Educational and Research Institute Boards / Undertakings / PSU Closing in 2 days TDR #56060170

Tender For Vertical Extension Of Slet Commission Building (Second Floor, Third & Fourth Floor & Remaining Few Finishing Works Of First Floor) At Jalukbari Guwahati Assam

Issued by Boards / Undertakings / PSU · Kamrup Metro, Assam
Tender Value
3.77 Crore
Estimated cost
Bid Submission
13 Jul 2026
2 days left
EMD
7.54 Lakhs
Bank guarantee accepted
Document Fee
8000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Vertical Extension Of Slet Commission Building (Second Floor, Third & Fourth Floor & Remaining Few Finishing Works Of First Floor) At Jalukbari Guwahati Assam

BOQ

Name of Work:- Vertical extension of SLET Commission Building (Second floor, Third & Fourth Floor & Remaining few finishing works of First Floor) at Jalukbari Guwahati Assam
Sl. No. Item Description
1Civil Works , Sanitary & water supply works, Fire fighting worksand Electrical works
2FLAT BRICK SOILING WORK :Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
3PLAIN CEMENT CONCRETE WORKSProviding and laying cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns, piers,abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering,shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) derived from naturalsources : 6 graded stone aggregate 20 mm nominal sizederived from natural sources)
4REINFORCED CEMENT CONCRETE WORKSProviding and laying in position ready mixed or site batched design mixcement concrete for reinforced cement concrete work; using coarseaggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /PortIand Slag cement, admixtures inrecommended proportions as per IS: 9103 toaccelerate/ retard settingof concrete, to improve durability and workability without impairingstrength; including pumping ofconcrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, forthe following grades of concrete.:Note: Extra cement up to 10% oftheminimum specified cement contentin design mix shall be payable separately. In case the cement content indesign mix is more than 110% ofthespecified minimum cement content,the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floorV levelConcrete of M25 grade with minimum cementcontent of 350 kg /cum
5FORMWORKCentering & shuttering including strutting, propping etc. and removal of form work for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
6Suspended floors, roofs, landings, balconies and access
7Lintels, beams, plinth beams, girders, bressumers andcantilevers
8Columns, Pillars, Piers, Abutments, Posts and Struts
9Stairs, (excluding landings) except spiral-staircases
10STEEL AND IRON WORKS Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
11MASONRY WORKSProviding and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floorV level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made forseperately).
12PLASTERING WORKSCEMENT PLASTER (IN FINE SAND)12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
1315 mm cement plaster: 1:4 (1 cement : 4 fine sand)
14PAINTING WORKSINTERIOR FINISHINGFinishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
15EXTERIOR FINISHINGProviding and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
16Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
17Applying priming coat: STEEL & WOODEN SURFACEWith ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
18With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works.
19Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade :Two or more coats on new work
20ALUMINIUM WORKSProviding and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) :For fixed portionAnodised aluminium (anodised transparentor dyed to required shade according toIS: 1868, Minimum anodic coating of gradeAC 15)
21For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium (anodised transparentor dyed to required shade according toIS: 1868, Minimum anodic coating of gradeAC 15)
22Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions ofengineer-in-charge . (Cost of aluminium snap beading shall be paidin basic item):With float glass panes of 5 mm thickness (weight notless than 12.50 kg/sqm)
23Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete.Fixed to steel windows by welding
24FLOORING WORKSProviding and laying flamed finish Granite stone flooring in requireddesign and patterns, in linear as well as curvilinear portions of the buildingall complete as per the architectural drawings with 18 mm thick stoneslab over 20 mm (average) thick base ofcement mortar 1:4 (1 cement: 4coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing,curing and polishing etc. all complete as specified and as directed by theEngineer-in-Charge:Polished Granite stone slab of all colour and texture exceptBlack, Cherry/Ruby Red
25Providing and laying flamed finish Granite stone flooring in requireddesign and patterns, in linear as well as curvilinear portions of the buildingall complete as per the architectural drawings with 18 mm thick stoneslab over 20 mm (average) thick base ofcement mortar 1:4 (1 cement: 4coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing,curing and polishing etc. all complete as specified and as directed by theEngineer-in-Charge:Flamed finish granite stone slab Jet Black, Cherry Red, EliteBrown, Cat Eye or equivalent.
26Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easilyGlazed Vitrified tiles Matt/Antiskid finish of size( Size of Tile 600 x 1200 mm )
27Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete ( Wall Tiles ) Size of Tile 600x600 mm
28Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
29SS RAILING WORKProviding and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
30WATER PROOFING WORKProviding and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
31Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.
32Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
33WOOD WORKS :Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle thresholdof mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards,lock strike-plate and shock absorbers as specified and applying a coatof approved steel primer after pre-treatment of the surface as directedby Engineer-in-charge:Profile CFixing with adjustable lugs with split end tail toeach jamb
34Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board construction withframe of 1stclass hard wood and well matched teak3 plyveneering withvertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws
35WPC DOOR FRAME FOR TOILETSProviding and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Frame size 65 x 100 mm
36WPC DOOR SHUTTER FOR TOILETSProviding and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)35 mm thick
37DOOR FITTINGS :Providing and fixing bright finished brass butt hinges with necessaryscrews etc. complete:125x85x5.5 mm (heavy type)
38Providing and fixing bright finished brass parliamentary hinges withnecessary screws etc. complete:150x125x27x5 mm
39Providing and fixing bright finished brass tower bolts (barrel type) withnecessary screws etc. complete:250x10 mm
40200x10 mm
41Providing and fixing bright finished brass handles with screws etc.complete:125 mm
42Providing and fixing aluminium die cast body tubular type universalhydraulic door closer (having brand logo with ISI, IS : 3564, embossedon thebody, door weight upto 35 kg and door width upto 700 mm), withnecessary accessories and screws etc. complete.
43Providing and fixing bright finished brass hanging type floor door stopperwith necessary screws, etc. complete.
44Providing and fixing bright finished 100 mm mortice lock with6 leverswithout pair of handles of approved quality for aluminium door, withnecessary screws etc complete as per direction of Engineer- in-charge.
45Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
46FALSE CEILING:Providing and fixing false ceiling at all heights including providing and fixing of frame work made ofspecial sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm widex 1.6mm thick with flanges of 27 mm and 37mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with6 mm dia bolts, other flange of cleat fixed to the angle hangers of25x10x0.50 mm ofrequired length with nuts& bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed ina direction perpendicular to G.I. intermediate channel with connecting clips made outof2.64 mm diax 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws@ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x 25 mm at 230 mm c/c, including jointing and finishing toa flush finish of tapered and square edges ofthe board with recommended jointing compound, jointing tapes, finishing with jointing compound in3 layers covering upto 150 mm on both sides ofjoint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge butexcluding the cost of painting with: 12.5 mm thick tapered edge gypsum moisture resistant board
47SANITARY & WATER SUPPLY WORKSWASH BASINProviding and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm witha pair of 15 mm C.P. brass pillar taps.
48EUROPEAN TYPE WATER CLOSET (WC)Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
49FITTINGS & ACCESSORIESMIRRORProviding and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
50SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINERProviding and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
51Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
52TOWEL RAIL,TOWEL RACK & TOWEL RINGProviding and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms.
53TOILET PAPER HOLDERProviding and fixing toilet paper holder :C.P. brass
54WASTE COUPLINGProviding and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 38 mm dia of 83 mm length and 77mmbreadth, weighing not less than 60 gms
55BOTTLE TRAPProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
56BIB COCKProviding and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore
57Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
58STOP COCK/ANGULAR VALVEProviding and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore
59Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe32 mm dia
6040 mm dia
61Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming ro IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion.Single socketed pipes.110 mm diameter.
62Providing and fixing wall faced unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion.Coupler110mm
63Bend 87.5°110mm bend.
64Shoe (Plain)110mm Shoe.
65WATER SUPPLY PIPINGProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per directionof Engineer in Charge.Concealed work, including cutting chases and making good the walls etca) 15 mm dia
66b) 20 mm dia
67c) 25 mm dia
68d) 32 mm dia
69Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.EXTERNAL WORKb) 20 mm dia
70c) 25 mm dia
71d) 32 mm dia
72e) 40 mm dia
73f) 50 mm dia
74g) 65 mm dia
75Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore.
7640 mm nominal bore.
7765 mm nominal bore.
78Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
79Fire fighting system Providing, fixing, jointing, testing and commissioning M.S. pipe to I.S. 1239 (Heavy class) with fittings like, unions, couplings, bends, elbows. tees. offsets. reducers, frames. Painted MS structural supports. hangers. fasteners etc. as directed complete the work as per the requirement at site including painting with two coats of synthetic enamel paint. over a coat of primer after surface preparation, cutting and making good the walls complete. 80 mm dia
80100 mm dia
81Providing, fixing, testing and commissioning of cast iron butterfly valves of PN 16 working pressure with SS-316 grade disc working pressure with S.S disc with bolts, nuts, 3 mm thick compressed asbestos gasket, companion flanges as per table \\"E\\" complete in all respects, including provision for locking with pad lock arrangement, supply and fixing of seven lever pad lock with universal key150 mm dia
82100 mm dia
83Providing, fixing, testing and commissioning C.I. dual plate wafer type non return valves tested for PN 16 working pressure with SS 316 grade disc including washer, nuts, bolts, 1.5 mm thick compressed asbestos gasket companion flanges as per table \\"E\\" complete in all respects.150 mm dia
84Providing, fixing, testing and commissioning S.S 304 grade collecting head with 63 mm dia instantaneous type inlet and 150 mm dia flanged outlet with built in check valve for fire brigade connection to under ground tanks and fire risers ( IS. 904 -1965 ) complete in all respects with companion flanges, nuts, bolts, gaskets etc2 Way
85Providing, fixing testing and commissioning standard short size S.S 304 grade branch pipe with SS 304 grade nozzle 16 mm dia outlet (Conforming to I.S. 903) with standard instantaneous type 63 mm dia coupling.
86Providing, fixing testing and commissioning first aid fire hose reel drum, wall mounting, swinging type fitted with 20 mm dia 36.5 m long thermoplastic hose to I.S. 12585 with 5 mm SS nozzle with shut off valve (I.S. 884-1969).
87Providing and fixing IS] marked S.S 304 grade fire hydrant valve 80 mm inlet with single outlet and fitted with 63 mm dia instantaneous female coupling on the outlet complete including companion flange as per table \\"E\\", PVC blank cap and chain, nuts, bolts and 3 mm thick compressed asbestos gasket at locations as per drawings (Conforming to 1.S.5290-1993 Type- A).80 mm dia
88Providing and fixing 63 mm dia 15 m long EPDM lined fabric hose including SS 304 grade male and female instantaneous type coupling approved by fire authority, machine wound with copper wire complete in all respects. Hose shall conform to I.S. 636 Type A and coupling to I.S. 903-1975 with ISI certification15 mtr long
89Providing and fixing fire hose cabinet fabricated from 16 gauge red coloured powder coated aluminium sheet with single or double glazed front door and pad locking arrangement, including supply of pad lock with universal key, \\"Fire Hose\\" written on front including necessary supports/ mounting arrangement750 x 450 x 250
90Providing and fixing dial type glycerine filled pressure gauge with isolation cock. 100 mm dia suitable for 0- 15 kg/sq.cm range
91Providing and fixing full bore type brass ball valve with chrome plated brass ball, teflon seating and ring, full bore type with lever and screwed female ends suitable for working pressure of 20 kg/sq.cm. as per IS 12992 (Valve inside FHC)25 mm dia
92Providing, fixing, testing and commissioning gun metal single acting air valve suitable for 20 Kg/Sq.cm working pressure with screwed inlet 25 mm dia as per IS 12992 with 25 mm dia isolation ball valve rated for 20 Kg / Sq.cm complete in all respects25 mm dia
93PUMP MOTOR & PANELFIRE EXTINGUISHERProviding and fixing CO2 extinguisher consisting of seamless MS cylindrical body squeeze lever discharge valve, internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle ISI marked as per IS 15683 including fixing with dash fasteners etc completeCapacity 4.5 kg
94Providing and fixing ceiling mounted automatic ABC dry powder type extinguishers consisting of welded M.S. cylindrical body, ISI marked as per IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal chargesCapacity 4 kg
95Electrical workWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
96Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
97Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
98Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
99Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
100Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
101Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
102Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire Metre
103Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 10 sq. mm + 1 X 6 sq. mm earth wire
104Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.1 Pair
105Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
106Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required
107Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
108Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
109Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
110Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet
111Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
112Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
113Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
114Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
115Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
116Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
117Supplying and fixing brass batten/ angle holder including connection etc. as required.
118Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
119Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
120Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings)
121Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required
122Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required100 A,30KA,FPMCCB
123Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door
124Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
125Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
126Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
127Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
128Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
129Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
130Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required40 Amps
131Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 Amps
132Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
133Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
134Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
135Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
136Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required
137Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
138Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required
139Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
140Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
141Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm
142Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm
143Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
144Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal)
145Supply, installation, testing and commissioning of 1200 mm sweep, BEE 5 Star rated ceiing fan with Brush Less Direct Current (BLDC) Motor, class of Insulation:B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (Toerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remeining accessorries including safety pin, nut bolts, washers, temperature rise=75 degree C (Max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
146AC OUTDOOR UNITSupply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5
147Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
148Supplying and fixing of Philips/ Bajaj or equivalent LED Square Down Light fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required. LED Square Down Light Fittings 24 W
149Supplying and fixing of Philips/ Bajaj or equivalent LED round fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required. LED Round Light,15 W
150Supplying and fixing of Philips/ Bajaj or equivalent LED Batten Light fittings complete with with all connection cable, as approved by the Deptt.s etc. as required.
151supply, fitting, fixing of 25A Modular Motor Starter 2Module, including making necessary connection at Pensioner's rest room at ground floor of Administrative Building, Gauhati University
152Supplying including installation, testing and commissioning of Voltas/Daikin or equivallent 1.5TR (Inverter 3*) Hi-wall Split AC Unit complete with all connection as required and as specified and directed
153Supplying including installation, testing and commissioning of Voltas/Daikin or equivallent 2.0TR (Inverter 3*) Hi-wall Split AC Unit complete with all connection as required and as specified and directed
154Supplying and fixing of 300 mm AC Exhaust fan in the existing hole complete with all connection as approved by the Deptt.s etc. as required.
155Supplying following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in existing trench as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make)240.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
156MAIN LT DISTRIBUTION PANELSupplying and installation of metal enclosed pedestal mounted front operated cubical type switch gear panel suitable for indoor installation conforming to IS: 8623 (Part I & II). The Panel should be made of sheet steel and thickness not less than 1.6mm and structural steel having light section. The panel shall be completely dust tight and vermin proof and shall be painted with anti corrosive and anti condensation type two coats of primer and two coats of paint. All wiring shall be PVC insulated and PVC sheathed of 1100 volt grade of required size. The panel should have provision of entry of cable at the bottom and also provision of outgoing feeders from the bottom of the panel. The bus bar shall be of high quality TPN 150A Aluminium of uniform cross section. The panel shall consist of the following items (viz. voltmeter, ammeter, CT, indicating lamps, selector switch etc.) connected as per drawing and shall be flush mounted on the front of the panelINCOMER: a) 400A, 4P, 36KA, MCCB - 1 No.b) Spreader Link for 400A, 4P, MCCB (Set of 8Pcs) - 1 Setc) Digital Voltmeter (0-500V) - 1 No.d) Digital Ammeter (0-150A) - 1 Nos.e) 6A, Volt Selector Switch - 1 Nos.f) 6A, Ammeter Selector Switch - 1 Nos.g) LED Indicator lamp R, Y, B- 3 Nos.h) CT 400/5A, CI-1, Tape wounded- 3 Nos.i) 6A, SP, MCB- 3 Nos.j) Bus-Bars: 500 A TPNOUTGOING:.a) 63 A, 4 Pole, 25 KA, MCCB = 2 Nosb) 100 Amps, 4 Pole, 25 KA MCCB wth Spreather Link = 3 Sets
157LT DISTRIBUTION PANEL (POWER)Supplying and installation of metal enclosed pedestal mounted front operated cubical type switch gear panel suitable for indoor installation conforming to IS: 8623 (Part I & II). The Panel should be made of sheet steel and thickness not less than 1.6mm and structural steel having light section. The panel shall be completely dust tight and vermin proof and shall be painted with anti corrosive and anti condensation type two coats of primer and two coats of paint. All wiring shall be PVC insulated and PVC sheathed of 1100 volt grade of required size. The panel should have provision of entry of cable at the bottom and also provision of outgoing feeders from the bottom of the panel. The bus bar shall be of high quality TPN 150A Aluminium of uniform cross section. The panel shall consist of the following items (viz. voltmeter, ammeter, CT, indicating lamps, selector switch etc.) connected as per drawing and shall be flush mounted on the front of the panel.INCOMER: a) 400A, 4P, 36KA, MCCB 1 NOS. b) Spreader link for 400A, TP+N, MCCB (Set of 4Pcs)-2 Setsc) Digital Multifunction meter (V,A,PF,KW,KWH) -1 No.d) LED Indicator lamp R,Y,B -3 Nose) 6A, SP, 10KA, MCB \\"C\\" Series for Control Fuse-3 Nos.OUTGOING:a) 100A, 4P, 25KA, MCCB (For Light Panel) = 4 Nos.b) Spreader link for 100A, 4P, MCCB (Set of 4Pcs) = 4 Setsc) 40A, 4P, 25KA, MCCB (For Ground & First Floor) = 2 Nos.
158LT DISTRIBUTION PANEL (LIGHT)Supplying and installation of metal enclosed pedestal mounted front operated cubical type switch gear panel suitable for indoor installation conforming to IS: 8623 (Part I & II). The Panel should be made of sheet steel and thickness not less than 1.6mm and structural steel having light section. The panel shall be completely dust tight and vermin proof and shall be painted with anti corrosive and anti condensation type two coats of primer and two coats of paint. All wiring shall be PVC insulated and PVC sheathed of 1100 volt grade of required size. The panel should have provision of entry of cable at the bottom and also provision of outgoing feeders from the bottom of the panel. The bus bar shall be of high quality TPN 150A Aluminium of uniform cross section. The panel shall consist of the following items (viz. voltmeter, ammeter, CT, indicating lamps, selector switch etc.) connected as per drawing and shall be flush mounted on the front of the panel.INCOMER: a) 63A, 4P, 25KA, MCCB 1 NOS. b) Spreader link for 63A, 4P, MCCB (Set of 4Pcs) -2 Setsc) Digital Multifunction meter (V,A,PF,KW,KWH) -1 No.d) LED Indicator lamp R,Y,B -3 Nose) 6A, SP, 10KA, MCB \\"C\\" Series for Control Fuse-3 Nos.OUTGOING:a) 40A, 4P, 10KA, MCB = 5 Nos.
159Supplying including installation, testing and commssioning of 10 Passenger / 608 Kg., 5 stop, 5 opening, one entrance, Manospace Smart Passenger Elevator (KONE/Equvalent Make) complete as required and as directed
160Supplying & Instalation of 11/0.4 KV, 160 KVA, Copper Wound, BIS Level-2, Distributin Transformer complete with all connection as required ans as directed
161Providing & Installation of 11 KV, 400 Amps GOAB Switch cum Horn Type Fuse Set Complete with all connection as required
162Providing & Installation of 11 KV, DO Fuse Set Assemblyt Complete with all connection as required
163Providing & Installation of 11 KV, 5 KA Lighting Arrestor (Line Type, Distribution Class) Complete with all connection as required
164Suplying including fitting fixing of Pole Clamp of GI Flat 50 mm x 6 mmwith required nuts & bolts etc.
165Suplying including fitting fixing of 11 KV Pin Insulator (Polymeric) 5 K.N. (F.R.P. 24 M.M.) complete with all connection as required.
166Suplying including fitting fixing of Metering Cabinet as required and directed
167Suplying including fitting fixing of Microprocessor Based with in Built Earth Fault Protection Module 4 Pole MCCB 400 Amps ICS = 100% ICU 35 KA (Minimum) complete with all connection as required.
168Suplying including Installation of C.I. Earth Pipe 1.80 Meters Inner Dia 100 M.M. Outer Dia 110 M.M. with Perforated Holes of 15 M.M. Dia at 30 C.M. Interval along Length of the Pipe.
169Supplying & Laying of Hot Dip G.I. Wire, 6 S.W.G.as required
170Supplying of GI Steel Tubular Pole, SP -66 (12.0 Metre) as required
171Supplying and erection of 11 KV, 1 Core, 240 Sq.mm, AAAC Covered Conductor as required
172Construction of Transformer Pad for Distribution Transformer as Per Specification
173Suppying including installation, testing, commissioning of, 11 K Grade, 3ph, 4 w, combined CT/PT accuracy class 05, 400/5 A, STC 1& KA for 1 sec
174Supplying & erection of GI Channel 100x50x6 mm as required
175Providing DTR Fencing as Per REC Standard Specification complete with Materials & Labour Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56060170
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 3.77 Crore
LAST DATE 13-07-2026
Authority
Authority Name Guwahati University
Work Description Tender for Vertical Extension Of Slet Commission Building (Second Floor, Third & Fourth Floor & Remaining Few Finishing Works Of First Floor) At Jalukbari Guwahati Assam
Basic Detail
Tender No T/26-27/18 Date 15.06.2026
Bidding Type Tender
Location
City Kamrup Metro
State Assam
Key Dates
Publish Date 18 Jun 2026
Submission Date 13 Jul 2026
Open Date 14 Jul 2026
Finance
Tender Value 3.77 Crore
Tender Fee 8000
EMD 7.54 Lakhs
Exemption Available
Document List
46933ce5-e0e5-4722-8cb2-fea14808a766.html
BOQ_83322.xls
FormofBid.pdf
nit.pdf
Tendernotice_1 (9).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Jul 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

46933ce5-e0e5-4722-8cb2-fea14808a766.html

xls

BOQ_83322.xls

pdf

FormofBid.pdf

pdf

nit.pdf

pdf

Tendernotice_1 (9).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender