| 1 | Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed by Engineer- in-charge . |
| 2 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed by Engineer- in-charge . |
| 3 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed by Engineer- in-charge . |
| 4 | M & L for Point wiring for One light point controlled by one, one way switch 5 Amps using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in Stone wall/wall/ceiling etc, heavy duty ISI marked, with mild steel sunken boxes 1.6 mm thick, 60 mm deep with earth dolly duly, covered with hylem sheet cover 3 mm thick, ISI marked suitable for fixing of switches, fan regulators and sockets including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer- in-charge . |
| 5 | Description all as per item No 4 above but for One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator complete all as specified and directed by Engineer- in-charge . |
| 6 | Description all as per item No 4 above but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and directed by Engineer- in-charge . |
| 7 | Description all as per item No 4 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. complete all as specified and directed by Engineer- in-charge . |
| 8 | Description all as per item No 4 here in before but using 2.5 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLSH cable of multistranded PVC insulated unsheathed as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 9 | S & F for modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and directed by Engineer- in-charge . |
| 10 | S & F for modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified and directed by Engineer- in-charge . |
| 11 | S & F for modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed by Engineer- in-charge . |
| 12 | S & F for modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed by Engineer- in-charge . |
| 13 | S & F for modular step type fan regulator 100/120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and directed by Engineer- in-charge . |
| 14 | S & F for for Lamp holder, PVC body of brass suitable for batten fitting complete all as specified and directed by Engineer- in-charge . |
| 15 | S & F for ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and directed by Engineer- in-charge . |
| 16 | M&L for sub main wiring with two runs of 4.00 Sqmm single core FRLS PVC unsheathed and insulated 1100 Volt grade/Multi stranded copper conductor drawn through PVC conduit & accessories fixed an surface of walls, ceiling floors etc including one run of PVC insulated and unsheathed cable of copper conductor of 4.00 Sqmm single core as earth continuity wire complete all as specified and directed by Engineer- in-charge .. Note :- Two runs of single core PVC insulated unshethed cables and one run of earth continuity conductor incl conduit will be messured and paid as one unit. |
| 17 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and directed by Engineer- in-charge Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 18 | S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with nstallation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed by Engineer- in-charge . |
| 19 | S & F for LED tube light fitting 2 feet x 10 watts with high out put diffuser, anodized extruded aluminium, housingdecorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed by Engineer- in-charge . |
| 20 | S & F for LED tube light fitting 2 feet x 5 watts with high out put diffuser,anodized extruded aluminium, housingdecorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed by Engineer- in-charge . |
| 21 | M & L for rewinding of ceiling fan of any size with supper enameled copper wire of existing gauge including varnishing and drying complete reassembling & testing complete of size 1200 mm sweep complete all as specified and directed by Engineer- in-charge . |
| 22 | Supply only electric blower fan Motor of capacity 1/5 HP, 950 RPM for 1.5 ton AC complete all as specified and directed by Engineer- in-charge . |
| 23 | Servicing only Split type air conditioner in citu (Split type air conditioner comprises wiith out door and indoor unit complete) of capacity 1.5/ 2.0 TR of any make and any type by replacing unserviceable parts from the machine including charging of Refrigerant gas after vacuuming and leak testing. Brazing the suction/ discharge tubes where required and cleaning of cooling coil and condenser coil, oiling, greasing of blower motor, checking of electrical circuit and replacement of defective electric blower fan motor,over load protector,relay, capacitor etc to achive proper cooling effect and also checking of electronic circuit of machine and repair where necessory by replacing electronic parts and changing of wirings with proper size PVC insulated wires as directed and testing commissioning complete all as specified and directed by Engineer- in-charge ..Note:-The spare parts shall be measured and paid seperatly as supply only and labour for fixingof spare part included in these item only. |
| 24 | Supply only starting capacitor 100/120 MFD complete and complete all as specified and directed by Engineer- in-charge . |
| 25 | Supply only outdoor unit fan motor 1/20 HP 230 Volt Split AC of capacity 1.5 ton complete all as specified and directed by Engineer- in-charge . |
| 26 | Removing the old unserviceable sealed compressor unit from split AC of any make, capacity 1.5 TR and supply and fixing new hermetically sealed compressor of same make for split AC of capacity 1.5 TR with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed by Engineer- in-charge . |
| 27 | Removing the old unserviceable sealed compressor unit from split AC of any make, capacity 2.0 ton and supply and fixing new hermetically sealed compressor of same make for split AC of capacity 2.0 TR with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed by Engineer- in-charge . |
| 28 | Supply and Charging of non CFC Refrigerant Gas R -134 to water cooler, refrigerator and deep freezer of any type, make and capacity complete all as specified and directed by Engineer- in-charge . |
| 29 | Attending the complaints of non functional and Preventive maintenance of storage type electric water heater (Geyser) of capacity 25/50 ltrs comprising of the following tasks at different locations of any make, complete all as specified and as directed. (a) Inspection of geyser after opening bottom cover plate. (b) Examine water tightness of storage tank. (c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts.(d) Replace washers and glands of defective taps to ensure water tightness smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any.(f) Check and correct earth continuity of electrical items. (g) Check and correct temperature setting of thermostats and test its functioning. (h) Checking and adjustments of pressure reducing valves. (i) Checking of dead weight type high pressure release valve (PRV) by removing dead weight protection cleaning the seat and ensuring that the waste hole is not blocked / chocked. (j) Testing of Geysers after repairs/maintenance in all respect for proper functioning complete all as specified and as directed. Note:- Items if any found defective during inspection shall be measured and paid seperatly as supply only.Labour for fixing shall be included in this item only. |
| 30 | Supply only heating element as per sample including rubber washers (ISI marked) of any type suitable to existing gyser of capacity 1500 watts.complete all as specified and directed by Engineer- in-charge . |
| 31 | Supply only heating element as per sample including rubber washers (ISI marked) of any type suitable to existing gyser of capacity 2000 watts complete all as specified and directed by Engineer- in-charge . |
| 32 | Supply only thermostat ISI marked suitable for the Geysers 25 ltrs/ 50 ltrs capacity, 20 Amps, 240 Volts AC, adjustable type, 210 mm long or nearest size as per sample complete all as specified and directed by Engineer- in-charge . |
| 33 | Supply only thermostat ISI marked suitable for the Geysers 25 ltrs. to 50 ltrs capacity,20 Amps, 240 Volts AC, fixed type,300 mm long or nearest size, Set at 90+/-6 degreeC as per sample complete all as specified and directed by Engineer- in-charge . |
| 34 | Supply only CP connections pipe with brass hexagonal adapters both side suitable for 15mm dia pipe 60 cm long for cold water as per requirement complete all as specified and directed by Engineer- in-charge . |
| 35 | Supply only CP connections pipe with brass hexagonal adapters both side suitable for 15mm dia pipe 60 cm long for hot water as per requirement complete all as specified and directed by Engineer- in-charge .. |
| 36 | S & F for modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and directed by Engineer- in-charge . |
| 37 | S & F for modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified and directed by Engineer- in-charge . |
| 38 | S & F for modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed by Engineer- in-charge . |
| 39 | S & F for modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed by Engineer- in-charge . |
| 40 | S & F for modular step type fan regulator 100/120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and directed by Engineer- in-charge . |
| 41 | S & F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed by Engineer- in-charge . |
| 42 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed by Engineer- in-charge . |
| 43 | S & F for MCB Tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and directed by Engineer- in-charge . |
| 44 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and directed by Engineer- in-charge . |
| 45 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and directed by Engineer- in-charge . |
| 46 | S & F for metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and directed by Engineer- in-charge . |
| 47 | Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 1.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed by Engineer- in-charge . |
| 48 | Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 2.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed by Engineer- in-charge . |
| 49 | Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 4 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed by Engineer- in-charge . |
| 50 | Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 6 Sqmm from sub main wiring including removal old existing unserviceable one complete all as specified and directed by Engineer- in-charge . |
| 51 | Supply and fix oscillating Pedestal fan with tilt mechanism and AC single phase 230/240 volt of size 400mm sweeps with 1350 RPM, copper winding,( Bajaj, Orient, Atomberg, Havells) |
| 52 | Supply and fix wall mounting fan with tilt mechanism and AC single phase 230/240 volt of size 400mm sweeps with 1350 RPM, copper winding, Three speeds controle, Telescopic arrangement with 2 year warranty.( Bajaj, Orient, Atomberg, Havells) |
| 53 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as specified and directed by Engineer- in-charge . |
| 54 | M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. Please Enable Macros to View BoQ information |