| Sl. No. | Item Description |
| 1 | Recessed PVC Conduit Wiring with Modular accessories |
| 2 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. |
| 3 | Short point (up to 3 mtr.) |
| 4 | Medium point (up to 6 mtr.) |
| 5 | Long point (up to 10 mtr.) |
| 6 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal,2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required. |
| 7 | Short point (up to 3 mtr.) |
| 8 | Medium point (up to 6 mtr.) |
| 9 | Long point (up to 10 mtr.) |
| 10 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. |
| 11 | On board |
| 12 | Short point (up to 3 mtr.) |
| 13 | Medium point (up to 6 mtr.) |
| 14 | Long point (up to 10 mtr..) |
| 15 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required. |
| 16 | 20 mm |
| 17 | 25 mm |
| 18 | 32 mm |
| 19 | Recessed PVC Conduit Wiring with Non Modular accessories |
| 20 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 1.2 mm thick Hot dipped Galavanized MS box with earth terminal, 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 21 | Short point (up to 3 mtr.) |
| 22 | Medium point (up to 6 mtr.) |
| 23 | Long point (up to 10 mtr.) |
| 24 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos 1.2 mm thick Hot dipped Galavanized MS box with earth terminal, 2 Nos 6 A two way switch,3 pin ceiling rose / holder/ 3 way connector, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 25 | Short point (up to 3 mtr.) |
| 26 | Medium point (up to 6 mtr.) |
| 27 | Long point (up to 10 mtr..) |
| 28 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, 1.2 mm thick Hot dipped Galavanized MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 29 | On board |
| 30 | S&F of following sizes of polypropelene corrugated flexible conduit including gland on both side of flexible conduit as required. |
| 31 | 16 mm OD |
| 32 | 20 mm OD |
| 33 | 25 mm OD |
| 34 | Surface PVC Conduit Wiring with Modular accessories |
| 35 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal/Surface mounted UPVC molded modular box, 6 A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. |
| 36 | Short point (up to 3 mtr.) |
| 37 | Medium point (up to 6 mtr.) |
| 38 | Long point (up to 10 mtr.) |
| 39 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, 2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required. |
| 40 | Short point (up to 3 mtr.) |
| 41 | Medium point (up to 6 mtr.) |
| 42 | Long point (up to 10 mtr.) |
| 43 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. |
| 44 | On board |
| 45 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required on surface including heavy duty saddles with base at spacing of 0.60 mtr. etc as required. |
| 46 | 20 mm |
| 47 | 25 mm |
| 48 | Surface PVC Conduit Wiring with Non Modular accessories |
| 49 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size , 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 50 | Short point (up to 3 mtr.) |
| 51 | Medium point (up to 6 mtr.) |
| 52 | Long point (up to 10 mtr.) |
| 53 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size, 2 Nos 6 A two way switch,3 pin ceiling rose / holder/ 3 way connector, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 54 | Short point (up to 3 mtr.) |
| 55 | Medium point (up to 6 mtr.) |
| 56 | Long point (up to 10 mtr..) |
| 57 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 58 | On board |
| 59 | Short point (up to 3 mtr.) |
| 60 | Medium point (up to 6 mtr.) |
| 61 | Long point (up to 10 mtr..) |
| 62 | Surface Wiring in uPVC Trunking with Modular accessories |
| 63 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS:14927 P - II ) uPVC trunking & it's accessories, Hot Dipped Galvanized Modular box 1.2 mm thick with earth terminal/ Surface mounted UPVC molded modular box, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose/holder /3 way Connector, screws, making connections, testing etc. as required. |
| 64 | Short point (up to 3 mtr.) |
| 65 | Medium point (up to 6 mtr.) |
| 66 | Long point (up to 10 mtr.) |
| 67 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) of approved make on surface ISI marked ( IS:14927 P - II ) uPVC trunking & it's accessories, 2 No. Hot Dipped Galvanized Modular box 1.2 mm thick with earth terminal/ 2 No. Surface mounted UPVC molded modular box, 2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder/3 way Connector , Modular face plate with grid plate, screws, making connections, testing etc. as required |
| 68 | Short point (up to 3 mtr.) |
| 69 | Medium point (up to 6 mtr.) |
| 70 | Long point (up to 10 mtr..) |
| 71 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked ( IS:14927 P - II ) uPVC trunking & it's accessories, Hot Dipped Galvanized Modular box 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, modular 6 A switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required |
| 72 | On board |
| 73 | S&F following sizes of ISI marked ( IS:14927 P - II ) uPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners etc. as required. |
| 74 | 20 mm x 12 mm |
| 75 | 25 mm x 12 mm |
| 76 | 32 mm x 12 mm |
| 77 | 25 mm x 16 mm |
| 78 | 38 mm x 16 mm |
| 79 | Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. |
| 80 | 1 x 1.5 sq.mm |
| 81 | 2 x 1.5 sq.mm |
| 82 | 3x 1.5 sq.mm |
| 83 | 4 x 1.5 sq.mm |
| 84 | 1 x 2.5 sq.mm |
| 85 | 2 x 2.5 sq.mm |
| 86 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 87 | 3 x 2.5 sq.mm |
| 88 | 4 x 2.5 sq.mm |
| 89 | 1 x 4.0 sq.mm |
| 90 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 91 | 1 x 6.0 sq.mm |
| 92 | 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. |
| 93 | 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. |
| 94 | 1 x 10.0 sq.mm |
| 95 | Supply and Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required. |
| 96 | 1.5 Sq.mm 3 core flat / Round |
| 97 | 2.5 Sq.mm 3 core flat / Round |
| 98 | P & F 1.2 mm thick Hot dipped galvanized boxes with brass earthing terminal of following sizes (nominal size) in recessed/surface as required. |
| 99 | 75mm x 75mm x 60mm |
| 100 | 100mm x 100mm x 60mm |
| 101 | 150mm x 75mm x 60mm |
| 102 | 175mm x 100mm x 60mm |
| 103 | 150mm x 150mm x 60mm |
| 104 | 225mm x 100mm x 60mm |
| 105 | 200mm x 150mm x 60mm |
| 106 | 200mm x 125mm x 75mm |
| 107 | 200mm x 250mm x 75mm |
| 108 | 200mm x 250mm x 100mm |
| 109 | 250mm x 300mm x 75mm |
| 110 | 250mm x 300mm x 100mm |
| 111 | 300mm x 375mm x 75mm |
| 112 | 300mm x 375mm x 100mm |
| 113 | 250mm x 100mm x 60mm |
| 114 | 300mm x 100mm x 60mm |
| 115 | 300mm x 300mm x 75mm |
| 116 | P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required. |
| 117 | 25mm x 25mm x 3mm |
| 118 | 25mm x 25mm x 5mm |
| 119 | 35mm x 35mm x 5mm |
| 120 | 40mm x 40mm x 5mm |
| 121 | 50mm x 50mm x 6mm |
| 122 | P & Fixing Powder coated CRCA sheet enclosures on existing Structure by means of nuts and bolts and making holes , Din rail etc. as required. |
| 123 | 1.2 mm thick |
| 124 | 1.6 mm thick |
| 125 | 2.0 mm thick |
| 126 | 2.5 mm thick |
| 127 | P & Fixing M.S. flat on existing angle iron frame and making required nos. of holes for fixing accessories including one coat of red oxide paint and two coats of enamel paint etc. as required. |
| 128 | 25 mm x 3 mm |
| 129 | 25 mm x 5 mm |
| 130 | 32 mm x 5 mm |
| 131 | 40 mm x 6 mm |
| 132 | 50 mm x 6 mm |
| 133 | P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. |
| 134 | 3.0 mm thick |
| 135 | 5.0 mm thick |
| 136 | 6.0 mm thick |
| 137 | 8.0 mm thick |
| 138 | 10.0 mm thick |
| 139 | 16.0 mm thick |
| 140 | 20.0 mm thick |
| 141 | P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required. |
| 142 | 75 mm dia |
| 143 | 100 mm dia. |
| 144 | P & F P.V.C. sheet 2.0 mm thick of following size Including screws, cup washer as required. |
| 145 | 75 mm dia. |
| 146 | 100 mm dia. |
| 147 | P & F Aluminium sheet 1.0 m thick of following size dia. Including screws, cup washer as required. |
| 148 | 75 mm dia. |
| 149 | 100 mm dia. |
| 150 | P & F 1.2 mm thick M.S. Recessed concealed box, round of size 150 mm dia, depth 100 mm complete as required. |
| 151 | Labour charges for dismantling of surface PVC/ Steel conduit including wiring in conduit, conduit fittings and depositing the same with listing of material in store. |
| 152 | Labour charges for dismantling of surface/ recessed switch board of any size and depositing the same with listing of material in store. |
| 153 | Labour charges for dismantling of switch accessories like switch, socket, ceiling rose, holder and depositing the same with listing of material in store. |
| 154 | Labour charges for dismantling of wiring in existing conduit of following size and depositing the same with listing of material in store. |
| 155 | up to 2.5 sq. mm. wire |
| 156 | 4/ 6 sq. mm. wire |
| 157 | 10 sq. mm. wire |
| 158 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. |
| 159 | Single pole MCB (With B / C curve tripping characteristics) |
| 160 | 0.5 A to 5 A rating |
| 161 | 6 A to 32 A rating |
| 162 | 40 A rating |
| 163 | 50/63 A rating |
| 164 | Double pole MCB (With B / C curve tripping characteristics) |
| 165 | 0.5 A to 5 A rating |
| 166 | 6 A to 32 A rating |
| 167 | 40 A rating |
| 168 | 50/63 A rating |
| 169 | Triple pole MCB (With B / C curve tripping characteristics) |
| 170 | 0.5A to 5 A rating |
| 171 | 6 A to 32 A rating |
| 172 | 40 A rating |
| 173 | 50/63 A rating |
| 174 | Four pole MCB (With B / C curve tripping characteristics) |
| 175 | 0.5A to 5 A rating |
| 176 | 6 A to 32 A rating |
| 177 | 40 A rating |
| 178 | 50/63 A rating |
| 179 | Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 25 sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. |
| 180 | Two pole 30 mA sensitivity |
| 181 | 6A-32 A rating |
| 182 | 40 A rating |
| 183 | 63 A rating |
| 184 | Two pole 100/300mA sensitivity |
| 185 | 6A-32 A rating |
| 186 | 40 A rating |
| 187 | 63 A rating |
| 188 | Four pole 30 mA sensitivity |
| 189 | 6A-32 A rating |
| 190 | 40 A rating |
| 191 | 63 A rating |
| 192 | Four pole 100/300 mA sensitivity |
| 193 | 6A-32 A rating |
| 194 | 40 A rating |
| 195 | 63 A rating |
| 196 | Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating and 5000 for 100 A rating and minimum phase termination capacity of 25 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. |
| 197 | Two pole 30 mA sensitivity |
| 198 | 16/25 A rating |
| 199 | 32/40 A rating |
| 200 | 63A rating |
| 201 | 100 A rating |
| 202 | Two pole 100/300mA sensitivity |
| 203 | 16/25 A rating |
| 204 | 40 A rating |
| 205 | 63 A rating |
| 206 | Four pole 30 mA sensitivity |
| 207 | 25 A rating |
| 208 | 40 A rating |
| 209 | 63 A rating |
| 210 | 100 A rating |
| 211 | Four pole 100/300 mA sensitivity |
| 212 | 25 A rating |
| 213 | 40 A rating |
| 214 | 63 A rating |
| 215 | 100 A rating |
| 216 | Providing & Fixing of Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. complete with din rail making internal DB terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required. |
| 217 | Suitable for Two / Three / Four module for MCB |
| 218 | Suitable for Six / Eight module for MCB/ RCCB |
| 219 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed / Acrylic) Distribution board with Metal end box made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, complete with 100 amp. insulated copper bus bar/shorting link , brass neutral link with shrouds, brass earth link , door earthing arrangement, color coded interconnecting wire set of minimum 10.0 sqmm size and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. |
| 220 | Metal door (single phase) IK-09 and IP-43 with Metal end box |
| 221 | 4 Way |
| 222 | 6 Way |
| 223 | 8 Way |
| 224 | 12 Way |
| 225 | 16 Way |
| 226 | Metal door (Three phase) IK-09 and IP-43 with Metal end box |
| 227 | 4 Way (8 incomer + 12 Outgoing) |
| 228 | 6 Way (8 incomer + 18 Outgoing) |
| 229 | 8 Way (8 incomer + 24 Outgoing) |
| 230 | 12 Way (8 incomer + 36 Outgoing) |
| 231 | P&F metal clad / Polyamide industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. (without MCB) including making connections, testing etc.as required. |
| 232 | 20 amp, (2P + E), 1 Module |
| 233 | 20 amp, (2P + E), 2 Module |
| 234 | 20 amp, (2P + E), 3 Module |
| 235 | 32 amp, (3P + E), 3 Module |
| 236 | P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. |
| 237 | IP -67, IK - 09 Panel mounted socket |
| 238 | 16 A (2P+E) |
| 239 | 32 A (2P+E) |
| 240 | 32 A (3P+N+E) |
| 241 | 63 A (3P+N+E) |
| 242 | IP -67, IK-09 Surface/Wall mounted socket |
| 243 | 16 A (2P+E) |
| 244 | 32 A (2P+E) |
| 245 | 32 A (3P+N+E) |
| 246 | 63 A (3P+N+E) |
| 247 | IP -66, Surface/Wall mounted Interlocked switched socket Outlet with Provision of MCB |
| 248 | 16 A (2P+E) 250 V |
| 249 | 32 A (2P+E), 250 V |
| 250 | 32 A (3P+E), 415 V |
| 251 | 32 A (3P+N +E), 415 V |
| 252 | 63 A (3P+N +E), 415 V |
| 253 | IP - 67 Plug top |
| 254 | 16 A (2P+E) |
| 255 | 32 A (2P+E) |
| 256 | 32 A (3P+E) |
| 257 | 32 A (3P+N+E) |
| 258 | 63 A (3P+N+E) |
| 259 | Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for MCB / RCCB/ RCBO up to 63 Amp and SP / TP MCB upto 32 Amp. as outgoing ,made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3 complete with insulated 100 A rating copper bus bar, brass neutral bars with shrouds, brass earth bar , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. |
| 260 | Double door IK-09 & IP-43 with Metal end box |
| 261 | 4 Way (8 Incomer +12 Outgoing) |
| 262 | 6 Way (8 Incomer +18 Outgoing) |
| 263 | 8 Way (8 Incomer +24 Outgoing) |
| 264 | 12 Way (8 Incomer + 36 Outgoing) |
| 265 | Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB up to 63 Amps. as outgoing ,made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. complete with insulated 125/160/200/250 Amp. copper bus bar, brass neutral bars with shrouds, brass earth bar , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. |
| 266 | Double door IP-43 & IK-09 with Provision of Incomer MCCB up to 125 A Rating with Metal end box |
| 267 | 4 Way |
| 268 | 6 Way |
| 269 | 8 Way |
| 270 | 12 Way |
| 271 | Double door IP-43 & IK-09 with Provision of Incomer MCCB 160 A Rating with Metal End Box |
| 272 | 4 Way |
| 273 | 6 Way |
| 274 | 8 Way |
| 275 | 12 Way |
| 276 | Double door IP-43 & IK-09 with Provision of Incomer MCCB 200/250 A Rating with metal End Box |
| 277 | 4 Way |
| 278 | 6 Way |
| 279 | 8 Way |
| 280 | 12 Way |
| 281 | P & F Surface mounting IP-65, IK-09 Class-II self extinguishing insulating material weather proof cabinets confirming to EN60439-3 with IP-65 Key lock, fully reversible door and cabinet, removable chasis and face plates, of following size. |
| 282 | 3/4 module |
| 283 | 6 module |
| 284 | 8 module |
| 285 | 1 row 12 module |
| 286 | 2 row 24 module |
| 287 | 3 row 36 module |
| 288 | P & F ISI marked (IS:3854) 6 amp. flush type non modular switch with CM/L no. printed and made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. |
| 289 | P & F ISI marked (IS :3854) 16 amp. flush type non modular switch CM/L no. printed and made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. |
| 290 | Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. |
| 291 | Providing & Fixing of 16 amp. Combined flush type non modular socket and switch set with indicator and fuse set, made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. |
| 292 | Providing & Fixing of ISI marked (IS :3854) non modular 6A bell push surface type CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required. |
| 293 | Providing & Fixing of ISI marked (IS :3854) twin control non modular 6A switch surface type, CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required. |
| 294 | Providing & Fixing of ISI marked (IS :3854) non modular 6A bell push flush type CM/L no. printed and made out from industrial grade Polycarbonate materialincluding cutting hole in tile and making connection testing etc. as required. |
| 295 | Providing & Fixing of ISI marked (IS :3854) twin control non modular 6A switch flush type CM/L no. printed , made out from industrial grade Polycarbonate material, including cutting hole in tile and making connection testing etc. as required. |
| 296 | Providing & Fixing of non modular 6A hanging bell push/one way switch made out from industrial grade Polycarbonate material including making connection testing etc. as required. |
| 297 | Providing & Fixing of IS:1293 marked of 3 pin 6 amp. flush type non modular socket CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. |
| 298 | Providing & Fixing of IS:1293 3/6 pin 16 amp flush type non modular socket CM/L no. printed and made out from Industrial grade Polycarbonate material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. |
| 299 | Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required. |
| 300 | Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required. |
| 301 | Providing & Fixing of ISI marked (IS:1293) 6 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required. |
| 302 | Providing & Fixing of ISI marked (IS:1293) 16 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required. |
| 303 | Providing & Fixing of flush type non modular 2 pin telephone socket with plug top made out from industrial grade Polycarbonate material, brass terminals including making connection testing etc. as required. |
| 304 | Providing & Fixing of flush type non modular single line telephone jack made out from industrial grade Polycarbonate material, including making connection testing etc. as required. |
| 305 | Providing & Fixing of flush type non modular double line telephone jack made out from industrial grade Polycarbonate materialincluding making connection testing etc. as required. |
| 306 | Providing & Fixing of flush type non modular coaxial T.V. socket made out from industrial grade Polycarbonate material,including making connection testing etc. as required. |
| 307 | Providing & Fixing of IS 11037 marked non modular socket size flush type 100 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required. |
| 308 | P & F ISI marked 32 A D.P. switch with fuse and indicating lamp including making connection testing etc. as required. |
| 309 | Providing & Fixing of ISI marked (IS:302) gong bell with CM/L no. printed including making connection testing etc. as required. |
| 310 | Providing & Fixing of Non Modular Neon Light including making connection testing etc. as required. |
| 311 | Providing & Fixing of single / multi tone electronic call bell / remote bell including making connection testing etc. as required. |
| 312 | Providing & Fixing of ISI marked (IS:302) ding dong/musical chime bell including making connection testing etc. as required. |
| 313 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant virgin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including making connections, testing etc as required. |
| 314 | 6 A one way switch |
| 315 | 6 A two way switch |
| 316 | 6 A bell push |
| 317 | 10 A one way switch |
| 318 | 10 A two way switch |
| 319 | 16 A one way switch 1M |
| 320 | 20 A one way switch 1M |
| 321 | 20 A one way switch 2M |
| 322 | 16 Amp. 2 Module switch With Led Indicator |
| 323 | 32 Amp. 2 Module switch With Led Indicator |
| 324 | Providing & Fixing of IS:1293 marked modular type lockable feature socket with CM/L no. printed duly made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required. |
| 325 | 6 A 3 pin shuttered socket |
| 326 | 6/16 A shuttered socket |
| 327 | Providing & Fixing of modular type 100W Step Fan regulator duly ISI marked (IS 11037) with CM/L no. printed made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including making connections, testing etc as required. |
| 328 | 5 step fan regulator 2 Module |
| 329 | Providing & Fixing of following modular accessories, made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required. |
| 330 | Blanking plate |
| 331 | 25 Amp. 2 Module Motor Starter with on / off Push button |
| 332 | LED Skirting /Foot Light 2 Module |
| 333 | Electronic Chime/Buzzer 2M |
| 334 | Modular MCB 6 A to 32 A SP |
| 335 | Modular MCB 6 A to 32 A DP |
| 336 | Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. |
| 337 | 1/2 Module |
| 338 | 3 Module |
| 339 | 4 Module |
| 340 | 5 Module |
| 341 | 6 Module |
| 342 | 8 Module |
| 343 | 10 Module |
| 344 | 12 Module |
| 345 | 16/18 Module |
| 346 | Providing & Fixing of following size cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. |
| 347 | 1/2 Module |
| 348 | 3 Module |
| 349 | 4 Module |
| 350 | 5 Module |
| 351 | 6 Module |
| 352 | 8 Module |
| 353 | 10 Module |
| 354 | 12 Module |
| 355 | 16/18 Module |
| 356 | Providing & Fixing of Hot dipped Galvanized metal box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required. |
| 357 | 1-2 Module |
| 358 | 3 Module |
| 359 | 4-5 Module |
| 360 | 6-8 Module |
| 361 | 10-12 Module |
| 362 | 16/18 Module |
| 363 | Providing & Fixing of Wiring Accessories OEM fabricated following size virgin material UPVC modular boxes on surface suitable for modular accessories as required. |
| 364 | 1-2 Module |
| 365 | 3 Module |
| 366 | 4/5 Module |
| 367 | 6 / 8 module |
| 368 | 10 / 12 module |
| 369 | 16/18 module |
| 370 | Providing & Fixing of DLP PVC adaptable trunking system for cable management including finishing accessories like corners, tees, adjustable angles, junction etc. as required . The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. OEM have to submit NABL accrediated /CPET lab test reports /EN 50085-2-1 complaince certificate. |
| 371 | 80mm x 50mm |
| 372 | 100/105mm x 50mm |
| 373 | 150/160mm x 50mm |
| 374 | 195/200mm x 50mm |
| 375 | Providing and fixing of power plug point with non modular accessories with Galvanized box of 1.2 mm thick with earth terminal with suitable size 3.0 mm thick phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required. |
| 376 | Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. |
| 377 | P & F Krone module with base frame in the recess / surface made out of 1.2 mm thick sheet steel box, front openable, having locking arrangements duly powder coated ,including dressing, ferruling and punching of telephone cable with krone tool etc. as required. |
| 378 | 10 Pairs |
| 379 | 20 Pairs |
| 380 | 50 Pairs |
| 381 | 100 Pairs |
| 382 | 200 Pairs |
| 383 | P & F Portable Residual Current Device (PRCD) 3 pin plug top 16 A, 30 mA sensitivity. Plug should have feature of power indicator, test button and reset function etc. as required. |
| 384 | SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- |
| 385 | (a) Thickness of CRCA sheet shall not be less than 1.6 mm upto 450 mm length/ width of any compartment and be 2.0 mm above 450 mm, load bearing structure shall be 2.0 mm thick sheet supported by base M.S. channel if required, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided |
| 386 | (b) complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side(Inner & Outer side) of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. |
| 387 | [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra ) |
| 388 | (d) Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. |
| 389 | (e) All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. |
| 390 | (f) Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra ) |
| 391 | (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. |
| 392 | (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI type Test certificates for Temp. rise test, Short circuit test for 50 kA and IP test is to be submitted) |
| 393 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator, with short circuit withstand capacity of 31 MVA for 1 Sec. , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. |
| 394 | Electrolytic grade Aluminium bus bar 6010 grade |
| 395 | Electrolytic grade (Cu+ETP) Tin Coated annealed copper bus bars IACS 100% grade. |
| 396 | Providing & Fixing of IS: 1248(part-1) 2003 confirming Moving Iron panel meter, 90 degree Analog type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter of class 1.0 accuracy of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. |
| 397 | Voltmeter ( 0 to 500V ) |
| 398 | Ammeter (Direct Reading / CT Operated) |
| 399 | Providing & Fixing of IS: 13875 & IEC :61326/IEC:62053-22 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT opertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. |
| 400 | Single Phase Ammeter |
| 401 | Single Phase Voltmeter |
| 402 | Three phase Ammeter with Inbuilt Selector Switch |
| 403 | Three phase Voltmeter with Inbuilt Selector Switch |
| 404 | Providing & Fixing of Current Transformer confirming IS 2705-I (1992) with secondary terminal and shorting Block , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . |
| 405 | Ring type tape wound CT |
| 406 | C T Class 1, Ratio up to 150/5, Burden 5 VA |
| 407 | Resin cast wound type CT |
| 408 | C T Class 1, Ratio up to 150/5, Burden 5 VA |
| 409 | Providing & Fixing of selector switch of 10 A for voltmeter using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. Switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . |
| 410 | Voltage Between Phases with OFF ( 4 Position ) |
| 411 | Voltage Between Phases & Individual Phases to Neutral with OFF ( 7 Position ) |
| 412 | Providing & Fixing of CT linked selector switch of 10 A for Ampere meter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc. as required . |
| 413 | Providing & Fixing of 10 A Cam operated rotary (Local- Remote, Auto - manual) switches on existing panel with 1 pole 2 way and off position using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . |
| 414 | Providing & Fixing of 25 A TNC ( Trip - neutal - close ) switch to control remotely on existing panel as required. |
| 415 | Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 27 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. |
| 416 | Red/yellow/Green colour |
| 417 | Blue / white Colour |
| 418 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle ( to be paid extra) , including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate. |
| 419 | 3 pole MCCB With Thermal Magnetic release |
| 420 | up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting |
| 421 | up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 422 | 125 Amp , 25 kA, adjustable O/L & fixed S/C setting, |
| 423 | 160 Amp , 25 kA, adjustable O/L & fixed S/C setting, |
| 424 | 4 pole MCCB With Thermal Magnetic release |
| 425 | up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting |
| 426 | up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 427 | 125 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 428 | 160 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 429 | 200 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 430 | 250 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 431 | 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, |
| 432 | 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting, |
| 433 | 630 Amp , 50 kA, adjustable O/L & adjustable S/C setting, |
| 434 | 800 Amp , 50 kA, adjustable O/L & adjustable S/C setting, |
| 435 | Supply and fixing of following accessories for Moulded case circuit breaker (MCCB) compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. |
| 436 | Spreaders upto 125A, 3 Pole MCCB |
| 437 | Spreaders for 160A, 3 Pole MCCB |
| 438 | Spreaders for 160A, 4 Pole MCCB |
| 439 | Spreaders for 250A, 3 Pole MCCB |
| 440 | Spreaders for 250A, 4 Pole MCCB |
| 441 | Spreaders for 400A, 3Pole MCCB |
| 442 | Spreaders for 400A, 4Pole MCCB |
| 443 | Spreaders for 630A, 3Pole MCCB |
| 444 | Spreaders for 630A, 4Pole MCCB |
| 445 | Spreaders for 800A, 3Pole MCCB |
| 446 | Spreaders for 800A, 4Pole MCCB |
| 447 | Providing & Laying XLPE insulated & P.V.C. sheathed Un-Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing commissioning etc. as required of following size. |
| 448 | 4.0 Sq. mm |
| 449 | 2 core |
| 450 | 3 core |
| 451 | 4 core |
| 452 | 6.0 Sq. mm |
| 453 | 2 core |
| 454 | 3 core |
| 455 | 4 core |
| 456 | 10.0 Sq. mm |
| 457 | 2 core |
| 458 | 3 core |
| 459 | 4 core |
| 460 | 16.0 Sq. mm |
| 461 | 2 core |
| 462 | 3 core |
| 463 | 4 core |
| 464 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size. |
| 465 | 4.0 Sq. mm |
| 466 | 2 core |
| 467 | 3 core |
| 468 | 4 core |
| 469 | 6.0 Sq. mm |
| 470 | 2 core |
| 471 | 3 core |
| 472 | 4 core |
| 473 | 10.0 Sq. mm |
| 474 | 2 core |
| 475 | 3 core |
| 476 | 4 core |
| 477 | 16.0 Sq. mm |
| 478 | 2 core |
| 479 | 3 core |
| 480 | 4 core |
| 481 | 25.0 Sq. mm |
| 482 | 2 core |
| 483 | 3 core |
| 484 | 3.5 core |
| 485 | 35.0 Sq. mm |
| 486 | 2 core |
| 487 | 3 core |
| 488 | 3.5 core |
| 489 | 50.0 Sq. mm |
| 490 | 2 core |
| 491 | 3 core |
| 492 | 3.5 core |
| 493 | 70.0 Sq. mm |
| 494 | 1 core |
| 495 | 2 core |
| 496 | 3 core |
| 497 | 3.5 core |
| 498 | Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. |
| 499 | Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. |
| 500 | Providing & Fixing of BEE Star rated copper wounded with class of Insulation 'F', double ball bearing capacitor start, aluminium body & aluminium blade ceiling fan conforming to all the performance requirements laid down in IS 374:2019 with down rod up to 30 cm with secondary support safety cable ( steel rope) , cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor and making connection testing etc. as required. |
| 501 | 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) |
| 502 | Providing & Fixing of shackle (iron hook) made from 2mm nominal thick CRCA sheet and bolts (2nos) of 6mm with spring washer nut, checknut & split pin as required. |
| 503 | Providing & Fixing of of M.S. J- hook of standard design made out of 16 mm dia. M.S. round bar and fixed with cement concrete mortar with required support as required. |
| 504 | P & F 1.2 mm thick M.S. Recessed fan box and top lid screwed on Box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 150 mm length extended on each side as required. |
| 505 | Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core 1.5 Sq.mm copper conductor ,making connections, testing etc. as required. |
| 506 | 230 mm sweep, Minimum air delivery 750 Cum / hour |
| 507 | 300 mm sweep Minimum air delivery 1600 Cum / hour |
| 508 | Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 marked in existing opening including making connections testing etc. as required. |
| 509 | 300 mm sweep(900 RPM) |
| 510 | Providing & Fixing of ventilating fans Capacitor start, copper wounded, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. |
| 511 | 150 mm sweep Minimum Air Delivery 150 Cum / hour |
| 512 | 200 mm sweep Minimum Air Delivery 450 Cum / hour |
| 513 | 250 mm sweep Minimum Air Delivery 750 Cum / hour |
| 514 | Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap action adjustable thermostat , Dual indicating lamps Injected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top , including making inlet, outlet Flexible alloy connection, testing etc. as required. |
| 515 | 6 Ltr. |
| 516 | 10 Ltr. |
| 517 | 15 Ltr. |
| 518 | SITC of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output only at CW (5700K to 6500K) , internal surge protection of 4.0 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 519 | 1170mm(+/-10%) LED batten with min. lumen output 2200 lm |
| 520 | SITC of IP-20 LED Recessed / Surface Mounted, Round / Square backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS compliance 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 521 | Recessed Mounting |
| 522 | Minimum lumen output 600 lm (lumen efficacy ≥ 100 lm / watt) |
| 523 | Minimum lumen output 1300 lm |
| 524 | Minimum lumen output 1600 lm |
| 525 | Minimum lumen output 1950 lm |
| 526 | Minimum lumen output 2400 lm |
| 527 | Surface Mounting (with extruded alumn. Housing ) |
| 528 | Minimum lumen output 600 lm (lumen efficacy ≥ 100 lm / watt) |
| 529 | Minimum lumen output 1300 lm |
| 530 | Minimum lumen output 1600 lm |
| 531 | Minimum lumen output 1950 lm |
| 532 | Minimum lumen output 2400 lm |
| 533 | SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmissivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V . High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection ( input 320VAC-48 hoursprotection,input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 534 | Recessed Mounting |
| 535 | Minimum lumen output 4320 lm |
| 536 | Surface Mounting (Driver should be Inside the Luminaire) |
| 537 | Minimum lumen output 4320 lm |
| 538 | SITC of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 539 | 9 Watt |
| 540 | 18/20 Watt |
| 541 | Providing & Fixing of IK07 IP65 protected Top/Bottom mounted LED Post top Luminarie top & bottom made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with powder quoted reflector. The System level Luminous efficacy ≥ 80 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . LED Driving output current <750mA as required. |
| 542 | Minimum lumen output 2800 lm Post top Luminarie |
| 543 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass with suitable lenses on LED / integrated lens diffuser to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated metal case potted driver as a unique BIS R number (as per IS 15885) having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate(Fitting & driver both have separate BIS R number). The System level Luminaire efficacy >=130 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , LED driving output current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K as required. |
| 544 | High Power LED Flood Light Minimum lumen outpu 3900 lm |
| 545 | High Power LED Flood Light Minimum lumen output 6500 lm |
| 546 | High Power LED Flood Light Minimum lumen output 10400 lm |
| 547 | High Power LED Flood Light Minimum lumen output 13000 lm |
| 548 | High Power LED Flood Light Minimum lumen output 15600 lm |
| 549 | High Power LED Flood Light Minimum lumen output 19500 lm |
| 550 | High Power LED Flood Light Minimum lumen output 23400 lm |
| 551 | High Power LED Flood Light Minimum lumen output 26000lm |
| 552 | High Power LED Flood Light Minimum lumen output 32500 lm |
| 553 | High Power LED Flood Light Minimum lumen output 39000 lm |
| 554 | High Power LED Flood Light Minimum lumen output 45500 lm |
| 555 | High Power LED Flood Light Minimum lumen output 52000 lm |
| 556 | High Power LED Flood Light Minimum lumen output 65000 lm |
| 557 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing and secondary lens on each LED/ integrated lens diffuser without cover & should be High power LED of 3 to 5 watt each . The System efficacy >=135 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current <750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required. |
| 558 | LED Street Light fixture with Minimum lumen output 2700 lm |
| 559 | LED Street Light fixture with Minimum lumen output 4050 lm |
| 560 | LED Street Light fixture with Minimum lumen output 6075 lm |
| 561 | LED Street Light fixture with Minimum lumen output 8100 lm |
| 562 | LED Street Light fixture with Minimum lumen output 9450 lm |
| 563 | LED Street Light fixture with Minimum lumen output 12150 lm |
| 564 | LED Street Light fixture with Minimum lumen output 13500 lm |
| 565 | LED Street Light fixture with Minimum lumen output 16200 lm |
| 566 | LED Street Light fixture with Minimum lumen output 20250 lm |
| 567 | LED Street Light fixture with Minimum lumen output 24300 lm |
| 568 | LED Street Light fixture with Minimum lumen output 28350 lm |
| 569 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED/ integrated lens diffuser & should be High power LED of 3 to 5 watt each . The System efficacy >=125 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current <750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required. |
| 570 | LED Street Light fixture with Minimum lumen output 2500 lm |
| 571 | LED Street Light fixture with Minimum lumen output 3750 lm |
| 572 | LED Street Light fixture with Minimum lumen output 5625 lm |
| 573 | LED Street Light fixture with Minimum lumen output 7500 lm |
| 574 | LED Street Light fixture with Minimum lumen output 8750 lm |
| 575 | LED Street Light fixture with Minimum lumen output 11250 lm |
| 576 | LED Street Light fixture with Minimum lumen output 12500 lm |
| 577 | LED Street Light fixture with Minimum lumen output 15000 lm |
| 578 | LED Street Light fixture with Minimum lumen output 18750 lm |
| 579 | LED Street Light fixture with Minimum lumen output 22500 lm |
| 580 | LED Street Light fixture with Minimum lumen output 26250 lm |
| 581 | Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window, PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0 sq.mm heavy duty connector, earth terminal, complete in all respect. |
| 582 | 125 mm X 200 mm X 122 mm |
| 583 | Replacement of Existing Battery with 12V VRLA Lead Acid Sealed maintenance free (SMF) batteries of following capacity with Warranty of 2 years (The old battery shall be retained by contractor) |
| 584 | 12V 7 AH |
| 585 | 12V 9 AH |
| 586 | SITC of Monoblock closed coupled motor pump set with TEFC motor, motor should be IP55-F class and IE2 efficiency for monobloc, with carbon steel /SS-410 shaft, Mechanical seal, Single/Three phase Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively and Dynamically balanced rotating parts to ensure min. vibration etc. complete in all respect. |
| 587 | 0.5 HP, 1-Ø, (8 - 26)Mtr, (50-10) LPM (SS Impellor & SS Body) |
| 588 | 1.0 HP, 1-Ø, (10-30)Mtr, (76-28) LPM ( Bronze impeller & Aluminium Body) |
| 589 | 1.0 HP, 1-Ø, (10-30)Mtr, (76-28) LPM ( Bronze impeller & CI Body) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail