| 1 | Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with HDPE, U/UTP (Unscreened/Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Outdoor Cable as per latest ammendments of ANSI/TIA/EIA-568 C.2 & ISO/IEC 11801 2nd Ed, The copper conductors should be balanced twisted in pairs, seperated by a cross divider & protected by LSZH PVC outer jacket of UV resistant. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. Should meet IEEE 802.3af & IEEE 802.3at for POE applications. Cable Should support Ethernet 10GBASE-T according to the standards. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 2 | \\"Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"\\"A\\"\\" attached with this BSR . Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 3 Mtr\\" |
| 3 | \\"Supply, Drawing and Testing, of stranded Single mode (9/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"\\"A\\"\\" attached with this BSR . 6 Fiber\\" |
| 4 | \\"Supply, Installation, & Testing of Indoor duplex Singlemode patch cord (9/125 µm (OS1/OS2) made of glass fiber optic with LSZH jacket, F8 2.0x4.1 mm, yellow, singlemode G652.D (9/125 µm (OS1, OS2) Mounted on both sides with ST/E-2000/SC/LC/MT-RJ/PC type Duplex connectors in acc. with IEC 61754-20. Zirconia (ceramic) ferrule with a PC polished endface geometry, connectors should be tuned in accordance with IEC 61755-3-1 and qualified in acc. with IEC 61753-1 for category U (uncontrolled environment, duplex clip and white plastic dust cover, should comply to delta IL < 0.2 dB after 500 mating cycles, there should be an optional Visual coding, mechanical coding and lock protection on the patch cords which can be added on later stage. patch cords's performance should be acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, as per requirements.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"\\"A\\"\\" attached with this BSR . 1mtr.\\" |
| 5 | \\"Supply, Installation, & Testing of 19\\"\\" 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MTRJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"\\"A\\"\\" attached with this BSR . 6 Ports\\" |
| 6 | Supply, installation, Testing and Commissioning of 1000 base-LX/LH single mode/Multi mode fibre to 1000 base-T copper giga bit , Media Convertor complete as required complete in all respect. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 7 | \\"Fiber Fusion Splicing with OTDR Testing of Fiber Single/ Multi mode (per splice) of glass Fiber Optic Cable including cleaning the cable and making splice as per standard practice complete in all respect. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"\\"A\\"\\" attached with this BSR . 6 Fiber\\" |
| 8 | \\"Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2.5 Sqmm 3 Core\\" |
| 9 | \\"Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2.5 Sqmm 3 Core\\" |
| 10 | \\"Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Double pole MCB(With B/C curve tripping Characteristics) 0.5 A to 5 A rating\\" |
| 11 | \\"Providing & Fixing of din rail mounting surge protection device confirming to IEC 61643-11 for Type 1 + 2 protection and Maximum discharge current 50 kA with following configuration in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 1P + N\\" |
| 12 | \\"P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"\\"A\\"\\" attached with this BSR . 50mm\\" |
| 13 | \\"labour charges for Excavating trenches of required width for pipes dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr.: All kind of Soils\\" |
| 14 | SITC of Cutting back up surface up to 2 Mtr. Depth by digging by Bogie including all layers of crust for laying pipe line etc. and making good to original condition (excluding cost bitumen) |
| 15 | \\"Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"\\"A\\"\\" attached with this BSR . Poles with Octagonal Cross Section 7 Mtr.\\" |
| 16 | \\"Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , refer Annexure \\"\\"A\\"\\" attached with this BSR . Single arm overhang\\" |
| 17 | \\"Providing, laying and compacting plain/ reinforced cement concrete of specified grade in foundation/ levelling course/ pile cap using concrete mixer and vibrator complete including cost of form work, as per drawing and technical specifications and as per clause 1100, 1500,1700,2100 of MoRT&H specification including all scaffolding material, labour, machinery. PCC Grade M -25\\" |
| 18 | \\"Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e), (f) below :- (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts ( c) Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bol (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm (e) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book. (f) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"\\"A\\"\\" attached with this BSR . 25 mm thick and 3 Mtr. Long\\" |
| 19 | SITC SITC of 5MP Outdoor Motorised lens Bullet ANPR Camera as per Technical Specifications., complete in all respects including high-resolution surveillance performance; ONVIF compliant interoperability; low-light / IR imaging capability; IP66/IP67 weatherproof outdoor-rated enclosure; Ethernet surge protection and electrical safety complianceas per attached detail specification (Tender specific OEM MAF Mendatory). |
| 20 | SITC of the ANPR Software on camera edge, perpetual license with 3-year maintenance support as per the attached detailed specification. (Tender specific OEM MAF Mendatory) |
| 21 | SITC of the Unified Video Management Software Base Software License as per the attached detailed specification (Tender specific OEM MAF Mendatory). |
| 22 | SITC of the Unified Video Management Software Channel License as per the attached detailed specification (Tender specific OEM MAF Mendatory). |
| 23 | SITC of the Unified control command center software license with mission control function as per the attached detailed specification. |
| 24 | SITC of BTS RF Radio with 90 degree sector Antenna as per the attached detailed specification (Tender specific OEM MAF Mendatory). |
| 25 | SITC of RF P2P Radio as per the attached detailed specification (Tender specific OEM MAF Mendatory). |
| 26 | SITC Industrial, 5G- GSM, Dual SIM, 4xGiga Router Switch as per the attached detailed specification (Tender specific OEM MAF Mendatory). |
| 27 | SITC of Solar Power System with High Efficiency Mono PERC / TOPCon, High Efficiency Crystalline Silicon, Half-Cut, Bifacial, Light weight Aluminum frame rigid Solar Panel, 500w or higher, with Networked intelligent MPPT Charge controller, 24V, 100ah, intelligent BMS LiFePO4 Battery bank, Electrical and data cabling with support structure as per the attached detailed specification. |
| 28 | SITC of Industrial DC-UPS with Intelligent Security Power Supply (240W) for connected field devices on CCTV pole as per the attached detailed specification. |
| 29 | SITC of LiFePO4 Batteies 24V, 30AH as per the attached detailed specification. |
| 30 | SITC of ANPR, Video Management & Storage Appliance as per the attached detailed specification.\\"SITC of ANPR, VMS and control and command appliance;Form Factor: Tower/Rack type; Processor: Intel/AMD 12-Core proccessor; Memory: 64GB or heigher; SSD: 2X480 GB NVMe; Storage: 2X8TB HDD or heigher; Operating System: Windows 11 64 Bit or higher; Networkin: Min 1 x 1Gb Ethernet port; Power Supply: 800Watt or heigher; Graphic card: 12 GB RTX 5070 or heigher\\"; with 2 numbers of 24\\" LED monitor |
| 31 | Supply & Installation of UV-resistant Fiberglass (FRP/GRP) or Polycarbonate Outdoor Pole Mountable equipment Rack; Thermal Management: Diagonally opposed ventilation ports: one passive louver intake filter at the lower-left panel and one active 24 V DC forced-exhaust fan at the upper-right panel. The fan and intake assembly must provide an IP54 rating using washable, replaceable G3/G4 synthetic filter mats complete with fine internal stainless-steel insect mesh; Integrated Solar Shield / Sun Canopy to prevent solar thermal loading; with Heavy-Duty Pole Mount Kit external, rear-mounted vertical channel reinforcement brackets with Din Rail Manegement; Dimensions: Mini 600 mm× 400 mm × 200 mm; Active Environmental Management: Internal control via an adjustable mechanical DIN-rail thermostat (Normally Open contacts) configured to cycle the fan on only when internal temperatures exceed 35 °C; Mounting Configuration: Heavy-duty, rear-mounted vertical channel pole-mounting kit featuring stainless-steel worm-gear bands to secure the box without penetrating the internal rear backboard. |
| 32 | SITC of SD Card 128 GB Class-10 for local storage of ANPR Data at the Camera Edge |
| 33 | Integration, of ANPR Software, VMS Software, Control & Command Software, and Optimization of field devices. Please Enable Macros to View BoQ information |