| 1 | Excavating in trenches, in soft/loose soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables and pipes etc. not exceeding 10Sqm on plan and not exceeding 1.5m in depth and getting out complete all as specified and as direcetd. |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceding 25cm in soft/loose soil complete all as directed. |
| 3 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 4 | Taking up or down or out existing 100mm bore HDPE/PVC watermains (including all fittings) and removing from site complete all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 5 | Taking up or down or out existing 150mm bore HDPE/PVC watermains (including all fittings) and removing from site complete all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 6 | Taking up or down or out existing 200mm bore HDPE/PVC watermains (including all fittings) and removing from site complete all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 7 | Taking up or down or out existing 100mm bore Cast Iron (CI)/ Ductile Iron (DI)/ Mild Steel (MS)/Galvanised Iron (GI) watermains pipes (including all fittings),with spigot and socket ends and lead joints including burning out joints and recovering lead, and removing from site complete all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 8 | Taking up or down or out existing 150mm bore Cast Iron (CI)/ Ductile Iron (DI)/ Mild Steel (MS)/Galvanised Iron (GI) watermains pipes (including all fittings),with spigot and socket ends and lead joints including burning out joints and recovering lead and removing from site complete all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 9 | Taking up or down or out existing 15mm bore galvanised steel water tubing, alongwith connections complete and removing from site all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 10 | Taking up or down or out existing 20mm bore galvanised steel water tubing, alongwith connections complete all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 11 | Taking up or down or out existing 25mm bore galvanised steel water tubing, alongwith connections complete and removing from site all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 12 | Taking up or down or out existing 40mm bore galvanised steel water tubing, alongwith connections and removing from site complete all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 13 | Taking up or down or out existing 50mm bore galvanised steel water tubing, alongwith connections and removing from site complete all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 14 | Taking up or down or out existing 80mm bore galvanised steel water tubing, alongwith connections and removing from site complete all as specified and directed. (Note:- Pipe line with fittings and accesories shall be measured overall as fixed along the centre line.) |
| 15 | Supply, lay, joint , fix and commission after test 80mm bore Centrifugally cast (spun) ductile iron with spigot & socket end, class K-7 conforming to IS: 8329/2000 complete with (push-on) rubber gasket jointing and centrifugally applied inside cement mortar lining with portland slag cement as per IS: 455:1989 and external metallic zinc coating as per annex A of IS 8329 with finishing layer of Bitumen coating as per Annex C of IS: 8329. The standard lengths of the pipes are 5.50 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000). Pursuant to clause 15.5.1 of IS8329, 10% of pipes in each size, may be supplied in shorter lengths, complete all as specified. Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 16 | Supply, lay, joint , fix and commission after test 100mm bore Centrifugally cast (spun) ductile iron with spigot & socket end, class K-7 conforming to IS: 8329/2000 complete with (push-on) rubber gasket jointing and centrifugally applied inside cement mortar lining with portland slag cement as per IS: 455:1989 and external metallic zinc coating as per annex A of IS 8329 with finishing layer of Bitumen coating as per Annex C of IS: 8329. The standard lengths of the pipes are 5.50 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000). Pursuant to clause 15.5.1 of IS8329, 10% of pipes in each size, may be supplied in shorter lengths, complete all as specified. Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 17 | Supply, lay, joint , fix and commission after test 150mm bore Centrifugally cast (spun) ductile iron with spigot & socket end, class K-7 conforming to IS: 8329/2000 complete with (push-on) rubber gasket jointing and centrifugally applied inside cement mortar lining with portland slag cement as per IS: 455:1989 and external metallic zinc coating as per annex A of IS 8329 with finishing layer of Bitumen coating as per Annex C of IS: 8329. The standard lengths of the pipes are 5.50 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000). Pursuant to clause 15.5.1 of IS8329, 10% of pipes in each size, may be supplied in shorter lengths, complete all as specified. Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 18 | Supply, lay, joint , fix and commission after test 200mm bore Centrifugally cast (spun) ductile iron with spigot & socket end, class K-7 conforming to IS: 8329/2000 complete with (push-on) rubber gasket jointing and centrifugally applied inside cement mortar lining with portland slag cement as per IS: 455:1989 and external metallic zinc coating as per annex A of IS 8329 with finishing layer of Bitumen coating as per Annex C of IS: 8329. The standard lengths of the pipes are 5.50 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000). Pursuant to clause 15.5.1 of IS8329, 10% of pipes in each size, may be supplied in shorter lengths, complete all as specified. Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 19 | Supply, lay, joint , fix and commission and test 15mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete laid in trenches and floor, fixed to walls and celling or complete all as specified and directed. |
| 20 | Supply, lay, joint , fix and commission and test 20mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete laid in trenches and floor, fixed to walls and celling or complete all as specified and directed. |
| 21 | Supply, lay, joint , fix and commission and test 25mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete laid in trenches and floor, fixed to walls and celling or complete all as specified and directed. |
| 22 | Supply, lay, joint , fix and commission and test 40mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete laid in trenches and floor, fixed to walls and celling or complete all as specified and directed. |
| 23 | Supply, lay, joint , fix and commission and test 50mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete laid in trenches and floor, fixed to walls and celling or complete all as specified and directed. |
| 24 | M&L for Ductile Iron fittings ISI marked for spigot and socketed pipe upto 300mm bore such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs, specials, complete all as specified and directed. |
| 25 | M&L for Ductile Iron fittings ISI marked for falnged pipes upto 300mm bore such as Bends. Tapers. Tee pieces (single & double branch) any type and angle/radius and straight connecting pieces but all ends flanged complete all as specified and directed. |
| 26 | Cutting 80 to 200mm bore cast iron (CI)/ Ductile Iron (DI)/ Mild Steel (MS)/Galvanised Iron (GI) water supply pipes for making conections complete all as specified and directed. (Note:- Each cut to be measured and paid for separately) |
| 27 | Detecting leakage of 80mm bore Cast Iron water supply pipe lines in any location, any depth and repairing by providing jointing material lead, lead wool, flanged, clamps, nuts, washers & bolts etc., complete all as specified and directed. Note : Length of pipe shall be measured and paid seperately under respective item of BOQ and complaint of leakage shall be done within 48 hrs otherwise a panel recover of Rs. 2000/- per leakage per day beyond the time shall be made from contrator's dues. |
| 28 | Detecting leakage of 100mm bore Cast Iron water supply pipe lines in any location, any depth and repairing by providing jointing material lead, lead wool, flanged, clamps, nuts, washers & bolts etc., complete all as specified and directed. Note : Length of pipe shall be measured and paid seperately under respective item of BOQ and complaint of leakage shall be done within 48 hrs otherwise a panel recover of Rs. 2000/- per leakage per day beyond the time shall be made from contrator's dues. |
| 29 | Detecting leakage of 150mm bore Cast Iron water supply pipe lines in any location, any depth and repairing by providing jointing material lead, lead wool, flanged, clamps, nuts, washers & bolts etc., complete all as specified and directed. Note : Length of pipe shall be measured and paid seperately under respective item of BOQ and complaint of leakage shall be done within 48 hrs otherwise a panel recover of Rs. 2000/- per leakage per day beyond the time shall be made from contrator's dues. |
| 30 | Detecting leakage of 20mm bore Galvanised Iron water supply pipe lines in any location, any depth and repairing by providing jointing material, \\"D\\" joints, union, clamps, nuts, washers & bolts and including any of all type GI fittings etc. complete all as specified and directed.Note : Length of pipe shall be measured and paid seperately under respective item of BOQ and complaint of leakage shall be done within 48 hrs otherwise a panel recover of Rs. 2000/- per leakage per day beyond the time shall be done. |
| 31 | Detecting leakage of 25mm bore Galvanised Iron water supply pipe lines in any location, any depth and repairing by providing jointing material, \\"D\\" joints, union, clamps, nuts, washers & bolts and including any of all type GI fittings etc. complete all as specified and directed.Note : Length of pipe shall be measured and paid seperately under respective item of BOQ and complaint of leakage shall be done within 48 hrs otherwise a panel recover of Rs. 2000/- per leakage per day beyond the time shall be done. |
| 32 | Detecting leakage of 40mm bore Galvanised Iron water supply pipe lines in any location, any depth and repairing by providing jointing material, \\"D\\" joints, union, clamps, nuts, washers & bolts and including any of all type GI fittings etc. complete all as specified and directed.Note : Length of pipe shall be measured and paid seperately under respective item of BOQ and complaint of leakage shall be done within 48 hrs otherwise a panel recover of Rs. 2000/- per leakage per day beyond the time shall be done. |
| 33 | Detecting leakage of 50mm bore Galvanised Iron water supply pipe lines in any location, any depth and repairing by providing jointing material, \\"D\\" joints, union, clamps, nuts, washers & bolts and including any of all type GI fittings etc. complete all as specified and directed.Note : Length of pipe shall be measured and paid seperately under respective item of BOQ and complaint of leakage shall be done within 48 hrs otherwise a panel recover of Rs. 2000/- per leakage per day beyond the time shall be done. |
| 34 | Detecting leakage of 80mm bore Galvanised Iron water supply pipe lines in any location, any depth and repairing by providing jointing material, \\"D\\" joints, union, clamps, nuts, washers & bolts and including any of all type GI fittings etc. complete all as specified and directed.Note : Length of pipe shall be measured and paid seperately under respective item of BOQ and complaint of leakage shall be done within 48 hrs otherwise a panel recover of Rs. 2000/- per leakage per day beyond the time shall be done. |
| 35 | Detecting leakage of 100mm bore Galvanised Iron water supply pipe lines in any location, any depth and repairing by providing jointing material, \\"D\\" joints, union, clamps, nuts, washers & bolts and including any of all type GI fittings etc. complete all as specified and directed.Note : Length of pipe shall be measured and paid seperately under respective item of BOQ and complaint of leakage shall be done within 48 hrs otherwise a panel recover of Rs. 2000/- per leakage per day beyond the time shall be done. |
| 36 | Attnding complaints of External Water Supply Distributuon System such as no water supply, faults, problems, malfunction of sluice valves , float valves, non-return valves, stop valves, gate valves, butterfly valves at various pump houses and installations and rectfying the defects and restoring water supply within 3 hours Note : 1. If any complaint shall not be attending within same day or till 12hrs than contractor shall be laible to recovery of Rs. 2000/- per complaint per day. 2. The contractor shall depute required Technical staff and supervisors for the works who shall remain present for discharging their duties at MES Service Centre from 9:00 A.M. to 5:00 P.M. on all days iexcluding Sundays and Closed Holidays. Only supervisor shall be present at service centre alongwith staff to attend the emergent nature of complaint and as specified and directed by Engineer-in-Charge. 3. Service centre will operate in full from 09:00 AM to 05:00 PM (General Shift) on all days including Sundays and National Holidays. Additional arrangements shall be made for registration and attending emergent complaints related to electricity, Sewerage & plumbing etc from 5:00 P.M to 9:00 AM on all days including Sundays & National Holidays & supervisor alongwith request No of tradesman to carryout emergent nature of complaints.4. The contractor shall also be responsible to use computerized complaints receiving and monitoring system and login to MES E-complaint (Web based application) before 09.30 hours daily. The contractor will have to arrange and maintain telephones, computers along with peripherals and broadband Internet connections to operate MES E-complaint. The contractor shall also pay all the bills/running cost of computer and its connection(s)available at the service centre which can be used by the contractor if he so desires however bill will have to be paid by the contractor. |
| 37 | S&F in repairs 15mm bore fancy type, chromium plated, Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 38 | S&F in repairs 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes including taking down / dismantling existing GM valves complete all as specified and directed. |
| 39 | S&F in repairs 25mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes including taking down / dismantling existing GM valves complete all as specified and directed. |
| 40 | S&F in repairs 40mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes including taking down / dismantling existing GM valves complete all as specified and directed. |
| 41 | S&F in repairs 50mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes including taking down / dismantling existing GM valves complete all as specified and directed. |
| 42 | S&F in repairs 50mm bore Cast Iron Body Double Air Release valves, with rubber ball, both ends flanged for iron pipes including taking down / dismantling existing Double Air Release valves complete all as specified and directed. |
| 43 | S&F in replacment 100mm bore Cast iron body sluice valve heavy duty class ‘PN-1.6’, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling and taking out old unserviceable sluice valve, complete all as specified and directed. Note:-Excavation and earth work shall be measured and paid for separately under appropriate items of this Schedule/BoQ. CI/DI fittings shall be measured and paid for separately |
| 44 | S&F in replacment 150mm bore Cast iron body sluice valve heavy duty class ‘PN-1.6’, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling and taking out old unserviceable sluice valve, complete all as specified and directed. Note:-Excavation and earth work shall be measured and paid for separately under appropriate items of this Schedule/BoQ. CI/DI fittings shall be measured and paid for separately |
| 45 | S&F in replacment 200mm bore Cast iron body sluice valve heavy duty class ‘PN-1.6’, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling and taking out old unserviceable sluice valve, complete all as specified and directed. Note:-Excavation and earth work shall be measured and paid for separately under appropriate items of this Schedule/BoQ. CI/DI fittings shall be measured and paid for separately |
| 46 | S&F in replacment 150mm bore Cast iron body Non Return Sluice Valve R/Flap FL ISI marked with confirming to BIS-5312, both flanged ends and drilled, 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling and taking out old unserviceable Non-returnvalve, complete all as specified and directed. Note:-Excavation and earth work shall be measured and paid for separately under appropriate items of this Schedule/BoQ. CI/DI fittings shall be measured and paid for separately |
| 47 | Repair to sluice valve of any size to rectify leakage by filling gland, replacig rusted nuts, bolts and washers, required lathe work sheets, spindle, and gland flange or any repair /replacement required for smooth and efficient functioning of sluice valve, complete all as specified and directed. Note:-Excavation and earth work shall be measured and paid for separately under appropriate items of this Schedule/BoQ. CI/DI fittings shall be measured and paid for separately |
| 48 | S&F in replacment 150mm bore Cast iron body Non Return Sluice Valve R/Flap FL ISI marked with confirming to BIS-5312, both flanged ends and drilled, 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling and taking out old unserviceable Non-return valve, complete all as specified and directed. Note:-Excavation and earth work shall be measured and paid for separately under appropriate items of this Schedule/BoQ. CI/DI fittings shall be measured and paid for separately |
| 49 | Cleaning Valve Pit of size 1200x1200x1200mm (internal dimensions) by taking out mud, soil, gabage, debris etc and repairing by doing brick work, concrete work, plaster work as and if required at site including cleaning , greasing and oiling sluce valves, gate valves and painting pit and cover complete all as specified and directed |
| 50 | Construction of Valve Pit of size 1200x1200x1200mm (internal dimensions) , excavation and earth work in any type of soil and strata,100mm thick lean concrete PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate for foundation, and 460mm thick brick masonry wall built in cement mortar (1:4) using sub class \\"B\\" old size well burnt bricks , 15mm thick internal and external plaster in cement mortar (1:4) upto15cm below ground level mixted with water proofing compound, 3.15mm thick MS sheet cover with angle iron frame of size 40x40x6mm to be fitted in and around 50x50x6mm mild steel angle iron frame with 50X6mm flat iron hold fasts embedded in PCC Coping (1:2:4) type B-1 of 150mm depth and width equal to thickness of wall including locking arrangement with necessary fixing materials like hinges, nuts and bolts etc (valve chamber cover shall be opened in two halves) and painting to MS cover with one coat of red oxide primer and two coats of synthetic enamel paint and two coats of cement base paint over a coat of primer etc all as specified and all as shown in Drawing No.1060/08 Sheet No. 1/3 to 3/3 dated 01.05.2008. |
| 51 | Construction of Valve Pit of size 900x900x900mm (internal dimensions) , excavation and earth work in any type of soil and strata,100mm thick lean concrete PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate for foundation, and 460mm thick brick masonry wall built in cement mortar (1:4) using sub class \\"B\\" old size well burnt bricks , 15mm thick internal and external plaster in cement mortar (1:4) upto15cm below ground level mixted with water proofing compound, 3.15mm thick MS sheet cover with angle iron frame of size 40x40x6mm to be fitted in and around 50x50x6mm mild steel angle iron frame with 50X6mm flat iron hold fasts embedded in PCC Coping (1:2:4) type B-1 of 150mm depth and width equal to thickness of wall including locking arrangement with necessary fixing materials like hinges, nuts and bolts etc (valve chamber cover shall be opened in two halves) and painting to MS cover with one coat of red oxide primer and two coats of synthetic enamel paint and two coats of cement base paint over a coat of primer etc all as specified and all as shown in Drawing No.1060/08 Sheet No. 1/3 to 3/3 dated 01.05.2008. |
| 52 | M&L for lead wool joints for 80 to 2000mm bore CI/DI pipes complete all as specified and directed. |
| 53 | Collecting sample of raw water in sterlized sample bottles and testing for potability of water from NABL accredited laboratories and submittion of test report in duplicate. Test results and Parameters are to be checked for pH Value, TDS, Alkalinity, Acidity, Turbidity, Total Harness as CaCO3, Calcium, Magnesium, Chlorides, Iron, Florides, Nitrates, Sodium, Potassium, Arsenic, Cyanide etc or any material/element/component deemed necessary or as directed by the Engineer-in-Charge. Water Potability Certificate shall be issued by the NABL Lab in the Test Report, complete all as specified and directed. |
| 54 | M&L for preparation of steel or iron surfaces of water supply pipes of any description exceeding 10cm width or girthwhen unconnected with other painting or when painted in different tint and applying two coats of anti corrisive synthetic enamel paint in diffferent tint/colour over a coat of red oxide zinc chrome primer for water supply mains, raising mains, over flow pipes, wash out pipe complete all as specified and directed. (Note:- Each cut to be measured and paid for separately) Please Enable Macros to View BoQ information |