Tender For Repair And Maintenance Of Internal Electrification And Connected Items In Md/Otm Accn In Inside/Outside Depot Under Ge Banar
Tender Value
35 Lakhs
Estimated cost
Bid Submission
07 Jul 2026
0 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Internal Electrification And Connected Items In Md/Otm Accn In Inside/Outside Depot Under Ge Banar
BOQ
| Sl. No. | Item Description |
| 1 | Taking down copper /alunimium point wiring (light,Fan, Socket, power etc) complete including fixture and fittings such as switches, ceiling roses, pendants,regulator, socket, light fitting of any wattage etc removing material credited to contractor respectively. Item shall be issued on proper gate pass. Including making good disturbed surfaces of walls, floor etc complete all as specified. |
| 2 | Taking down old unserviceable/worn out sub main wiring/service wire of any type and size complete all as specified. |
| 3 | Taking down Main switches/DBs/Metal clade socket of any make and type including teakwood board, MCBs/MCCBs etc complete and making good the disturbed surfaces including colour wash complete all as specified. |
| 4 | M&L for point wiring complete with 1.5 sqmm single core multistranded copper conductor PVC(FRLS) insulated and unsheathed cable in and including PVC casing caping fixed on wall,surface,ceiling etc including 3mm thick, laminated Hylen sheet (white colour) for mounting switches, socket, regulator etc on including sunken type pressed steel terminal boxes screw with washer for fixing with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth and earth dolly for the following :-(a) One light point controlled by one switch complete all as specified. |
| 5 | (b) One fan point controlled by one switch complete all as specified. |
| 6 | (c) One 3 pin 5 Amps Socket outlet point controlled by one switch on independent board complete all as specified. |
| 7 | (d) One 3 pin 5 amps socket outlet point on same board with other switches complete all as specified. |
| 8 | (e) One bell/buzer point controlled by one bell push complete all as specified. |
| 9 | (f) One light point controlled by two 2-way switches complete all as specified. |
| 10 | All as per item No. 04 above here in before but point wiring with 2.5 sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed calbe 1100 volts grade for 15 Amp socket outlet on independent board complete all as specified. |
| 11 | All as per item No. 04 above here in before butr point wiring with 4.0 sqmm single core multistranded copper conductor PVC(FRLS) insulated and unsheathed cable 1100v grade fixed on and including PVC casing caping fixed on wall,surfaces,ceiling etc for with 4.0sqmm single core multistandared copper conductor FRLS PVC insulated and unsheathed cable as earth continuity conductor to common earth and earth dolly. |
| 12 | M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, in PVC rigid conduit heavy duty ISI marked including all accessories fixed on wall,surface,ceiling etc including 3mm thick, laminated Hylen sheet for mounting switches, socket, regulator etc on including wooden/PVC terminal boxes screw with washer for fixing with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth and earth dolly for the following :-a) One light point controlled by one, One-way switch complete all as specified. |
| 13 | b) One fan point controlled by one, One-way switch complete all as specified. |
| 14 | c) One 5 pin 5 Amp Socket outlet point on same board with other switches including earth wire. |
| 15 | d) One 5 pin 5Amp Socket outlet point on independent board complete all as specified. |
| 16 | M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, in PVC rigid conduits heavy duty ISI marked totally concealed in wall/floor/roof including all accessories etc. with Modular sunken boxes including modular frame/cover plate suitable for mounting switches/sockets etc. and PVC insulated stranded copper conductor 1.5 Sq.mm single core cable as earth and connecting to common earth dolly complete all as specified for the following:-Note- (i) Cutting in chases and pointing in will be done by contractor without any cost. (ii) Making good of distrubed surfaces matching with existing finishes will be done by contractor without any extra cost. a) One light point controlled by one, One-way switch complete all as specified. |
| 17 | b) One fan point controlled by one, One-way switch complete all as specified. |
| 18 | c) One 5 pin 5Amp Socket outlet point on same board with other switches including earth wire. |
| 19 | d) One 5 pin 5Amp Socket outlet point on independent board complete all as specified. |
| 20 | e) One bell/buzer point controlled by one bell push complete all as specified. |
| 21 | All as per item no. 16 above but with 2.5 Sq.mm(Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, including PVC insulated stranded copper conductor 2.5 Sqmm single core cable as earth and connecting to common earth dolly complete all as specified for one 15 amps socket outlet point on independent board.Note:- Making good of disturbed surfaces will be done by contractor without any claims. |
| 22 | All as per item no. 16 above but with 4 Sq.mm(Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, including PVC insulated stranded copper conductor 4 Sqmm single core cable as earth and connecting to common earth dolly complete all as specified for one 15 amps socket outlet point on independent board.Note:- Making good of disturbed surfaces will be done by contractor without any claims. |
| 23 | M&L for point wiring complete with 1.5sqmm single core multistranded copper conductor PVC (FRLS) insulated and unsheathed cable in existing PVC conduit or casing caping fixed on wall surface, ceiling etc including 3mm thick laminated hylen sheet for mounting switches sockets regulator etc on existing sunk cast iron terminal boxes, screw with washer for fixing with 1.5 sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable as earth continiuty conductor to common earth and earth dolly for the following. Note: The junction box should be concealed in wall and making good to match the existing surface.a) One light point controlled by one, One-way switch complete all as specified. |
| 24 | b) One fan point controlled by one, One-way switch complete all as specified. |
| 25 | c) One 5 pin 5Amp Socket outlet point on same board with other switches including earth wire. |
| 26 | d) One 5 pin 5Amp Socket outlet point on independent board complete all as specified. |
| 27 | e) One bell/buzer point controlled by one bell push complete all as specified. |
| 28 | All as per item no. 23 above but with 2.5 Sq.mm(Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, including PVC insulated stranded copper conductor 2.5 Sqmm single core cable as earth and connecting to common earth dolly complete all as specified for one 15 amps socket outlet point on independent board.Note:- Making good of disturbed surfaces will be done by contractor without any claims. |
| 29 | All as per item no. 23 above but with 4 Sq.mm(Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, including PVC insulated stranded copper conductor 4 Sqmm single core cable as earth and connecting to common earth dolly complete all as specified for one 15 amps socket outlet point on independent board.Note:- Making good of disturbed surfaces will be done by contractor without any claims. |
| 30 | Supply and fixing in replacement switch Piano flush type 5 Amp single pole complete all as specified. |
| 31 | Supply and fixing in replacement multipurpose socket outlet 2 in 1, 3 pin 5 amps flush type controlled by one switch all as specified |
| 32 | Supply and fixing in replacement switch Piano flush type 15 Amp single pole with neon indicator complete all as specified. |
| 33 | S & F in replacement Socket outlet 2 in 1, 3 pin, 6 and 16 amp flush type controlled by one switch complete all as specified. |
| 34 | S & F in replacement for Bell push, flush type, 5 amp complete all as specified. |
| 35 | Supply and fixing in replacement ceiling rose surface backelite 65x50mm three terminals complete all as specified. |
| 36 | Supply and fixing in replacement fan regulator electronic type for ceiling fan 1200 mm sweep complete all as specified. |
| 37 | Supply and fixing in replacement Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified. |
| 38 | S & F in replacement 240 V, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one 20 amp single pole MCB complete all as specified. |
| 39 | S & F in replacement modular switch 6A 1 module one - way 230V white ivory finish complete all as specified. |
| 40 | S & F in replacement modular switch 16A 1 module one - way 230V white ivory finish complete all as specified. |
| 41 | S & F in replacement modular socket outlet 2/3 pin 6 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops complete all as specified. |
| 42 | S & F in replacement modular socket outlet 2/3 pin 16 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops complete all as specified. |
| 43 | S&F in replacement bell electrical ding dong including hard PVC board ISI marked complete all as specified. |
| 44 | S & F in replacement Modular Bell push 6A 1 module complete all as specified. |
| 45 | S & F in replacement Modular type stepped electronic fan regulator 2 module all as specified & directed. |
| 46 | Supply and fixing in replacement of the following accessories :-(a) White cover plate with frame, 2 module complete all as specified. |
| 47 | (b) White cover plate with frame, 3 module complete all as specified. |
| 48 | (c) White cover plate with frame, 4 module complete all as specified. |
| 49 | (d) White cover plate with frame, 6 module complete all as specified. |
| 50 | (e) White cover plate with frame, 8 module complete all as specified. |
| 51 | M & L in replacement for Sub main wiring complete with single core 1.5sqmm,1100 volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 1.5 sqmm in and including PVC conduit/casing caping and accessories complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 1.5 Sqmm conductor(phase,neutarl, earth) and one run of PVC conduit shall be measured as one unit length.) |
| 52 | M & L in replacement for Sub main wiring complete with single core 2.5sqmm,1100 volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 2.5 sqmm in and including PVC conduit/casing caping and accessories complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 2.5 Sqmm conductor(phase,neutarl, earth) and one run of PVC conduit shall be measured as one unit length.) |
| 53 | M & L in replacement for Sub main wiring complete with single core 6.0sqmm,1100 volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 6.0 sqmm in and including PVC conduit/casing caping and accessories complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 6.0 Sqmm conductor(phase,neutarl, earth) and one run of PVC conduit shall be measured as one unit length.) |
| 54 | M & L in replacement for Sub main wiring complete with single core 4.0sqmm,1100 volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 4.0 sqmm in and including PVC conduit/casing caping and accessories complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 4.0 Sqmm conductor(phase,neutarl, earth) and one run of PVC conduit shall be measured as one unit length.) |
| 55 | S&F in replacement MCB TPN DB 4 way double door with 200 amps rated busbar 415 V, all wire connected MCB with help of lugs, all wire connected with meter is covered with flexible conduit and DB will be fixed concealed/surface with wall neatly etc complete all as specified. |
| 56 | S&F in replacement MCB SPN DB 12 way double door with 200 amps rated busbar 240 V,all wire connected MCB with help of lugs, all wire connected with meter is covered with flexible conduit and DB will be fixed concealed/surface with wall neatly etc complete all as specified. |
| 57 | S&F in replacement MCB SPN DB 8 way, double door, with 200 amp rated busbar 240 V,all wire connected MCB with help of lugs, all wire connected with meter is covered with flexible conduit and DB will be fixed concealed/surface with wall neatly etc all as specified. |
| 58 | Taking down old and Supply and fix in replacement 4 way VTPN DB, 415 V, double door 100 amps rated bus bar, including 100 Amps 4 pole, 16 KA MCCB, making good disturbed surfaces of walls including plaster cutting of wall etc complete all as specified. |
| 59 | S & F in replacement for MCB Single pole rated capacity 6 to 32 amps, 240 V breaking capacity 10 KA ,C- curve complete all as specified. |
| 60 | S & F in replacement for MCB double pole of rated capacity 32/40 amps, 240 volts breaking capacity 10 KA, C-curve complete all as specified. |
| 61 | S & F in replacement for MCB four pole of rated capacity 40 to 100 amps, 415 volts breaking capacity 10 KA, C-curve complete all as specified. |
| 62 | S & F in replacement of LED batten tube light fitting (Warm white/Day white) 24 watts 4 feet long powder coated with opaque diffuser for glare free light complete all accessories internally pre wired, 120 lumen/watt, surge protection 3.5 kV and necessary mounting arrangements complete all as specified. Make; Crompton/Havells/Philips/Wipro |
| 63 | S & F in replacement of LED batten tube light fitting (Warm white/Day white) 10 watts 2 feet long powder coated with opaque diffuser for glare free light complete all accessories internally pre wired, 120 lumen/watt, surge protection 3.5 kV and necessary mounting arrangements complete all as specified. Make; Crompton/Havells/Philips/Wipro Please Enable Macros to View BoQ information |
| 64 | S & F in replacement of LED batten tube light fitting (Warm white/Day white) 10 watts 2 feet long powder coated with opaque diffuser for glare free light complete all accessories internally pre wired, 120 lumen/watt, surge protection 3.5 kV and necessary mounting arrangements complete all as specified. Make; Crompton/Havells/Philips/Wipro Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayJul 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender