| 1 | Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets,regulators light fittings) and removal from site and making good the disturbed surfaces of (wall/floors/ceiling etc) complete all as specfied & directed. |
| 2 | Material & Labour for point wiring with 1.5 sqmm (nominal size) single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed FRLSH electrolytic copper conductor cable conforming to IS 694:2010 with and including continuous earth wire of size 1.5 sqmm (nominal size) single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed, FRLSH electrolytic copper conductor cable and connected to earth dolly, colour coded as per IS 11353:1985 drawn through an including concealed medium grade, PVC conduit of 20 mm dia (Nominal bore) or higher, minimum wall thickness 1.6 mm conforming to IS 9537(Part 3):1983 for conduits complete with and including all conduit accessories (conforming to IS 3419:1988 for conduit accessories) and factory made not less than 1.2 mm thick sunken modular flush sheet galvanised metal enclosure having zinc coating not less than 120 GSM conforming to IS 14772:2000 having bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover plate with frame and making good of disturbed surfaces of wall/ceiling/floor etc complete all as specified in IS 732:2019 and directed by Engr-in-Charge at site for the following :- |
| 3 | One light/fan/bell/Exhaust fan/Fresh Air Fan point controlled by one way switch 5 amps. (Switch to be measured and paid separately) complete all as specified and directed. |
| 4 | Material & Labour for point wiring with 2.5 sqmm (nominal size) single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed FRLSH electrolytic copper conductor cable conforming to IS 694:2010 with and including continuous earth wire of size 2.5 sqmm (nominal size) single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed, FRLSH electrolytic copper conductor cable and connected to earth dolly, colour coded as per IS 11353:1985 drawn through an including concealed medium grade, PVC conduit of 20 mm dia (Nominal bore) or higher, minimum wall thickness 1.6 mm conforming to IS 9537(Part 3):1983 for conduits complete with and including all conduit accessories (conforming to IS 3419:1988 for conduit accessories) and factory made not less than 1.2 mm thick sunken modular flush sheet galvanised metal enclosure having zinc coating not less than 120 GSM conforming to IS 14772:2000 having bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover plate with frame and making good of disturbed surfaces of wall/ceiling/floor etc complete all as specified in IS 732:2019 and directed by Engr-in-Charge at site for the following :- |
| 5 | One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board. (Switch and socket to be measured and paid separately) |
| 6 | One 3 pin 5 Amps socket outlet point controlled by one way switch on same board along with other switches. (Switch and socket to be measured and paid separately) |
| 7 | One 3 pin 6/16 Amps socket outlet point controlled by one way switch on independent board. (For Power Point) |
| 8 | Material & Labour for point wiring with 4.0 sqmm (nominal size) single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed FRLSH electrolytic copper conductor cable conforming to IS 694:2010 with and including continuous earth wire of size 4.0 sqmm (nominal size) single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed, FRLSH electrolytic copper conductor cable and connected to earth dolly, colour coded as per IS 11353:1985 drawn through an including concealed medium grade, PVC conduit of 20 mm dia (Nominal bore) or higher, minimum wall thickness 1.6 mm conforming to IS 9537(Part 3):1983 for conduits complete with and including all conduit accessories (conforming to IS 3419:1988 for conduit accessories) and factory made not less than 1.2 mm thick sunken modular flush sheet galvanised metal enclosure having zinc coating not less than 120 GSM conforming to IS 14772:2000 having bottom, side and back-wall knockouts for conduit entry from any direction for one 3 pin AC Box outlet 20 Amps concealed and making good of disturbed surfaces of wall/ceiling/floor etc complete all as specified in IS 732:2019 and directed by Engr-in-Charge. (For AC point) |
| 9 | Identifying and rectifying the defects pertains to ceiling fans/exhaust fans/fresh air fans and connects electric circuit, tightening of loose wiring/conduits/ fan capacitors and connection carrying out minor repairs incl blade alignments,screwing/tightening the nuts/bolts/washers etc incl taking down & refixing properly in the same position after repairs, complete all as specified and directed. |
| 10 | M&L for rewinding of ceiling fans of any type and make with super enamelled copper wire of appropriate gauge suiatble for existing make in the workshop including necessary lathe work on shaft, both sides of rewinding covered with high quality varnish and provisions of new nuts/pins including taking out old burnt wind of copper/aluminium complete all as specified and directed. |
| 11 | Ditto- all as per Item No. 8 here-in-before but Air ventilation PVC body/ metal body exhaust fan of size 200/230/300 mm sweep.complete all as specified and directed. |
| 12 | M&L for overhauling of celing fan 1200mm/1400mm by greasing and oiling,replacement of unserviceable/defective components, except rewinding of starter winding complete all as directed. |
| 13 | Note Sl.No. 8 : (a) Spare parts found unserviceable/defective will be measured and paid separately under relevant item as Supply and fix in repair . complete all as specified and directed. |
| 14 | Supply in repairs/replacements of following spare of Ceiling fan 1200mm /1400mm sweep of different make :- complete all as specified and directed. |
| 15 | S&F in repair MS clamp with rubber reel, nuts, bolts, split pin etc suitable for 1200/1400 mm sweep ceiling fan complete all as specified and as directed. |
| 16 | Ball bearing of size 6201/6202 as per sample complete all as specified and directed. |
| 17 | Gun metal bush as per sample. complete all as specified and directed. |
| 18 | Fan canopy pvc body, white in colour, suitable for existing fan, as per sample and directed. |
| 19 | S&F in repair of MS down rod 300/450 mm for fixing of ceiling fan complete all as specified and as directed. |
| 20 | M&L for taking down & refixing and repair of BLDC ceiling fans of any type and make complete including repair/replacement of PCB & ball bearing as requirment and provisions of new nuts and pins for 1200 sweep as per site reqiurement complete all as specified and as directed. |
| 21 | M&L in repair louver shutter of exhaust fan suitable for 300 mm size at the height from 3 mtr to 14 mtr height making good surface of disturbed area complete all as specified & directed.Note: Contractor shall arrange suitable T&P including necessary form work, scaffolding and safety measures to fix properly the exhaust fan shutter complete all as specified and directed. |
| 22 | M&L for Overhauling/Dismantling of defective/rusted Geyser of 25 Ltr capacity, removing inlet/outlet connections, taking out U/S parts by unscrewing bolts and nuts etc. Checking defects and re-assembling the Geyser after refixing serviceable/new parts & cleaning, dicling and refixing only serviceable items and re-installing the Geyser in suitable place/position and connecting inlet-outlet connections & testing complete, all as specified and directed by Engr-in-charge.Note:(a) Items required for replacement of U/S parts will be measured and paid separately under relevant item of sch \\"A\\" ). |
| 23 | Supply in repairs/replacements of following spare parts of geyser storage type of different make for capacity 25 ltrs all as samples as required.complete all as specified and directed. |
| 24 | Apparatus assembly duly prewired without heating element and thermostat/thermal cutout.complete all as specified and directed. |
| 25 | Indication lamp (Green/Red) as per sample.complete all as specified and directed. |
| 26 | Thermostat as per sample.complete all as specified and directed. |
| 27 | Heating element 2.0 KW round, square, triangular bottom suitable for 25 Ltrs or as per sample complete all as specified and directed. |
| 28 | Cover outer for geysers suitable for any make/capacity/type of Geysers installed at site duly painted with two quotes with enamel (Deco) paint of colour & shade complete all as specified and directed |
| 29 | Stainless Steel inner tank of 25 Ltrs capacity complete all as specified and directed as . |
| 30 | Bottom and top cover for Geysers suitable for any make/capacity/type of Geysers installed at site duly painted with two quotes with enamel (Deco) paint of colour & shade complete all as specified and directed. |
| 31 | Geyser SS braided pipe of 12 mm (internal dia) suitable for hot/cold water, 600 mm long with nuts and rubber washers complete all as specified and directed. |
| 32 | Taking down DBs,VTPN DBs of any make and type from the site and making good to the disturbed surfaces complete all as specified and directed. |
| 33 | S&F of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43, IK 9 protection) fixed flush to wall and suitable for universal mounting and including 100 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IEC 61439-3 including taking down old DBs all as specified and directed.NOTE :-(a) MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. |
| 34 | S & F sheet metal enclosure MCB DB TPN 4 way with 100 Amps rated copper bus bar 415 volts with metal double door, IP-43 & IK 9 protection, with provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP MCB's as outgoings, including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good the disturbed surface to match with existing one, complete all as specified and as directed. |
| 35 | S&F of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-43 & IK 9 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 100 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for 100 Amps, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings including blank spacer for blank space complete all as specified and conforming to IEC 61439-3 including taking down old DBs all as specified.NOTE :-(a) MCBs/MCCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. |
| 36 | S&F of sheet metal enclosure SP and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amps, 240 v, 50 Hz AC made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete all as specified and directed. |
| 37 | S&F in repair amp rating 240V, 50 Hz AC made from moulded self-extinguishing thermostat plastic and suitable for ‘B/C’ curve, 10 KA breaking capacity conforming to IEC 60898-1:2002 miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.complete all as specified and directed. |
| 38 | (i) SP 6 To 32 AMP, complete all as specified and directed. |
| 39 | (iii) SPN 40 to 63 AMP, complete all as specified and directed. |
| 40 | S&F in repair 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN 63-100 amp 4 pole complete all as specified and directed. |
| 41 | S&F in repair RCBO, 230 Volt, 40 Amp, 30mA, 50 Hz, with 10 kA short circuit capacity of double pole for ensuring protection from leakage current, short circuit & over load, complete all as specified and as directed. |
| 42 | Taking down carefully sub main wiring three single run 6/10 Sqmm of any make and type complete all as directed. |
| 43 | Supply, laying and drawing submain wiring in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of multistranded copper conductor PVC insulated, FRLSH, unsheathed cables of 1100 Volts grade conforming to IS 694:2010 complete including taking down existing old wire all as specified and directed. Note :- Two runs of IC x 6.00 sqmm (Phase wire and neutral ) and one run of IC x 6.00 sqmm (as earth wire) will be measured as one unit length. |
| 44 | S&F in repair MCCB 100 Amps, 4 pole 16 KA at 415 V, 50 Hz conforming to IEC 60947-2 with fixed thermal magnetic release complete all as specified directed. |
| 45 | S&F in repair MCCB 125 Amps, 4 pole 16 KA at 415 V, 50 Hz conforming to IEC 60947-2 with fixed thermal magnetic release complete all as specified directed. |
| 46 | S&F in repair MCCB 160 Amps, 4 pole 16 KA at 415 V, 50 Hz conforming to IEC 60947-2 with fixed thermal magnetic release complete all as specified directed. |
| 47 | M&L in replacement of earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.50 m below GL) connected with GI earth lead wire 4.0 mm as earthing leads by means of bolts, nuts, check nuts and washers all joints as shown on drawings and including excavation, earth work. GI pipe light grade 15 mm bore for protection of GI earth wire from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1 chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as secified and directed at site. |
| 48 | S&F in repair copper wind motor, single phase, 240V suitable for PVC fresh air fan of sweep size 225/ 250/300 mm as per sample given at site complete all as specified and directed. |
| 49 | S&F in repair copper wind motor, single phase, 240V suitable for metallic heavy duty exhaust fan of sweep size 250/300/400 mm as per sample given at site complete all as specified and directed. |
| 50 | S&F in repair single core PVC insulated cable 1.5 Sqmm FRLSH 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits complete all as specified and directed. |
| 51 | S&F in repair single core PVC insulated cable 2.5 Sqmm FRLSH 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits complete all as specified and directed. |
| 52 | S&F in repair single core PVC insulated cable 6 Sqmm FRLSH 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits complete all as specified and directed. |
| 53 | S&F in repair copper cable flexible 2 core PVC insulated of size 40/.0076 ll complete all as specified and directed. |
| 54 | S&F in repair PVC insulated flexible cable three core copper conductor of size 1.00 Sqmm ISI marked covered with white colour round insulation complete all as specified & directed. |
| 55 | S&F in repair , 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC armoured, PVC sheathed 6 sq. mm nominal cross section, 2 core.complete all as specified and directed. |
| 56 | S&F in repair LED lights fitting mirror type with high out put diffuser 2 feet, 10 Watt ,220V,AC decorative box type with driver,holder and LED lamp incl. connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 57 | S&F in repair LED lights fitting (3.5 to 4 feet) 1x20Watt ,220V,AC decorative box type with driver,holder incl. system luminous efficacy 110 lumen/W, Power Factor ≥ 0.95, Rated Frequency - 50Hz, CCT - 6500K, Safe Operating Voltage - 140V to 270V,operating Temp : - 10 deg C to + 45 deg, CRI ≥ 80,THD ≤ 10,IP 20 & IK 3 protection, LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 58 | S&F in repair 35 watts 230 V AC outdoor type with High efficient LED Building security light fitting with high pressure die cast Aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP: 65/66 protected complete with bracket made out of 32 mm GI pipe light grade 1.2 mtr long bend to shape with clamps and fixing bolts all as specified and directed. |
| 59 | S&F in repair post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified & directed. |
| 60 | S&F in repair of 70 watt High efficient LED flood light fitting with pressure die-cast aluminium housing and toughened glass in the front, 230 V AC outdoor type with thermal management in multiple optics and equipped, IP 66 & IK 7 protection, system luminous efficacy 110 lumen/W, Power Factor ≥ 0.95, Rated Frequency - 50Hz, CCT - 6500K, Safe Operating Voltage - 140V to 270V,operating Temp : - 10 deg C to + 50 deg, CRI ≥ 80,THD ≤ 10 with impact and corrosion resistant complete with driver and lamp including all connection upto ceiling rose complete all as specified and directed. |
| 61 | S&F in repair of 100 watt High efficient LED flood light fitting with pressure die-cast aluminium housing and toughened glass in the front, 230 V AC outdoor type with thermal management in multiple optics and equipped, IP 66 & IK 7 protection, system luminous efficacy 110 lumen/W, Power Factor ≥ 0.95, Rated Frequency - 50Hz, CCT - 6500K, Safe Operating Voltage - 140V to 270V, CRI ≥ 80,THD ≤ 10 with impact and corrosion resistant complete with driver and lamp including all connection upto ceiling rose complete all as specified and directed. |
| 62 | S&F in repair of flat panel light aesthetically designed (2ft x2ft) LED flat panel for surface/recessed mounting type which provides soft-light and glare free symmetrical illumination 35/36 Watt fixture should have minimum system luminous efficacy 110 lumen/W, Power Factor ≥ 0.95, Rated Frequency-50Hz, CCT:5700K-6500K, Safe Operating Voltage - 140V to 270V, operating Temp : - 10 deg C to + 45 deg, CRI ≥ 80,THD ≤ 10, IP-20 & IK 3 protection with impact and corrosion resistant complete all as specified and directed. |
| 63 | S&F in repair ultra bright compact LED downlighter 12 Watts (round or square shape) with high efficiency LEDs ideally suitable for roof ceiling areas to give glare free light, complete all as specified and directed. |
| 64 | S&F in repair ultra bright compact LED downlighter 15 Watts (round or square shape) with high efficiency LEDs ideally suitable for roof ceiling areas to give glare free light, complete all as specified and directed. |
| 65 | S&F in repair LED Lamp of wattage 09 Watt, 90 lm/W, with PF >0.9 & CRI:80,protection againt high voltage upto 360V, B22 ,230 Volts,50 Hz,complete all as specified and directed. |
| 66 | S&F in repair Nut and Bolt full thread hexagon bolt mild steel of size (1/2x6) inch alongwith washer suitable for fixing of Geyser 25 ltrs. complete all as per site requirement all as specified and directed. |
| 67 | M&L in repair switch piano flush type 6 Amp SP one way complete all as specified and directed. |
| 68 | M&L in repair switch piano flush type 16 Amp SP one way complete all as specified and directed. |
| 69 | S&F in repair socket outlet 3 pin 6 Amp flush type complete all as specified and directed. |
| 70 | S&F in repair socket outlet 2 in 1,3 pin 6/16 Amps complete all as specified and directed. |
| 71 | M&L in repair ceiling rose 3 phase PVC polycorbonate,insulated body complete all as specified and directed. |
| 72 | S&F in repair switch type normal electronic fan regulator 5 step complete all as specified and directed. |
| 73 | M&L in repair bell ding dong AC,230 volts,single pole complete all as specified and directed. |
| 74 | M&L in repair Modular switch 1 way 6A,1 module, 230V, 50 Hz complete all as specified and directed. |
| 75 | M&L in repair Modular switch 1 way 16A,1 module, 230V, 50 Hz complete all as specified and directed. |
| 76 | S&F Modular socket 6A- 3 pin combined 2 module,230V, 50 Hz complete all as specified and directed. |
| 77 | S&F in repair Modular socket 6A/16A - 2/3 pin combined 2 module, 230V, 50 Hz complete all as specified and directed. |
| 78 | S&F in repair Modular ceiling fan regulator, step type for BLDC ceiling fan 1 or 2 module. (As per sample) |
| 79 | S&F in repair 15A plug top 240 Volt AC and connection complete all as specified and as directed |
| 80 | S&F in repair of SS combined 15 amp without Box complete all as specified and directed.(As per sample) |
| 81 | S&F in repair ceiling fan capacitor for 1200/1400 mm sweep 2.5 mfd all specfied and directed Please Enable Macros to View BoQ information |