| 1 | M&L for attending day to day breakdown complaints of any nature in low tension line after receiving the complaint from complaint cell/ JE concerned and rectifying the same as soon as possible by checking the LT panel, MCCB, cable from the source to the end by meggering the cable or any means complete all as specified and directed. This work includes all minor repairs i.e Note : If any major materials are used will be measured and paid separately in appropriate items below |
| 2 | M&L for attending day to day breakdown complaints of any nature in high tension line after receiving complaint from complaint cell/ JE concerened and rectifying the same as soon as possibble by checking the VCBs, RMUs, Cables, Four pole/ Two pole structures from source to the end by meggering the cable or any means complete all as specified and directed. Note : If any major materials are used will be measured and paid separately in appropriate items below. |
| 3 | Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in looses/soft soil complete all as specified |
| 4 | Returing filling in incl spreading leveling, watering and well ramming in layer not less than 25 cum each layer all as specified. |
| 5 | Removing excavated material to a distance not exc 50M and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified |
| 6 | Supply and laying double wall corrugated HDPE pipe 50mm outer dia for protection of UG cable complete all as specified |
| 7 | M&L PCC 1:4:8 type D 2 using 40 mm graded stone aggregate for filling of pole & stay complete all as directed |
| 8 | M&L PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for filling of pole & stay complete all as directed |
| 9 | M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for copining of pole complete all as directed |
| 10 | M & L for tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 50 mm bore including removing the rusted old one complete all as specified and directed. |
| 11 | M & L for tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 80 mm bore including removing the rusted old one complete all as specified and directed. |
| 12 | M & L for tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 100 mm bore including removing the rusted old one complete all as specified and directed. |
| 13 | Taing out old usserviceable PCC pole of any size and supply and fixing in repairs Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l02mm x 279mm at bottom, class 10 and erecting in position all as specified and directed with shifting of conductors and insulators including painting the exposed portion with two coats of weather proof paint complete, all as specified and directed. |
| 14 | S & F in replacement of Cross arm, bracings, supports , clamps and back plate fabricated from structural steel section, including nut , bolts , washers, welding , bendings cold or hot, drilling hole for both in any shape or size as indicated or directed and inclusive of one prime coat, one under coat and one finishing coat of paint incl taking down the old unserviceable cross arms complete all as directed. |
| 15 | Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following size,including cable lugs & Glands etc complete, all as specified and directed :- (a) 10 Sqmm 2 Core. |
| 16 | (b) 10 Sqmm 4 Core. |
| 17 | (c) 16 Sqmm 4 Core. |
| 18 | (d) 25 Sqmm 3.5 Core. |
| 19 | (e) 35 Sqmm 3.5 Core |
| 20 | M/L for replacement of Earthing complete with GI earth plate 60x60cmx6mm thick electrode and using galvanised iron strip 32 x 6 mm as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point all as specified and as directed by Engr-in-charge. |
| 21 | Supply and fixing of moulded case circuit breaker Four pole 100/63Amps 16 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 22 | Supply and fixing of moulded case circuit breaker Four pole 160 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge |
| 23 | Supply and fixing of moulded case circuit breaker Four pole 200 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge |
| 24 | Supply and fixing of digital voltmeter 0 to 500 volts 96 x96mm flush type in LT Panels incl taking out the old unserviceable complete all as specified and directed. |
| 25 | Supply and fixing of digital ammeter range as per existing 96 x96mm flush type in LT panels incl taking out the old unserviceable complete all as specified and directed. |
| 26 | Supply and fixing of LT current transformer ratio from 200/5 Amps or 100/5 or 400/5 in LT panels incl taking out the old unserviceable complete all as specified and directed. |
| 27 | Supply and fixing selector switch of voltmeter/ammeter in LT panel boards incl taking out the old unserviceable complete all as specified and directed. |
| 28 | Supply and fixing indicator assembly (RYB) LED type in LT panel boards incl taking out the old unserviceable complete all as specified and directed. |
| 29 | M&L for painting to LT panels of any size with two coats of Smoke Gray paint over a coat of red oxide primer outerside and two coats of off white paint over a coat of red oxide primer internally complete all as specified and directed by Engr- in-Charge. Note: 1. Before painting the contractor will ask for a shut down of the recpective feeder from the JE. 2. While painting of the panels protection of MCCB's and MCB's to be taken care of by the contractor. Any damage occured during the painting will be bear by the contractor. |
| 30 | S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 2 core XLPE armoured aluminium conductor cable of size 6-16 sqmm complete |
| 31 | S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 16-50 sqmm complete |
| 32 | S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm complete |
| 33 | S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 150 to 185 sqmm complete |
| 34 | S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for END termination kit of heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 150 to 185 sqmm complete |
| 35 | S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for END termination kit of heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 240 to 300 sqmm complete |
| 36 | Boring of holes horizontally for laying of 80mm dia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed. |
| 37 | Supply and fixing Aluminium tube terminal/ lugs of undermentioned size complete (a) 10 to 25 Sqmm |
| 38 | (b) 35 to 50 Sqmm |
| 39 | (c) 70 to 120 Sqmm |
| 40 | (d) 150 to 185 Sqmm |
| 41 | S & F in replacement of old UNSV. Cable loop box with SMC Junction box shock and rust proof , rot/termite resistance, tamper proof, with necessary pole mounting arrangements FR type ( (270mm x 225mm x 135mm) with in-built /housed terminal for 04 pole wire termination and MCB din-rail mounted , hinged door with locking arrangements incl necessary Galvanised iron clamps, bolts/nuts suitable to hold/accommodate to the exisitng pole(any type)/ bldg etc by removing the exisiting electrical connections and reconnecting back the same cable complete all as specified & directed (Note : any glands/lugs/lock-pads reqd for the same is within the the rates quoted) |
| 42 | Supply and fixing MCB SPN 32 amp rating 240V, 10KA 'C' curve and current carrying capacity complete with connection testing and commissioning. |
| 43 | Supply and fixing MCB TPN 63 amp rating 240V, 10KA 'C' curve and current carrying capacity complete with connection testing and commissioning. |
| 44 | Supply and fixing connectors of two pole/three pole/ fourpole complete all as specified and directed |
| 45 | S & F in repairs cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. |
| 46 | S & F in repairs cable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. |
| 47 | S & F in repairs cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. |
| 48 | S & F in repairs cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. |
| 49 | S & F in repairs cable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. |
| 50 | S & F in repairs cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. |
| 51 | Supply & Lay , testing and commissioning in repairs XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 95 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing in different locations / areas complete |
| 52 | Repairing / Servicing the Air break isolating switch HT 33 KV 400 Amps by replacing the defective major spares including provn of minor bolts nuts etc all as specified. Note :- Major spare will be measured & paid seperately under relevant item of Sch'A' item No. 50 |
| 53 | Supply only 33 KV Airbreak switch spares all as directed. (a) Male contact/moving Contact Blade |
| 54 | (b) Female contact/Fix Contact Jaw |
| 55 | (c) Rotating contactor pipe 400 A |
| 56 | (d) MS jumper carrier |
| 57 | (e) Back Connector plate |
| 58 | Repairing / Servicing the Air break isolating switch HT 11 KV 200 Amps by replacing the defective major spares including provn of minor bolts nuts etc all as specified. Note :- Major spare will be measured & paid seperately under relevant item of Sch'A' item No. 52 |
| 59 | Supply only 11KV Airbreak switch spares all as directed.(a) Male contact/moving Contact Blade |
| 60 | (b) Female contact/Fix Contact Jaw |
| 61 | (c) Rotating contactor pipe 200A |
| 62 | (d) MS jumper carrier |
| 63 | (e) Back Connector plate |
| 64 | Supply and filling of fresh transformer power oil of BDV not less than 50 KV for topping up of reduced level of transformer due to evaporation/ leakage/losses due to dehydration in distribution 11 /33 KV transformer /Distribution transformer 25KVA to 1.6MVA or for replacement complete including removing of old unservicable transformer oil all as specified and directed. |
| 65 | Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 25KVA 33/0.43KV transformer. |
| 66 | Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 1.6MKVA 33/11KV transformer. |
| 67 | Supply and fixing of fuse wire tinned copper of different capacity as per ground requirement complete all as specified and directed.. |
| 68 | M&L for cable fault locator vehicle mounted to locate fault at any type of location with one fault locate at a time complete all as specified and directed by Engr-in-Charge |
| 69 | M & L for Cutting and trimming of tree branches 5 mtr all around of any size which is coming over the two/four pole structure of 33 KV line by using required tools and plants incl removing trimmed tree branches. (Note : Each cleaning will be measured and paid separetely) |
| 70 | M & L for Cutting and trimming of tree branches 5 mtr all around of any size which is coming over the two/four pole structure of 11 KV line by using required tools and plants incl removing trimmed tree branches. (Note : Each cleaning will be measured and paid separetely) |
| 71 | S & F in repair horn gap fuse metal Spare Parts of 11 kv 200 Amps including all connected accessorises complete all as specified and as directed |
| 72 | S & F in repair horn gap fuse metal Spare Parts of 33 kv 400 Amps including all connected accessorises complete all as specified and as directed |
| 73 | S&F in repair 33 KV disc insulator polymer type with hardware fittings complete all as specfied and directed |
| 74 | S&F in repairs of 33 KV Polymer type post insulators complete all as specfied and directed |
| 75 | S&F in repairs of 11 KV Polymer type post insualtors complete all as specified and directed |
| 76 | S&F in repairs power aluminium bolted type connectors to be fixed on jumpers/aluminum conductors/AB conductors of any size complete all as specified and directed |
| 77 | S&F in repairs of AB conductor of size 95 Sqmm with colour code (RYB) as required on ground for MRS structure complete all as specified and directed |
| 78 | Taking out old UNSV XLPE/PVC insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor from trenches, from poles/walls etc cross sectional area for following sizes complete, all as specified and directed :-(Excavation/Earth wk will be measured and paid seperately) (a) 10 Sqmm to 16 sqmm 4 / 2 Core |
| 79 | (b) 25 to 50 Sqmm 3.5 Core/4 core. |
| 80 | (c) 50 to 185 Sqmm 3.5 Core/4 core. |
| 81 | Relaying of serviceable U/G cable retrived from site of size 10 to 16 sqmm 2/4 core ( Cable protection pipe /sand brick,jointing kit,cable lugs etc will be measured and paid seperately) |
| 82 | Relaying of serviceable U/G cable retrived from site of size 25 to 35 sqmm 2/3.5/4 core ( Cable protection pipe /sand brick,jointing kit, cable lugs,etc will be measured and paid seperately) |
| 83 | Relaying of serviceable U/G cable retrived from site of size 50 to 185 sqmm 2/3.5/4 core ( Cable protection pipe /sand brick,jointing kit, cable lugs etc will be measured and paid seperately) |
| 84 | Supply and fixing FRP fencing made up with using FRP rod 12 mm dia, channel size 50x24x4 mm box section 50x25 mm I Section 38x15x3 mm and square box section 50x50mm in post embedded in plain cement concrete (1:4:8) type D2 using 20 mm graded stone aggrerate (45x45x45cm) including necessary excavation and earthwork at 1.25 m C/C with height of fencing 2 m from GL including entracne gate of size 1mx2m of same material MS aldrop bolt 300mm long , 150 mm size pressed steel handles and 2 Nos tower bolts MS hinges as required etc complete all as specified and directed Make : Sintex/ Sanlec or equivalent as approved by GENote :- Verticle posts and rail section shall be manufactured of fibre glass reinforcement min 45% and formulation of polystrbased thermoset resigns. |
| 85 | Painting of MRS 33KV Yard pole stucture consisting of 8 Nos pole(metal structure) 11 M height, 4 No GODS, 4 set Fuse with channels,1Bus bars 1 No LA etc with all connected clamps,supports etc by preparing the surface and applying two coat of Aluminium syntheti enamal paint over a coat of primer as per colour code all as specified and as directed |
| 86 | Painting of MRS 11KV Yard pole stucture consisting of 8 Nos pole(metal structure) 11 M height, 6 No GODS, 3 set Fuse with channels,1Bus bars 1 No LA etc with all connected clamps,supports etc by preparing the surface and applying two coat of Aluminium syntheti enamal paint over a coat of primer as per colour code all as specified and as directed |
| 87 | M&L for painting to 11Kv Breakers of any size with two coats of Smoke Gray paint over a coat of red oxide primer outerside complete all as specified and directed by Engr- in-Charge. Note: 1. Before painting the contractor will ask for a shut down of the recpective feeder from the JE. 2. While painting of the 11KV Breaker panels protection of Switches to be taken care of by the contractor. Any damage occured during the painting will be bear by the contractor. |
| 88 | Painting of four pole stucture consisting of 4 Nos pole(metal structure) 11 M height, 3 no GOS, 1 set Fuse with channels,1Bus bars 1 No LA etc with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code all as specified and as directed |
| 89 | Painting of two pole stucture consistig of 2 Nos PCC pole 11 M height, 1 no GOS, 1 set support insulators with channels, with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code to the metal structure and cement paint to the PCC structures all as specified and as directed |
| 90 | S & F in repairs lighting arrestor Zinc oxide gap less type , station class suitable for 11 KV / 65 KA complete with all fittings all as specified and directed. |
| 91 | S & F in repairs lighting arrestor Zinc oxide gap less type , station class suitable for 33 KV / 65 KA complete with all fittings all as specified and directed. |
| 92 | M & L for removing vegitation, grass, scrubs and bushes growing in Sub station yard along with fancing by mannually / mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately. |
| 93 | S & F in repairs insulating rubber mat ISI marked of size 1 m x 2 m x19mm suitable for 11 KV at 33 KV MRS |
| 94 | Supply/ Lay dry river sand /m -sand in trenches for cable protection all as directed.Note : Punned thickness only will be measured & Paid |
| 95 | M & L for graded coarse aggregate (broken stone or boulders) of size 40 mm in sub - station yard for laying all as directed and specified. |
| 96 | Taking down carefully the existing 33KV/433 KV distribution transformer of capacity 25 KVA by disconnecting HT overhead connection/underground cables and earth strips etc. from any substation / locations using suitable capacity of crane or by any other method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the tranformer after repairs and testing of transformer; transportation to site and unloading including placing at given position and re-commissioning complete all as specified and directed by Engr-in-charge. Note : All the T&P required for disonnection, connection, loading and loading including necessary petty items like bolts, nuts etc will be arranged by the contractor and rates for the same deem to be included in the rates quoted. |
| 97 | Taking down carefully the existing 33KV/11KV distribution transformer of capacity 1.6MVA by disconnecting HT overhead connection/underground cables and earth strips etc. from any substation / locations using suitable capacity of crane or by any other method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the tranformer after repairs and testing of transformer; transportation to site and unloading including placing at given position and re-commissioning complete all as specified and directed by Engr-in-charge. Note : All the T&P required for disonnection, connection, loading and loading including necessary petty items like bolts, nuts etc will be arranged by the contractor and rates for the same deem to be included in the rates quoted. |
| 98 | M & L for repairs toTransformer step down 33KV/0.433 KV any type of capacity 25 KVA, after dismantling the transformer body carefully, opening the top cover of Transformer for inspection /repair, drain out the transformer oil from the tank complete, taking out the core and winding assy by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, renewal/replacement of u/s rubber bushes and washers , replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, warnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, Painting of complete transformer body from outside and inside by weather proof type using spray gun, Marking of MES/SM Number etc, replacement of conservator tank glass, re-intalling the core and winding inside properly, making the all connection with suitable copper lugs, refilling of dehydrated transformer oil including dehydration, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and directed by Engr-in-Charge. Note :- Winding wire including labour for making of coils and LT/HT bushes will be measured & paid seperately. |
| 99 | All as per Srl item No 98 above but of capacity 33 KV/11 KV, 1.6MVA complete all as directed. |
| 100 | Material and labour for replacement of brass terminal rod with nuts,bolts washers & bushings suitable for 33KV HT side of the transformer of any make and capacity from 25 KVA complete. |
| 101 | Material and labour for replacement of brass terminal rod with nuts,bolts washers & bushings suitable for 33KV HT side of the transformer of any make and capacity from 1.6MVA complete. |
| 102 | All as per item No 101 above but LT side. |
| 103 | All as per item No 101 above but 11KV HT side. |
| 104 | Material and labour for repalcement of gasket for complete transformer all as specified and directed |
| 105 | M & L for painting using spray painting the outer surface of the transformer with one coat of weather proof paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing the MES/SM No with white enamelled paint all as directed for capacity of transformer 1.6 MVA complete |
| 106 | M & L for painting using spray painting the outer surface of the transformer with one coat of weather proof paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing the MES/SM No with white enamelled paint all as directed for capacity of transformer 25 KVA 33/0.43KV complete |
| 107 | M&L for replacement off load tap changer for distribution transformer of any make and capacity of 25 KVA 33/0.43KV |
| 108 | M&L for replacement off load tap changer for distribution transformer of any make and capacity of 1.6MVA 33/11KV |
| 109 | M&L for super enamelled copper conductor wire of suitable gauge and size including making suitable coil bobbins as per existing size and shape with proper insulating materials, spacers, warnishing as per required grade and insulatin and assembling on core, heating the same in oven as per standard procedure at appropriate temerature to obtained desired insulatin level for the power/ distribution transformer of any capacity / any make complete all as directed. |
| 110 | Dismantling and disconnecting of unserviceable parts of Tata Mobile 207 Vehicles reinstalling after repair/replacement of unservice-able parts complete to entire satisfaction of Engr-in-Charge. NOTE: Spare parts required to be replaced shall be measured and paid separately as mentioned here-in-below. |
| 111 | Engine oil |
| 112 | Oil filter element |
| 113 | Diesel filter element (set of two) |
| 114 | Air filter |
| 115 | Brake leather |
| 116 | Front wheel bearing |
| 117 | Coolant |
| 118 | Front shokers |
| 119 | Brake oil |
| 120 | Door lock driver side |
| 121 | Door lock rear door |
| 122 | Counter Shaft |
| 123 | Top gear |
| 124 | Gear Bearing |
| 125 | Synchronizing ring |
| 126 | Gear Oil |
| 127 | Gear Oil Seal |
| 128 | Gear Jain Kit |
| 129 | Fan Belt |
| 130 | Tie rod end |
| 131 | Bush kit complet |
| 132 | Ball joint assembly |
| 133 | Diesel pipe |
| 134 | Yoke and teeth |
| 135 | Shaft Nuts and Bolts |
| 136 | Mirror rolling machine |
| 137 | Engine mounting |
| 138 | U.J cross |
| 139 | Fly wheel Ring |
| 140 | Front Mirror with rubber beading |
| 141 | Head light assembly complet with tube |
| 142 | Main leaf spring |
| 143 | Leaf spring 2nd No |
| 144 | Leaf Spring 4th No |
| 145 | Leaf Spring clump |
| 146 | Nuts and Bolts with washer |
| 147 | Tyre rotation |
| 148 | Cover Inner and outer of size 7.00-16LT |
| 149 | Wiper Arm & Blade |
| 150 | Alternator rectifier |
| 151 | Alternator rotor assy |
| 152 | Side view Mirror |
| 153 | Front indicator assembly |
| 154 | Rear indicator assembly |
| 155 | Ignition cum lock switch |
| 156 | Cluch cylinder assy upper |
| 157 | Clutch cylinder assy lower |
| 158 | Master cylinder assy |
| 159 | Clutch Plate |
| 160 | Pressure plate assy |
| 161 | Clutch release bearing |
| 162 | Dismantling of four wheels by greasing of four wheels including replacement of oil seal and reassembling complete all as directed. |
| 163 | Repair of seat complete including replacement of best quality Rexign, U foam & spring complete all as directed. |
| 164 | Alignment of wheel completely by computerized machine. |
| 165 | Cleaning of radiator assy complete by opening both tanks & cleaning the fins of the radiator by chemical and stopping the leakage by gas welding wherever required |
| 166 | Repair to FIP pump by over hauling the FIP and replacing all the spares of the FIP with the new spares and testing complete on machine all as directed. |
| 167 | Dismentling of Fuel tank assy complete from the vehicle and cleaning by pressure and refitting. |
| 168 | Dismantling and disconnecting of U/S parts of two wheelers Honda/Platina Reinstalling after repair/replacement of U/S parts complete to entire satisfaction of Engr-in-Charge. NOTE: Spare parts required to be replaced shall be measured and paid separately as mentioned here-in-below. |
| 169 | Carburetor assy |
| 170 | Chain and chain sprocket. |
| 171 | Spark plug |
| 172 | Clutch plate |
| 173 | Shock absorber |
| 174 | Lock set complete |
| 175 | Side Looking Mirror |
| 176 | Kilometer cable |
| 177 | Head Light Tube |
| 178 | Back Light Complete |
| 179 | Break shoe Front and rear |
| 180 | Clutch cable complete |
| 181 | Accelerator cable complete |
| 182 | Engine oil |
| 183 | Dismantling and disconnecting of unserviceable parts of EICHER Model No 10.75 Vehicles re-installing after repair/replacement of unserviceable parts complete to entire satisfaction of Engr-in-Charge.NOTE: Spare parts required to be replaced shall be measured and paid separately as mentioned here-in-below. |
| 184 | Engine Oil CRB plus 20W40 |
| 185 | Oil filter element |
| 186 | Fuel filter element (set of two) |
| 187 | Door Handle with lock assembly |
| 188 | Door Handle |
| 189 | Coolant |
| 190 | Retreading of Tyres |
| 191 | Front Indicating light assly with bulb |
| 192 | Wheel bearing |
| 193 | Wheel cylinder assy |
| 194 | Break leather |
| 195 | Side view mirror |
| 196 | Head light assy complete with bulb (Halogen type) |
| 197 | Bumper corner |
| 198 | Self Starter Assy |
| 199 | Window glass with beading |
| 200 | Alternator carbon bush |
| 201 | Rectifier assy. |
| 202 | Alternator bearing |
| 203 | Back light assy. complete |
| 204 | Indicator assy. |
| 205 | Cutout 12 volts |
| 206 | Flasher |
| 207 | Main leaf spring |
| 208 | Nuts and Bolts with washer |
| 209 | Centre Bolts |
| 210 | U- Bolts |
| 211 | Wiper Arm & Blade |
| 212 | Ignition cum lock switch |
| 213 | Cluch cylinder assy upper |
| 214 | Cluch cylinder assy lower |
| 215 | Master cylinder assy |
| 216 | Cluch Plate |
| 217 | Pressure plate assy |
| 218 | Cluch release bearing |
| 219 | Fan Belt |
| 220 | Tie rod end |
| 221 | Diesel pipe |
| 222 | UJ cross |
| 223 | Top Gear |
| 224 | Gear Bearing |
| 225 | Synchronizing Ring |
| 226 | Fuel tank cleaning |
| 227 | Gear oil |
| 228 | Gear oil seal |
| 229 | Gear Cain Kit |
| 230 | Main Gear shaft |
| 231 | Repair of self starter by replacing of self bendex, carbon bush set, solenoid switch etc complete. |
| 232 | Dismantling the load springs and refitting after repair and giving suitable tensioning complete all as directed. |
| 233 | Dismantling of four wheels complete by greasing of four wheels including replacement of oil seal and re-assembling complete. |
| 234 | Setting of wheel alignment and setting of brake system including filling of brake fluid in master cylinder kit. |
| 235 | Repair of seat complete including replacement of best quality Rexign, U foam & spring complete all as directed. |
| 236 | Overhauling, greasing of King pin including replacement of oil seal complete. |
| 237 | Denting of vehicle, including welding wherever required |
| 238 | Dismentling of Fuel tank assy complete from the vehicle and cleaning by pressure and refitting. |
| 239 | Supply and fixing in replacement of maintenance free battery 12 volt 92 Ah including battery leads and initial charging of battery. |
| 240 | Supply and fixing in replacement of maintenance free battery 12 volt 60 Ah including battery leads and initial charging of battery. |
| 241 | Dismantling and disconnecting of unserviceable parts of Maruti swift Dzire Veh BA No: 23B -1318847X and re-installing after repair/replacement of unserviceable parts complete to entire satisfaction of Engr-in-Charge.NOTE: Spare parts required to be replaced shall be measured and paid separately as mentioned here-in-below. |
| 242 | Engine oil |
| 243 | Oil filter element |
| 244 | Fuel filter element (set of two) |
| 245 | Brake oil |
| 246 | Coolant |
| 247 | Cover Inner and outer of size 165/80R14 Please Enable Macros to View BoQ information |