| 1 | Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) including all type of tiling complete all as specified and directed. |
| 2 | M&L 75 mm thick PCC 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in sub base top layer of floor and finished rough to receive the floor tile etc complete all as specified and directed. |
| 3 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 4 | M&L Plain Cement Concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in copping etc complete all as specified and directed. |
| 5 | Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 6 | Boring holes 5m deep in soil for Single under reamed piles and getting out and disposal of soil to a distance of n.exc 50m (dia of pile 300mm) complete all as specified and directed. |
| 7 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foundation etc and getting out in soft/loose soil complete all as specified and directed. |
| 8 | M&L PCC 1:4:8 type-D2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete sub base as in floors complete all as specified and directed. |
| 9 | M&L for hard core of gauge n.exc 63 mm deposited, spread and levelled in layers n.exc 15 cm thick with broken bricks, watered and rammed to a true surface complete all as specified and directed. |
| 10 | Returning Filing in,including spreading, levelling, watering and well ramming in layers, not exc 25 cm in soft/loose soil complete all as specified and directed. |
| 11 | Removing excavated material n exc 50 m and depositing where directed at level n exc 1.5m above the starting point complete all as directed. |
| 12 | M&L for brick work using old size sub class 'B' brick straight or curved on plan exceeding 6.00 mtr mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 13 | M&L reinforced cement concrete (M-25 Design mix) (using 20 mm graded stone aggregate) as in foundation, footing, foundation beams, plinth beams, bases for columns, pedestal, under reamed piles, mass concrete, etc complete all as specified and directed. |
| 14 | M&L reinforced cement concrete (M-25 Design mix) (using 20mm graded stone aggregate) as in columns, pillars, posts, struts etc complete all as specified and directed. |
| 15 | M&L reinforced cement concrete (M-25 Design mix) (using 20mm graded stone aggregate) as in slabs supported on walls, beams and column in floors, roofs, landings, balconies, deck slabs and in shelves and the like complete all as specified and directed. |
| 16 | M&L RCC 1:2:4 type B1, (using 20mm graded stone aggregate) as in beams, cantilevers, bressmummers, lintels over 1.5 m span complete all as specified and directed. |
| 17 | M&L Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping) for flat rough finished surfaces of concrete. |
| 18 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) for foundation and plinth beams, and similar work, vertical or to batter complete all as specified and directed. |
| 19 | M&L form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished, square, rectangular or polygonal surfaces of concrete complete all as specified and directed. |
| 20 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. |
| 21 | Formwork to sides and soffts of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as spd and as directed. |
| 22 | Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 23 | The same as per item No 22 above but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 24 | M&L 15 mm thick rendering in two layers (10 mm & 5mm ) on fair faces of bk / concrete surfaces in cm (1:4) with WPC (WPC shall be measured & paid separetely) finished even and smooth (Without using extra cement ) complete all as specified and directed. |
| 25 | Supply only water proofing compound (liquid), ISI marked. |
| 26 | M&L 15 mm thick rendering on fair faces of bk /concrete surfaces in cm (1:6), finished even and smooth (Without using extra cement ) complete all as specified and directed. |
| 27 | M&L rendering 10mm thick in CM 1:4 on concrete surfacves/ chajal ceiling, etc finished even and smooth without using extra cement complete all as specified and directed. |
| 28 | Preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of white wash complete all as specified and directed. |
| 29 | M&L for Prepration of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 30 | M&L for preparation of newly plastered surfaces of wall & concrete and applying 2 mm thick wall care putty including preparation complete all as specified and directed. |
| 31 | M&L for applying two coats of oil bound distemper on wall or concrete over a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed. |
| 32 | M&L for 75mmn thick plain cement concrete 1:3:6 type C2 using 4Omm graded stone aggregate as in plinth protection joint filled with bitumen sand mixer 50mm thick finished even and smooth without using extra cement complete all as specified and directed. |
| 33 | M&L, treating under plinth protection at the rate of 5 litres of emulsion per square meter of surface of flooring complete all as specified and directed. |
| 34 | S&F for powder coated aluminium door frame with shutter made out of following section complete fixed to position with hold fast all as specified & directed (a) chowkhat frame of size 101.45 x 44.45 x 1.87 mm thick weight @ 1.92Kg/RM (b) Style and Vertical member of size 83.50 x 44.45 x 1.90 mm thick weightn @0.911Kg/RM (c) Top and bottom rail of size 11.60 x 44.45 x 2.00 mm thick weight @ 1.511kg/RM (d) Middle rail of size 49.91x 44.45x 2.01 mm thick weight @ 1.072Kg RM (e) Top panel with 5.00 mm thick tinted glass fixing with rubber gasket. (f) Bottom panel with 5 to 6 mm thick Alumnium composite panel thick with clips (g) 100 mm dia round handle disc type -02 nos & Alu tower bolt 200mm -01 No, Hinges 04 Nos each shutter. (h) Aluminum and PVC beading as per requirment as in fixing for paticle board & Glass, jointing cleat including locking arrangement etc |
| 35 | S&F powder coated aluminium window sliding shutter three track with following specification: (a) chowkhat frame of size 92 x31.75 x2 mm thick weight @ 0.1.490Kg/RM (b) Style and Vertical member of size 40 x 27.2 x 2 mm thick weight @0.798Kg/RM (c) Top and bottom rail of size size 40 x 27.2 x 2 mm thick weight @0.798Kg/RM (d) Partialy 0.63 mm dia stainless steel wire netting mosquito proof with fixing arrangment. (e) Partialy 5.00 mm thick tinted glass fixing with rubber gasket. (f) Aluminum and PVC beading as per requirment as in fixing for paticle board & Glass, jointing cleat including locking arrangement. etc |
| 36 | S&F anodized aluminium grill (diamond shape of approx size 100x100mm) made out of aluminium flat of size 4x5mm as approved by GE for window/ ventilators etc complete all as specified and directed. |
| 37 | M&L for 10mm thick Lighft shade vitrified ceramic tiles in floors exceeding 0.36 Sqm but not exceeding 0.42 Sqm set & jointed in neat cement slurry and pointed in white cement mixed with pigments to match the shade of tiles over and incl 15 mm thick screed bed or bedding layers of cement mortar 1:6 complete all as specified and directed. |
| 38 | M&L for 10mm thick Light shade vitrified tiles in skirting, exceeding 0.36 sqm but not exceeding 0.42 sqm set & jointed in neat cement slurry and pointed in in white cement mixed with pigments to match the shade of tiles over and incl 10 mm thick rendering or bedding layers of cement mortar 1:4 complete all as specified and directed. |
| 39 | M&L PCC 1:2:4 type B0, (using 12.5mm graded stone aggregate) as in roof /padding/kerb/sunken slab etc complete all as specified and directed. |
| 40 | MIL Rendering 15 mm thick in cement mortar 1:3 on concrete surfaces with liquid water proofing compound @ 200 ml/50 kg per bag of cement or as per manufacturar instruction finished even and smooth without using extra cement over roof slab complete all as specified and directed. NOTE: water proofing compound shall be measured and paid seperately |
| 41 | Material and labour for cleaning surfaces and applying evenly a coat of hot blown bitumen grade 85/25 @ 1.20 Kg per Sgm over a coat of bituminous based primer @ 0.30 Kg per Sqm till the surface is properly impregnated. After the application of the bitumen, provide polymeric water proofing membrane of approved quality weighting not less than 3 Kg per Sqm with 100 mm over laping and bonded completely to the substrata and the over laps sealed / fused by flame or by bitumen as per manufacturers instruction. After the membrane is laid a layer of blown bitumen grade 85/25@ 1.20 Kg/ Sqm shall be applied and one coat of aluminium paint at the rate of 100 gram per sqm as per manufacturer instruction over bituminous layer complete all as specified and directed. . NOTE:- The polymeric water proofing membrane shall be extended upto parapet walls and inserted in walls by cutting groove and making good with cement mortar 1:3 as directed. |
| 42 | M&L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories for concealed wiring for one light/fan/bell/buzzer / exhaust fan point controlled by one, one way switch, including concealed pressed steel terminal box of required size not less than 1.0 mm thick factory made duly painted inside & outside with two coats of black bituminous paint over & including a coat of red oxide primer, with 2.8 mm thick top cover of plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting & making good disturbed surface & applying finishes to match existing surface complete all as specified and directed. |
| 43 | The same as item No. 42 here-in-before but one 3 pin, 5amp socket out let on independent board complete all as specified and directed. |
| 44 | The same as item No.42 here-in before but 3pin ,5amp socket out let on the same board with other switch complete all as specified and directed. |
| 45 | M&L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 4.0 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories for concealed wiring for one light/fan/bell/buzzer / exhaust fan point controlled by one, one way switch, including concealed pressed steel terminal box of required size not less than 1.0 mm thick factory made duly painted inside & outside with two coats of black bituminous paint over & including a coat of red oxide primer, with 2.8 mm thick top cover of plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 4 Sqmm FR type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting & making good disturbed surface & applying finishes to match existing surface complete all as specified and directed. |
| 46 | M&L sub main wiring with one single core PVC insulated & unsheathed cable 6.0 Sqmm (nominal area) FRLS type having multi-stranded copper conductor drawn in and including not less than 20 mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories for concealed wiring with and including 6.0 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as earth wire connected to common earth as per IS & cutting chasing for conduit & sinking for boxes & making good to walls disturbed surface & applying finishes to match existing surface complete including taking down of exsting sub main wiring complete all as specified and directed. |
| 47 | S & F Modular metal flush box 1/2 module |
| 48 | S & F Modular metal flush box 3 module |
| 49 | S & F Modular metal flush box 8 modules(Horizontal) |
| 50 | S & F modular white cover plate 1 module |
| 51 | S & F modular white cover plate 2 module |
| 52 | S & F modular white cover plate 3 module |
| 53 | S & F modular white cover plate 8 (Horizontal) modules |
| 54 | Supply & fixing switch modular flush type 6 amps, single pole, one way complete all as specified and directed. |
| 55 | Supply & fixing socket modular flush type suitable for 6 amp, 2/3 module combined 2 module complete all as specified and directed. |
| 56 | Supply & fixing switch modular flush type 16 amps, single pole, one way complete all as specified and directed. |
| 57 | Supply & fixing socket modular flush type suitable for 6/16 A, 2/3 pin combined 2 module complete all as specified and directed. |
| 58 | S&F ceiling rose single phase , PVC poly carbonate,insulated body three terminals ISI marked complete all as specified and directed. |
| 59 | S& F for sheet metal enclousre factory made for MCB DB's SPN, 12 way, double door, 240 Volts with 200 Amp rated bus bars including taking down existing unserviceable MCB DB complete all specified and directed. |
| 60 | S&F MCB SP 240 Volt 6 TO 40 Amp ISI marked conforming to 'C\\" curve, breaking capacity 10 KA complete all as specified and directed. |
| 61 | S&F MCB SPN 40-63 amp 30mA for earth leakage. Over load and short circuit protection ISI marked complete all as specified and directed. |
| 62 | Supply & fixing fan regulator, modular type, socket type to be used with BLDC fans ,single phase complete all as specified and directed. |
| 63 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type Extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser , 4 ft,2000lm,voltage protection range 140V -270 V,NW 4000K ,connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 64 | Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency warm type PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all specified and directed. |
| 65 | Supply, fixing and testing of ceiling fan 1200 mm sweep, heavy duty, single phase, AC, 230 Volts, 50Hz, BEE 5 star rating, ISI marked complete with down rod, canopy, blades, BLDC motor without remote and electronics fan regulator etc with 5 year on site warranty and connecting up complete including complete connection from ceiling rose to fan including writing of MES Number with synthetic enamel paint with depositing old fan to MES store for further BER complete all as specified and as directed. |
| 66 | S & f single pole and neutral encl 240 V with two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed. |
| 67 | Excavating in post holes in soft/loose soil (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 68 | M&L PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundation, Filling and mass concrete complete all as specified and directed. |
| 69 | S & F roof trusses (framed), trussed purlins, crane ganteries, rails and fastening and heavy bracket framing (Beam, Tee, angel channel or flat sections) including distance pieces cleats etc complete all as specified and directed. |
| 70 | S&F Pre-printed galvalume aluminium zinc coating GI based corrugated/semi corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw/ L-type or J type cranked hook complete all as specified and directed. |
| 71 | S&F Pre-printed galvalume aluminium zinc coating GI based plane steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw/ L-type or J type cranked hook complete all as specified and directed. |
| 72 | M & L preparation of new steel surfaces any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed. Please Enable Macros to View BoQ information |