| 1 | M&L for Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed. |
| 2 | M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in plinth protection 50 mm thick complete all as specified and as directed. |
| 3 | M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed. |
| 4 | M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed. |
| 5 | M & L for brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radious built in cement mortar 1:6 pointed in cement mortor 1:6 with using old size bricks complete all as specified and as directed. |
| 6 | M&L for PCC M25 grade (Design mix) (with 20 mm graded stone aggregate) as in ramp landings broom finish etc complete all as specified and as directed. |
| 7 | M&L for RCC M25 grade (Design mix) using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in flloors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 8 | M & L for RCC M25 grade (Design mix) (with 20 mm graded stone aggregate) as in walls, retaining walls complete all as specified and as directed. |
| 9 | M&L for formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses etc; vertical or to batter of flat rough finished surfaces of concrete complete all as specified and as directed. |
| 10 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) of flat rough finished surfaces of concrete complete all as specified and as directed. |
| 11 | S&F for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 12 | M&L for coloured Non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 20 mm thick screed bed or bedding layers in cement mortar (1:4) complete all as specified and as directed. |
| 13 | M&L for coloured Non-skid Ceramic tiles 8-10mm thick (square/rectangular) polished, area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 20 mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and as directed. |
| 14 | M&L for colour glazed ceramic coloured tiles 200x100x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement as in vertical surfaces such as skirting, dados and risers to steps etc to match with and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed. |
| 15 | M&L for colour glazed ceramic coloured tiles 300mmx200mmx7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement as in vertical surfaces such as skirting, dados and risers to steps etc to match with and including 10 mm thick rendering in cement mortar (1:3) complete all as specified and as directed. |
| 16 | M&L for colour glazed ceramic coloured tiles 350mmx250mmx7mm/ 450x350x7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement as in vertical surfaces such as skirting, dados and risers to steps etc to match with and including 10 mm thick screed bed or bedding layers in cement mortar (1:3) complete all as specified and as directed. |
| 17 | M&L for colured Virified Ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 20 mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and as directed. |
| 18 | M&L for 20-25 mm thick Machine cut kota stone slab flooring laid over 20 mm thick screed bed in cement mortar (1:4) and jointed in grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 19 | M&L for 20-25 mm thick Kota Stone in riser of steps, skirting, dado and pillar laid over 20 mm thick screed bed in cement mortar (1:4) and jointed in grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 20 | M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in sub floor, sub base 40 mm thick complete all as specified and as directed. |
| 21 | M&L for Rendering 15mm thick on fair faces of brick or concrete surfaces in CM (1:6) finished even and smooth w/o using extra cement complete all as specified and as directed. |
| 22 | M&L for preparing of new plastered wall surfacesand applying two coats of cement based paint over a coat of primer complete all as specified and as directed. |
| 23 | M&L for Preparing of new plastered wall surfaces and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed. |
| 24 | M&L for Preparing new plastered or unplastered surfaces and applying Two coats of Acrylic weather coat exterior paint of required shade : and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 25 | M&L for three coats of white wash to newly plastered surfaces of walls including preparing newly plastered surfaces of walls complete all as specified and as directed. |
| 26 | M&L for three coats of white wash to newly plastered surfaces of ceilings including preparing newly plastered surfaces of ceilings complete all as specified and as directed. |
| 27 | M&L for False ceiling with 'E' board \\"Classic\\" , reinforced, designer series, board with HPSC of size 600 mm x 600 mm x 6 mm thick fixed in repairs on anodised aluminium snap grid to support the boards/files with aluminium anodised main 'T' section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and aluminium angle 25mm x 25mm x 1.40mm as on edges/sides including hanging arrangements complete all as specified and as directed. |
| 28 | S&F for aluminium anodised powder coated frame of standard section as directed or as perTD of CE(AF) shillong Zone for doors, windows, ventilators of any colour as approved with one or more rebates including joining cleat, etc for fixing etc complete all as specified and as directed. |
| 29 | S&F for aluminium anodised powder coated door shutters, with top rail of size 47.62mm x 44.45mm, intermediate rail 100mm x 44.5mm, bottam rail 88mm x 44.5mm, style size 44.45mm x 47.52mm, including necessary joining cleats, glazing clips, rubber neoprene packing/ rubber gasket, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and as directed.Note : all the aluminium shutter will be as per TD drg no:- AF/TD/242/15 sheet no 1/3,2/3,3/3 of CE(AF) shillong Zone. |
| 30 | S&Faluminium anodised powder coated window and ventilator shutters, sliding type with size of sliding shutter style 39mm x 20mm, top rail size 39mm x 20mm and bottom rail size 41mm x 20mm, joining cleats, glazing clips, rubber packing/rubber gaskets, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) complete all as specified and as directed. Note: all the aluminium sliding window shutter will be as per TD drg no:- AF/TD/242/15 (R) sheet no 1/6,2/6,3/6,4/6,5/6,6/6 of CE(AF) shillong Zone. |
| 31 | S&F for Aluminium Mortice lock, vertical type of size 75 mm, 4 lever complete all as specified and as directed. |
| 32 | S&F 5.5mm thick sheet glass, odinary quality in square exc 0.5m in each pane complete all as specified and as directed. |
| 33 | S&F for Steel rolling shutters with thickness of lath 1.0 mm, gear operated type with bevelled gear box and and crank handle, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete including taking down old one complete all as specified and as directed. |
| 34 | M&L for preparation of new steel or iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enamel (ordinary tint) paint over one coat of red oxide primer complete all as specified and as directed. |
| 35 | S&F for 500 Litres Capacity, HDPE (Double layered) Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed. |
| 36 | M & L for Providing cement concrete (1:2:4) Type B-1 (using 20mm graded aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, holdfast, kneelers, apex stones bed plates, kerbs with rounded or chamfered edges, water troughs and the like including weathering, slightly rounded or chamfered angles, necessary formwork, and throating complete all as specified and as directed. |
| 37 | S&F for 15mm bore galvanised steel tubes, medium grade for flush pipes, water supply pipes etc. Concealed in walls and ceilings or laid in floors, etc complete all as specified and as directed. |
| 38 | S&F for 20mm bore galvanised steel tubes, medium grade for flush pipes, water supply pipes etc. Concealed in walls and ceilings or laid in floors, etc complete all as specified and as directed. |
| 39 | Cutting chases for concealed water tubing or concealed conduit wiring pipe where making good to facing required and pointing in cement mortar 1:3 etc. in Brick wand and concrete. Walls & cutting not exceeding 10 cm girth complete all as specified and as directed. |
| 40 | S & F for 15mm bib tapss, fancy type, cast copper alloy cronium plated with cruth or butterfly handle, screwed don, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 41 | S&F for brass angle stop cock CP high pressure with capstan head long shank screwed down 15mm dia bore complete all as specified and as directed. |
| 42 | S& F for 20mm bore Gun Metel, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 43 | S& F for PVC conncetion, 15mm size with PTMT nuts of length 450mm complete all as specified and as directed. |
| 44 | M & L for vitreous china wash down water closet pan (pedastal pattern), including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and as directed. |
| 45 | S & F for PVC valveless, syphonic action type flushing cistern 10 ltr capacity low level white with inlet ball valve float and handle including brackets, Flush pipe of polyethylene of low or high density or PVC 32mm dia, for low level cistern complete all as specified and as directed. |
| 46 | S & F for PVC Health faucet with all accessories complete all as specified and as directed. |
| 47 | M & L for vitreous china wash basin of size 630 x 450mm, white, flat back, including brackets , 15mm bore pillar taps chromium plated, 32mm bore dia Waste coupling of PTMT (half or full threaded) , cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed. |
| 48 | S & F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 49 | S&F in repairs Soap dish, viterous china white approximate size 160X160X90mm complete all as specified and directed. |
| 50 | S&F for tubular towel rail, brass chromium plated, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 51 | S & F 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC bldg board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 52 | M & L for PVC floor trap, 75 mm dia, with grating including jointing with solvent cement complete all as specified and directed. |
| 53 | S&F for 32 mm bore (LDPE) pipes of pressure rating 6 kgf/sqcm, in waste pipe of WHB / Sink, fixed complete to walls,ceiling or in floors etc complete all as specified and directed. |
| 54 | S & F for PVC 75mm (SWR ) pipe single socketed in any length with rubbering joints fixed to walls complete all as specified and directed. |
| 55 | S & F for PVC (SWR) bend 110mm bore any radius complete all as specified and directed. |
| 56 | S & F for 110mm bore PVC (SWR ) pipe single socketed in any length with rubbering joints fixed to walls complete all as specified and directed. |
| 57 | S & F for PVC (SWR) bend 110mm bore any radius complete all as specified and directed. |
| 58 | S & F for 110mm bore PVC (SWR) junction single Tee equal or unequal complete all as specified and directed. |
| 59 | S & F for 110mm bore PVC(SWR) vent cowl complete all as specified and directed. |
| 60 | S & F for factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with mild steel square tube in opening as per specification and drawing complete all as specified and directed. |
| 61 | S&F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails, MS frames shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, Paneling of plain colour PVC sheet to be fitted in the MS frame welded/ scaled to the stiles and rails with suitable PVC Sheet beading and jointed together with solvent cement as per drawings and specifications complete all as specified and directed. |
| 62 | M & L for Cement Concrete (1:4:8) Type D-2 (using 40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and as directed |
| 63 | M & L for Providing cement concrete (1:2:4) Type B0 (using 12.5mm graded aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, holdfast, kneelers, apex stones bed plates, kerbs with rounded or chamfered edges, water troughs and the like including weathering, slightly rounded or chamfered angles, necessary formwork, and throating complete all as specified and as directed. |
| 64 | M&L for PCC 1:3:6 C-1 using 20mm graded agg as in surface channel and drain complete all as specified and directed. |
| 65 | M&L for Reinforced concrete pipes, class NP2, laid and jointed complete with collars of150mm bore laid and jointed on concrete bed complete all as specified and as directed. |
| 66 | M&L for providing precast cement concrete 1:2:4, Type B–1 using 20mm graded stone aggregate as in landings, cover slabs (for manholes etc.), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including formwork, set in cement mortar 1:4 complete all as specified and as directed. |
| 67 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 including distance pieces, cleats etc. and similar work complete all as specified and as directed. |
| 68 | S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 69 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof ridge /cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 70 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 71 | M&L for 150mm thick soiling (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and as directed. |
| 72 | M & L for 75mm thck (compacted thickness) water bound Macadam (WBM) with coarse aggregate of lime stone, sand stone, flinth or quartzite of grading 2 (63 to 40mm size) or grading 3 (50 to 20mm size) spread, rolled and consoildated using power road roller exc 8mm tonne but n'exc 120tonne to gradient and camber required complete all as specified and as directed. |
| 73 | M&L for forming construction joint 30mm deep x 10mm wide filled with sealing compound grade 'A' complete all as specified and as directed. |
| 74 | M&L for forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with a sealing compound Grade 'B' for 150mm thick concrete slab complete all as specified and as directed. |
| 75 | M&L for forming contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade 'B' for 150mm thick concrete slab complete all as specified and as directed. |
| 76 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 77 | Supply only polythene sheet black 50micron thick complete all as specified and as directed. |
| 78 | M & L for Providing cement concrete (1:3:6) Type C-1 (using 20mm graded aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, holdfast, kneelers, apex stones bed plates, kerbs with rounded or chamfered edges, water troughs and the like including weathering, slightly rounded or chamfered angles, necessary formwork, and throating complete all as specified and as directed. |
| 79 | M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed. |
| 80 | M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed. |
| 81 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup-ports overhangs, etc. also splays between floor and beams etc. of flat rough finished surfaces of concrete complete all as specified and as directed. |
| 82 | M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide of rough finished surfaces of concrete complete all as specified and as directed. |
| 83 | M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in soft/ loose soil complete all as specified and as directed. |
| 84 | M&L for removing excavted material to a distance exc. 250 m but n exc. 500m and depositing where directed at a level n exc 1.5 mtr above the starting point complete all as specified and directed. |
| 85 | S&F for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 86 | M&L for preparation of new plastered surface of wall/ roof/ floor by rubbing down/ scraping and three coat of exterior grade emulsion paint (weather coat) in camouflage pattern on wall, roof or floor in any surface over one coat of weather primer as specified and complete all as specified and as directed.Note: Weather proof acrylic paint to be used for painting in floor/ hard standing |
| 87 | Material and labour for Pavement Quality Concrete (PQC) (Design Mix) of minimum field flexural strength 45 Kg/ Sqcm (Lower control Limit) LCL after 28 days in Pavement slab using minimum 400 Kg of cement per cum with crushed stone aggregate of grading as specified including necessary form work and using non circular synthetic fibre reinforcement @ 25% of weight of cement of PQC laid in panels, spread and compacted using mechanical paver mecanically complete all as specified and as directed (Thickness of concrete shall be 150mm) Note :(a) All type of joint shall be measured and paid seperately under respective Items of BOQ (b) No deduction shall be made from concrete or space occupied by construction and dummy joint. However, deduction shall be made for the space occupied by expansion joints (c) The non circular fibre, syhthetic reinforcement mixed with concrete shall be measured and paid seperately as 'Supply only' under respective item of BOQ(d) Cost of any admixture required to achieve the desired properties of concrete shall be deemed to be included in the unit rate quoted for PQC nothing extra shall be paid in this account (e) No price adjustment shall be applicable if excees quality of cement content used in the work as approved in the Design Mix exceed 400 Kg. Minimum cement content shall be used 400 Kg per Cum |
| 88 | FENCINGM&L for excavating in post holes (or similar holes) in soft/ loose soil, each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and getting out soft/ loose soil complete all as specified and as directed. |
| 89 | M & L for Cement Concrete (1:3:6) Type C2 (using 40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 90 | M&L for RCC M25 grade (Design mix) using 20mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 91 | M&L for RCC M25 grade (Design mix) using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed. |
| 92 | M&L for RCC M25 grade (Design mix) using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed. |
| 93 | M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 94 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc. including provison of binding wire complete all as specified and as directed. |
| 95 | Supply only Chain link MS galvanised fencing any size or type, complete all as specified and as directed.Note: Weight of chain link fencing shall be ascertained by BOO. |
| 96 | S&F flat iron 50x6mm for securing wire mesh etc. all as specified and as directed covering to Fe-410-0 or Fe-310-0 complete all as specified and as directed. |
| 97 | S&F for joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e within 20mm of length indicated) conforming to Fe-410-W (Gde-E-250) quality A complete all as specified and as directed. |
| 98 | S&F of Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of stel steel sheeting or other covering, running rails and guides) and hanging; also fasteing and fixing conforming to Fe-410-W (Gde-E-250) quality A complete all as specified and as directed. |
| 99 | S&F for mild steel screw bolts (machine made) wit hexaginal or square heads at one and screwed the other of screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, with length of bolt exc 22.5 cm and n exc 30cm long and dia of neck 5 to 10mm complete all as specified and as directed. |
| 100 | S&F for galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossing with and provison of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed. |
| 101 | S & F COSEC-ZAL Super Razor punched barb tape (SRPBT) Aluminum base helix coil with and including necessary GI fixing clips for securing complete all as specified and directed with following specification: (i) Dia of coil (when unstretched)-610mm (ii) No of circles-51 turns per coil (iii) Weight of each coil with hessian pack -8.50 kg (+0.5) (iv) Coverage per coil -8RM (v) Central core wire: Made from 2.50mm dia GI-H.T.S.S wire as per IS-4454 galvanised as per IS-2629 (vi) Razor Punched Strip- Razor punched tape is CONSEC-ZAL steel comprising of Aluminum base with zinc alloy coating @ 150gm/Sqm conforming to ASTM A -792/A-792M with additional primer treatment of Epoxy/ Polyurethane & Finakl paint Top coat of Caufield green shade (BSL 139) by hot Dipping process (Note-Running length of the wall shall be measured for payment purpose) |
| 102 | M&L for formwork to sides of concrete fondations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertcal or to batter of flat rough finished surfaces of concrete complete all as specified and as directed. |
| 103 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions of square, rectangular or polygonal rough finished surfaces of concrete complete all as specified and as directed. |
| 104 | M&L for granite (of any type) tiles 16-20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing screed bed or bedding layer of 15 mm thick cement mortar1:4 for laying floor finishes complete all as specified and as directed. |
| 105 | M&L for granite (of any type) tiles 16-20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing screed bed or bedding layer of 10 mm thick cement mortar1:4 for laying floor finishes complete all as specified and as directed. |
| 106 | M&L for PCC 1:3:6 C-2 using 40mm graded agg as in foundation, filling and mas concrete complete all as specified and directed. |
| 107 | M&L for rendering 10mm thick in cement and sand mortor 1:6 on fair faces of brick work or cement concrete surfaces including finishing even and smooth without using extra cement complete all as specified and directed. |
| 108 | M&L for work kiln burnt bricks built in CM (1:6) using sub class 'B' bricks straight or curved on plan exceeding 6 Mtr mean radius complete all as specified and directed. |
| 109 | Excavating in trenches, n exc 1.5 m wide and exc 1.5 m but n exc 3.0 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in soft/loose soil complete all as specified and as directed. |
| 110 | M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in surface channels and drains complete all as specified and as directed. |
| 111 | M&L for brickwork with fly ash bricks of old size, straight or curved on plan with mean radius exc 6m in cement mortar 1:6 bricks roughly cut to radius or bricks with wedge shaped joints complete all as specified and as directed. |
| 112 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and as directed. |
| 113 | M & L for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C2 for 150mm pipe complete all as specified and as directed. |
| 114 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed. |
| 115 | M & L for on site LLDPE septic tank of capacity 5500 Ltr to 6000 Ltr with necessary strong basement with concrete as per manufacturer's instruction complete all as specified and as directed. |
| 116 | M & L for soak well including excavation in any type of soil, foundation in PCC 1:3:6 wall of honey combed with topping of M-25 concrete, incuding intercepting chamber made of Brick work in CM RCC cover slab in M-25/SFRC cover inter connecting pipe of RCC/DWC complete with brick bats of suitable size for 1.80 x 3.00 M deep efective depth complete all speciied and directed.Note: Refer TD Drg No. AF/TD/STRU/236 Please Enable Macros to View BoQ information |
| 117 | M & L for soak well including excavation in any type of soil, foundation in PCC 1:3:6 wall of honey combed with topping of M-25 concrete, incuding intercepting chamber made of Brick work in CM RCC cover slab in M-25/SFRC cover inter connecting pipe of RCC/DWC complete with brick bats of suitable size for 1.80 x 3.00 M deep efective depth complete all speciied and directed.Note: Refer TD Drg No. AF/TD/STRU/236 Please Enable Macros to View BoQ information |