| 1 | Dismantling of wrought iron or mild steel work of any description and any position complete all as specified and directed. |
| 2 | M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 3 | M&L for framed work such as grills, gratings, angle etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 4 | S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 5 | M&L for 4mm dia galvanised steel wire, 100x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified as directed. |
| 6 | M&L for Preparation of new painted steel surfaces of any description over 10cm width or grith not otherwise described and applying two coat of synthetic enamel paint over one coat of red oxide and zinc chrome complete all as specified and as directed. |
| 7 | Dismantling water tanks of capacity exc 250 litrs but n exc 500ltrs complete all as specified and directed. |
| 8 | Dismantling water tanks of capacity exc 500 litrs but n exc 1000ltrs complete as specified and directed. |
| 9 | S&F in repair for Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 500 ltrs hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. |
| 10 | S&F in repair for Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 1000 ltrs hoisted and fixed in position all as specified in SSR Part I complete all as specified and direcetd. |
| 11 | S&F in repairs for 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm- 690 gms) fixed complete all as specified and directed. |
| 12 | S&F in repairs PVC water tank protection cover/spike cover at top portion of tank cover /lid with thread/lock type in two phase i.e. outer and inner dia is 17'' lock dia 14'' round shape any colour suitable for 500 ltr and 1000 ltr water storage tank,fixed with screwed with outer and inner dia and one portion fixed with screwed in tank complete all as specified and directed. |
| 13 | M&L for Cleaning and removing all scale and dirt, etc, from existing water storage tanks and from mouths of circulating pipes, etc.and washing down with detergent powder of capacity exceeding 250 litres and not exc 500 ltrs by emptying,drying and cleaning the tank by scrubbing the dust with wire brush from tank including cleaning from mouths of circulating pipes,to entire satisfaction o Engr-in-Charge including writing date of cleaning and next due date with oil paint of visible colour in font size less than 100 mm high complete all as specified and directed.Note: The rates includes for disconnecting of existing water tank, lowering if required and hoisting,reconnecting and fixing in same position after cleaning. |
| 14 | M&L for Steel work for Stairs (framed) including stringers, treades, landing,balusters, hand rails etc. including cleats, brackets, etc. complete Fe-410-W (Gde-E-250) quality B including welding to stringer complete all as specified and directed. |
| 15 | S&F Mild steel screw bolts (machine made) 16mm to 20mm dia of neck with hexagonal or square heads at one end and screwed the other, or screwed both ends and screwed other end or screed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 5cm but exc 10 cm but n.exc 15 cm long complete all as specified and directed. |
| 16 | Excavation in post holes (or similar holes) each n.exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n.exc 50m and making good surface (Soft/loose soil) complete all as specified and directed. |
| 17 | Demolition of cement concrete unreinforced of any description & any position and disposing of the rubbish materials in low laying areas of defence land complete all as specified and as directed. |
| 18 | M&L for cement conrete 1:3:6 type C2 using (40mm graded stone aggregates) as in foundation filling and mass concrete complete all as specified and directed. |
| 19 | M&L for 100 mm thick; Plain Cement Concrete (PCC) 1:2:4 Type B-2 using (40mm graded stone aggregate), as in top layer of the floor, pavings etc., including finishing the surface by spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all specified and directed. |
| 20 | Taking up or down 15mm dia bore GI tubing and connections,,including cleaning for for fixing or removal to store complete all as specified and directed. |
| 21 | Taking up or down 20mm dia bore GI tubing and connections,,including cleaning for for fixing or removal to store complete all as specified and directed. |
| 22 | S&F in repairs 15mm dia bore GI tubing medium grade,galvanised with all fitting fixed to wall and ceiling or laid in floors complete all as specified and directed. |
| 23 | S&F in repairs 20mm dia bore GI tubing medium grade,galvanised with all fitting fixed to wall and ceiling or laid in floors complete all as specified and directed. |
| 24 | Taking down CI/AC/PVC pipes jointed in cement mortar etc and taking eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) including all type of bend pieces complete all as specified and directed. |
| 25 | S&F in repairs 75 mm bore PVC (SWR) pipes single socketed,in any length with rubber ring joints,fixed in wall complete all as specified and directed. |
| 26 | S&F in repairs 110 mm bore PVC (SWR) pipes single socketed,in any length with rubber ring joints,fixed in wall complete all as specified and directed. |
| 27 | S&F in repairs 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed. |
| 28 | S&F in repairs 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed. |
| 29 | S&F in repairs 75 mm bore PVC (SWR) branch piece,single (double Y) equal or unequal bends of any radius,fixed with cement solvent with oval access door complete all as specified and directed. |
| 30 | S&F in repairs 100 mm bore PVC (SWR) branch piece,single (double Y) equal or unequal bends of any radius,fixed with cement solvent with oval access door complete all as specified and directed. |
| 31 | S&F in repairs 75 mm bore PVC (SWR) junction,single (single T) equal or unequal bends of any radius,fixed with cement solvent with oval access door complete all as specified and directed. |
| 32 | S&F in repairs 110 mm bore PVC (SWR) junction,single (single T) equal or unequal bends of any radius,fixed with cement solvent with oval access door complete all as specified and directed. |
| 33 | Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance. Please Enable Macros to View BoQ information |