| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil |
| 3 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : |
| 4 | All kinds of soil |
| 5 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 8 | 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 11 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 12 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 13 | 160 mm diameter |
| 14 | 110 mm diameter |
| 15 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 16 | Coupler |
| 17 | 110mm |
| 18 | 12 mm cement plaster of mix: |
| 19 | 1:6 (1 cement: 6 coarse sand) |
| 20 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : |
| 21 | 1:3 (1 cement: 3 fine sand) |
| 22 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead : |
| 23 | With cement mortar 1:4 (1cement: 4 coarse sand). |
| 24 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 25 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 26 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 27 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 28 | 10 litre capacity - White |
| 29 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 30 | Semi rigid pipe |
| 31 | 32 mm dia |
| 32 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
| 33 | 20 mm nominal outer dia .Pipes. |
| 34 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 35 | 15mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 36 | Providing and fixing PTMT stop cock of approved quality and colour. |
| 37 | 15 mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 38 | Providing and fixing PTMT pillar cock of approved quality and colour . |
| 39 | 15mm nominal bore, 107 mm long. Weighing not less than 110 gms. |
| 40 | Providing and fixing PTMT grating of approved quality and colour. |
| 41 | Circular type. |
| 42 | 125 mm nominal dia with 25 mm waste hole. |
| 43 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. |
| 44 | 20 mm nominal bore, 120 mm long. Weighing not less than 198 gms. |
| 45 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. |
| 46 | 15 mm nominal bore with 45 cm length. |
| 47 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: |
| 48 | 150 mm diameter S.W. pipe |
| 49 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
| 50 | For pipes 100 to 250 mm diameter |
| 51 | Providing and fixing CPVC Gate valve in CPVC pipe including cutting and pasting the pipe and making good etc. complete |
| 52 | 20 mm nominal outer dia .Pipes. |
| 53 | Engaging beldar/sewerman as and when required on call basis(whole day) as per requirement to attend severe choking complaint, and also may be used in cleaning sweeping of toilet etc. (Acid, bamboo, cleaning rod ,ladder, rope will be provided by the agency .) |
| 54 | Disposal of liquid sludge received from septic tank/manholes by diesel running vehicle mounting hydraulic operated high pressure suction machine fitted with pump having 3000 litres suction capacity tank including skilled operator, supervising engineer etc. to municipal dumping ground at a distance approximately 5.0 Km all complete as per direction of E-I-C. Please Enable Macros to View BoQ information |