| 1 | Providing &Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by the Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 2 | One day & week reserve (digital type ) |
| 3 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. Rates are exclusive of GST. |
| 4 | Above 5 HP and up to 10 HP |
| 5 | Above 10 HP and up to 15 HP |
| 6 | Above 15 HP and up to 20 HP |
| 7 | Above 20 HP and up to 30 HP |
| 8 | SITC STAR DELTA Starter type LT Panel of following rating: all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) etc. and 100A/ 125A ,TPN, Aluminium Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-InCharge. Rates are exclusive of GST. |
| 9 | STAR DELTA STARTER 15.0 KW (20.0 HP) : For 2 motors (1 W+ 1S) I/C- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1), Spreaders (2),Extended Rotary Handle (1), Analog Voltmeter 96*96mm ( 0-500V) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 100/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 63A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (12-18A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2) |
| 10 | STAR DELTA STARTER 18.5 KW (25.0 HP) - : For 2 motors (1 W+ 1S) I/C- MCCB 125A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (16-24A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 10 Kvar (2), S/D Timer(2) |
| 11 | STAR DELTA STARTER 22.0 KW (30.0 HP) - : For 2 motors (1 W+ 1S) I/C- MCCB 125A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 40A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (23-32A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 12.5 Kvar (2), S/D Timer(2) |
| 12 | S SITCof Drawout type3/4poledoor interlockAir Circuit Breaker (ACB) as conforming to IS/IEC60947P- 2 :2003 in existing LTpanel suitable for LT installation 440 V, 50 Hz and having adjustable over load short InstantaNeous,earthfault 4 5 6 S SITCof Drawout type3/4poledoor interlockAir Circuit Breaker (ACB) as conforming to IS/IEC60947P- 2 :2003 inexisting LTpanel suitable for LT installation 440 V, 50 Hz and having adjustable over load short-circuit, Instantaneous,earthfault (LSIG)with (LSIG)with 1 separate se indication for each type of fault shall confirm to EMI/ EMC test , LCD/LED display, last 10 triphistory, provision of ZSI, Communication, Power metering module, Thermalmemory, trip free me chanisum, suitable for ambient 50 degree and utilization catagary B. Inbuilt electrical & mechanical antipumping feature,100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, reaking capacity Icu=Ics=Icw(1sec) ,Uimp-12KV,break time not more then 25ms. Provision for electrical &mechanical interlock betweenACBs, LED indication for each type of fault shall confirm to EMI/ EMC test , LCD/LED display, last 10 triphistory, provision of ZSI, Communication, Power metering module, Thermalmemory, trip free me chanisum, suitable for on catagary B. Inbuilt electrical & mechanical antipumping feature,100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, reaking capacity 12KV,break time not more thenovision for electrical &mechanical interlock betweenACBs, Min.electrical Min.electrical operation operation 10000 upto2000A rating and 5,000 for 2500A to 4000A. including making connections, testing etc. asrequired. OEM shall have submit NABL / CPRI / ERDA accrediated test certificate before execution. All as per pre approved by Engineer incharge. Foradditional technical parameters of product / work refer Annexure 'A' 10000 upto2000A rating and 5,000 for 2500A to 4000A. including making connections, testing etc. asrequired. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer incharge. Foradditional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 13 | Microprocessor based release Draw out type (Manual charging type ) 3Pole |
| 14 | 1000 A Rating , 50 Ka |
| 15 | 1250 A Rating , 50 Ka |
| 16 | 1600 A Rating , 50 Ka |
| 17 | 2000 A Rating , 50 Ka |
| 18 | 2500 A Rating , 50 Ka Please Enable Macros to View BoQ information |