| 1 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and as directed by Engineer-in- charge. |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick, in any type of soilcomplete all as specified and as directed by Engineer-in- charge. |
| 3 | Removing excavated material/soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc.1.5 mtr above the starting point, complete all as specified and as directed by Engineer-in- charge. |
| 4 | Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as spefied and as directed by Engineer-in-Charge. (Note:- Punned thickness shall be considered for payment purpose) |
| 5 | Supply and laying Best quality, locally available, sub class ‘B’ burnt clay bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge. |
| 6 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 95 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 7 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 70 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 8 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 50 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 9 | Supply and laying replacement , jointing and testing galvanized iron 100 mm bore medium grade pipe (ISI marked) with and including all necessary fittings such as elbow, Tee, union , nipples etc as requried at site laid in trench complete all as specified and as directed by Engineer-in-Charge.Note: Earh work such as exavation, returning and removal shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ. |
| 10 | Supply & Fixing in replacement off load Changeover switch , 415 volts , 50Hz ,TPN , 4 Pole , 100 Amps capacity, enclosed in sheet metal enclosure , floor/ wall mounter complete with handle mechanism, interlocking arrangements, connections , and all accesories compete all as per manufacturer's instructions , compete all as specified and directed by Engineer-in-Charge. |
| 11 | Supply & Fixing in replacement off load Changeover switch , 415 volts , 50Hz ,TPN , 4 Pole , 160 Amps capacity, enclosed in sheet metal enclosure , floor/ wall mounter complete with handle mechanism, interlocking arrangements, connections , and all accesories compete all as per manufacturer's instructions , compete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply and Fabrication, installation , testing and commissioning in replacement Factory made , IP-54 , CPRI approved , Outdoor type , LT Panel Board , not less than 120 cm x 100 cm x 60 cm made out of CRCA sheet 3.15 mm thick , dust proof, verming proof, powder coated from both side, individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply including bus bar chamber and Aluminium bus bar of capacity 300 Amps rating for phase and neutral mounted on hygroscopic insulator fixed in a separate bus bar chamber separate compartment for incoming and outgoing feeder prewired with suitable size of copper conductor cable including fitted on 50mm x 50mm x 6mm angle iron channel with PCC (1:3:6) bedding upto a height of 30cm above ground level and 30cm foundation complete all as specified and as directed by Engineer-in-Charge and provision of lugs and bushing for housing the following:-(i) Aluminium bus bar 300 amps for phase & neutral-04 Nos.(ii) MCCB 4P , 200Amps, 36 KA - 01 No.(Incoming) (iii) MCCB 4P , 100 Amps, 36 KA - 02 Nos. (Out going) iv) MCCB 4P , 32 Amps, 36 KA - 02 Nos. (Out going)(iv) MCCB 4P , 63 Amps, 36 KA - 03 Nos. (Out going)(v) Multi functional digital Voltmeter and ampere meter including suitable and appropriate CTs-01 Set(vi) Indicator lamp (LED R-Y-B)- 01 Set of three. Note: Make and complete detailed drawings of the LT Panel shall be submitted to and approved by the GE prior to procurement / manufacture . The panel shall be executed strictly as per approved drawings and specifications complete all as specified and as directed by Engineer-in-charge. |
| 13 | Supply and Fabrication, installation , testing and commissioning in replacement Factory made , IP-54 , CPRI approved , Outdoor type , LT Panel Board , not less than 100 cm x 90 cm x 60 cm mounted outdoor made out of CRCA sheet 3.15 mm thick dust proof, powder coated from both side, individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply including bus bar chamber and Aluminium bus bar of capacity 250 Amps rating for phase and neutral mounted on hygroscopic insulator fixed in a separate bus bar chamber separate compartment for incoming and outgoing feeder prewired with suitable size of copper conductor cable including fitted on 50mm x 50mm x 6mm angle iron channel with PCC (1:3:6)bedding upto a height of 30cm above ground level and 30cm foundation complete all as specified and as directed by Engineer-in-Charge and provision of lugs and bushing for housing the following:-(i) Aluminium bus bar 250 amps for phase & neutral-04 Nos (ii) MCCB 4P , 160 Amps, 36 KA - 01 No.(Incoming)(iii) MCCB 4P , 100 Amps, 36 KA - 02No. (Out going)(iv) MCCB 4P , 63 Amps, 36 KA - 02 No. (Out going)(v) Multi functional digital Voltmeter and ampere meter including suitable and appropriate CTs-01 Set(vi) Indicator lamp (LED R-Y-B)- 01 Set of three. Note: Make and complete detailed drawings of the LT Panel shall be submitted to and approved by the GE prior to procurement / manufacture . The panel shall be executed strictly as per approved drawings and specifications complete all as specified and as directed by Engineer-in-charge. |
| 14 | Supply and Fabrication, installation , testing and commissioning Factory made , IP-54 , CPRI approved , Outdoor type , not less than 100cm x 80cm x 60 cm mounted outdoor made out of CRCA sheet 3.15 mm thick dust proof, powder coated from both side, individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply including bus bar chamber and copper bus bar of capacity 200 Amps rating for phase and neutral mounted on hygroscopic insulator fixed in a separate bus bar chamber separate compartment for incoming and outgoing feeder prewired with suitable size of copper conductor cable including fitted on 50mm x 50m x 6mm angle iron channel with PCC (1:3:6)bedding upto a height of 30cm above ground level and 30cm foundation complete all as specified and as directed by Engineer-in-Charge and provision of lugs and bushing for housing the following:-(i) Aluminium bus bar 200 amps for phase & neutral-04 Nos. (ii) MCCB 4P , 100 Amps, 36 KA - 01 No.(Incoming)(iii) MCCB 4P, 63 Amps, 36 KA - 02 Nos. (Out going)(iv) MCCB 4P , 32 Amps, 36 KA - 02 Nos. (Out going)(v) Multi functional digital Voltmeter and ampere meter including suitable and appropriate CTs-01 Set(vi) Indicator lamp (LED R-Y-B)- 01 Set of three.Note: Make and complete detailed drawings of the LT Panel shall be submitted to and approved by the GE prior to procurement / manufacture . The panel shall be executed strictly as per approved drawings and specifications complete all as specified and as directed by Engineer-in-charge. |
| 15 | Taking up / down existing 100mm bore cast iron (CI) pipe line / water main of any description, complete with all fittings, accessories and fixtures existing in the line, by carefully dismantling and opening all types of joints including Tyton, rubber gasket and lead joints, complete all as specified and directed by the Engineer-in-Charge. Notes:Notes:(a) Earth work such as excavation, returning filling and removal for pipe line shall be measured and paid for separately under relevant items of Schedule 'A' BoQ.(b) Where old and new pipe lines are laid/relaid along the same alignment/location, earth work such as excavation, returning filling and removal shall be measured and paid only once. No duplicate measurement shall be admissible on this account. |
| 16 | Laying only in trenches, flanged cast iron (CI) pipes 100mm bore of any description/grade, in any position (horizontal or vertical), as retrieved from serial item No. 15.00 here- in-before, removing rust and corrosion by thoroughly cleaning the surface with emery paper of pipes and including necessary cutting, additions and alterations, welding, with and including Bituminous paint (Bitumen coating) on external surfaces of pipe, with and including jointing with fibre board gasket described under clause 18.48.6 of SSR Part-I 2009 and with and including fitted with nuts, bolts and washers of appropriate size complete all as specified and directed by Engineer-in-Charge . Note :-(i) Earth work such as excavation, returning filling and removal and Cast Iron specials fittings of the pipes shall be measured and paid for separately under appropriate item of Schedule `A' BoQ.2. The rate of jointing material such as fibre board gasket, nuts , bolts and washers of appropriate size and biumenious paint on external surfaces of pipe is included in this item. contractor shall quote his rates accordingly. Nothing shall be paid extra on this account.3 Where old and new pipe lines are laid/relaid along the same alignment/location, earth work such as excavation, returning filling and removal shall be measured and paid only once. No duplicate measurement shall be admissible on this account. |
| 17 | Supplying, laying, jointing & testing Cast Iron pipes 100 mm bore with flanged ends , vertically cast, class B conforming to IS 1537 : 1976 ( laying in trenches or vertically at OHT ), jointing with fibre board gasket described under clause 18.48.6 of SSR Part-I 2009 and fitted with nuts, bolts and washers of appropriate size complete all as specified and directed by Engineer-in-Charge . Note :-(i) Earth work such as excavation, returning filling and removal and Cast Iron specials fittings of the pipes shall be measured and paid for separately under appropriate item of Schedule `A' BoQ.2. The rate of jointing material such as fibre board gasket, nuts , bolts and washers of appropriate size is included in this item. contractor shall quote his rate accordingly. Nothing shall be paid extra on this account.3 All pipes shall be factory coated Bituminous paint both externally and internally as described under clause 18.2.4.6 of SSR Part-I 2009. The rate of this aspect is also included in this item and contractor shall quote his rates accordingly. Nothing shall be paid extra on this account.4. Where old and new pipe lines are laid/relaid along the same alignment/location, earth work such as excavation, returning filling and removal shall be measured and paid only once. No duplicate measurement shall be admissible on this account. Please Enable Macros to View BoQ information |
| 18 | Supplying, laying, jointing & testing Cast Iron pipes 100 mm bore with flanged ends , vertically cast, class B conforming to IS 1537 : 1976 ( laying in trenches or vertically at OHT ), jointing with fibre board gasket described under clause 18.48.6 of SSR Part-I 2009 and fitted with nuts, bolts and washers of appropriate size complete all as specified and directed by Engineer-in-Charge . Note :-(i) Earth work such as excavation, returning filling and removal and Cast Iron specials fittings of the pipes shall be measured and paid for separately under appropriate item of Schedule `A' BoQ.2. The rate of jointing material such as fibre board gasket, nuts , bolts and washers of appropriate size is included in this item. contractor shall quote his rate accordingly. Nothing shall be paid extra on this account.3 All pipes shall be factory coated Bituminous paint both externally and internally as described under clause 18.2.4.6 of SSR Part-I 2009. The rate of this aspect is also included in this item and contractor shall quote his rates accordingly. Nothing shall be paid extra on this account.4. Where old and new pipe lines are laid/relaid along the same alignment/location, earth work such as excavation, returning filling and removal shall be measured and paid only once. No duplicate measurement shall be admissible on this account. Please Enable Macros to View BoQ information |