Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #56058071

Tender for Construction of otm Accommodation for mdc at Nasik Road Camp

Issued by Statutory Bodies & Commissions/Committees · Nashik, Maharashtra
Tender Value
6.70 Crore
Estimated cost
Bid Submission
23 Jul 2026
15 days left
EMD
6.60 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nashik → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction of otm Accommodation for mdc at Nasik Road Camp

BOQ

Name of Work:-
Sl. No. Item Description
1SCH 'A' PART-I To XII: Note: This schedule is pre-priced by MES and the rate indicated as under Col 5 signifies this fact only
2Total amount of Sch ‘A’ Part I (Building & Structures)
3Total amount of Sch ‘A’ Part II (Internal Water Supply)
4Total amount of Sch ‘A’ Part III (Internal Electric Supply)
5Total amount of Sch ‘A’ Part IV (Road, Path and Culverts)
6Total amount of Sch ‘A’ Part V (Area Drainage)
7Total amount of Sch ‘A’ Part VI (Sewage Disposal)
8Total amount of Sch ‘A’ Part VII (Compound Wall, Fencing and Gate)
9Total amount of Sch 'A' Part-VIII (External Water Supply)
10Total amount of Sch 'A' Part-IX (External Electric Supply)
11Total amount of Sch 'A' Part-X (Rain Water Harvesting)
12Total amount of Sch 'A' Part-XI (Site Clearance, Excavation and Earthwork)
13Total amount of Sch 'A' Part-XII (Demolition/Dismantling)
14SCHEDULE 'A' PART-XIII (MISC B/R AND E/M WORKS)NOTE: Schedule ‘A’ Part II to XII items, which are not Prepriced by MES are given here under, Bidders shall insert their rate in Column-6 only and the Estimated rate indicated under Col 5 as \\"0.00\\" are for that purpose.
15S&F Modular 20 Amp, Mini MCB SP C Curve, AC 230 Volts, laser marking, lSI marked complete all as specified and directed.
16S&F Modular type telephone socket RJ 11 with Shutter 1 module, laser marking complete all as specified and directed.
17S&F Modular type TV socket, 1 module complete all as specified and directed.
18S&F Sheet metal enclosure (factory made), TPN Vertical Distribution Boards (MCCB Incomer) IP 43 protection Double Door: Plain 4 way with 200 Amps rated busbar all as specified and directed.
19S&F Sheet metal enclosure (factory made), TPN Vertical Each Distribution Boards (MCCB lncomer) IP 43 protection Double Door: Plain 8 way with 200 Amps rated busbar all as specified and directed.
20M&L Excavation trenches in any kind of soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth by manual means or mechanical means (hydraulic excavator) all as directed and getting for laying of cable, foundation etc and all as per the direction.
21M&L Excavation by manual means or Mechanical means (Hydraulicexcavator) / in Foundation Trenches or drains (not exceeding 1.2 m in width or 10 sqm in on plan), including dressing of sides and ramming of bottoms , lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
22M&L Excavation by manual means or Mechanical means (Hydraulic Excavator) over areas not exceeding 1.50 m deep and getting out in soft/Ioose soil.
23M&L Construction valve chamber with brick masonry of size 0.6 m x 0.6 m x 0.6 m (internal dimension) with 15 cm thick foundation using PCC 1:3:6 type D-2 (using 40 mm graded stone aggregate), 23 cm thick brick wall built in cement mortar (1:6), 10 mm thick plaster in cement mortar (1:4), on internal and external surface (above ground level), finished even and fair without using extra cement, 5 mm thick MS sheet cover with, 40 mm x 40 mm x 6 mm angle frame fixed on 150 mm thick PCC (1:2:4) type B-1, (using 20 mm graded stone aggregate) as in including 25 mm x 6 mm flat iron hold fasts, handles, hinged with locking arrangements and applying two coats of synthetic enamel paint over one coat of red oxide primer to all steel surface including excavation and earth work in hard/dense soil return filling in disposal of surplus soil to a distance not exceeding 50 m outside MD land etc, complete all as specified and directed.
24M&L Boring of holes under road, pavements, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm Dia suitable for 0.4 MPa working pressure complete all as specified and directed.
25S&F Timeline distribution board digital time switch 32 Amp, 3 pole 230 volts cat ref TL032DB0 of IndoAsian complete including Contactor and Digital type time switch.
26M&L Double Walled Corrugated DWC HDPE pipe of outer dia 50 mm and inner dia 38 mm including 90 degree bends with coupler and rubber ring laid in trenches of size 50 mm suitable for cable protection complete all as specified and directed.
27M&L Double Walled Corrugated DWC HDPE pipe of outer dia 90 mm and inner dia 75 mm including 90 degree bends with coupler and rubber ring laid in trenches of size 90 mm suitable for cable protection complete all as specified and directed.
28Supply, fixing and install 7 m height octagonal pole top 70 mm, bottom 130 mm, 3 mm thickness with base plate 200 x 200 x 12 mm and GI 64 micron, M 19 x 600 EN 8 grade foundation bolt and 1.5 m decorative arm for light fitting, MCB SP 6 Amp, Busbar junction complete including foundation (drawing provided by OEM for foundation of pole) and all as specified and directed.Note:- Rate for RCC foundation as per drawing, excavation, 7 m pole, decorative, arm, foundation bolts and nuts including in this item rate.)
29Supply, install, testing and commissioning of outdoor type cubical panel board suitable for 3 phase 4 wire 415 Volt, 50 Hz and type tested at CPRI at 415 Volt factory fabricated in an approved factory having modern fabrication process powder coated in approved shard having thickness not less than 100 microns provided with suitable gasket to make it dust /vermin proof and general construction confirming to IS 8623793 comprising of the following :- OUTER SHELL : The outer shell shall be made out of-3.15 mm thick CRCA Sheet and MS angle section 50 x 50 x 6 mm frame, factory fabricated with front and back openable double door system lockable/openable by keys from both side having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The dimension of the shell should be adequate to accommodate inner shell described below giving minimum 75 mm space all round. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54.
30INNER SHELL: Inner shell shall be made out of 2 mm thick CRCA sheet duly compartmentalized for each control gears, front & back openable single door system by keys. To accommodate incomer/outgoing MCCBs and TPN copper busbar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN busbar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators. The degree of protection for inner shell shall be IP-42 & carry the following items:(a) Incoming: MCCB 160 Amps, 4 pole; 415 Volts, 50 Hz ICU 35 KA thermally adjustable between 70-100% - 01 No. (b) Outgoing: (i) MCCB 125 Amps, 4 pole, 415 Volts, 50 Hz ICU 25 KA 02 Nos.(ii) MCCB 32 Amps, 4 pole, 5 Volts, 50 Hz ICU 16 KA - 01 No.(ii) MCB 32 Amps, Triple pole & Neutral, 415 Volts, 50 Hz ICU 10 KA- 02 Nos.(c) Instrumentation : The inner cubical shall carry the following : (i) Digital panel multifunction meter to measure current, voltage, frequency & power factor having programmable CT ratio (CT ration should be equal to the rated current carrying capacity of incommer MCCB) & built in selector switch of size 96 mm x 96 mm accuracy class 1.0 suitable to work on auxiliary power supply of 240 volts AC with backup protection by 2 Amp MCB. (ii)Indication lamp 22.5 mm dia LED type, 240 Volts AC at the incommer of the unit to show 3 phase availability at the outgoing of incommer with back up protection by 2 Amp MCB. (iii) Inspection LED invertor lamp 12 Watt with movable non ferrous chromium plated arm fitted on topside of inner shell.
31M&L Boring of holes under road, pavements, hard standing by trenchless technology using ultra sound technique and necessary machine for LT underground cable suitable for 0.4 MPa working pressure complete all as specified and directed.
32Supply, installing, connecting, testing and commissioning storage type water cooler 150 Litres capacity and cooling capacity 150 Litres per Hour, based on eco friendly gas R-134a, complete body made of food grade stainless steel with two taps (both cold water) complete with inlet drain pipe connection with inbuilt float valve all as directed at site including extending drain out pipe to the nearest drain system complete of make Blue Star/Usha/Voltas all as specified and as directed.
33S&F Submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100 Volts grade, FRLS type, cables 2.5 Sqmm drawn through in and including PVC heavy duty concealed conduit including 2.5 Sqmm 1100 Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed.
34S&F Sheet metal enclosures Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 to 32 amps, 240 Volts complete all as specified and directed.
35S&F Inverter spilt air conditioner electric driven single phase of capacity 1.5 TR, BEE 5 Star rated (latest) with ISEER 5 W/W complete with control remote, standard copper cable of appropriate size of 3 m length up to power point, initially filling of refrigerant and installation of outdoor and indoor unit ((without fixing bracket) with suitable size of inlet and outlet copper tubing with proper insulation with required size and length, fixing drain pipe making hole on wall, testing the same after commission as recommended and directed. Specification of air conditioner is as under:-Tonnage : 1.5 TRRefrigerant Gas : R 32 (Non CFC)Power Supply : 230 Volts/50 Hz single phase, wide operating voltage range 145 to 270 V.Condenser Coil : CopperConnected pipe : 5 mRated cooling Cap : 5200 WattConnected Cable : Copper with appropriate size 3 mAir Flow Volume indoor : 930 (CMH)
36S&F Inverter spilt air conditioner electric driven single phase of capacity 2 TR, BEE 5 Star rated (latest) with ISEER 5 W/W complete with control remote, standard copper cable of appropriate size of 3 m length up to power point, initially filling of refrigerant and installation of outdoor and indoor unit ((without fixing bracket) with suitable size of inlet and outlet copper tubing with proper insulation with required size and length, fixing drain pipe making hole on wall, testing the same after commission as recommended and directed. Specification of air conditioner is as under:-Tonnage : 2 TRRefrigerant Gas : R 32 (Non CFC)Power Supply : 230 Volts/50 Hz single phase, wide operating voltage range 145 to 270 V.Condenser Coil : CopperConnected pipe : 5 mRated cooling Cap : 6050 WattConnected Cable : Copper with appropriate size 3 mAir Flow Volume indoor : 950 (CMH)
37S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor-type & designed-for-input variation between 130 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% including Digital Display and time delay system and of capacity 4 KVA.Make : V-Guard/blue star.
38S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% including Digital Display and time delay system and of capacity and of capacity 5 KVA.Make: V-Guard/blue star.
39Supply, Install, testing and commissioning refrigerators, electric driven (single phase), Single door, base stand with drawer, capacity 185 litters, 5 star rated, work without stabilizer (90-310 V), Anti rat bite type sleeve complete all as specified and as directed.
40Supply, fixing, testing and commissioning of vertical mounting type electric water heater, storage type, 230 Volts, AC, 50 Hz, single phase, 5 star rated of capacity 25 litres with following specifications:-(i) Rated wattage in watt: 2000 Watt.(ii) Type of water heater: Closed type.(iii) Rated pressure: 0.8 Mpa (Class I).(iv) Water head: 80 m.(v) Tank warranty: 10 Years.(vi) Outer body material: Engineering thermoplastic.(vii) Safety valve: 4 in 1 multifunctional valve.(viii) Thermostat: Capillary type.(ix) Heating element: Copper tube, Tubular type single pocket.(x) Insulation type: PUF insulation.(xi) Tank material: MS, with glass lined coating.(xii) Cord type/ material: 2.5 Sqmm, 3 core PVC insulation.(xiii) Maximum reheating type: 60 minutes.(xiv) Min. hot water output: 50 degree Celsius minimum.Note:- (i) Rate including for grouting of fasteners, nuts and bolts are including in this item rate.(ii) Contractor shall furnish original tax invoice with manufacturers warranty 10 years for tank, 02 years for element and 02 years for product.
41Supply, installation, testing and commissioning Diesel Engine driven generating set of 82.5 KVA capacity, 3 phase, 4 wire, 415 V, 50 Hz, 1500 RPM, AC power supply with power factor 0.8 (lagging), coupled directly to alternator, mounted on a common base plate complete with integral acoustic enclosures (shall have salient features) modular bolted construction & pure polyester based coating to ensure long life in all weather conditions & for outdoor application / installation, integrated design thereby facilitating / easy handling. The design of integral acoustic enclosure shall be approved by National Physical laboratory as per central pollution control board (CPCB-IV +) latest regulation / norms (NOx+HC < 4.0, CO < 3.5, PM < 0.2 & smoke limit < 0.7) with fuel tank, battery & standard accessories, tools & spares as provided by manufacturer complete with necessary PCC foundations. PCC foundation as per OEM / manufacturer recommendation to bear the load of DG set having suitable size including excavation and earth work with block masonry work and plastering all as specified and as directed:-(1) ENGINE - Liquid cooled diesel engine at 1500 RPM, of capacity 82.5 KVA, 415 V, 50 Hz, No of cylinder - 03 Nos / inline consists of direct injection, turbo-charged, four stroke liquid cooled technology confirming to BS: 5514 and IS: 10000 suitable for prime duty generating set. Alternator under NTP conditions with provision of 10% over load for 1 hour confirming to latest CPCB norms. The Engine shall consist of the following:-
42(a) Aspiration / cooling - TCAC(b) Exhaust silencer(c) Expansion bellows(d) Lube oil cooler(e) Lube oil filter(f) Radiator, radiator fan and mounting(g) Fuel pump, with governor(h) Fly wheel with starter ring(j) Battery charging alternator 12 volt / 35 Amp(k) 12 Volts electric starter motor (DC).Engine Monitoring system:- The genset monitoring and safety system, having following features :-(a) Control panel consisting of built in ON/OFF/start key(b) Battery charging voltmeter.(c) Electronic hour meter.(d) Indication & Monitoring of oil pressure & safety trip in case of Low oil pressure.(e) Indication & Monitoring of coolant temperature & safety trip in case of high coolant temperature. (f) In-built engine shut down system in case of engine overspeed.(g) Indication & Monitoring of fuel level and alarm.(II) BRUSH LESS ALTERNATOR:- Alternator suitable rated for 82.5 KVA DG at 0.8 PF, 415 V, 3 phase, 4 wire, 50 cycles/sec, 1500 RPM, current (1P/3P) (Amp) - 114.77, 4P rotating field type, automatic voltage regulator, Bearing 1, sealed, coupling - flex disc, unbalanced load capacity - 25% of rated amps with Brushless Excitation Band of voltage regulation + 1% of rated voltage, from NO load to full load, Insulation class \\"H\\". The alternator generally conforms to BS: 2613/ IS: 4722.
43(III) BATTERY:- Heavy duty battery 12 volts of 88 AH connected to the system fully charged including lead and battery terminal's complete.Make: Exide or equivalent as recommended by OEM(IV) STANDARD CONTROL PANEL/ CONTROLLER : MODEL DSE 6120 MK(V) AUTOMATIC MAINS FAILURE (AMF) CONTROL PANEL (DOUBLE CONTACTOR)The control panel will be free standing, cubical type, outdoor type, front operated dust and vermin proof, fabricated out 3.15 mm thick CRCA sheet duly power coated after necessary pre-treatment process & consisting of following:-Power Circuit Mains02 No 4P contactor suitable rated2 No 3P MCCB suitably ratedControl & Metering Circuit1 No Microprocessor based AMF logic controller1 No KWh meter1 No Line Voltage Monitor1 set of control fuses1 No static battery charger circuit with ON/OFF switch. Battery charger \\"ON\\" indication.Reverse Polarity indication.1 No DC battery charging ammeter.(V) ONE SET OF ACCESSORIES COMPRISING OF:-(a) Fuel tank - Capacity of tank shall be to hold diesel sufficient for 08 hours running at full load, with following features:(i) Level indicator.(ii) drain plug. Please Enable Macros to View BoQ information
44(III) BATTERY:- Heavy duty battery 12 volts of 88 AH connected to the system fully charged including lead and battery terminal's complete.Make: Exide or equivalent as recommended by OEM(IV) STANDARD CONTROL PANEL/ CONTROLLER : MODEL DSE 6120 MK(V) AUTOMATIC MAINS FAILURE (AMF) CONTROL PANEL (DOUBLE CONTACTOR)The control panel will be free standing, cubical type, outdoor type, front operated dust and vermin proof, fabricated out 3.15 mm thick CRCA sheet duly power coated after necessary pre-treatment process & consisting of following:-Power Circuit Mains02 No 4P contactor suitable rated2 No 3P MCCB suitably ratedControl & Metering Circuit1 No Microprocessor based AMF logic controller1 No KWh meter1 No Line Voltage Monitor1 set of control fuses1 No static battery charger circuit with ON/OFF switch. Battery charger \\"ON\\" indication.Reverse Polarity indication.1 No DC battery charging ammeter.(V) ONE SET OF ACCESSORIES COMPRISING OF:-(a) Fuel tank - Capacity of tank shall be to hold diesel sufficient for 08 hours running at full load, with following features:(i) Level indicator.(ii) drain plug. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56058071
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 6.70 Crore
LAST DATE 23-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Construction of otm Accommodation for mdc at Nasik Road Camp
Basic Detail
Tender No 84618
Bidding Type Tender
Location
City Nashik
State Maharashtra
Key Dates
Publish Date 18 Jun 2026
Submission Date 23 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value 6.70 Crore
Tender Fee 3000
EMD 6.60 Lakhs
Exemption Available
Document List
84618-IFA-18Jun26.pdf
84618-maindrawing.rar
84618-TD1.rar
84618-TD2.rar
BOQ_865823.xls
e15cc632-5609-4398-b52a-1380a46c13c7.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
pdf

84618-IFA-18Jun26.pdf

rar

84618-maindrawing.rar

rar

84618-TD1.rar

rar

84618-TD2.rar

xls

BOQ_865823.xls

html

e15cc632-5609-4398-b52a-1380a46c13c7.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail