| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GARRISON ENGINEER (AF) BANGALORE NAME OF WORK : REHABILITATION OF WATER SUPPLY AND WATER STORAGE INFRASTRUCTURE INCLUDING WATERPROOFING TREATMENT, LEAKAGE/SEEPAGE RECTIFICICATION OF OHT, UG SUMP AND OTHER WATER RETAINING STRUCTURES AT CHAFB CA NO: GE(AF)/B/ OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | M&L for seven stage cleaning and sterilization of inside the RCC/ PVC water storage tank of capacity not exceeding 500 Ltr of any description and in any position comprising following cleaning and sterilization of water tanks through bacteriological treatment by using TERBAC G5/Inchlor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Location: CHAFMAKE: RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE OR TECHNO-COMMERCIALLY EQUIVALENT AS APPROVED BY GE(a) First Stage is to drain out the water by using exit valve or high capacity dewatering system. (b) Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/ Inoxi-60/NB-69 laboratory tested branded chemical of the company and scrubbing the walls of the tanks. (c). Third strage is fresh water cleaning by high speed jet pump. (d). Fourth stage and first bacteria screening is desertification by using TERBAC-G5/ Inohor-5/NB-10 a Govt Laboratory certified brannded halogen compound or E in C approved Equivalent product (e). Fifth stage is cleaning the floor of water tank by industrial vacuum cleaner. (f) . Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tank and kills all suspended bacteria.(g) Seventh stage of cleaning and third bacterial screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65/Inoxi-60/NB-69 or E-in-C approved equivalent Product. |
| 3 | NOTES:-(i) COMPANY SHALL SUBMIT GOVERNMENT LABORATORY TEST CERTIFICATE OF TERBAC-G5/INCHLOR-5/NB-10, TERBAC-G65/ INOXIi-60/NB-69, BEFORE CLEANING, FIX THE STICKER MENTIONING THE DATE OF CLEANING & NAME OF SITE AND ALSO PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATER TANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE(ii) OUTLET PIPE OF OHT SHOULD BE PLUGGED BEFORE CLEANING THE OHT TO AVOID ENTERING SCALES AND THE SAME SHELL BE RECONNECTED AFTER CLEANING THE OHT AND THE QUOTED RATE SHALL BE DEEMED TO INCLUDE FOR THE PROVISION . (III) STERILIZATION TEAM SHALL BE COMPRISED OF AT LEAST 30% MEMBERS WHO ARE MINIMUM 03 MONTHS CERTIFICATE HOLDER IN WATER TANKS STERILIZATION. (IV) CONTRACTOR SHALL BE RESPONSIBLE FOR RECTIFICATION OF COMPLAINTS OCCURRED DURING CLEANING THE TANK AND SHOULD ENSURE THAT NO WATER IN TANK/OVER FLOW DUE TO BROKEN OF FLOAT VALVE/ BLOCKAGE . THE WORK SHALL BE CARRIED THROUGH SPECIALIZED AGENCY (V) RATE QUOTED SHALL BE INCLUDED FOR ALL THE ABOVE PROVISIONS. MAKE: RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE OR TECHNO-COMMERCIALLY EQUIVALENT APPROVED MAKE |
| 4 | All as per ser item No 1.00 here-in-before but for of inside the RCC/ PVC water storage tank of capacity not exceeding 1000 Ltr through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. MAKE: RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE OR TECHNO-COMMERCIALLY EQUIVALENT APPROVED MAKE. |
| 5 | All as per ser item No 1.00 here-in-before but for of inside the RCC/ PVC water storage tank of capacity not exceeding 2000 Ltr through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. MAKE: RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE OR TECHNO-COMMERCIALLY EQUIVALENT APPROVED MAKE |
| 6 | S&F in repair Ball brass valves bearing ISI Mark high pressure with polytene float and flynut complete including connection with existing iron pipe and brass ferrule with necessary fittings for iron pipe of 20 mm bore complete all as specified and directed. |
| 7 | S&F 20 mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11including all necessary fittings on walls/ceiling (surface/conclead) or laying in floors in repairs complete all as specified and directed.Note :- Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work ( Ground floor to Seventh Floor). |
| 8 | Demolition of brick work or stone masonary built in cement mortar including all quoins arches pillars etc complete all as specified and directed. |
| 9 | Demolition of cement concrete(unreinforced) in ground floors and pavings n.exc 15cm thickness etc complete all as specified and directed. |
| 10 | Demolition of Reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended work complete all as specified and directed. |
| 11 | M&L Making V groove of 10mm wide and 30mm deep or upto the extent of joint/crack present at site over joint/ crack line using electricity operated angle grinder with diamond concrete saw blade and cleaning it by air blower as directed. The groove shall be cut on the concrete surface along the joint/crack over RCC structure to be repaired complete all as specified and directed. Note: Work shall be executed by the authorized applicator of manufacturer only. |
| 12 | M&L Sealing of exposed 'V' groove of 10mm wide and 30mm deep with Sikagard 694 F(l) or Quick Fix or equivalent solvent-free, moisture tolerant, thixotropic, two part structural adhesive and repair mortar cum surface levelling mortar complete all as specified and directedNote: Work shall be executed by the authorized applicator of manufacturer only. |
| 13 | M&L Providing & Applying Two coats of AquaArm Top Guard(ready to use polymer modified cementatious coating) inside of the wall & floor of the tank. First Coat should be applied horizontazlly and second coat should be applied vertically; The thickness of coating shall not be less than I.5 mm complete all as specified and directed.Note: Work shall be executed by the authorized applicator of manufacturer only. |
| 14 | M&L Applying two coats of Sikagard 67 or AquArm Tank Coat, a water based epoxy coating certified for portable water on all over the concrete surface from inside. Apply the first coat by brush allow it to dry for 6-8 hrs and then apply 2nd coat and allow it to cure for complete 24 hrs. The coating shall be applied using brush application. The Thickness after two coating should not be less than 500 microns complete all as specified and directed.Note: Work shall be executed by the authorized applicator of manufacturer only. |
| 15 | M&L for chipping of spalled and loose concrete and cleaning rust from reinforcement by sand brushing & scrubbing down concrete surfaces with wire brushes cleaning with water allowed to dry; applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bonding coat of a layer of epoxy FOSROC and NITOBOND adhesive on complete exposed surfaces of concrete and provide guniting in two layers over steel welded mesh 1.4 mm dia of wire and total aperture 25 mm, thickness of gunite not exc 25 mm thick (average thickness) using cement mortar 1 :3 ; cement mixed with polycrete admixture @ 2 % by weight of cement or as per manufacturer instructions and finally applying cement plaster over gunite surfaces of required thickness to give an even uniform and smooth finish conforming to proper Geometrics in cement mortar 1:4 to match with the existing surface as in side and soffits of SWT (Static water tank), wall and beams etc complete including necessary scaffolding ,shuttering necessary chased to brick work or RCC members at any height incl removing of small trees shrubs complete all as specified and directed.Note: steel welded mesh shall be welded with the existing reinforcement. The cost of welded mesh shall be deemed to be included in the quoted rate |
| 16 | All as per Item no 13.00 here-in-before but average thickness of gunite exc 25 mm thick not exc 50 mm thick. |
| 17 | Cutting/chipping the spalling of wall & concrete surface and trimming & cleaning the surface to receive plastering all as specified and directed including all necessary form work & scaffolding and safety measures complete all as specified and directed. |
| 18 | Supply only wire netting of galvanised steel wire , 1.23 mm dia size of mesh 25mm complete all as specified and directed. |
| 19 | M&L for RCC type B1 1:2:4 using 20mm graded aggregate as in cantilevers, parapet, lintels over 1.5 m span. etc complete all as specified and as directed. |
| 20 | M&L for RCC type B1 1:2:4 using 20mm graded aggregate as in slabs complete all as specified and directed. |
| 21 | M&L for providing precast cement concrete type B1 1:2:4 using 20 mm graded stone aggregate in landings, cover slabs,shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and directed. |
| 22 | M&L for form work to sides and soffits of floor or roof beams, lintels, cantilevers, slabs, shelves.plinth beams including supports etc. rough finished in curved surfaces complete all as specified and directed. |
| 23 | S&F Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. |
| 24 | S&F Mild steel TMT bars 6mm to 8 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. |
| 25 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 26 | Cutting holes in brick walls exc half brick but not exc full brick wall in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 complete all as specified and directed. |
| 27 | S&F Mild steel hold fast made out of MS flat iron 40 x 6 mm thick for chowkats and other small articles including making shape, drilling hole etc complete all as specified and directed. |
| 28 | Dismantling structural steel work including doors, gates and similar works but excluding framed truss complete all as specified and directed. |
| 29 | M&L for plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 30 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 31 | S&F Mild steel work as in posts and strut in fencing including cutting cutting tops to shape as directed drilling holes notching for wire etc complete all as specified & directed. |
| 32 | Supply only 75x75mmx4mm dia chain link MS galvanised fencing or any size or type including line wires any type of standards rails , standing bolts etc complete all as specified and directed. |
| 33 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire and taking down existing fencing complete all as specified and directed. |
| 34 | S&F Welded steel wire fabric supplied and fixed complete to wood or steel members weight not exc 4 Kg /Sqm complete all as specified and directed. |
| 35 | M&L for Pre-cast cement concrete block masonry with solid blocks type C1, 1:3:6 ( 20 mm graded aggregate) exc. 10 cm in width and setting in mortar 1: 6 complete all as specified and directed. |
| 36 | M&L for Providing pre-cast cement concrete solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) type C1, 1:3:6 ( 20 mm graded aggregate) and setting in mortar 1:6 , complete in walls complete all as specified and directed. |
| 37 | M&L for 100 mm thick PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) for floor (base of SWT) including finishing the surface even and smooth with using extra cement including mixing of water proofing compound wherever required as per manufacturers instructions complete all as specified and directed.Note : WPC shall be measured & paid separately |
| 38 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/ loose soil complete all as specified and directed. |
| 39 | M&L for 75 mm thick PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) including finishing the surface even and fair complete all as specified and directed. |
| 40 | M&L for coloured designed chequered cement concrete tiles of a size 300x300x25mm thick with white cement & pigment in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match and including a 15 mm thick screed bed of cement mortar 1:6 all as specified and directed. |
| 41 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and fair without using extra cement including mixing of water proofing compound wherever required as per manufacturers instructions complete all as specified and directed.Note: WPC shall be measured & paid separately |
| 42 | M&L fo Rendering 5 mm thick on fair faces of concrete surfaces in cement mortar 1:3 in ceiling of chajja,roof projection,shelve etc and finished even and smooth without using extra cement complete all as specified and directed. |
| 43 | Supply only liquid water proofing compound of approved quality complete all as specified and directed. |
| 44 | M&L Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 45 | M&L Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 46 | Running Welding in repair thickness of metal to be welded exc 6mm but n exc 9mm and over cut to length bent to shape as required complete all as specified and directed. |
| 47 | Running Welding in repair thickness of metal to be welded exc 9mm but n exc 20mm and over cut to length bent to shape as required complete all as specified and directed. |
| 48 | Supply only high strength corrosion resistant TMT bars 8-12 mm dia and over cut to length bent to shape complete all as specified and directed. |
| 49 | M&L for preparing new plastered surfaces and applying three coat of white wash on surfaces of walls complete all as specified and directed. |
| 50 | Complete removal of existing treatment of old external plastered wall & Concrete surfaces and applying three coat of white wash complete as per manufacturers instructions complete all as specified and directed. |
| 51 | Removing demolished material ie building material concrete debris of any type etc to a distance of 09 KM beyond and up to 10 KM out of premises of metropolition area including loading, unloading by manually or by mechanical means (JCB) and to be transported through trolly or tipper and staking at the destination as and when directed by Engr-In-Charge during execution. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |