| 1 | Work For Attending 33 KV/11KV/LT underground cable/Outdoor/indoor cable faults(Emergency Nature) under Urban Electricity Distribution Division - Sarnath, Varanasi in UEDSD-III, Panchkoshi, Varanasi. |
| 2 | 33KV Cable |
| 3 | Repairing of 33 KV Underground cable Fault with the help of Straight Through |
| 4 | 33 KV underground cable fault- Locating the fault with the help of fault location machine & Driver, Providing skilled cable Jointer & labour, digging trench with the help of road cutter/digging machine/tractor/manual etc. Size of trench 4 m. length x 1.5 m.width and upto depth of cable exposing the fault cable, preparing the cable , filling cable jointing kit, High pressure testing of cable, Backfilling & Levelling of road as it was earliar, laying of additional cable if necessary for cable jointing if loop is not available. |
| 5 | Straight Through Size 3*300 Sq MM (Provided by Agency) |
| 6 | Repairing of 33 KV Outdoor/Indoor Fault with the help of Jointing Kit |
| 7 | Outdoor / Indoor fault - Identifying the fault with the help of fault locator machine, lowering the cable, digging for loop, preparing the cable for filling the jointing kit testing of cable, pulling/coonecting to cable to pole/panel, energisastion of cable, levelling the road as it was in prior condition. |
| 8 | Jointing Kit Size 3*300 Sq MM (Provided by Agency). |
| 9 | 11KV Cable |
| 10 | 11 KV underground cable fault-Locating the fault with the help of fault location machine & Driver, Providing skilled cable Jointer & labour, digging trench with the help of road cutter/digging machine/tractor/manual etc. Size of trench 3 m. length x 1.5 m.width and upto depth of cable exposing the fault cable, preparing the cable , filling cable jointing kit, High pressure testing of cable, Backfilling & Levelling of road as it was earliar, laying of additional cable if necessary for cable jointing if loop is not available. |
| 11 | Straight Through Size 3*185 Sq MM (Provided by Agency) |
| 12 | Repairing of 11 KV Outdoor/Indoor Fault with the help of Jointing Kit |
| 13 | Outdoor / Indoor fault - Identifying the fault with the help of fault locator machine, lowering the cable, digging for loop, preparing the cable for filling the jointing kit testing of cable, pulling/coonecting to cable to pole/panel, energisastion of cable, levelling the road as it was in prior condition. |
| 14 | Jointing Kit Size 3*185 Sq MM (Provided by Agency) |
| 15 | LT Underground Cable |
| 16 | Repairing of LT Underground cable Fault with the help of Straight Through |
| 17 | LT underground cable fault-Locating the fault with the help of fault location machine & Driver, Providing skilled cable Jointer & labour, digging trench with the help of road cutter/digging machine/tractor/manual etc. Size of trench 3 m. length x 1.5 m.width and upto depth of cable exposing the fault cable, preparing the cable , filling cable jointing kit, High pressure testing of cable, Backfilling & Levelling of road as it was earliar (Sufficient Sand Filling where Straight Through filling Work), laying of additional cable if necessary for cable jointing if loop is not available. |
| 18 | Straight Through Size 3*95 Sq mm (Provided by Agency) |
| 19 | Straight Through Size 3*95 Sq mm (Provided by Agency) |
| 20 | Straight Through Size 3*120 Sq mm (Provided by Agency) |
| 21 | Straight Through Size 3*240 Sq mm (Provided by Agency) |
| 22 | Road restoration Charges Please Enable Macros to View BoQ information |