| 1 | Provison for Geologist from the tamilnadu agricultural university for inspecting the site for making the borewell point. |
| 2 | Drilling of borewell 250 mm dia vertical bore depth as directed by departmental officers including labour charges for inserting casing pipe assembling in the drilled holes including welding jointing grouting the casing pipe etc |
| 3 | Supply of 200mm PVC casing pipe ISI make of approved brand etc complete |
| 4 | Drilling of borewell 200 mm dia vertical bore depth as directed by departmental officers including labour charges for inserting casing pipe assembling in the drilled holes including welding jointing grouting the casing pipe etc. |
| 5 | Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. |
| 6 | Supply of GI Pipes with Specials., |
| 7 | 50 mm GI pipe ‘B’ class ISI mark |
| 8 | 50 mm GI Bore Heavy Coupling |
| 9 | 50 MM gate valve |
| 10 | 50mm MS clampset |
| 11 | Supply and delivery of 7.5HP borewell submersible pumpset with vertical type with all accessories with latest IS 8034 in general for the following duty conditions the pumpset should have diagonally balanced bronze impler and stainless shaft for motor and pump and directly coupled to a suitable capacity continuous rated three phase fifty cycles 22/440 volts AC supply motor should be as per ISI with upto date amendment. The starter winding should be made from high conductivity PVC insulated 3 core flat copper cable of suitable size of work. Duty 125 LPM X 200 M head., etc., complete as per the direction of departmental officers. |
| 12 | Supply of 4 Sq.mm PVC insulated and sheathed 3 core flat type Copper cable confoeming to IS 694/1990 . |
| 13 | Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). (SOR 2025-26 P-197) |
| 14 | Earth work excavation in all kinds of soil including sand, silt, wet sand under water, black cotton, stiff black cotton, clay, hard stiff clay, hard red earth, murram, stoney earth, gravel and shales etc. excepting all kinds of rock and boulders exceeding 0.014 c.u.m. in volume including rough dressing and dumping the excavated materials away from work site manually within 50m initial lead and 2m initial lift as per the direction of Engineer-in-charge. |
| 15 | Cement concrete 1:4:8 (one cement, foursand and eight aggregate) using 40mm hardbroken granite stone jelly for foundationincluding dewatering if found necessary andlaid in layers of not more than 15 cm thickand compacted etc.,complete complying witstandard specification |
| 16 | Supply and erecting Centering for soffits of centering for sides .,includingstrutting3mhighusingmildsteel sheetsof size90cmX 60cmXandB.G10stiffenedwithM.Sanglesof size25mmX25mmX3mmlaidover silverOak(C.W) joistsof size10cmX6.5cm(spacedat about90cmc/c)andsupporteddycasurinapropsof10cmto13cmdia (spacedof75cmC/C complyingwithstandardspecificationanddirected- 10 m 2 (P & D)Data 38 |
| 17 | PlainCementConcrete1:3:6(onecement,threecrushedStoneSand(M Sand) and six coarse aggregates) using 20mmsize ISS HBGmetal includingcost andconveyanceof allmaterials tositeand including forthemixing, layingand labour charges etc., completeas per standard specificatio |
| 18 | Supplingand fabricatingandplacing inpositionMS (or)R.T.S. bar forreinforcement toallRCCworksasper thedesigngivenincludingcostofsteel and binding wire also in all floors. |
| 19 | supplyingandfixingPrecastReinforcedCementConcrete slabs 100mm thick slab (using 20mm HBGS Jelly) of following thickness inRCCM20concreteusing followingHBGS jellyexcludingcostofreinforcementsteel inpositionbut includingcostof mouldingcharges,castingofslab, finishing,curingandfixinginposition inall floorsetc., completecomplyingwithstandardspecificationandas directed. Please Enable Macros to View BoQ information |