire drown through PVC case & caping for split type A/Cs with FRLS PVC insulated, unsheathed multi stranded copper single core cable of size 2 x 2.5 sqmm and 1 x 2.5 sqmm for earth wire including taking down old wiring all as directed. |
| 73 | M & L for sub main wiring along with earth wire drown through PVC case & caping for split type A/Cs with FRLS PVC insulated, unsheathed multi stranded copper single core cable of size 2 x 4.0 sqmm and 1 x 4.0 sqmm for earth wire including taking down old wiring all as directed. |
| 74 | Supply & fixing in repairs single pole and neutral enclosure with a two pin and socket complete with one single pole MCB 240 volts, 20 Amps all as specified and directed. |
| 75 | Supply & fix in repair wall mount stand powder coated for split ac outdoor unit shall be fixed on wall with standard bracket or fixed on roof /floor with proper MS stand with grouting bolt/nut arrangement fixing copper tubes on wall with suitable size of pvc clits/nails as specified and directed. |
| 76 | Supply & fix foam type insulating flexible pipe fitted on suction/discharge copper tubes of suitable sizes including removing old insulation. Please Enable Macros to View BoQ information |