| 1 | Item No.14.5.1 - Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of thickness 4 mm - Float glass panes of thickness 4mm |
| 2 | Item No. 14.9- Renewal of old putty of glasspanes (length). |
| 3 | Item No. 14.10- Refixing old glass panes withputty and nails |
| 4 | Item No. 17.1.1 - Providing and fixing water closet squatting pan (Indian type W.C. pan)with 100mm sand cast Iron P or S trap, UPVC P or S trap, 10 litre low level white P.V.C. ushing cistern,including flush pipe, with anuallycontrolled device (handle lever) conforming to IS : 7231, with allfittings and fixtures complete including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. |
| 5 | Item No. 14.1- Repairs to plaster of thickness12mm to 20mm in patches of area2.5 sq. metres and under includingcutting the patch in proper shape,raking out joints and preparing and plastering the surface of the walls complete including disposalof rubbish to the dumping ground within 50metres lead : With cement mortar 1:4 |
| 6 | Item No. 9.201.1 - Providing and fixing factory made integral PVC flush door shutter made from rigid PVC foam sheet (Single Extruded) with density not less than 600 kg/cum, conforming to IS: 2380 part 14 for screw holding strength with Celluka finish surfaces on both sides at the manufacturing process itself, manufactured by an ISO : 9001 -2000 certified company 24 to 25 mm thick plain solid PVC flush door shutter For wc and bath rooms |
| 7 | Item No. 10.1- Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 8 | Item No. 15.15.1- Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: of area 3 sq. metres and below |
| 9 | Item No.9.66.3- Providing and fixing ISI marked stainless steel tower bolt black finish, (Barrel type) with necessary screws etc. complete :150x10 mm |
| 10 | Item No. 9.68.2 -Providing and fixing ISI marked stainlesssteel door latches with screws etc.complete : 250x20x6 mm |
| 11 | Item No. 9.69.2 -Providing and fixing ISI marked stainlesssteel handles with necessary screws etc.complete : 100mm |
| 12 | Item No. 14.29 -Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: Old work (one or more coats). |
| 13 | Item No.15.19.2 - Dismantling steel work in single sections includingdismembering and stacking within 50 metres lead in: Channels, angles, tees and flats |
| 14 | Item No.12.32.2- Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipesconforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm diameter (minimum wall thickness 2.2mm) |
| 15 | Item No. 12.33.1.2 -Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm) Coupler - 110 mm (minimum wall thickness2.2mm) |
| 16 | Item No. 12.33.4.2 -Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm) Single tee without door - 110x110x110 mm (minimum wall thickness 2.2mm) |
| 17 | Item No.12.33.5.2 -Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm) Bend 87.5° - 110 mm bend (minimum wall thickness 2.2mm) |
| 18 | Item No.12.33.6.2 -Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm) Shoe (Plain) - 110 mm Shoe (minimum wallthickness 2.2mm) |
| 19 | Item No. 17.58.1 -Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum 75 mm diameter |
| 20 | Item No. 17.58.2-Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum 110 mm diameter |
| 21 | Item No.17.59.3.1 -Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type ASingle tee with door 75x75x75 mm |
| 22 | Item No. 17.59.3.2 -Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type ASingle tee with door 110x110x110 mm |
| 23 | Item No.17.59.4.1 -Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type Single tee without door 75x75x75 mm |
| 24 | Item No.17.59.4.2 -Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type Single tee without door 110x110x110 mm |
| 25 | Item No.12.37.2- Providing and fixing 100 mm/110 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 sand) Upvc spout (Pipe dia.110 mm) |
| 26 | Item No.9.43.1-Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. |
| 27 | Item No. 9.73.2- Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete 100x58x1.90 mm |
| 28 | Item No.9.57.1-Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete: 300x16 mm |
| 29 | Item No.9.57.2-Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete: 250x16 mm |
| 30 | Item No. 9.58.2-Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 200x10 mm |
| 31 | Item No.9.58.3 -Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 150x10 mm |
| 32 | Item No.9.61.1-Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm |
| 33 | Item No.9.61.2-Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 100mm |
| 34 | Item No.9.63.1- Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 300 mm weighing not less than 200 gms. |
| 35 | Item No.10.10.1- Providing and fixing factory made ISI marked glazed steel doors, windows and ventilators side /top /centre hung with beading and Z-section all members suchas F7D, F4B, K11 B and K12 B and other tubular section member etc. complete of standard rolled steel sections, joints mitredand flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings,complete all as per approved design (sectional weight of only steel members shall be measured for ayment). Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of Cement Concrete 1:3:6(1 Cement : 3 sand : 6 graded stoneaggregate 20 mm nominal size). |
| 36 | Item No.4.1.1.3-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level With 20mm nominal size graded stone aggregate.: M-15 – Grade concrete |
| 37 | Item No 4.2.1.3- Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto With 20mm nominal size graded stone aggregate M 15 – Grade concrete |
| 38 | Item No. 4.3.2 - Centering and shuttering including strutting,propping etc. and removal of form work for : above plinth: Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, and string courses fillets etc. |
| 39 | Item No. 14.64 -Chipping, Removing, Carefully loose plaster and Concrete work by low impact Hammer, Breaker without damaging the structure as Instructed by Engineer-in-Charge. |
| 40 | Item No. 22.23- Providing water proofing treatment over Roof, Wall, Chhajjas, Balcony with Rubberized elastomeric cold applied liquid waterproofing membrane blend of special resin and rubber with more than 1300% elongation (confirming ASTM-D2370-98), at leakage/seepage |
| 41 | Item No. 10.21 -Welding by gas or electric plant includingtransportation of plant at site etc. complete. |
| 42 | Item No. 19.21.1.1 - Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved qualityRectangular shape Light duty D- 2.5 600x450mm internal dimensions |
| 43 | Item No. 9.46.1 - Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm all complete. With 2nd class teak wood beading 62x19 mm. |
| 44 | Item No.6.6.2 - Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg / cm2 and waterabsorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etccomplete. Please Enable Macros to View BoQ information |