| 1 | Construction of Soakage wells of size 1.80 Mtr dia x3.00m depth excavation in any types of soil, foundation in PCC 1:3:6 walls of honeycomb masonry with brick work all as shown in CEDZ TD drawing......... top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slabs in M-25/SFRC covers, interconnecting pipes of RCC/DWC complete filled with brick bats including demolition of existing old soakage well of any size and refill the same up to the existing ground level complete all as as specified and directed complete all as directed. |
| 2 | M&L Loose filling with broken bricks of gauge 80 to 150 mm in soakage pits , sokage wells complete all as specified. |
| 3 | S&F PVC(SWR) pipes, 75 mm external dia double socketed in any length with rubber joints, fixed to walls etc with MS clamps including dismantling of cast iron, AC / PVC pipes including all fittings and accessories of 100/75 mm dia and in any position complete all as specified. MAKE: SUPREME, FINOLEX, PRINCE . |
| 4 | S&F PVC (SWR) bends suitable for 75 mm external dia with or without access door complete all as specified |
| 5 | S&F PVC (SWR) junction single, (single T&Y) equal or unequal with or without access door confirming to IS: 14735, suitable for PVC soil waste discharge pipe of 75 mm dia Complete all as specified and as directed. |
| 6 | S&F PVC (SWR) pipes, 110 mm external dia, type-B, ISI marked (IS:13592) double socketed in any length with rubber ring joints, fixed to walls etc with ms clampsMS clamps including dismantling of cast iron, AC / PVC pipes including all fittings and accessories of 100/75 mm dia and in any position complete all as specified. MAKE: SUPREME, FINOLEX, PRINCE . |
| 7 | S&F PVC (SWR) bends suitable for 110 mm external dia with or without access door complete all as specified |
| 8 | S&F PVC (SWR) junction single, (single T&Y) equal or unequal with or without access door confirming to IS: 14735, suitable for PVC soil waste discharge pipe of 110 mm dia Complete all as specified and as directed. |
| 9 | S&F in replacement of broken cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, fixed to wall with clamps etc. bore of pipe 75 mm complete all as specified and directed. |
| 10 | S&F in replacement of broken cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, fixed to wall with clamps etc. bore of pipe 100 mm complete all as specified and directed. |
| 11 | S&F cast iron bends (sand cast) (any radius), diminishing pieces or tapers soil/waste pipes 75mm in any length (larger bore measured) with oval access doors complete all as specified and directed. |
| 12 | All as per the description of srl item No 11 above but bore of pipe in 100 mm. |
| 13 | S&F 100mm cast iron branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel brachs with oval access doors as in door 'T' , door bends, 'Y' section complete all as specified and directed. |
| 14 | S&F in repair SFRC GT covers with and including frame medium duty over all size 500 mm x 500mm x 80mm thick factory made and test load 10 tonnes (MD-10), strength as per IS-12592 (2002), ISI marked all as specified by Engr-in-Charge |
| 15 | S&F in repair SFRC manhole covers with and including frame medium duty over all size 1000 mm x 500mm x 80mm thick factory made and test load 10 tonnes (MD-10), strength as per IS-12592 (2002), ISI marked all as specified by Engr-in-Charge |
| 16 | S&F in repair SRFC precast fibre reinforced cement concrete Manhole cover (Ist quality) including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 600mm dia x80mm thick complete all as specified and as directed. |
| 17 | Excavation in any type of soil in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out complete all as specified and as directed. |
| 18 | Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified and as directed. |
| 19 | Removing excavated material not exceeding 50M and depositing where directed at a lavel not exceeding 1.5m above the starting point, soil omplete all as specified and as directed. |
| 20 | M&L for 150mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortarv incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge |
| 21 | M&L for 200mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions including demolition and breaking up old sewage line of any type and any dia set in cement mortar incl demolition of PCC huanching and bedding complete all as specified and directed by Engr-in-Charge |
| 22 | Cutting into existing manholes for connecting new drains, of 100 mm to 300 mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required, complete all as specified. |
| 23 | Demolition of Concrete of any description and in any position not otherwise specifically provided for. |
| 24 | Demolition of brick work or stone masonry built in cement mortar including all quoines arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles complete all as specified. |
| 25 | Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM(1:4) incl Dismantling of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified. |
| 26 | M&L for PCC 1:2:4 type B0, using 12.5mm graded agg as in coping, kerbs or mud stops, rounded or chamfered on edges completed as specified. |
| 27 | M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in surface channels, drains, side guide wall including all necessary form work complete all as specified and directed. |
| 28 | Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, including cutting of trees, shrubs or any type of vegitation upto and including roots all as specified. |
| 29 | Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM(1:4) finished even and sooth w/o using extra cement |
| 30 | M&L for plain cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate, 75mm thick as in plinth protection/pavment and the like, finish the surfaces even and fair complete all as directed and specified |
| 31 | M&L machine pressed precast rubber mould coloured concrete interlocking paver blocks of 60 mm thick any shape and size conforming to IS 15658-2006 ,M-35 grade with grey cement and no pigment over complete all as specified and directed. |
| 32 | Supply only 40mm thick Sand filling under floors or in Foundation including watering & consolidation etc complete all as spd. |
| 33 | M&L PCC 1:4:8, type D2, using 40 mm graded aggregate 75 mm thick as in sub floor, Sub base, floor complete all as specified & directed. |
| 34 | M&L Chequered cement concrete tiles 300mm x 300mm x 25mm thick, set, jointed & pointed in neat cement slurry in floors with grey cement and pigment over screed bed or bedding layers of mortars 15 mm thick in CM 1:6 , all as specified and as directed. Please Enable Macros to View BoQ information |