| 1 | Dismantling of AC sheet (corrugated or semi corrugated etc) including AC ridges as in roof covering. |
| 2 | S & F, 6 mm thick Non-asbestos cement corrugated sheet fixed with ‘L’ type or ‘J’ type or cranked hook bolts. |
| 3 | Fixing only 6 mm thick asbestos cement corrugated sheet fixed with ‘L’ type or ‘J’ type or cranked hook bolts. |
| 4 | Dismantling Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings. |
| 5 | S&F prepainted galvalume aluminium zink coating GI based corrugated/ semi - corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering fixed with coach screw as per manufacturers instrution complete. |
| 6 | S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall and ridge,fixed with self tapping srews complete. |
| 7 | Dismantling timber scantling 40 sqcm and over in section in any position in framed work complete. |
| 8 | S&F Mild Steel Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates |
| 9 | M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified. |
| 10 | Demolition of brick wk masonry built in cement mortar incl all quoins arches pillars etc |
| 11 | M & L Brick wk with sub class ‘B’ bricks straight or curved on plan exc. 6m means radius in CM 1:6 |
| 12 | M&L Brick work with sub class 'B' Brick straight or curved on plan to any radius in half brick thick wall built in cm 1:4 |
| 13 | M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces and making even and smooth complete all as specified. |
| 14 | M&L for preparation of newly plastered wall surfaces and applying two coats of acrylic distemper over a coat of primer complete all as specified. |
| 15 | Dismantling floor, hearth or wall tiling, including cement mortar bedding (but not backing ) removing serviciable tile to store & rubbish off the permisses. |
| 16 | M&L Vitrified ceramic tiles 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete over 15mm thick screed bed in CM 1 : 6 complete all as specified. |
| 17 | M&L Vitrified ceramic tiles 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in vertical sufaces over 10mm thick backing coat in cm 1 : 4 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete. |
| 18 | M&L Non - skid Ceramic jointless tiles of any colour/shade 7 to 8 mm thick area of each tile exceeding 0.18sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles complete. |
| 19 | M&L Glazed coloured ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick backing coat in cm 1:4 complete all as specified.match |
| 20 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons |
| 21 | M&L Pre-polished Machine cut kota stone slab flooring 20-25mm thick over 20 mm thick cement screed bed in cm 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified. |
| 22 | Dismantling of wall and ceiling board any thickness/description including cover fillet. |
| 23 | M & L for 4 mm thick Asbestos cement plain building boards, fixed to timber framework with screws |
| 24 | M&L for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre incl 2mm dia G.I. ( upto 1200 mm length ) adjusting level to Purlins/ Rafter. . |
| 25 | M&L 4mm thick non asbestos fibre cement designer building board of size 600X600 fixed or laid/inserted to timber/GI/Aluminium framework fixed in ceiling flat or sloping. |
| 26 | Dismantling fencing wire mesh any type |
| 27 | Dismantling posts/pillers or struts (Wood, Steel, or RCC) any section, including taking out embedded portion and making good disturbed ground. |
| 28 | Excavating in post holes (or similar holes) each not exc 0.5 cu.m, getting out, retuning, filling in and ramming earth broken rubble mixed with earth around, in layers not exceeding 25 cm in soft / loose soil. |
| 29 | M&L for PCC 1:3:6 type C-2 using 40 mm graded stone as in foundation , filling and mass concrete complete. |
| 30 | M&L for TMT bars 10 mm dia and over cut to length, bent to shape reqd incl cranking bending etc and binding with MS wire (annealed) not less than 0.9 mm dia as in chain link fencing fixing |
| 31 | S&F Mild steel framed work as in posts and struts in fencing including cutting tops to shape as directed, drilled holes,notching for wire etcflats iron fillets (for securing wire mesh etc ) including all necessary drilling,bolting or fiveing etc, and similar work confirming to Fe-290 GdeE -165 . |
| 32 | Supply only 3 mm dia galvanised iron chain link fencing of mesh size 75x75 mm . |
| 33 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire. |
| 34 | S&F mild steel screw bolts (machine made ) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagoanl or sqare nut, n.exc 5cm long of diameter of shanks 11 to 15 mm |
| 35 | S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured |
| 36 | Description as per Ser item No 35 above but restraing rescurinng including making good staples etc only |
| 37 | M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 CM width or girth and applying two coats of synthetic enamel paint over a coat of red oxide of approved colour and shade. |
| 38 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. |
| 39 | M & L 15mm thick rendering on fair faces of brick work/concrete surface in CM (1:6) surface finished fair & even complete. |
| 40 | M & L PCC 1:2:4 type B-1 using 20 mm graded store aggregate as in coping including necessary form work. |
| 41 | M&L for preparation of newly plastered wall surfaces and applying two coats of cement based paint over a coat of primer complete all as specified. |
| 42 | M&L for complete removal of existing treatment from wall surfaces |
| 43 | M&L for preparation of old plastered wall surfaces and applying two coats of cement based paint over a coat of primer complete all as specified. |
| 44 | M&L for preparation of old plastered surfaces and applying one coat of cement based paint complete all as specified. |
| 45 | Demolition and breaking up drain pipes Internal dia of pipe in 100 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar |
| 46 | Demolition and breaking up drain pipes Internal dia of pipe in150 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar |
| 47 | M&L PCC (1:3:6) Type C-2 Concrete bed to drain pipe including forming cradles in against the side or pipe after they are laid and tested for 100 mm dia pipe. |
| 48 | M&L PCC (1:3:6) Type C-2 Concrete bed to drain pipe including forming cradles in against the side or pipe after they are laid and tested for 150 mm dia pipe. |
| 49 | M&L for 100mm dia DWC (Double Wall Corrugated) HDPE pipe, class SN4, laid and jointed complete with collars. |
| 50 | M&L for 150mm dia DWC (Double Wall Corrugated) HDPE pipe, class SN4, laid and jointed complete with collars. |
| 51 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel for 100 mm dia(1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required. |
| 52 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel for 150 mm dia(1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required. |
| 53 | Excavation in trenches n.exc 1.5 m in depth and 1.5 m in width for foundation etc and getting out in soft/ loose soil. |
| 54 | Returning filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil. |
| 55 | Removing excavated materials not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soil. |
| 56 | S&F in repairs PVC (SWR) pipes 110 mm single socketed in any length with rubberring joints, laid in trenches or in floors |
| 57 | Description as per Ser item No 56 above but 75mm bore |
| 58 | S&F in repairs PVC (SWR) pipes 75 mm single socketed in any length with rubberring joints fixed to wall complete. |
| 59 | S&F PVC bends any radius 110 mm dia |
| 60 | Description as per Ser item No 59 above but 75mm bore |
| 61 | S & F 110mm PVC (SWR), junction single, (Single T) equal or unequal |
| 62 | S & F 75mm PVC (SWR), junction single, (Single T) equal or unequal |
| 63 | S & F PVC 75mm(SWR) vent cowl |
| 64 | M&L for preparation of old plastered/concrete/AC surfaces of any description, not otherwise described over 10 Cm width or girth & applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 65 | Taking down carefully exising unserviceable copper/aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed. |
| 66 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with GI sunken /surface boxes 1.2 mm thick, 60 mm deep with earth dolly duly as per site requirment , covered with modular white cover plate with frame suitable for modular switches, or PVC surface mounted modular box, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSHH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- (Note- Modular cover plate and base plate of any module with all fittings are included in point wiring.) Contractor should make good even distributed wall/surface as before. |
| 67 | (a) One light point controlled by one, one way switch 5 Amps |
| 68 | (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 69 | (c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 70 | (d) One bell point controlled by one, bell switch 5 Amps |
| 71 | (e) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 72 | Description all as per Ser item No 66 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 73 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with mild steel sunken boxes 1.6 mm thick, 60 mm deep with earth dolly duly, covered with hylem sheet cover 3 mm thick, ISI marked suitable for fixing of switches, fan regulators and sockets including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSHH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-(Contractor should make good even distributed wall/surface as before.) |
| 74 | (a) One light point controlled by one, one way switch 5 Amps |
| 75 | (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 76 | (c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 77 | (d) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 78 | Description all as per Ser item No 68 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 79 | S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 80 | S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 81 | S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp (set of 3 switches) , including junction box complete all as specified. JAQUAR Cat Part No SWG-GRY-GL16A3G01 , Havells AHLPLCGV03, Anchor 21328WH |
| 82 | S & F for Modular Switch Socket combination outlet multipurpose having provision for 3 pin, 15/16 Amp including junction box complete all as specified. JAQUAR Cat Part No SKG-GRY-GL16ASC1GS1, Havells ACGPTOFV03, Anchor 85366990 |
| 83 | S & F ceiling fan regulator rotary type heavy duty suitable to work on 230 volts AC supply including junction box and removal of old unserviceable one complete all as specified. JAQUAR Cat Part No SWG-GRY-GL1ARFSS, Havells ACYRFHG008, Anchor 84149030 |
| 84 | S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 85 | S & F for Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 86 | S & F ceiling fan regulator socketed, step type, 1 Module heavy duty suitable to work on 230 volts AC supply including removal of old unserviceable one complete all as specified. |
| 87 | S & F ceiling fan regulator socketed, step type, 2 Module heavy duty suitable to work on 230 volts AC supply including removal of old unserviceable one complete all as specified. |
| 88 | S & F for Bell push modular 6 Amps single module complete all as specified. |
| 89 | Suply and fix for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed |
| 90 | S & F for Lamp holder, PVC body suitable for batten fitting completes all as specified. |
| 91 | S & F for Ceiling rose, surface Bakelite suitable ISI marked for batten fitting complete all as specified |
| 92 | S & F for Switch piano flush type, single pole, one way, and 6 Amp complete all as specified. |
| 93 | S & F for Socket outlet multipurpose having provision for 3 pin, 6 Amp and 2 pin, 6 Amp, piano flush type complete all as specified. |
| 94 | S&F in replacement of switch socket combinations flush 5 Amp 5 pin competeI ,ISI marked |
| 95 | S&F switch socket combination 2 in 1, 3 pin, 15 amp multipurpose, flush type, all as specified and as directed |
| 96 | S & F for wall mounted LED tube light fitting not less than 22 W, 220V, 4000K batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Cat Part phillips BN021 LED22S 4000K PSU GR, Jaquar BTI-WHT-LGLZU1X022XW or Havells- LINEBS22WLED865SPCWH |
| 97 | S & F for wall mounted LED tube light fitting not less than 22 W, 220V, 6500K batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Cat Part phillips BN021 LED22S 6500KPSU GR, Jaquar BTI-WHT-LGLZU1X022XW or Havells- LUMILINEBS22WLED865SPCWH |
| 98 | S & F for LED lights fitting not less than 20 W, 220V, AC box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. Cat Part No Bajaj BCLSB 20 WH, Jaquar BTI-WHTLTBL01X020XC or crompton TCS-109-20-65-SL-DP-NWH. |
| 99 | S & F for LED 10 watts batten with decorative end caps complete all as specified and as directed. |
| 100 | S & F for Highly efficient LED Bulbs, 10 W, of make Bajaj, Havells, HPL complete all as specified and directed |
| 101 | Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed. |
| 102 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :- (Note- Modular cover plate and base plate of any module with all fittings are included in point wiring.) Contractor should make good even distributed wall/surface as before to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :- |
| 103 | (a) One light point controlled by one, one way switch 5 Amps |
| 104 | (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 105 | (c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 106 | (d) One bell point controlled by one, bell switch 5 Amps |
| 107 | (e) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 108 | Description all as per ser item No 93 here in before but using 2.5 sq mm single core copper conductor FRLSHH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm PVC insulated copper conductor FRLSHH cable as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 109 | S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp (set of 3 switches) , including junction box complete all as specified. JAQUAR Cat Part No SWG-GRY-GL16A3G01 , Havells AHLPLCGV03, Anchor 21328WH |
| 110 | S & F for Modular Switch Socket combination outlet multipurpose having provision for 3 pin, 15/16 Amp including junction box complete all as specified. JAQUAR Cat Part No SKG-GRY-GL16ASC1GS1, Havells ACGPTOFV03, Anchor 85366990 |
| 111 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 4.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size concealed in wall etc including one run of PVC insulated 4 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 4 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 112 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified. |
| 113 | S & F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts AC supply including removal of old unserviceable one complete all as specified. |
| 114 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 115 | S & F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 116 | S & F for sheet metal enclosure MCB DB VTPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 117 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 118 | S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 119 | S & F MCCB TPN 415 volts 25 KA suitable for fixing on DB of capacity 100 Amps with extended terminals complete all as specified. |
| 120 | S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 121 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 122 | S & F for MCB Single pole and neutral rated capacity 40-63 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 123 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 124 | S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed. |
| 125 | Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 1.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed. |
| 126 | Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 2.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed. |
| 127 | Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 4 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed. |
| 128 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated frlshH cable with stranded copper conductor of size 4.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC casing caping of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size in wall etc including one run of PVC insulated 4 Sqmm (nominal area) stranded copper conductor frlshH cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 4 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 129 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC casing caping of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 130 | S & F for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 131 | S & F for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. Please Enable Macros to View BoQ information |