| 1 | Visit to the site of DG sets of 5 KVA capacity installed at various locations of Air Force Station Bareilly. Checking and testing of DG set Including Engine, alternator, AMF panel, Body & chases complete for its proper functioning and making a list of repairs / replacements required to be carried out in DG sets. Carrying out general servicing and minor repairs and / or replacements all as directed including following jobs and the like as directed :- (i) Checking and cleaning of diesel filters & oil filters and making a list of filters required to be replaced (ii) Checking of engine oil level and intimating the quantity of oil required for topping, if any (iii) Checking, cleaning and servicing including oiling & greasing of engine and making list of repairs / replacements required, if any (iv) Checking, cleaning, watering & general servicing of alternator battery including tightening of nuts, bolts, lugs and the like. Also making a list of repairs / replacements required, if any (v) Checking the earthing connections of neutral and body of DG set, tightening of connections and making a list of repairs / replacements required, if any all as specified.(Note - I. Rates quoted by the tenderer are also deemed to be included in the cost of S&F in replacement of minors parts like nuts, bolts, washers, lugs, etc., supply and applying oil & greasing and minor repairs to DG set.II. The work under this item is to be carried out periodically as directed by the Engineer in charge.III. List of repairs / replacements prepared by the contractor shall be submitted to the Engineer in charge for verification |
| 2 | All as per item No. 1.00 above but for DG set of capacity 20 KVA |
| 3 | All as per item No. 1.00 above but for DG set of capacity 30 to 40 KVA |
| 4 | All as per item No. 1.00 above but for DG set of capacity 50 KVA |
| 5 | All as per item No. 1.00 above but for DG set of capacity 62.50 / 63 KVA |
| 6 | All as per item No. 1.00 above but for DG set of capacity 75 KVA |
| 7 | All as per item No. 1.00 above but for DG set of capacity 100 KVA |
| 8 | All as per item No. 1.00 above but for DG set of capacity 125 KVA |
| 9 | All as per item No. 1.00 above but for DG set of capacity 160 KVA |
| 10 | All as per item No. 1.00 above but for DG set of capacity 200 KVA |
| 11 | All as per item No. 1.00 above but for DG set of capacity 250 KVA |
| 12 | All as per item No. 1.00 above but for DG set of capacity 320 KVA |
| 13 | M&L for preparing old painted surface of DG sets of capacity 100 to 320 KVA including engine, alternator, body & chases by thoroughly cleaning the surfaces to remove dirt, dust, rust flakes and paint flakes using wire brush or sand papers, damp cloth or as directed. Priming the surface with anti corrosive primer using suitable sprayers and applying automotive paint using sprayer till glossy finish is obtained complete all as per manufacturer's instructions and as directed by Engineer-in-Charge. Make of paint - Asian / Berger / Nerolac) |
| 14 | Supply only in replacement of lead Acid battery 88 AH,12 Volt, maintenance free battery of 2 years warranty for DG sets. Make :- Exide / AMORON / PRESTOLITE |
| 15 | All as per item No. 14.00 above but 150 AH,12 Volt. |
| 16 | All as per item No. 14.00 above but 180 AH,12 Volt. |
| 17 | Servicing and calibration FIP (Fuel injection pump) & nozzles including replacement of all parts like nuts, bolts, washers, bearing plunger, delivery valve, seat washer, gasket, control rod, governer spring etc for DG set upto 25 KVA capacity all as specified. |
| 18 | All as per item No. 17.00 above but for 30 to 50 KVA. |
| 19 | All as per item No. 17.00 above but for 62.50 to 75 KVA. |
| 20 | All as per item No. 17.00 above but for 100 KVA. |
| 21 | All as per item No. 17.00 above but for 125 to 320 KVA. |
| 22 | M&L for taking out Radiator of DG set 30 KVA to 63 KVA for repair, welding, brazing, leak testing, descaling & refixing to DG set to its original position and testing complete all as directed. |
| 23 | M&L for taking out Radiator of DG set 100 KVA to 320 KVA for repair, welding, brazing, leak testing, descaling & refixing to DG set to its original position and testing complete all as directed. |
| 24 | Repairing to alternator for DG set capacity upto 5 KVA, charging of battery complete overhauling & servicing of the alternator including repair / replacement of unserviceable parts, assembling complete and testing all as directed. |
| 25 | All as per item No. 24.00 above but for 20 to 40 KVA. |
| 26 | All as per item No. 24.00 above but for 50 KVA. |
| 27 | All as per item No. 24.00 above but for 62.50 / 63 KVA. |
| 28 | All as per item No. 24.00 above but for 75 KVA. |
| 29 | All as per item No. 24.00 above but for 100 KVA. |
| 30 | S&F in replacement of Solenoid Switch & Relay card for 250 KVA to 320 KVA DG set and testing complete for proper functioning. |
| 31 | S&F in replacement of Solenoid Switch & Relay card for 100 to 200 KVA DG set and testing complete for proper functioning. |
| 32 | S&F in replacement of Solenoid Switch & Relay card for 62.5 to 75 KVA DG set and testing complete for proper functioning. |
| 33 | S&F in replacement of Solenoid Switch & Relay card for 50 KVA DG set and testing complete for proper functioning. |
| 34 | S&F in replacement of 12 volt Actuator suitable for 5 to 125 KVA DG set and testing complete for proper functioning. |
| 35 | S&F in replacement of 12 volt Electrical Gov Card suitable for 5 to 125 KVA DG set and testing complete for proper functioning. |
| 36 | S&F in replacement of single phase preventor complete all as specified. |
| 37 | S&F in replacement of PLA relay complete all as specified. |
| 38 | S&F in replacement of 3 pole Power Contactor ML-1.5,10 to 25 Amp,415 volt complete all as specified. |
| 39 | S&F in replacement of 3 pole power Contractor ML-2,32/40 Amp,415 volt complete all as specified. |
| 40 | S&F in replacement of fan hub complete suitable for 250 KVA to 320 KVA DG Set. |
| 41 | S&F in replacement of fan hub complete suitable for 100 KVA to 200 KVA DG Set. |
| 42 | S&F in replacement of Fan Hub complete suitable for 5 KVA to 62.50 KVA DG Set. |
| 43 | S&F in replacement of 12 volt Actuator suitable for 160 to 320 KVA DG set and testing complete for proper functioning. |
| 44 | S&F in replacement of 24 volt Electrical Gov Card suitable for 160 to 320 KVA DG set and testing complete for proper functioning. |
| 45 | Removing, transporting to workshop, repairing & servicing of self starter of DG set ranging from 35 KVA to 200 KVA including replacement of parts such as washer, nut, bolts, bush, Solenoid, rotor etc, reassembling and testing complete as directed. |
| 46 | Descaling of water jacket of engine by using descaling solution with pressure circulation pump, leak testing, soldering, brazing, checking for leaks and recirculating with clear water for 20 KVA DG set complete all as directed. |
| 47 | All as per Item No. 46.00 above but for 30 to 40 KVA DG Set. |
| 48 | All as per Item No. 46.00 above but for 50 DG Set. |
| 49 | All as per Item No. 46.00 above but for 62.50 / 63 KVA DG Set. |
| 50 | All as per Item No. 46.00 above but for 75 DG Set. |
| 51 | All as per Item No. 46.00 above but for 100 DG Set. |
| 52 | All as per Item No. 46.00 above but for 125 DG Set. |
| 53 | All as per Item No. 46.00 above but for 160 DG Set. |
| 54 | All as per Item No. 46.00 above but for 200 DG Set. |
| 55 | All as per Item No. 46.00 above but for 250 to 320 KVA DG Set. |
| 56 | S&F in replacement of battery auto cable suitable for 180 Amps 12 volts |
| 57 | S&F in replacement of \\"V\\" belt for Radiator fan upto 25 KVA DG Set. |
| 58 | All as per Item No. 57.00 above but for 60 to 100 KVA DG Set. |
| 59 | All as per Item No. 57.00 above but for 160 / 320 KVA DG Set. |
| 60 | S&F for Engine Oil (20W 40) all as specified. |
| 61 | S&F for pre / ready mix coolant for DG Set all as specified. |
| 62 | M&L for cleaning of Diesel Tank of DG Set including painting with one coat of oil paint & writing with paint as \\"Tank Cleaned on Date……….\\" all as directed by Engineer-in-Charge. |
| 63 | Supply only in replacment of Diesel filter suitable for 5 KVA DG Set capacity all as directed. |
| 64 | All as per Item No. 63.00 above but for 20 KVA DG Set |
| 65 | All as per Item No. 63.00 above but for 30 to 40 KVA DG Set |
| 66 | All as per Item No. 63.00 above but for 50 KVA DG Set |
| 67 | All as per Item No. 63.00 above but for 62.5 / 63 KVA DG Set |
| 68 | All as per Item No. 63.00 above but for 75 KVA DG Set |
| 69 | All as per Item No. 63.00 above but for 100 KVA DG Set |
| 70 | All as per Item No. 63.00 above but for 125 KVA DG Set |
| 71 | All as per Item No. 63.00 above but for 160 KVA DG Set |
| 72 | All as per Item No. 63.00 above but for 200 to 320 KVA DG Set |
| 73 | Supply only in replacement of Oil filter suitable for 5 KVA DG Set all as directed. |
| 74 | All as per Item No. 73.00 above but for 20 KVA DG Set |
| 75 | All as per Item No. 73.00 above but for 30 to 40 KVA DG Set |
| 76 | All as per Item No. 73.00 above but for 50 KVA DG Set |
| 77 | All as per Item No. 73.00 above but for 62.5 / 63 KVA DG Set |
| 78 | All as per Item No. 73.00 above but for 75 KVA DG Set |
| 79 | All as per Item No. 73.00 above but for 100 KVA DG Set |
| 80 | All as per Item No. 73.00 above but for 125 KVA DG Set |
| 81 | All as per Item No. 73.00 above but for 160 KVA DG Set |
| 82 | All as per Item No. 73.00 above but for 200 to 320 KVA DG Set |
| 83 | Supply only in replacement of Air filter suitable for 5 KVA DG Set all as directed. |
| 84 | All as per Item No. 83.00 above but for 20 KVA DG Set |
| 85 | All as per Item No. 83.00 above but for 30 to 40 KVA DG Set |
| 86 | All as per Item No. 83.00 above but for 50 KVA DG Set |
| 87 | All as per Item No. 83.00 above but for 62.5 / 63 KVA DG Set |
| 88 | All as per Item No. 83.00 above but for 75 KVA DG Set |
| 89 | All as per Item No. 83.00 above but for 100 KVA DG Set |
| 90 | All as per Item No. 83.00 above but for 125 KVA DG Set |
| 91 | All as per Item No. 83.00 above but for 160 KVA DG Set |
| 92 | All as per Item No. 83.00 above but for 200 to 320 KVA DG Set |
| 93 | Supply only in replacement of Hose Pipe Set suitable for 20 KVA DG Set all as directed. |
| 94 | All as per Item No. 93.00 above but for 30 KVA DG Set |
| 95 | All as per Item No. 93.00 above but for 40 KVA DG Set |
| 96 | All as per Item No. 93.00 above but for 50 KVA DG Set |
| 97 | All as per Item No. 93.00 above but for 63 / 62.5 KVA DG Set |
| 98 | All as per Item No. 93.00 above but for 75 KVA DG Set |
| 99 | All as per Item No. 93.00 above but for 100 KVA DG Set |
| 100 | All as per Item No. 93.00 above but for 125 KVA DG Set |
| 101 | All as per Item No. 93.00 above but for 160 KVA DG Set |
| 102 | All as per Item No. 93.00 above but for 200 to 320 KVA DG Set |
| 103 | S&F in replacement of AVR suitable for 50 KVA DG Set all as directed. |
| 104 | All as per Item No. 103.00 above but for 62.5 to 125 KVA DG Set |
| 105 | All as per Item No. 103.00 above but for 160 KVA to 320 KVA DG Set |
| 106 | Supply only in replacement of battery lugs all as specified. |
| 107 | S&F in replacement of Ignition Switch of DG Set all as directed. |
| 108 | S&F in replacement of Self Starter 5 to 50 KVA DG Set 12 Volt. Make: Lucas / AutoLak / Delgo |
| 109 | S&F in replacement of Self Starter 62.5 to 100 KVA DG Set 12 Volt Make: Lucas / AutoLak / Delgo |
| 110 | S&F in replacement of Self Starter 125 to 160 KVA DG Set 12 Volt Make: Lucas / AutoLak /Delgo |
| 111 | S&F in replacement of Self Starter 200 to 320 KVA DG Set 24 Volt Make: Lucas / AutoLak / Delgo |
| 112 | S&F in repair / replacement wiring of DG Set 5 to 50 KVA all as directed by Engineer-in-Charge. |
| 113 | S&F in repair / replacement wiring of DG Set 62.5 to 100 KVA all as directed by Engineer-in-Charge. |
| 114 | S&F in repair / replacement wiring of DG Set 125 to 320 KVA all as directed by Engineer-in-Charge. |
| 115 | Supply only in replacement of Battery Charger 10 Amp for 12 Volt battery all as directed by Engineer-in-Charge. |
| 116 | Supply only in replacement of Battery Charger 10 Amp for 24 Volt battery all as directed by Engineer-in-Charge. |
| 117 | S&F in replacement of water pump complete for 30 to 320 KVA DG Set all as directed by Engineer-in-Charge. |
| 118 | S&F in replacement of Diesel Pipe Filter to Pump for DG Set all as directed by Engineer-in-Charge. |
| 119 | S&F in replacement of Diesel Pipe Filter to Tank for DG Set all as directed by Engineer-in-Charge. |
| 120 | S&F in replacement of Radiator for 50 to 100 KVA capacity DG Set all as directed by Engineer-in-Charge. |
| 121 | S&F in replacement of Radiator for 125 to 320 KVA capacity DG Set all as directed by Engineer-in-Charge. |
| 122 | S&F in replacement of DG Set power controller upto 50 KVA capacity DG Set all as directed by Engineer-in-Charge as per existing. |
| 123 | S&F in replacement of DG Set power controller for 62.5 to 125 KVA capacity DG Set all as directed by Engineer-in-Charge make as per existing. |
| 124 | S&F in replacement of DG Set power controller for 160 KVA to 320 KVA capacity DG Set all as directed by Engineer-in-Charge make as per existing. |
| 125 | Repairing to alternator complete overhauling & servicing of the alternator of DG set of capacity 125 KVA including repair / replacement of unserviceable parts, assembling complete and testing all as directed. |
| 126 | All as per Item No. 125.00 above but for DG set of capacity 160 KVA |
| 127 | All as per Item No. 125.00 above but for DG set of capacity 200 KVA |
| 128 | All as per Item No. 125.00 above but for DG set of capacity 250 KVA |
| 129 | All as per Item No. 125.00 above but for DG set of capacity 320 KVA Please Enable Macros to View BoQ information |