| 1 | Item Rate BoQ 82556/E8 BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE JAIPUR Name of Work: PROVISION OF VRF TYPE AIR CONDITIONING PLANT IN COMD MESS AT ZONE-I AREA AT JAIPUR MIL STN UNDER GE (SOUTH) JAIPUR CA NO: CWE/JPR(S)- OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # NUMBER # SNo Item Description Item Code / Make Qty Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Rate in Figure Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes Rate in Words Total Amount |
| 2 | Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes, laying cables erecting of poles / struts/stays etc n.exe 10 Sqm on plan not exceeding 1.5 metre in depth and getting out in any type of soil complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in any type of soil complete all as specified and directed. |
| 4 | Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point complete all as specified and directed. |
| 5 | M&L for laying of bricks subclass ‘B’ old size laid flat perpendicular to the direction of cable for protection of cable complete all as specified and directed. |
| 6 | M&L for dry river sand filling in trenches as cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified and directed.Note :- Punned thickness only shall be measured and paid. |
| 7 | Supplying, laying, connecting and testing in trenches, under floors/ roads or on walls Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armored, electric power cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade, of size 185 Sqmm, 3.5 Core complete all as specified and directed. |
| 8 | Supply and laying of GI pipe, size 100 mm dia light grade fixed on poles, walls or laid in trench etc. with all fittings for cable protection complete all as specified and directed. |
| 9 | Material and labour for earthing with galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 25 mm x 4 mm by means of GI Welding made out of galvanised iron mild steel and 40 mm dia GI pipe \\"light grade\\" for protection of earth lead, medium grade and earth plate surrounded by packed layer of coal and common salt, 15cm thick all around bottom and top, watering pipe of 20 mm bore of light grade with funnel all as shown in electrical plate No 3 of SSR Part-I (2009) and connecting to earthing test point, main switch board, transformer neutral and testing on completion as directed including earthing pit in PCC (1:3:6) type C-1, pre-cast reinforced cover with MS XPM Jalli, RCC 1:1.5:3 cover slab of size 300 x 300 x 100 mm with one handle made out of 8 mm dia round bar, wire mesh and testing complete all as specified and as directed.Note: (i) Cost of GI earth Strip and GI protection pipe upto 7.5mtr length shall deemed to be included in the rate quoted for this item.(ii) The unit rate shall also includes for Wire mesh, funnel, excavation.returninng & filling. PCC chamber pit,RCC cover & test point.(iii) If the desired earth resistance is not achieved during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissible. |
| 10 | Supply, installation testing & commissioning of factory made LT feeder pillar box out door type fabricated with 3.15 mm thick CRCA sheet, totally enclosed type, dust & vermin proof (IP 54 protection) with front & rear side openable double door type with hinged shutter with suitable locking arrangement and angle iron legs of size 50 mm x 50 mm x 6 mm and front openable shutters for each MCCB having spreader links with rotary handle hinges on one side, and other side having insulated Copper bus bar of 600 Amps rating ,3 phase, 415 Volts, 50 C/S 4 wire system, pre-wired complete with appropriately sized PVC insulated copper conductors, including making electric connection complete by means of suitable size copper lugs , nuts , bolts , washers etc. with cable entry provision, having opening at bottom for entry of outgoing / incoming cables, complete with grouting on floor / brick work with comprising of the following accessories:- (a) MCCB 4 pole,415 V, 320 Amps, adjustable thermal magnetic type, breaking capacity 36 KA - 01 No. (b)Ammeter 0-200 Amps digital type with suitable type of CT - 01 No(c) Voltmeter digital type 0-500 Volts -01No(d) Three indication led lamps for three phases complete with protection type fuses-01 SetOUTGOING(a) MCCB 4 pole,415 V, 250 Amps, breaking capacity 25 KA - 02 Nos (01 Working &01 Standby)NOTE : Cost including necessary Earthworks, PCC foundation as manufacturer's design, connecting loads, lugs, nuts, bolts, washers, required for cable connection, etc. shall deem to be included in quoted Rate. |
| 11 | Dismantling and refixing of existing ceiling light round/square type any size and any wattage including disconnection and reconnection from existing point wiring complete all as specified and directed. |
| 12 | Taking down cement plaster from brick walls of any description, racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 13 | M&L for rendering 15mm thick in cement mortar (1:6) on any face of brick walls or concrete surfaces, surfaces finished even and fair without using extra cement complete all as specified and directed. |
| 14 | M&L for preparation of newly plastered surface of wall and applying 2 mm thick putty to make the entire surface free from undulations and finally applying two coats of oil bound distemper complete all as specified and directed. |
| 15 | S&F fibre mesh over of beam, column with brickwork to repair existing cracks after opening up it in V-groove manner by using mechanical cutter, properly cleaning the same by compressed air to remove loose dust, dirt etc and filling crack seal compound complete all as specified and directed. |
| 16 | M&L for complete removal of existing treatment and applying a coat of wall care putty on wall putty to make the entire surface free from undulations and finally applying two coats of oil bound distemper complete all as specified and directed. |
| 17 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness incl cover fillets etc complete all as specified and as directed. |
| 18 | Supply and fix POP false ceiling using 10-12mm thick board fixed on framework of GI channels with SS wire mesh and hangers hanged over ceiling with suitable GI wiring and dash fasteners and bolts including two coat of OBD complete all as specified and directed. (Note- False ceiling has to be fixed over a ceiling height of 4.0 to 4.50 mtr) |
| 19 | Complete removal of existing treatment over wall and applying 2mm thick wall care putty and finally apply texture paint of any colour and pattern directed by Engineer in Charge complete all as specified and as directed. |
| 20 | M&L for applying smartcare Hydroloc damp proof in two coats over old or newly plastered surfaces including preparation of surfaces for treating dampness and efflorescence as per manufacturer's instruction complete all as specified and as directed. |
| 21 | Taking down chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking off shutter from the frame) and removing from site complete all as specified and directed. |
| 22 | S&F 12 mm thick toughen glass shutters (single leg openable type), with diamond polished, tinted clear glass including all hardware fittings detailed as under, fixed in position as per manufacturer instruction complete all as specified and as directed by Engr in charge.(a) Stainless steel top patch (Cat No EPF-701) 01 Set.(b) Stainless steel top pivoted (Cat No EPF-712) 01 Set.(c) Stainless steel bottom patch (Cat No EPF-702) 01 Set.(d) Glass to wall/glass to glass Stainless Steel lock (cat No EPF-799) 01 No(e) Stainless steel floor door spring (Cat No FH-ECO-842) 01 Set.(f) Stainless Steel Handle 300 mm size (Cat No ESBH -011) - 2 Nos For Each shutterNote:- Cat No mention above for Hardware fitting are of make ENOX, contractor may use similar type hardware fitting of make DORMA / OZONE or Equivalent in list of Makes. |
| 23 | Design, supply, installation, testing and commissioning of VRF type AC plant for the rooms as per drawing including design by of outdoor unit, Indoor units, duct, pipe, supply air grill, return air grill damper and fire damper etc and all other allied items.The scope of work will include following major items: -1. Refrigerant pipes:- Supply, installation, testing and commissioning of copper refrigerant piping for interconnection between each set of indoor units and outdoor units as per design prepared and any other item to make system complete duly insulated with closed cell elastomeric nitrile rubber tubular insulation complete all as per approved OEM instructions, as specified and directed ”. The work shall be carried out by OEM or authorised dealer of OEM as per the drawings submitted by contractor and duly approved by Garrison Engineer. The unit shall be complete with factory wiring, refrigerant charge, and compatible for integration with BMS. 2. Outdoor Unit:- Supplying, installing, testing and commissioning of air cooled 100% inverter single / multiple compressor based , non CFC refrigerant based variable refrigerant flow (VRF) modular type air conditioning system, suitable to operate at 400 V ±10%, 50 Hz electric supply , suitable for multi indoor units with external condensing units, copper refrigerant pipe, full charge of refrigerant with additional top up if required, drain pipe, transmission cum control wiring cordless remote controls, MS slotted angle irons, provision of winter heating arrangement (Heat recovery Ventilation System) ,etc , suitable for Jaipur condition without tripping including all accessories as specified below for maintaining inside temperature (22±2) Degree Celsius considering weather condition of Jaipur. |
| 24 | Floor mounted Outdoor top discharging type condensing units equipped with Micro-processor control panel, sub cooler, accumulator, hermetically sealed highly efficient 100% inverter type scroll / Screw compressor, low noise condenser fan with DC motor, auto check function for connection error, auto address setting, vibration isolator and all the necessary accessories for proper functioning of the units. Capacity of Outdoor unit to be design by the bidder tentative load is not less than 110 TR.Supplying, installing, testing and commissioning of air cooled 100% inverter single / multiple compressor based , non CFC refrigerant based variable refrigerant flow (VRF) modular type air conditioning system, suitable to operate at 400 V ±10%, 50 Hz electric supply , suitable for multi indoor units with external condensing units, copper refrigerant pipe, full charge of refrigerant with additional top up if required, drain pipe, transmission cum control wiring cordless remote controls, MS slotted angle irons, provision of winter heating arrangement (Heat recovery Ventilation System) ,etc , suitable to operate at 50 degree C without tripping including all accessories as specified below for maintaining inside temperature (22±2) Degree Celsius considering weather condition of jaipur. Size and type of indoor unit to be designed by bidder and sumiited to GE for approval. |
| 25 | 3.Indoor Units: -Design, Supply, installation, testing and commissioning of ceiling concealed high static ductable indoor units suitable for VRF system. Units shall have adjustable ESP up to 100 Pa. Cooling coil shall be made of copper tubes with aluminium fins, with hydrophilic coating. Unit shall be provided with washable synthetic filters, insulated drain pan, and low noise operation (<45 dB). The unit shall be suitable for false ceiling mounting and connected with supply and return air ducting. Each unit shall be complete with electronic expansion valve, fan motor, and wired controller. The unit shall be factory tested and fully compatible with VRF outdoor system are based on any other superior updated version. The No & type of Indoor units shall be selected based on the design submitted by Contractor.4.Drain Pipe: -Supply, installation, testing & commissioning of Rigid PVC Drain piping of 6 Kg/CM2 rating with insulated with 9mm thick nitrile foam rubber trenched on walls, ceiling suspended , hanged with all necessary clamps, saddles & supports.S&F flexible PVC drain piping of suitable dia for indoor units complete with necessary fittings viz elbow, tees reducers etc complete all as specified and directed. |
| 26 | Notes:- The work will be executed in two parts: -The Part-I includes (1) site survey, design of VRF type AC for the room as per the attached drawing. (2) Submission of design duly vetted by NIT or any govt Engineering college. (3) Approval of complete design from Accepting officer. Designing will include followings: -(a) Detail drawing of the plant. (b) Selection of capacity and type of indoor and outdoor units. (c) Design of all connected electrical wiring / distribution box and distribution panel. (d) Routing of cables and cables tray, drain pipe etc. (Tentative Time schedule :- 0 to 4 week)The Part-II involves: - Supply, installation, testing and commissioning of VRF type AC plant as per the approved design and as directed by Engr-in-Charge. (Tentative Time schedule :- 0 to16 week)Note: The completion of work will be issued by GE on completion of both the parts. |
| 27 | Schedule of Credit Total in Figures 0.0 0.0 -20425.0 Quoted Rate in Figures Select 0.0 0.0 Zero Only 0.0 Quoted Rate in Words INR Minus Twenty Thousand Four Hundred & Twenty Five Only Please Enable Macros to View BoQ information |