| 1 | Shifting and heightening of HT/LT lines and distribution transformer of N.H 306 due to heightening/widening of road by NHIDCL.(refer Annexure1)Itemwise price should be filled in strictly as per the detailed Bill of Quantities at respective referred Annexure. |
| 2 | Distmantling of HT/LT lines and distribution Transformer of N.H 306 due to heightening/widening of road . (Location-Ranghirkhari point to N.H Culvert near Rahimer Dukan).(refer Annexure2)Itemwise price should be filled in strictly as per the detailed Bill of Quantities at respective referred Annexure. |
| 3 | GI Steel Tubular Pole SP-76 (14.50) |
| 4 | PSC Pole 9.75m |
| 5 | ACSR \\" WOLF\\" Conductor |
| 6 | ACSR \\" RACCON\\" Conductor |
| 7 | ACSR \\" RABBIT\\" Conductor |
| 8 | Polymeric Pin Insulator (FRP 34mm) |
| 9 | GI Channel Cross Arm (100x50x6x3200mm) |
| 10 | GI Channel Cross Arm (100x50x6x2200mm) |
| 11 | GI 11KV T Cross Arm wirh angle size 50x50x6mm |
| 12 | Disc Insulator (Polymeric) 90kN (T&C Type) |
| 13 | H/W fitting for Disc Insulator T&C 90kN tension type |
| 14 | GI Angle (50x50x6)mm |
| 15 | Hot Dip GI Wire Stay Wire 7/10 SWG (For HT) |
| 16 | HT Stay Set |
| 17 | Guy Insulator (Porcelain) |
| 18 | GI earthing Pipe 50mm dia 3m length 3.15 mm thickness with perforated holes of 15mm dia at 30 cm interval along length of the pipe |
| 19 | Hot Dip GI Wire 6 SWG |
| 20 | 33KV Danger Plate |
| 21 | 11KV Danger Plate |
| 22 | GI Nuts & Bolts with Washer(Assorted) |
| 23 | PG Clamp for ACSR Wolf |
| 24 | Pole Clamp of GI Flat 50x6mm |
| 25 | LT Pin Insulator (Porcelain) |
| 26 | LT GI Pin |
| 27 | Shackle Insulator Porcelain |
| 28 | GI LT Angle Cross Arm (40x40x6x500)mm |
| 29 | LT GI Shackle Strap with Bolts |
| 30 | Pin Insulator (Polymer) 5KN (FRP 24mm) |
| 31 | 11KV GOAB Switch 400Amp |
| 32 | 11KV DO Fuse Set 200A Assembly |
| 33 | GI Strip 25x3mm for DTR earthing |
| 34 | GI strip 50x6mm for DTR Neutal earthing |
| 35 | 11KV 5KA Lightning Arrestor (Line Type, Distribution Class) |
| 36 | 11/0.4KV 63KVA DTR Aluminium WoundBIS Level - 2 |
| 37 | 11/0.4KV 100KVA DTR Aluminium Wound - BIS Level - 2 |
| 38 | 11/0.4KV 250KVA DTR Copper wound - BIS Level - 2 |
| 39 | 11/0.4KV 500KVA DTR Copper Wound - BIS Level - 2 |
| 40 | Aluminium Lugs-240Sq mm |
| 41 | Aluminium Lugs-300Sq mm |
| 42 | Aluminium Lugs-185Sq mm |
| 43 | 1C x 240 sq.mm. |
| 44 | 1C x 300 sq.mm. |
| 45 | 1C x 185 sq.mm. |
| 46 | Grouting & mufflering of steel tubular pole of type SP-66 and SP-76 as per specification and drawing with minimum planting depth of 2.15 m (using PCC) |
| 47 | Grouting & mufflering of prestressed concrete pole of length 9.75 m as per specification and drawing with minimum planting depth of 1.8 m (using PCC) |
| 48 | DTR Fencing as per REC standard specification complete with material & labour |
| 49 | Transformer pad for station transformer complete as per specification |
| 50 | GI Steel Tubular Pole SP-60 (12.00) |
| 51 | PSC Pole 8.5m |
| 52 | PSC Pole 7.5m |
| 53 | ACSR \\" WOLF\\" Conductor |
| 54 | ACSR \\" RACCON\\" Conductor |
| 55 | ACSR \\" RABBIT\\" Conductor |
| 56 | Polymeric Pin Insulator (FRP 34mm) |
| 57 | GI Channel Cross Arm (100x50x6x3200mm) |
| 58 | GI Channel Cross Arm (100x50x6x2200mm) |
| 59 | GI 11KV T Cross Arm wirh angle size 50x50x6mm |
| 60 | Disc Insulator (Polymeric) 90kN (T&C Type) |
| 61 | H/W fitting for Disc Insulator T&C 90kN tension type |
| 62 | GI Angle (50x50x6)mm |
| 63 | Hot Dip GI Wire 6 SWG |
| 64 | GI Nuts & Bolts with Washer(Assorted) |
| 65 | PG Clamp for ACSR Wolf |
| 66 | Pole Clamp of GI Flat 50x6mm |
| 67 | LT Pin Insulator (Porcelain) |
| 68 | LT GI Pin |
| 69 | Shackle Insulator Porcelain |
| 70 | GI LT Angle Cross Arm (40x40x6x500)mm |
| 71 | LT GI Shackle Strap with Bolts |
| 72 | Disc Insulator (Polymer) 70kN (B&S Type) |
| 73 | H/W fitting for Disc Insulator B&S 70kN tension type |
| 74 | Pin Insulator (Polymer) 5KN (FRP 24mm) |
| 75 | 11KV GOAB Switch 400Amp |
| 76 | 11KV DO Fuse Set 200A Assembly |
| 77 | 11KV 5KA Lightning Arrestor (Line Type, Distribution Class) |
| 78 | 11/0.4KV 63KVA DTR Aluminium WoundBIS Level - 2 |
| 79 | 11/0.4KV 100KVA DTR Aluminium Wound - BIS Level - 2 |
| 80 | 11/0.4KV 250KVA DTR Copper wound - BIS Level - 2 |
| 81 | 11/0.4KV 500KVA DTR Copper Wound - BIS Level - 2 |
| 82 | DTR Cubical for 100KVA DTRS (comprising of requisite one Micrprossessor based MCCB for incomming, three TM release MCCB for outgoing, Static TVM, CT, Vmeter,Ammeter etc.) |
| 83 | DTR Cubical for 250KVA DTRs (comprising of requisite one Micrprossessor based MCCB for incomming, three TM release MCCB for outgoing, Static TVM, CT, Vmeter,Ammeter etc.) |
| 84 | DTR Cubical for 63KVA DTRs (comprising of requisite one Micrprossessor based MCCB for incomming, three TM release MCCB for outgoing, Static TVM, CT, Vmeter,Ammeter etc.) Please Enable Macros to View BoQ information |