| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GE 881 EWS C/O 56 APO NAME OF WORK: PROVN OF SEPTIC TANK AND SOAKAGE WELL FOR 100 USERS AT LKG(RR) AND REPAIR / REPLACEMENT OF SOLAR LIGHTS IN 10 IB AT KG TOP AND DEMOLITION OF BLDG NO T-41 LOCATED AT VILL-SAMOTE POONCH UNDER GE 881 EWS. Contract No: GE/PNH-45/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. |
| 3 | Dismantling of AC/CGI plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering, all as specified and directed. |
| 4 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5Sqm and not exceeding 4Sqm each, complete all as specified and directed. |
| 5 | Taking down chowkhats or frames n. exc 1.5 Sqm but (without taking off shutters from frame) complete all as specified and directed. |
| 6 | Dismantling of timber scantling 40sqcm and over in section unframed work,as in any position, complete all as specified and directed. |
| 7 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness,complete all as specified and directed. |
| 8 | Excavation in trenches n.exc 1.50m wide and n.exc 1.50m in depth for foundation etc. or for shafts, wells, cesspits, manholes,pier holes, etc.10 sqm on plan and getting out in any type of soil, complete all as specified and directed. |
| 9 | PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in bed concrete to drain pipes of 150mm bore including packing under and haunching against the sides of pipes after they are laid and tesed ,complete all as specified and directed |
| 10 | RCC pipes class NP2 150mm bore and jointed with collars, laid in trenches or in floor in repair complete all as specified and directed |
| 11 | Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4, all as specified and directed. |
| 12 | Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations filling,sub base and mass concrete, complete all as specified and directed. |
| 13 | Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in benching of manholes slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 14 | Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping,bed plates etc slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 15 | Rendering 15mm thick on other than fair faces of brick or stone masonry wall surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement including mixing of wpc in the proportion as mentioned in manufacture, complete all as specified and directed.NOTE-(Supply only WPC shall be measured and paid seperately) |
| 16 | TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and directed. |
| 17 | Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in cover slabs (for manholes) ,shelves and similar articles with plain faces including necessary moulds and setting in cement mortar 1:6 , complete all as specified and directed. |
| 18 | Supply only liquid water proofing compound @ 0.20 Ltr per kg of cement or as per manufacture instruction complete all as specified and directed. |
| 19 | Returning, filling in, including spreading, leveling, watering and well ramming in two layers not exceeding 25cm thick, in any type of soil, complete all as specified and as directed. |
| 20 | Removing excavated material (soil) not exceeding 50m and deposition where directed at a level not exceeding 1.50m above the starting point, all as specified and directed. |
| 21 | Construction of RCC septic tank conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation , RCC M-30 Design mix in walls, base slab, baffle walls and roof slab including beams etc with vent shaft , manhole openings with cover connection etc complete with effective depth of 1.5 meter for 100 users complete all as specified and directed. |
| 22 | Construction of soakage well of size 1.8 M dia X 3.0 M effective depth with including excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM 1:4, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specfied and shown on drawing No. CEUZ/TD/1585/2021(SH 1/4 TO 4/4). |
| 23 | EM PORTION:-Taking down old unsv solar street light fittings any type from pole and fixing with LED Solar street light ftting 12 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed.(Excavation and earth work and PCC shall be measured and paid seperately) |
| 24 | Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundations filling,sub base and mass concrete, complete all as specified and directed. |
| 25 | Thermo plastic street light weather proof out door type junction box of size 240mmX130mmX95mm complete with 4 way connector-01 No, 6 Amps SP MCB-01 No , easy openable and having locking arrangement including incoming and out going cable holes with fixing MS clamp and water tight polymade cable gland for each connection with and including taking down old unsv junction box, complete all as specified and directed. |
| 26 | PVC insulated and sheathed multicore flexible cable copper conductor 1100 volts grade conforming to IS-694/2010 of size 1.5 sqmm 3 core including 25mm PVC conduit from junction box to light fittings connecting up complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |