| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 4 | 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 7 | 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 10 | Foundations, footings, bases of columns, etc. for mass concrete |
| 11 | Suspended floors, roofs, landings, balconies and access platform |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 13 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 15 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 17 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 18 | 300x16 mm |
| 19 | 250x16 mm |
| 20 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 21 | 250x10 mm |
| 22 | 150x10 mm |
| 23 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 24 | 125 mm |
| 25 | 100 mm |
| 26 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 27 | Single rubber stopper |
| 28 | Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both vertical sides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineer- in-charge. |
| 29 | Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (± 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be reinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer's specification and direction of engineer-in-charge. |
| 30 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 31 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 32 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 33 | Providing and laying vitrified floor tiles in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 34 | Size of Tile 600x600 mm |
| 35 | Providing and laying Vitrified tiles in diferent sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 36 | Size of Tile 600x600 mm |
| 37 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. |
| 38 | 0.63 mm thick with zinc coating not less than 275 gm/m2 |
| 39 | Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 nnm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. |
| 40 | Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 41 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 :2000 |
| 42 | 12 mm cement plaster of mix: |
| 43 | 1:4(1 cement: 4 fine sand) |
| 44 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 45 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 46 | Applying priming coat: |
| 47 | With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 48 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 49 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 50 | Two or more coats on new work |
| 51 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: |
| 52 | Two or more coats on new work |
| 53 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 54 | Two coats |
| 55 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 56 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 57 | Painting with oil type wood preservative of approved brand and manufacture: |
| 58 | Old work (one or more coats) |
| 59 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 60 | One or more coats on old work |
| 61 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 62 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 63 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 64 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 65 | Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows. |
| 66 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 67 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 68 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 69 | Of area 3 sq. metres and below |
| 70 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : |
| 71 | Of sectional area 40 square centimetres and above |
| 72 | Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional height of one metre or part thereof beyond 5 metres : |
| 73 | Of sectional area 40 square centimetres and above |
| 74 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 75 | For thickness of tiles 10 mm to 25 mm |
| 76 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 77 | Asbestos Cement sheet |
| 78 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 79 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : |
| 80 | 15 mm to 40 mm nominal bore |
| 81 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: |
| 82 | Up to 150 mm diameter |
| 83 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 84 | Kitchen sink without drain boardi) 470x420 mm bowl depth 178 mm |
| 85 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 86 | 10 litre capacity - White |
| 87 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. |
| 88 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 89 | Flexible pipei) 32 mm dia |
| 90 | Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 91 | Providing and fixing soil, waste and vent pipes : |
| 92 | 100 mm diai) Sand cast iron S&S pipe as per IS: 1729 |
| 93 | 75 mm diameter :i) Sand cast iron S&S pipe as per IS: 1729 |
| 94 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : |
| 95 | For 100 mm dia pipe |
| 96 | For 75 mm dia pipe |
| 97 | Providing and fixing plain bend of required degree. |
| 98 | 100 mm diai) Sand cast iron S&S pipe as per IS: 1729 |
| 99 | 75 mm diai) Sand cast iron S&S as per IS -1729 |
| 100 | Providing and fixing single equal plain junction of required degree : |
| 101 | 100x100x100 mmi) Sand cast iron S&S as per IS - 1729 |
| 102 | 75x75x75 mmi) Sand cast iron S&S as per IS - 1729 |
| 103 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
| 104 | 15 mm nominal dia Pipes |
| 105 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 106 | 20 mm nominal dia Pipes |
| 107 | 25 mm nominal dia Pipes |
| 108 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 109 | 25 mm nominal bore |
| 110 | 20 mm nominal bore |
| 111 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 112 | 45 cm lengthi) 15 mm nominal bore |
| 113 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 114 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 115 | 15 mm nominal bore |
| 116 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 117 | 15 mm nominal bore |
| 118 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 119 | 15 mm nominal bore |
| 120 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fastners of required dia & length (hold fast lugs or dash fastner shall be paid for separately) : Superior hard wood category-II. (A) |
| 121 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. |
| 122 | Superior Hardwood of Cat-II (B) |
| 123 | Providing and fixing 35mm thick panelled or panelled and glazed shutters for doors including ISI marked MS pressed butt hinges with necessary screws with Superior Hard Wood Cat-II(A), Penelling with 12mm thick WPC board all complete as per direction of Engineer-in-charge.a) Superior Hard Wood Cat-II(A)i) 35mm thick shutters. |
| 124 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including black enamelled ISI marked M.S butt hinges with necessary screws. Kiln seasoned and chemically treated superior hardwood cat-II (A).35 mm thick. |
| 125 | Providing and fixing 50 x 12 mm beading for ceiling with superior hard wood category -II (B) including necessary nails & screw etc complete. |
| 126 | Providing and fixing 25 mm thick shutters for cup board etc. : |
| 127 | Panelled or panelled & glazed shutters :i) Superior Hardwood Cat-II (A) including M.S. But hinges with necessary screw. |
| 128 | Dismantling eaves or facia board including stacking of serviceable materials and disposal of un-seviceable of materials within 50 metres lead as per the direction of Engineer-in-charge. |
| 129 | Providing wood work in frames, for roofs trusses, purlins and rafters etc with Superior hardwood category -II (B) including necessary nails bots etc. complete. |
| 130 | Providing and fixing aluminium hooks and eyes.a) 150 mm. |
| 131 | Extra for providing and fixing wind ties of 40x6mm flat aluminium section with necessary screws etc. |
| 132 | Providing and fixing eaves or facia baord with 19mm thick WPC board 30 cm wide including fixing with GI nut and bolts etc. complete. |
| 133 | Providing and fixing CPVC gate valve of approved quality (screwed end) : |
| 134 | 20 mm nominal bore |
| 135 | 25 mm nominal bore |
| 136 | Cleaning and clearing of existing tiled flooring by using baking soda paste or suitable commericial tile cleanear including rubbing washing and drying etc. complete as directed by Engineering-charge. |
| 137 | Providing and fixing G.I. staging with G.I pipe of required size including cutting, welding, priming and painting etc. complete. Please Enable Macros to View BoQ information |