| 1 | Supply and fix LED street light fitting 90 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish.prismatic polycarbonate cover with individual LED lenses with IP 66 complete with all accessories and necessary fixing arrangement ( Street light bracket) on any type pole at any height complete all as specified and directed. |
| 2 | Supply and fix copper conductor cable, PVC insulated, sheathed,flexible, multistranded ,ISI marked, 1100 volts grade, 3 core , 1.00 sqmm FRLS and including PVC conduit pipe 25 mm and connection and testing complete all as specified and directed. Make:-Havell/Finolex/Plaza/Polycab |
| 3 | Supply and fixing FRP looping box of size 200x140x95 mm with connector and comprising of MCB SP 6 Amps, ISI marked,240V and three phase bus bar for incoming cable and outgoing cable complete with and including providing GI clamps,nuts bolts etc suitable for fixing on PCC pole/ wall and complete all as specified and directed. |
| 4 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core |
| 5 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core |
| 6 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dence soil getting out and levelling of bottom surface to required level all as specified. |
| 7 | Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed |
| 8 | Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed. |
| 9 | Supply and lay Double walled corrugated pipe (DWC ), heavy duty 63/50 mm (OD/ID) bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed. |
| 10 | Supply, Fixing and testing of street light control panel digital 24 Hrs timer of Max load 6 KW, in an inlcuding of contactor rating 32Amp TP, MCB 40Amp TPN, three phase of IP rating IP-54 with internal wiring of panel with FRLSH cable and with in-built short-circuit protection, complete all as specified and directed (Make: Havells, cat No IHXTS03060 or Techno-commercial equivalent of Legrand/ Siemens/ L&T) |
| 11 | M & L for Earthing complete with GI earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised iron strip size 25 x 4 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust, vegetable soil 10 %, Common salt & bentonite powder 10 KG, etc, earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed. |
| 12 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in avg soft/Hard dense soil. |
| 13 | M&L Hard core of gauge n exc 63 mm deposited spreaded and levelled in layers n exc 15 cm thick watered and rammed to a true surface of broken stones or boulders etc |
| 14 | M&L 100 mm thick PCC 1:4:8 type D2 (40mm graded aggregate) as in sub base of flooring.complete all as specified and directed |
| 15 | M&L for 15 mm thick screed bed in CM 1:4 for laying floor tiles. |
| 16 | M&L Chequered cement tiles 20cmx20cmx25cm thick, set, jointed and pointed in neat cement slurry in floor with grey cement and pigment. |
| 17 | M&L for Providing, cement concrete type B1 (1:2:4) using 20 mm graded aggregate in copings, kneelers,apex stons, bed plate,etc rounded or chamfered on edges |
| 18 | Removal of surplus soil of distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed. |
| 19 | Excavation in trenches n,exc 1.5 m wide and n.exc 1.5 m deep for foundation and getting out in hard/dense soil. |
| 20 | M&L PCC 1:4:8 type D2(using 40mm graded aggregate)as in foundation filling and mass concrete etc. |
| 21 | M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete. |
| 22 | M&L for Reinforced cement concrete M-20, 20mm graded aggregate for slabs suspended on walls, beam and column infloor,roofs,landing,balconies,canopies,desck slabs and shelves and the like |
| 23 | M&L for MS TMT bars 10mm dia and over, cut to lenth, bend to shape required, including cranking, bending, sprially for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. |
| 24 | M&L for MS TMT bars 5 mm dia and over, upto and including 10 mm dia in stirrups, spaces and binders. |
| 25 | M&L rendering 15 mm thick in CM 1:4 on concrete surfaces finished even and smooth without using extra cement . |
| 26 | Preparing newly surfacesof plaster or unplaster and applying Two coats of cement base paint on wall surfaces over one coat of primer |
| 27 | Returning filling in including spreading.levelling watering and well ramming in layers not exc 25cm in hard/dense soil Please Enable Macros to View BoQ information |