Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed |
| 2 | S&F in repair Vitreous china Bowl with Cistern for coupled WC with UF soft close slim seat cover, hinges, dual flush cistern fitting and fixing accessories of size 380 x 655 x 765mm, P-trap 180mm complete all as specified and as directed. Make:- CAT part No LYS-WHT-38751P180UFSMZ of Jaquar or any other equivalent approved make. |
| 3 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed. |
| 4 | S&F in repair Vitreous China table top wash basin, white, flat back, size 600 x 440 x 150 mm including brackets complete all as specified and as directed.Make:- CAT part No KUS-WHT-35931PM of Jaquar or any other equivalent approved make. |
| 5 | S&F in repair CP 2 way bib cock with wall flange , complete all as specified and as directed. Make:- CAT Part No FUS-CHR-29041 of Jaquar or any other equivalent approved make. |
| 6 | S&F in repair Pillar cock with extension body , complete all as specified and as directed.Make:- CAT Part No FUS-CHR-29021N of Jaquar or any other equivalent approved make. |
| 7 | S&F in repair Stop valves 15 mm fancy type chromium plated screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 8 | S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed. |
| 9 | S&F Brass chromium plated bottle traps 40mm bore dia for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and as directed |
| 10 | S&F in repair over head shower 150 x 150mm square shape single flow (ABS body chrome plated with gray face plate) with rubit cleaning system complete all as specified and as directed. Make:- CAT part No OHS-35495 of Jaquar or any other equivalent approved make. |
| 11 | S&F in repair Shower arm 20mm dia & 300mm long round shape with 90 degree bend for wall mounted showers with sis flange complete all as specified and as directed.Make:- CAT part No SHA-479L300S of Jaquar or any other equivalent approved make. |
| 12 | S&F in repair Wall mixer with provision for Over head shower with 115mm long bend pipe on upper side connecting legs and wall flanges complete all as specified and as directed.Make:- CAT part No FUS-CHR-29273UPR of Jaquar or any other equivalent approved make. |
| 13 | S&F in repair Sink Cock with pipe swinging spout (wall mounted model) complete all as specified and as directed.Make:- CAT part No COP-CHR-347PM of Jaquar or any other equivalent approved make. |
| 14 | S&F in repair SDG glass wall mirror 600 x 450mm beveled edge, for Bathroom of selected quality glass mounted/ fixed with brass screws to walls complete all as specified and as directed. |
| 15 | S&F in repair Toilet paper holder with flap recessed type stainless steel complete all as specified and as directed. |
| 16 | S&F in repair SS Soap dish complete all as specified and as directed. Make:- CAT Part No F5007106 of CERA or any other equivalent approved make. |
| 17 | S&F in repair Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 18 | S&F in repair SS towel ring square with round flange complete all as specified and directed.Make:- CAT part No ACN-CHR-1121N of Jaquar or any other equivalent approved make. |
| 19 | S&F in repair SS grating doom 125mm dia (minimum weight 40gms) complete all as specified and as directed. |
| 20 | S&F in repair Bib tap cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 21 | M&L PVC (SWR) floor trap (dia of outlet 75mm), plain with grating including jointing with solvent cement complete all as specified and as directed |
| 22 | M&L PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and as directed |
| 23 | Taking down steel tubing and connections (15mm bore dia) , including removal to store complete all as specified and as directed |
| 24 | S&F 3-layer 20 mm PP-R poly propylene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls ceilings or in floors etc. complete all as specified and as directed |
| 25 | S&F in repair PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed |
| 26 | S&F in repair PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed |
| 27 | S&F 75mm dia PVC (SWR) bends any radius complete all as specified and as directed |
| 28 | S&F 110mm dia PVC (SWR) bends any radius complete all as specified and as directed |
| 29 | S&F 110mm dia PVC (SWR) vent cowl complete all as specified and as directed |
| 30 | S&F 75mm dia PVC (SWR) junction single, (single T), equal or unequal complete all as specified and as directed |
| 31 | S&F 110mm dia PVC (SWR) junction single, (single T), equal or unequal complete all as specified and as directed |
| 32 | S&F in repairs 20mm dia Stainless steel curtain rods (heavy weight) complete all as specified and as directed |
| 33 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed |
| 34 | M&L Vitrified Ceramic tiles 10 mm thick light shade (square/ rectangular) polished, area of each tiles n.exc 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 complete all as specified and as directed |
| 35 | M&L Vitrified Ceramic tiles 10 mm thick light shade (square/ rectangular) polished, area of each tiles n.exc 0.36 sqm, in vertical surfaces of wall (skirting) etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing coat in CM 1:4 complete all as specified and as directed. |
| 36 | M&L Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 complete all as specified and as directed. |
| 37 | M&L Glazed ceramic coloured tiles in vertical surface 450x350x7 mm thick set and jointed in neat cement slurry and pointed in coloured cement to match including 10mm thick backing coat in CM 1:4 complete all as specified and as directed. |
| 38 | Demolition of Stone slabs of any description or thickness in floors, aprons etc laid, bedded and pointed in cement mortar |
| 39 | M&L Granite 20mm thick (table rubbed and polished) in steps, Jambs, Pillars, Windows, cills, platforms and like CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigments to match with marble shade of Granite complete all as specified and as directed. |
| 40 | M&L Granite 20mm thick (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. complete all as specified and as directed. |
| 41 | Demolition of Brickwork or stone/boulder masonry, built In cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and rubbish off the premises complete all as specified and as directed. |
| 42 | M&L Brick work with modular fly ash bricks, straight or curved on plan to any radius, built in cement mortar 1:4 complete all as specified and as directed. |
| 43 | M&L Rendering 10mm thick cement plaster on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed. |
| 44 | M&L Preparing new surfaces of plastered wall and priming plastered surfaces with alkali resistant priming paint and then applying two coats of oil bound distemper complete all as specified and as directed. |
| 45 | Demolition of RCC in ground floors n.exc 15cm thickness complete all as specified and as directed. |
| 46 | M&L for RCC 1:2:4, Type B1 using 20mm graded aggregate (Nominal mix) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 47 | S&F for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for flat fair finished surfaces concrete complete all as specified and as directed. |
| 48 | M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed. |
| 49 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 50 | M&L Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed. |
| 51 | Providing & fixing Fully perforated 12mm thick micro regular edged or 10mm thick square edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles at all heights of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000mm, cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws complete all as specified and as directed. |
| 52 | Taking down Chowkats or frames n.exc 1.5 Sqm complete all as specified and as directed. |
| 53 | Taking down Chowkats or frame n.exc 1.5 Sqm each with shutter (without taking off shutters from the frame) complete all as specified and as directed. |
| 54 | M&L 4.8mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc 0.5 Sqm in each pane, with glazing clips complete all as specified and directed. |
| 55 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 56 | Taking down Chowkats or frames with shutters exc 1.5 Sqm each but n.exc 4 sqm each with shutter (without taking off shutters from the frame) complete all as specified and as directed. |
| 57 | S&F factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, complete all as specified and as directed.(Glass or wire mesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 58 | S&F factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 48x40 mm (tolerance ± 1 mm), with wall thickness 2.0 mm(± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and as per directions of Engineer-in-charge |
| 59 | S&F factory made uPVC white colour Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality complete all as specified and as directed.(Glass shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 60 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and as directed. |
| 61 | S&F Factory Made Solid PVC Moulded Door Shutter with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelaminated PVC Sheet on the front face & 2mm prelaminated PVC Sheet on back face complete all as specified and as directed |
| 62 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and as directed. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 63 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and as directed. (Hinges shall be paid separately) |
| 64 | S&F Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor overall 150mm complete all as specified and as directed. |
| 65 | S&F 200 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed |
| 66 | S&F 100mm long Butt hinges medium weight cold rolled stainless steel, and fixed complete all as specified and as directed. |
| 67 | S&F 150mm extruded aluminum alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 68 | S&F 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminum alloy and fixed complete all as specified and as directed. |
| 69 | S&F factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, complete all as specified and as directed. (Glass shall be paid separately).Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 70 | M&L for Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 71 | S&F Pre painted Coloured corrugated Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed |
| 72 | S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed |
| 73 | M&L Preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 74 | M&L Preparation of old steel surface of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 75 | M&L Preparing old surfaces of plastered wall by complete removal of existing treatment and applying two coats of oil bound distemper complete all as specified and as directed |
| 76 | M&L PCC 1:2:4, Type B-2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed |
| 77 | M&L Excavating over areas, n.exc 1.5 m deep and getting out soft/loose soil complete all as specified and as directed |
| 78 | M&L Removing excavated material exc. 1.50 km but n.exc. 5 km and depositing where directed inside the MD land complete all as specified and as directed |
| 79 | Excavating in post holes (or similar holes) each n.exc 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering and removing surplus soil to a distance n.exc 50m and making good surface as in hard / dense soil complete all as specified and as directed |
| 80 | S&F 40mm thick PUF panels with EPS stuck to 0.50mm thick plain GI sheet at bottom and corrugated GI sheet at top suitably placed in false ceiling grid made of Aluminium/G.I./M.S. complete all as specified and as directed. |
| 81 | M&L 12mm thick Toughened glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and as directed |
| 82 | S&F Wall to Glass connecting patch (SS) to fix toughened glass at top and bottom complete all as specified and as directed |
| 83 | S&F Glass to Glass connecting patch (SS) to fix toughened glass at top and bottom complete all as specified and as directed |
| 84 | S&F Big L patch (SS) to fix toughened glass door at top complete all as specified and as directed |
| 85 | S&F Over panel patch (SS) to fix toughened glass door at top complete all as specified and as directed |
| 86 | S&F Bottom patch (SS) to fix toughened glass door at bottom complete all as specified and as directed |
| 87 | S&F Lock panel patch (SS) in toughened glass door at bottom complete all as specified and as directed |
| 88 | S&F H-type handle SS for glass door, hole to hole length 1 feet and overall length 1.5 feet complete all as specified and as directed |
| 89 | S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed. |
| 90 | S&F in repair Stainless steel brackets, knobs for curtain rods (Curtain rod dia 20mm) fixed to wall with SS screws etc. complete all as specified and as directed |
| 91 | S&F transparent corrugated polycarbonate sheet 6 mm thick having as in Roof covering /cladding to wall fixed with self tapping screws complete all as specified and as directed. |
| 92 | S&F 5mm thick Figured glass, pinhead type in squares n.exc 0.5 sqm each pane for ventilator (louver type) complete all as specified and as directed. |
| 93 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 |
| 94 | M&L for applying Two coats of exterior emulsion paint UV resistance, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) and including priming coat of exterior primer applied after complete removal of existing treatment over old plastered surface complete all as specified and as directed. |
| 95 | Demolition of RCC concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed |
| 96 | S&F 4mm thick PVDF coated Aluminium Composite Panel (ACP sheet) of any colour and texture for exterior walls cladding/ building facade along with aluminium section, bonding tape, Dow corning silicone sealant etc fixed to MS frame work including fasteners, concealed screws, nuts, bolts and other items required for connecting aluminium sheet, blind rivets complete all as per manufacturers instructions and as directed.Note: (a)ACP sheet shall be UV resistant, anti-corrosive and durable . (b)The MS frame work for ACP cladding shall be measured and paid separately(c) The unit rate quoted shall be inclusive of pre-formed gasket to the horizontal and vertical joints, structural silicon joint and necessary fixing accessories and scaffolding at any height of installation(d) For payment purpose panel area shall be measured (on one side only) |
| 97 | Demolition of Concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 98 | M&L Hardcore (broken stone or boulders) of gauge n.exc. 63 mm, deposited, spread and leveled in layers n.exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed |
| 99 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed. |
| 100 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed. |
| 101 | M&L 100mm thick PCC 1:2:4, Type B-1 using 20mm graded aggregate as in sub floors, sub bases, floors and pavings etc complete all as specified and as directed |
| 102 | S&F On site 2000 litres LLDPE septic tank for 20 users, conventional type, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as specified and as directed |
| 103 | M&L PCC 1:3:6, Type C-2 using 40mm graded aggregate in foundations, filling and mass concrete etc complete all as specified and as directed. |
| 104 | M&L Brickwork with fly ash bricks in one brick thick honey-comb walling, old size bricks built in cement mortar 1:4 complete all as specified and as directed. |
| 105 | M&L for Loose filling of broken bricks of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and as directed |
| 106 | M&L Providing precast cement concrete (PCC 1:2:4 type B-1) using 20mm graded stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar CM 1:4 complete all as specified and as directed |
| 107 | M&L TMT bars 6-8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed |
| 108 | Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in soft and loose soil complete all as specified and as directed |
| 109 | M&L Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and as directed |
| 110 | S&F 150mm dia Double Wall Corrugated (DWC) HDPE pipe of approved make ISI marked polythene with smooth internal wall and profiles external surfaces for non pressure for sewage laid in trenches and jointed complete all as specified and as directed |
| 111 | M&L for Cement concrete bed in 1:3:6, Type C-2 to drain pipes including packing under, and haunching against the sides of 150mm bore of pipes after they are laid and tested complete all as specified and as directed |
| 112 | M&L Rendering 15 mm thick cement plaster on fair faces of brickwork in CM 1:4 finished even and smooth without using extra cement with integral water proofing compound complete all as specified and as directed (WPC shall be paid separately) |
| 113 | M&L PCC 1:4:8, Type D-2 using 40mm graded aggregate in foundations, filling and mass concrete etc complete all as specified and as directed |
| 114 | Supply only integral water proofing compound for plastering work |
| 115 | M&L PCC 1:2:4, Type B-1 using 20mm graded aggregate as in copings, water troughs and the like including weathering, slightly rounded or chamfered angles throating etc complete all as specified and as directed.Note: The rates include for use of formwork (straight or curved).Reinforcement shall be measured separately. |
| 116 | M&L PCC 1:2:4, Type B-2 using 40mm graded aggregate in surface channels and drains complete all as specified and as directed |
| 117 | M&L Extra for forming fair finished drain or channel 90cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and as directed |
| 118 | M&L Providing precast cement concrete 1:2:4, louvers and jallies, 50mm thick (measured solid) type B-0 using 12.5mm graded aggregate and set in cement mortar 1:4, including all mouldings but excluding frame complete all as specified and as directed. |
| 119 | M&L Preparing new surfaces of plastered wall and applying two coats of cement based paint complete all as specified and as directed |
| 120 | Cutting holes in brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and as directed |
| 121 | Taking down carefully copper/Aluminum point wiring (light, fan. socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets , light fitting etc and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed. |
| 122 | M&L for Point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade, FRLS cable and incl PVC conduit with accessories in wall/roof/ceiling/hangar steel frames etc incl Modular terminal boxes fabricated with 1.6mm MS sheet concealed to walls covered with plastic laminated top cover 2.8mm fixed with cadmium plated iron screws etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for |
| 123 | (a) One light point/fan/bell point controlled by one switch |
| 124 | (b) All as per item No. 122(a) here in before but for One 3 pin socket out 5 amp on the same board |
| 125 | (c) All as per item No. 122(a) here in before but for one switch socket outlet 3 pin 5 Amps on independent board |
| 126 | All as per Sl No 122 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently |
| 127 | S&F modular switch 1 way 6 Amps, 1 module complete all as specified and as directed. |
| 128 | S&F modular switch 1 way 16 Amps, 1 module complete all as specified and as directed. |
| 129 | S&F modular socket outlet multipurpose 2/3 pin 6 amps, 2 module complete all as specified and as directed. |
| 130 | S&F modular socket outlet multipurpose 2/3 pin 6/16 amps, 2 module complete all as specified and as directed. |
| 131 | S&F Modular Bell push 6A 1 module complete all as specified and as directed. |
| 132 | S&F White cover plate with frame, 1 module complete all as specified and as directed. |
| 133 | S&F white cover plate with frame, 3 Module complete all as specified and as directed. |
| 134 | S&F white cover plate with frame, 6 Module complete all as specified and as directed. |
| 135 | S&F white cover plate with frame, 8 Module complete all as specified and as directed. |
| 136 | S&F Metal flush box 1/2 module complete all as specified and as directed. |
| 137 | S&F metal flush box 3 module complete all as specified and as directed. |
| 138 | S&F metal flush box 6 module complete all as specified and as directed. |
| 139 | S&F metal flush box 8 module complete all as specified and as directed. |
| 140 | S&F Bell AC. 230 volts, single pole complete all as specified and as directed. |
| 141 | S&F electronic modular fan regulator 230 volts, step type socket type, hum free 120 watt 2 Module complete all as specified and as directed. |
| 142 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, complete all as specified and as directed. |
| 143 | S&F ceiling rose, surface type Bakelite 65x55mm 3 terminal complete all as specified and as directed. |
| 144 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed |
| 145 | M&L for BLDC energy efficient wall mounted fan 400 mm sweep single phase 230 volts including fixing arrangement on wall/angle complete all as specified and as directed.. Make/Model : Atomberg or any other equivalent approved make. |
| 146 | S&F exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 300mm complete all as specified and as directed. |
| 147 | S&F LED luminaries 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 148 | S&F of factory made powder coated distribution board VTPN, 3-ph,4 way double door,415volts,50Hz including bus bar capacity not less than 200Amps , Neutral bar, standard DIN rail, earth bar with a provision of MCCB TPN as incomer flush to wall/surface conforming to IS and making good of destructed surface including taking down old one complete all as specified and as directed. |
| 149 | S&F replacement factory made powder coated distribution board SPN 8 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and as directed. |
| 150 | S&F MCCB 4 pole, 63 Amp ultimate breaking capacity 16 KA complete conforming to IS complete all as specified and as directed. |
| 151 | S&F MCB SPN 32 Amp , 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and as directed. |
| 152 | S&F single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and as directed. |
| 153 | M&L for Sub main wiring for circuit complete with 2 X 6 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and incl suitable size PVC Casing capping and accessories complete fixed surface to wall/roof/ceiling etc and incl 1 X 6 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc and complete all as specified and as directed including taking down old u/s one. |
| 154 | M&L for Sub main wiring for circuit complete with 2 X 4 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and incl suitable size PVC Casing capping and accessories complete fixed surface to wall/roof/ceiling etc and incl 1 X 4 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc and complete all as specified and as directed including taking down old u/s one.: |
| 155 | M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick buried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth wire 4 mm dia by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magnesium Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as specified and as directed. |
| 156 | Supply, testing & installation of electric storage water heater (geyser) of capacity 25 Ltrs, BEE five star rated, 230Volts, AC,50Hz, comprising of heating element 2000 watts, puff insulation, both power indicating LED lamp and heating indicating LED lamp, actual stdg loss & reheating time, adjustable thermostat(Temperature range),Glass Coated Heating Element(to prevent water scale formation on elecement),Temperature Control Knob, Anode Rod(to protect tank from corrosive elements),Thermal Cutout, Safety Valve(The safety valve shall be designed to automatically relieve pressure and discharge water in case the pressure overshoots the preset limits),necessary suitable 3 core copper cable, suitable plug top complete all as specified and as directed. |
| 157 | S&F of PVC connection pipe for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 600 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe complete all as specified and as directed |
| 158 | S&F of Stop valves, 15 mm Bore of pipe in mm fancy type, chromium plated , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed incl taking down old u/s stop valve. |
| 159 | S&F 1000 Ltr Capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed including taking down old one |
| 160 | M&L for Making connection of PP-R distribution branch with PP-R main of following sizes Bore of pipes in 16 to 40 mm by providing and fixing tee including cutting and making fusion joint etc. complete all as specified and as directed including taking down old one |
| 161 | S&F Ball brass valves of 25 mm size, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and complete all as specified and as directed including taking down old one |
| 162 | Supply and lay 3 layer (Inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-16) and PP-R plain fittings in trenches/ walls/callings or laying in floors complete of size outer dia 32 mm including all fittings and taking down old one |
| 163 | Supply and lay 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-16) and PP-R plain fittings in trenches/ walls/ceilings or laying in floors complete of size outer dia 25 mm including all fittings including taking down old one, complete all as specified and as directed. |
| 164 | S&F PPR Gate Valves (Brass Insert) of 25 mm bore. complete all as specified and as directed including taking down old one |
| 165 | Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. |
| 166 | Supply & filling in riddling sand for cushioning of cable in trenches including spreading, leveling, complete all as specified and as directed. |
| 167 | Supply and lay Bricks common fly ash building bricks, sub-class ‘B’ of size 23x11.5 x7.5cm for cable protection cover. complete all as specified and as directed. |
| 168 | Supply and lay UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100V with screened aluminium conductor of size 3.5 core 95 sqmm, complete all as specified and as directed including taking down old u/s cable. |
| 169 | Supply and lay UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100V with screened aluminium conductor of size 3.5 core 35 sqmm, complete all as specified and as directed including taking down old u/s cable. |
| 170 | Supply Install, and commissioning LT feeder pillar outdoor type IP-65 made out of 3.15 mm thick MS sheet and angle Iron frame work, cubicle type with copper bus bars and with suitable mounting plate, frame and canopy, confirms to IEC61439-2 with following accessories suitable for incoming/outgoing arrangements including taking down old u/s one :- (a) MCCB with extended rotary handle and spreader link 160 A 35kA 4 pole - 01 No (b) MCCB 63 Amps- 02 No (c) MCB TPN 40 Amp-01 No (d) MCB SPN 6-32 Amp-01 No (e) Digital panel meter for volt Amp/Volt/KWH&PF - 01 No (f) LED indicating lamp set- 01 Set of three (g) Angle size 50x40x6MM suitable for LT Panel Load |
| 171 | M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick buried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with galvanized iron strip 32x6mm as earthing lead by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magnesium Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail