| 1 | Supplying and erecting approved make Conical Pole (Medium Duty ) Made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/2633/4759, with required base plate and integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for cable terminations as erected on suitable foundation (included) with necessary GI nut-bolts/J-Bolts. as per details given by manufacturer considering site requirement. The length of poles are as below.(E) 7 Mtr. Long 70 mm Top X 175 mm bottom dia, 3 mm thickness | Supplying and erecting approved make Conical Pole (Medium Duty ) Made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/2633/4759, with required base plate and integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for cable terminations as erected on suitable foundation (included) with necessary GI nut-bolts/J-Bolts. as per details given by manufacturer considering site requirement. The length of poles are as below.(E) 7 Mtr. Long 70 mm Top X 175 mm bottom dia, 3 mm thickness |
| 2 | Supplying and erecting approved make Conical Pole (Medium Duty ) Made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/2633/4759, with required base plate and integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for cable terminations as erected on suitable foundation (included) with necessary GI nut-bolts/J-Bolts. as per details given by manufacturer considering site requirement. The length of poles are as below.((D) 6 Mtr. Long 70 mm Top X 160 mm bottom dia, 3 mm thickness | Supplying and erecting approved make Conical Pole (Medium Duty ) Made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/2633/4759, with required base plate and integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for cable terminations as erected on suitable foundation (included) with necessary GI nut-bolts/J-Bolts. as per details given by manufacturer considering site requirement. The length of poles are as below.((D) 6 Mtr. Long 70 mm Top X 160 mm bottom dia, 3 mm thickness |
| 3 | Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(D) 2 to 4 core 16 Sq. mm | Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(D) 2 to 4 core 16 Sq. mm |
| 4 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (C) 16/25 Sq.mm. | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (C) 16/25 Sq.mm. |
| 5 | Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity (A) 6 to 32 Amp. CAT III | Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity (A) 6 to 32 Amp. CAT III |
| 6 | Providing and erecting Street Light pole bracket comprising main B Class MS pipe of 4.2 cm/require outside dia. complete with suitable B Class M.S. sleeve tubing of approx. 45cms.length and suitable for 76.5 mm /80mm / required size of pole top having sufficient fasteners for fixing the brackets and having spread of 1.5.mtr. length with 110 deg.with vertical plane & suitable welded stays, reducer and with check nuts complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with following nos of arms.[A] Single Arm Bracket 1.5 Mtr | Providing and erecting Street Light pole bracket comprising main B Class MS pipe of 4.2 cm/require outside dia. complete with suitable B Class M.S. sleeve tubing of approx. 45cms.length and suitable for 76.5 mm /80mm / required size of pole top having sufficient fasteners for fixing the brackets and having spread of 1.5.mtr. length with 110 deg.with vertical plane & suitable welded stays, reducer and with check nuts complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with following nos of arms.[A] Single Arm Bracket 1.5 Mtr |
| 7 | Providing and erecting Street Light pole bracket comprising main B Class MS pipe of 4.2 cm/require outside dia. complete with suitable B Class M.S. sleeve tubing of approx. 45cms.length and suitable for 76.5 mm /80mm / required size of pole top having sufficient fasteners for fixing the brackets and having spread of 1.5.mtr. length with 110 deg.with vertical plane & suitable welded stays, reducer and with check nuts complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with following nos of arms.[B] Double Arm Bracket 1.5 Mtr | Providing and erecting Street Light pole bracket comprising main B Class MS pipe of 4.2 cm/require outside dia. complete with suitable B Class M.S. sleeve tubing of approx. 45cms.length and suitable for 76.5 mm /80mm / required size of pole top having sufficient fasteners for fixing the brackets and having spread of 1.5.mtr. length with 110 deg.with vertical plane & suitable welded stays, reducer and with check nuts complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with following nos of arms.[B] Double Arm Bracket 1.5 Mtr |
| 8 | Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) (v)above 160 watts CAT III | Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) (v)above 160 watts CAT III |
| 9 | Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) (iv)above 120 watts CAT III | Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) (iv)above 120 watts CAT III |
| 10 | Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) (II)above 60 watts CAT III | Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) (II)above 60 watts CAT III |
| 11 | Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv grade ISI marked copper wires of following size to be erected as directed.(h) 2.50 Sq.mm 3 core round PVC sheathed | Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv grade ISI marked copper wires of following size to be erected as directed.(h) 2.50 Sq.mm 3 core round PVC sheathed |
| 12 | Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables(A) 4 core 16 Sq. mm | Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables(A) 4 core 16 Sq. mm |
| 13 | Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground / road surface for enclosing cable (A)50 mm outer dia | Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground / road surface for enclosing cable (A)50 mm outer dia |
| 14 | Providing & laying approved make ISI marked HDPE 6Kg / cm2 (Class-3) as per IS:4984:1995 PE-80 to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr.(E) 90 mm inner Dia | Providing & laying approved make ISI marked HDPE 6Kg / cm2 (Class-3) as per IS:4984:1995 PE-80 to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr.(E) 90 mm inner Dia |
| 15 | Smart 4G Timer, Supply of IoT based 4G Smart Streetlight Control & Monitoring System having a Smart Panel comprising of 3 Phase IoT Streetlight Smart 4G Timer with 16x2 LCD to display RSSI, relay status, RTC time & diagnostics., Controller works on 3-phase & also on any available 1-Phase., Controller with 8-hour battery backup during external power failure. External power failure alert immediately to cloud., 110-630 V AC @ 50-60 Hz – 3 phase operating range., Standby power consumption <3W., Smart 4G Timer with RS232 port for DLMS Energy meter., Smart 4G Timer must be compatible with any make / brand of DLMS (RS232) Energy Meter., DI: 4 Nos. (3 Contactor / Latch detection, 1 for Door Sensor.)., DO: 3 Relays for Independent control each phase (R, Y, B) with 1 extra spare relay., Smart 4G Timer with dual SIM functionality for connectivity backup., 4G M2M SIM 3-Year communication included., Local configuration via WiFi / BLE for maintenance or during force majeure., GPS chip inbuilt of Smart 4G Timer for auto location tracking & astronomic schedule location., 50 programmable schedules., Astronomic scheduling with monthly offsets., Smart 4G Timer has inbuilt timer stores schedules locally & also stores schedule execution logs locally, syncs to cloud whenever connected to cloud., Auto-scheduler overrides manual operations., Monitoring & alerts for MCB trips., Over/under voltage, current, overload, power factor & short circuit protections with alerts via Dashboard, App, SMS, WhatsApp & Email., Contactor / Latch chattering protection & alerts., Smart 4G Timer with neutral failure protection and alert., Bulit-in Watchdog for anti-jamming., Smart 4G Timer must send Regular \\"heartbeat\\" on software for CCMS status., It stores & syncs connectivity logs for configuration of network connections & analytics., PANEL & SWITCHGEAR, The panel includes a Class 1 DLMS energy meter NABL approved with 1-2 months of stored data of daily, hourly, monthly, load survey, instantaneous, events, tamper data & with power events stored in meter memory for audit purpose., Must monitor V, I, KWH, KVA, PF, KVAH, etc., Panel made with 2 mm CRCA sheet with ground mountable stand complete with gland plate, waterproof glands, earthing bolt., IP55, weatherproof panel with RAL7035 powder-coated., Smart 4G Timer must be fitted on removable terminal sockets for easy maintenance., Switchgear includes 3 Nos. 3 pole Contactor / Latch having minimum 50 A Load carrying capacity per phase, all other switchgear & wires: 40 A load carrying capacity., 1 Nos. 4P MCB 10 kA for Incomer & 6 Nos. 1P MCBs 10 kA for Outgoing., Phase-Wise Bypass MCBs required., 4P RCCB 100 mA., door sensor. Also, provide lock & key facility., Panel mount outdoor antenna for GSM, GPS., Canopy design for draining down water., CCMS SMART SOFTWARE, OAuth 2.0 APIs for sending data to Government clouds/software, etc., CCMS Web dashboard with secure password & OTP login., Hosted on trusted cloud, data security, antivirus & attack protection., HTTPS., AES256-bit encryption., Vulnerability Assessment and Penetration Testing (VAPT) certificate for CCMS Software., Streetlight management software for load status, live analytics & reports., Energy meter data tables (kW, kWh, PF, I, V, etc.) available., Utility monthly bill reconciliation & Class 1 accuracy reports for billing, energy monitoring & auditing for streetlight load., Fault detection., Light fault 99% analysis on dashboard using energy monitoring., WhatsApp integration., Hierarchy-wise reporting & alerts., GIS mapping of live connected streetlight control panels, poles & streetlights., MQTT protocol., Smartphone app with local configuration & navigation., Monitoring & reporting of lighting parameters., Facility for media attachments for site photos/videos/work permits/checklists, etc. per Feeder Panel for remote verification., Asset management module for streetlight infrastructure data., Complaint/service task management with history & escalation must be available., Android & iOS App for dashboard analytics, graphs, energy data, alerts., 3 Years CCMS Web Software & Cloud Server Hosting subscription included., Customizable, user-friendly dashboard., | Smart 4G Timer, Supply of IoT based 4G Smart Streetlight Control & Monitoring System having a Smart Panel comprising of 3 Phase IoT Streetlight Smart 4G Timer with 16x2 LCD to display RSSI, relay status, RTC time & diagnostics., Controller works on 3-phase & also on any available 1-Phase., Controller with 8-hour battery backup during external power failure. External power failure alert immediately to cloud., 110-630 V AC @ 50-60 Hz – 3 phase operating range., Standby power consumption <3W., Smart 4G Timer with RS232 port for DLMS Energy meter., Smart 4G Timer must be compatible with any make / brand of DLMS (RS232) Energy Meter., DI: 4 Nos. (3 Contactor / Latch detection, 1 for Door Sensor.)., DO: 3 Relays for Independent control each phase (R, Y, B) with 1 extra spare relay., Smart 4G Timer with dual SIM functionality for connectivity backup., 4G M2M SIM 3-Year communication included., Local configuration via WiFi / BLE for maintenance or during force majeure., GPS chip inbuilt of Smart 4G Timer for auto location tracking & astronomic schedule location., 50 programmable schedules., Astronomic scheduling with monthly offsets., Smart 4G Timer has inbuilt timer stores schedules locally & also stores schedule execution logs locally, syncs to cloud whenever connected to cloud., Auto-scheduler overrides manual operations., Monitoring & alerts for MCB trips., Over/under voltage, current, overload, power factor & short circuit protections with alerts via Dashboard, App, SMS, WhatsApp & Email., Contactor / Latch chattering protection & alerts., Smart 4G Timer with neutral failure protection and alert., Bulit-in Watchdog for anti-jamming., Smart 4G Timer must send Regular \\"heartbeat\\" on software for CCMS status., It stores & syncs connectivity logs for configuration of network connections & analytics., PANEL & SWITCHGEAR, The panel includes a Class 1 DLMS energy meter NABL approved with 1-2 months of stored data of daily, hourly, monthly, load survey, instantaneous, events, tamper data & with power events stored in meter memory for audit purpose., Must monitor V, I, KWH, KVA, PF, KVAH, etc., Panel made with 2 mm CRCA sheet with ground mountable stand complete with gland plate, waterproof glands, earthing bolt., IP55, weatherproof panel with RAL7035 powder-coated., Smart 4G Timer must be fitted on removable terminal sockets for easy maintenance., Switchgear includes 3 Nos. 3 pole Contactor / Latch having minimum 50 A Load carrying capacity per phase, all other switchgear & wires: 40 A load carrying capacity., 1 Nos. 4P MCB 10 kA for Incomer & 6 Nos. 1P MCBs 10 kA for Outgoing., Phase-Wise Bypass MCBs required., 4P RCCB 100 mA., door sensor. Also, provide lock & key facility., Panel mount outdoor antenna for GSM, GPS., Canopy design for draining down water., CCMS SMART SOFTWARE, OAuth 2.0 APIs for sending data to Government clouds/software, etc., CCMS Web dashboard with secure password & OTP login., Hosted on trusted cloud, data security, antivirus & attack protection., HTTPS., AES256-bit encryption., Vulnerability Assessment and Penetration Testing (VAPT) certificate for CCMS Software., Streetlight management software for load status, live analytics & reports., Energy meter data tables (kW, kWh, PF, I, V, etc.) available., Utility monthly bill reconciliation & Class 1 accuracy reports for billing, energy monitoring & auditing for streetlight load., Fault detection., Light fault 99% analysis on dashboard using energy monitoring., WhatsApp integration., Hierarchy-wise reporting & alerts., GIS mapping of live connected streetlight control panels, poles & streetlights., MQTT protocol., Smartphone app with local configuration & navigation., Monitoring & reporting of lighting parameters., Facility for media attachments for site photos/videos/work permits/checklists, etc. per Feeder Panel for remote verification., Asset management module for streetlight infrastructure data., Complaint/service task management with history & escalation must be available., Android & iOS App for dashboard analytics, graphs, energy data, alerts., 3 Years CCMS Web Software & Cloud Server Hosting subscription included., Customizable, user-friendly dashboard., |
| 16 | Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only Cat III | Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only Cat III |
| 17 | Supplying & erecting funnel type earthing having earth plate of following size burred in specifically prepared earth pit 3 mtr. below ground with 40 kg. charcoal and salt with alternate layers of charcoal & salt, 20mm.dia. G.I. pipe with Funnel with a wire mesh for watering & bricks masonry block, C.I. Cover complete as per para 7.3 of IS 3043 with necessary length of double Galvanised Iron / copper earth wire No 6 SWG bolted with lug to the plate and covered in 12 mm dia. G.I. pipe 2.5 mtr long complete connected to the nearest switch gear with end socket as per direction & duly tested by earth tester confirming to IS (As per drawing) with following specification (C) with 60 x 60x 0.315 cms. Copper earth Plate | Supplying & erecting funnel type earthing having earth plate of following size burred in specifically prepared earth pit 3 mtr. below ground with 40 kg. charcoal and salt with alternate layers of charcoal & salt, 20mm.dia. G.I. pipe with Funnel with a wire mesh for watering & bricks masonry block, C.I. Cover complete as per para 7.3 of IS 3043 with necessary length of double Galvanised Iron / copper earth wire No 6 SWG bolted with lug to the plate and covered in 12 mm dia. G.I. pipe 2.5 mtr long complete connected to the nearest switch gear with end socket as per direction & duly tested by earth tester confirming to IS (As per drawing) with following specification (C) with 60 x 60x 0.315 cms. Copper earth Plate |
| 18 | Drilling the road without breaking the road surface (Asphalt) for laying of cable for feeding power supply by making up to following size of holes at both ends complete..(B) Up to 150 mm bore dia | Drilling the road without breaking the road surface (Asphalt) for laying of cable for feeding power supply by making up to following size of holes at both ends complete..(B) Up to 150 mm bore dia |
| 19 | Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating the fault all over the run and back filling the same and making the surface as normal ground. | Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating the fault all over the run and back filling the same and making the surface as normal ground. |
| 20 | Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or required depth for laying any size of cable or locating the fault all over the run and back filling the same and making the surface as normal ground. | Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or required depth for laying any size of cable or locating the fault all over the run and back filling the same and making the surface as normal ground. |
| 21 | Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level.Dismantling the existing any type of fittings above 6 mt height pole from pole with bracket complete. | Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level.Dismantling the existing any type of fittings above 6 mt height pole from pole with bracket complete. |
| 22 | Providing & erecting MS Cage with requried work of concreting and foundation of MS cage as directed by Engineer-in-Charge for the Street light pole protection. The pole should be made from MS and should have coat of PU base primer and PU base paint. MS cage should be made of Angle, Flate and square hollow pipe. Angle size should be 240 mm x 40mm and thickness 5 mm. | Providing & erecting MS Cage with requried work of concreting and foundation of MS cage as directed by Engineer-in-Charge for the Street light pole protection. The pole should be made from MS and should have coat of PU base primer and PU base paint. MS cage should be made of Angle, Flate and square hollow pipe. Angle size should be 240 mm x 40mm and thickness 5 mm. |
| 23 | Painting the number and words for inventory Identification on erected fittings / equipment's or Such accessories as may required with good quality of enamelled paint as directed by engineer in charge(i) up to 20 characters, up to 50 mm | Painting the number and words for inventory Identification on erected fittings / equipment's or Such accessories as may required with good quality of enamelled paint as directed by engineer in charge(i) up to 20 characters, up to 50 mm |
| 24 | Repairing of existing indoor LED light fixture(flood light/street light/bollard lights/decorative wall lights/landscape light etc as per sample )by suitable driver 4 kv,IP65 according to LED PCB as per requirement of following rating wattage capacity .(H) 120-160 watt capacity | Repairing of existing indoor LED light fixture(flood light/street light/bollard lights/decorative wall lights/landscape light etc as per sample )by suitable driver 4 kv,IP65 according to LED PCB as per requirement of following rating wattage capacity .(H) 120-160 watt capacity |