|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with piano typeswitch, phenolic laminated sheet, suitable size M.S.box and earthing the point with 1.5 sq.mm.FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group B |
| 2 | Wiring for circuit/ submain wiring along with earth wirewith the following sizes of FRLS/HFFR PVC insulatedcopper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 3 | Wiring for circuit/ submain wiring along with earth wirewith the following sizes of FRLS/HFFR PVC insulatedcopper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | Wiring for circuit/ submain wiring along with earth wirewith the following sizes of FRLS/HFFR PVC insulatedcopper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 5 | Supplying and fixing two module stepped typeelectronic fan regulator on the existing modular plateswitch box including connections but excludingmodular plate etc. as required. |
| 6 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 7 | Supplying and fixing metal box of 180mm X 100mm X60mm deep (nominal size) on surface or in recesswith suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 Asocket outlet and 15/16 A piano type switch,connections, painting etc. as required. |
| 8 | Supplying and fixing 3 pin, 5 A ceiling rose on theexisting junction box/ wooden block includingconnections etc. as required. |
| 9 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 10 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following bodymaterial and construction as per IS : 10322 withdriver (Replaceable) as per the requirement withDriver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KVwith Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker shouldbe below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hourswith 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard DeviationColour Matching) <3, Maximum power consumptionshould not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copperconductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18-22 Watt |
| 11 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver asper the requirement with Driver efficiency >85%,Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10%as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and theproject requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 100 watt |
| 12 | Supplying ,Installation, Testing, Commissioning of Decorative, wall mounting fixture, in durable plastic body & designer mesh in gold finish suitable for 9 W LED lampwall bracket of all sizes and shapes containing 01 No 9 Watt LED lamp per fitting, complete with all accessories including connections etc. as required |
| 13 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 14 | Supply, installation, testing & commissioning of 380 mm sweep metal body heavy duty AC exhaust fan with lover shutter having Corrosion resistant body, minimal noise operation & maintenance free design, Totally enclosed, highly efficient heavy duty motor with pressure die cast aluminium rotor mounted on two ball bearings, Aerodynamically contoured blades handle maximum air with minimum power consumption, Rigid frame with rubber mountings for silent operation, Conforming to IS: 2312 -1967, IP55 rated product (protected from limited dust ingress and from low pressure water jets from any direction), power input - 166 watt, speed - 1400 r/min (RPM) , Air delivery - 3700 m3 /h , operate on - 220 V-240 V, Rated Frequency - 50 Hz, Noise Level - 65-70 dB .(Make- Havells/CG/ Usha/Khiaitan) including making the hole etc as required |
| 15 | Supplying and fixing following way, single pole andneutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door |
| 16 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 17 | Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 40 Amp |
| 18 | Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 63 A |
| 19 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mmdia including accessories, and providing masonryenclosure with cover plate having lockingarrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 20 | Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providingmasonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 21 | Providing and fixing 6 SWG dia G.I. wire on surfaceor in recess for loop earthing along with existingsurface/ recessed conduit/ submain wiring/ cable as required. |
| 22 | Providing and fixing of lightning conductor finial, madeof 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 23 | Jointing copper / G.I. tape (with another copper/ G Itape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 24 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 25 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 26 | Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 27 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 50 sq. mm (35mm) |
| 28 | Supplying & Laying of one number 3.5 core , 50 Sq mm , stranded type aluminium conductor , XLPE insulated ,cores laid up, PVC innersheathed , armoured cable ,extruded PVC type ST2 outer Sheathed , 650/1100 V grade as per IS 7098 (part-1) 1998 with upto date amendments, in the 50 mm dia G.I. pipe (medium class) including Providing, laying and fixing 50 mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required ( Cable make- Havells/KEI/Polycab or its equivalent acceptable brand) and ( Pipe Make- Jindal/Tata or its equivalent acceptable brand) |
| 29 | Supplying & Laying of one number 3.5 core , 50 Sq mm , stranded type aluminium conductor , XLPE insulated ,cores laid up, PVC innersheathed , armoured cable ,extruded PVC type ST2 outer Sheathed , 650/1100 V grade as per IS 7098 (part-1) 1998 with upto date amendments, in the through 65 mm dia G.I. pipe (light class) including Providing and fixing , bending same G.I. pipe along with pole complete as required. ( Cable make- Havells/ KEI/ Polycab or its equivalent acceptable brand) and ( Pipe Make- Jindal/Tata or its equivalent acceptable brand) |
| 30 | Supply, Installation, testing and commissioning of double door LT eletrical panel, indoor type floor/Wall mounted , IP 42, of following capacity for 3 phase, 415 V + 10 %, 50 Hz AC System for Ambient temperature -5°C to +40°C, fabricated in compartmentalised designed made of CRCA sheet steel (CPRI approved) of 2.0mm thick for framework of size 900 mm X 900 mm X 300 mm deep The panel shall be openable from front side and also consists of angle iron frame of size 900 mm X 900 mm X 300 mm with 4 legs of 600 mm long made out of 35 X 35 X4 mm thick angle iron . & covers, 3 mmthick for deattachable gland plate i/c cleaning & finishing complete with 7 tank process for powder coated of approvedshade ( RAL 7032-Siemens Gray or as approved by Engineer-in-Charge), connection & inter onnection withsuitable size & rating aluminium strip or single core copper cable having front section (switch gear and control accessories) and rear section Bus bar , having 100 Amp carrying capacity, TPN Aluminium alloy bus bar of high conductivity, DMC/SMC bus bar supports,, entire panel shall have common copper earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs,The Panel shall be in compliance with (IS :16636). The panel shold be consist to following switch gear and protection devices (i) 100 Amp , 415 V, 50 Hz ,FP, Adjustable thermal, Fixed magnetic releases , Icu at 415V=25KA,(rms) Ics at 415 V = 25KA (rms) Conforms to IS/IEC 60947-2) (ii) Neon Light Indicator -03 Nos for RYB Phase (iii) 63 Amp DP MCB , Icu=Ics at 230 V =10 KA , C Curve (In accordance with IS/IEC 60898-1) (iv) 63 Amp, 230 V, 50 Hz. Phase selector switch 1 pole - 3nos Please Enable Macros to View BoQ information |