| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GE 881 EWS C/O 56 APO NAME OF WORK: REPLACEMENT/REPAIR TO E/M INTERNAL FITINGS/FIXTURES AND WIRING IN VARIOUS UNITS AT BALNOI,SURANKOT AND KG TOP,JHALLAS,LKG,K NALLAH IN THE AOR OF STN HQ KG UNDER GE 881 EWS. Contract No: GE/PNH-44/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Taking down carefully copper/ aluminium unserviceable/ perished point wiring with casing caping (light, fan, socket or power complete) including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site and making good disturbed surfaces of wall, floors, complete all as specified and directed. |
| 3 | Taking down unserviceable sub mains wiring including earth continuity any type / size with surface casing / caping / TW batten / PVC conduit surface or recess and making good disturbed surfaces to match with the existing finishes complete all as specified and as directed. |
| 4 | Point wiring with two single core, 1.5 Sqmm (nominal area) size multistranded copper conductor cable and one single core 1.5 sqmm (nominal area) size copper conductor cable, as earth continuity conductor connected to common earth dolly,1100 volts grade , FRLS, PVC insulated unsheathed cable in and including PVC casing capping of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, Collers, Bend, PVC Conduits for crossisng etc. complete with PVC terminals box for mounting switches, sockets, fan regulators etc for the followings:- |
| 5 | One light/fan point controlled by one switch complete all as specified and directed. |
| 6 | One 5 Pin switch socket combination 6 Amp on same board complete all as specified and directed. |
| 7 | One 5 Pin switch socket combination 6 Amp on independent board complete all as specified and directed. |
| 8 | One bell point controlled by one switch complete all as specified and as directed. |
| 9 | All as per item No.3 above but with two 2.5 sqmm size cable as phase and neutral and one 1.5 sqmm size cable as earth continuity for 15/20 amp multipurpose socket outlet on independent board complete all as specified and directed. |
| 10 | Ceiling rose, 3 terminal, surface bakelite 65 x 50mm complete all as specified and as directed. |
| 11 | Switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed. |
| 12 | Switch piano flush type 6 Amp single pole two way, (ISI marked), complete all as specified and directed. |
| 13 | Switch bell push flush type 6 Amp single pole one way (ISI marked) complete all as specified and directed. |
| 14 | Socket outlet multipurpose combination 2 in 1, 3 pin, 6 Amp flush type universal,complete all as specifed and directed. |
| 15 | Switch socket multipurpose combination 2 in 1, 5 pin, 6 Amp flush type universal,complete all as specifed and directed. |
| 16 | Switch socket multipurpose combination 2 in 1, 5 pin, 5 and 15 Amp flush type universal,complete all as specifed and directed. |
| 17 | Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. |
| 18 | Electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 / 1400 mm sweep complete all as specified and as directed. |
| 19 | Call Bell, ding dong type suitable for 230 / 240 volts AC 50 Hz all as specified and as directed. |
| 20 | LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 21 | LED light fitting 9 / 10 watt bulk head luminaries including LED light driver holder connecing up with three core flexible copper conductor cable of size suitable size. |
| 22 | S&F in repair ceiling mounting LED light fittings luminaire 600mmx600mm, 35/36 watt, 220 v, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver , holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size complete all as specified and as directed. |
| 23 | S&F in repair building security light fittings, 35 watt LED,230v, AC out door type pre-wired, IP-65/66 protection, with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket complete all as directed. |
| 24 | S&F in repair Inverter LED Lamp, CDL, 10 watt, B22 base all as specified and as directed. |
| 25 | S&F in repair LED Driver for 35 Watt LED ceiling light fittings all as specified and as directed. |
| 26 | Supply and Fixing in repair Sheet Metal enclosure for SPN DBs, 4 Ways, Double Door (IP-43), with neutral link complete suitable for 240 Volts, AC, 50 Hz complete all as specified and directed. |
| 27 | All as per item No 25 here-in-before but for 8 way. |
| 28 | All as per item No 25 here-in-before but for 12 way. |
| 29 | S&F in repair MCBs, SPN, 240 volts, breaking capacity 10 KA, rating 40-63 amps, complete all as specified and as directed. |
| 30 | S&F in repair MCB, SP,240 volts, breaking capacity 10 KA, rating 6 to 40 amps, complete all as specified and as directed. |
| 31 | S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm including all connecting accessories complete and as directed by engineer-in-charge. |
| 32 | S&F in repair of PVC counduit non matalic rigid ,of size 25 mm dia (external)incl all accessories use for fixing of conduit on wall and ceiling etc, all as specified and directed. |
| 33 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.5 m below ground level, connected to GI earth wire 4mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I including providing alternate layers of common salt and charcoal arround earth plate, connected to earth test point all as specified or indicated including excavation and connected earth work in any of soil, P.C.C 1:3:6 type C-1 as in pit, 15mm dia GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, 50mm thick R.C.C. 1:2:4 type B-1 cover slab of earth pit reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer, testing on completion including dismantling unserviceable earthing complete all as specified and directed. |
| 34 | Submain wiring with two single core 4 Sqmm PVC insulated, unsheathed, stranded copper conductor cable (FRLS), 1100 volts grade and one single core 2.5 Sqmm as earth continuity conductor drawn in and including PVC casing caping of suitable size with accessories complete all as specified and directed. NOTE: (i) Two run of 4 Sqmm and one run of 6 Sqmm copper cable including casing caping shall be measured as one unit. |
| 35 | All as per item no 33 as above but 10 Sqmm 2 core. |
| 36 | Submain wiring with two single core 6 Sqmm PVC insulated, unsheathed, stranded copper conductor cable (FRLS), 1100 volts grade and one single core 4 Sqmm as earth continuity conductor drawn in and including PVC casing caping of suitable size with accessories complete all as specified and directed. NOTE: (i) Two run of 4 Sqmm and one run of 2.5 Sqmm copper cable including casing caping shall be measured as one unit. |
| 37 | Supply and fix in replacement 1100 volts grade heavy duty cable PVC insulated multi stranded aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat of circular of size 6Sqmm 2 core, complete all as specified and directed. |
| 38 | All as per item ser No 36 above but size of cable 10 Sqmm 2 core. |
| 39 | Taking down of unserviceable ceiling fan of 1200/1400 mm sweep and removing to contractor's workshop for inspection of serviceability of parts, refixing serviceable parts and replacement of unserviceable parts including cleaning, greasing , oiling etc, complete all as specified and directed.Note: (i) Rewinding of stator and new Parts shall be measured and paid separately under relevant items of Sch 'A' as supply only.(ii) Cost of minor part i.e. Cotterr pin, screws shall be deemed to included in the cost of quoted rate. |
| 40 | Bearing good quality for ceiling fan 1200mm/1400mm sweep (ISI marked), complete all as specified and directed. |
| 41 | Gun metal bush for ceiling fan 1200mm/1400mm sweep. |
| 42 | Capacitor 2.5 mfd (ISI marked). |
| 43 | Brass bracket assambly for hanging the ceiling fan 1200mm/1400mm sweep. |
| 44 | 3 core flexible wire 40/.0076, white colour from ceiling rose to fan connector (ISI marked). |
| 45 | Stator shaft for ceiling fan (ISI marked). |
| 46 | S&F in repair ceiling fan from site of 1200/1400 mm sweep and providing new BLDC ceiling fan of 1200 mm sweep, 230 V, 50 hz including all connecting accessories complete all as directed by engineer-in-charge. |
| 47 | Taking out of old burnt winding of any size and type and rewinding of stator winding with superior quality copper wire (ISI marked) including insulation and testing complete all as specified and directed. |
| 48 | Taking down of unserviceable exhaust fan of any size & sweep and removing to contractor's workshop for inspection of serviceability of parts, refixing serviceable parts and replacement of unserviceable parts including cleaning, greasing , oiling etc, complete all as specified and directed.Note: (i) Rewinding of stator and new Parts shall be measured and paid separately under relevant items of Sch 'A' as supply only.(ii) Cost of minor part i.e. Cotterr pin, screws shall be deemed to included in the cost of quoted rate. |
| 49 | Supply only double ball bearing (ISI marked) for exhaust fan of 200 mm sweep to 450 mm sweep fan. |
| 50 | Supply only Gun metal bush for Exhaust fan of any cap, Complete all as specified and directed. |
| 51 | Rewinding of exhaust fan motor with superior quality copper winding wire with insulation and testing complete for the followings sizes:- |
| 52 | 450mm sweep |
| 53 | 300mm sweep |
| 54 | Blade of exhuast fan of 200 mm sweep to 450 mm sweep as per existing make. |
| 55 | S&F in repair LED tube light fittings mirror type with high out put diffuser 2 feet , 10 watt 220 volt AC decorative box type with driver , holder including LED tube light conecting up with three core flexible copper conducor cable of suitable size from ceiling rose complete all as specified and directed. |
| 56 | S&F in repair to replacement of PVC casing caping of size 25 mm incl all fixing accessories all as specified and directed. |
| 57 | Replacement of down rod of ceiling fan with down rod of 15mm bore medium grade GI pipe 0.45 metre long with clamps, bolts, nuts, split pins washers of suitable size of approved quality all as per specified and directed by Engineer in charge. |
| 58 | All as per item no 56 but of length 0.60 Mtr. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |