| 1 | cremetorium maintainance |
| 2 | OD45927/2026-2027:Demolishing dry rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement Mortar |
| 3 | OD45943/2026-2027:Dry Rubble Masonry-Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials, labour charges etc. |
| 4 | OD45950/2026-2027:Dry rubble masonry with with DEPARTMENT RUBBLE. complete as per direction of departmental officers at site. |
| 5 | 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 6 | OD34079/2026-2027:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.350 mm (+0.05%), total coated thicknesswith zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxyprimer on both side of the sheet and polyester top coat 15-18 microns. Sheet should haveprotective guard film of 25 microns minimum to avoid scratches during transportation andshould be supplied in single length upto 12 metre or as desired by Engineer-in-charge. Thesheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever required.(Modified 12.50) |
| 7 | 15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar |
| 8 | 50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 9 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 10 | 13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm |
| 11 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 12 | 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 13 | 10.25.1:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 14 | OD49461/2026-2027:Supplying and fixing Acrylic 3D Lettering English or Malayalam of size 10-15cm,20-30mm projection etc complete as per the direction of engineer in charge at site |
| 15 | OD49462/2026-2027:Supplying and fixing GI /AI Sheet Please Enable Macros to View BoQ information |