| 1 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground |
| 2 | Dismantling fencing wire mesh,any type |
| 3 | M&L Structural steel, rolled section such as joist, beam, channel, angle, tee, of Fe 410-W (Gde-E-250) quality- A in available lengths complete all as specified and directed by engr in charge |
| 4 | Supply only Chain link MS galvanisd fencing, any size or type for fencing. |
| 5 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire |
| 6 | S&F flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 ® |
| 7 | S&F Mild steel screw bolts 5 to 10 mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long |
| 8 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 9 | Supply and fixing in repairs Barbed rozor tap concertina coil SG hot galvanised spring tensile wire manufactured by make as approved by GE of UTS 220 to 245 Kg/mm2 and dia of coil when stretched 600 mm having minimum number of circles 10/RM, minimum number of clips 25/RM & minimum weight of coil 1.625Kg/RM hot dip galvanised including taking out existing damaged concertina coil complete all as specified and directed by Engr-in-Charge. |
| 10 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm |
| 11 | M&L PCC type C-2, 1:3:6 (40 mm graded aggregate) in foundation filling and mass concrete arrangements all as specified and directed by engr in charge |
| 12 | M&L Mild steel round bars 10mm dia and over, cut to length, bent to shape for securing wiremesh fencing complete all as specified and directed by engr in charge. |
| 13 | Cleaning of blocked WC seat any type (pedestal/squatt Orissa pattern) /pattern/ Kitchen trap/bathroom trap up to 1st manhole and making the drain pipe of any size full functional by flushing with water to entire satisfaction of Engineer-in-Charge including cleaning of 1st manhole and removing the waste material/sludge etc to a distance n.exc 300m and burying the same in pits and top surface covered with earth complete all as specified and directed by Engineer-in-Charge. |
| 14 | Cleaning /clearing & Maintenance of sewage lines, manholes including CI stacks, incl under ground sewage lines any depth by removing any type of blockage from sewage drain upto and including 300mm dia by rodding or any other means from manholes to manholes or from trap and flushing with water after cleaning including manholes. Sludge/sludge water to be disposed off through sludge in form of semi solid/loose state will be disposed off by burring with in any distance outside the periphery of defence land including taking off manhole covers and refixing the same after cleaning. The operation shall be executed/carried out as under. NOTE:- 1. The contractor shall keep the sewage line functionally throughout the contract period. Any kind of sewage cleaning device such as sewage cleaning Mechanical Pump / Vehicle including in the rate quoted by the contractor. |
| 15 | Earth work in excavation of any type of soil by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-incharge |
| 16 | Add to item No. 03 Above for each additional 1.5 m or part thereof in depth beyond the first 1.5 m as directed by Engineer-in charge |
| 17 | M&L for 15 mm thick cement plaster in CM 1:4 on bricks or concrete surfaces finishing the surfaces even and smooth without using extra cement as directed all as specified Note rate for form work if reqd to be incl in the quaoted by the contractor. |
| 18 | M&L Fly Ash Brick work straight or curved on plan built in cement mortar 1:6 complete and all as specified and directed by Engineer-in-Charge. |
| 19 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation etc and n exc 1.5m in depth and getting out complete in soft.loose soil. |
| 20 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar |
| 21 | M&L for reinforced concrete pipes class NP2 150mm dia, laid and jointed complete with collars including of demolition of old pipe . |
| 22 | M&L for cement concrete 1:3:6 type C-2 for bed to drain pipes 150 mm dia including packing under, and haunching against the sides of pipes afternthey are laid and tested |
| 23 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil. |
| 24 | Removing excavated material nexc 50m and depositing where directed at a level n exc 1.5m above the starting point. |
| 25 | Taking down existing PVC pipes 110/75 mm inside the shaft area of building repairing the wall and plaster inside shaft upto 7 mtr height including jambs and cill of bathroom and toilets ventelator and refixing the pipes after repair of wall and applying water proofing coating to avoid further seepage to bathroom /toilet walls |
| 26 | M&L preperation of old/newely plastered surface and Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) in camouflage pattern (four) or more shades as directed by Engr-in-Charge incl necessary scaffolding and other safety arrangement to work at any height at site if required. |
| 27 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 28 | Laying only Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size of 60mm thickness, M-35 grade and directed. |
| 29 | Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 30 | Demolition Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified. |
| 31 | M&L for 100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded agg ) as in flooring complete all as specified and directed. |
| 32 | M&L for Chequered cement concrete tiles with grey cement and pigment 30cmx30cmx25mm thick, set, jointed and pointed in neat cement slurry in floors laid over screed bed 15 mm thick in cement mortar (1:4) all as directed and specified. |
| 33 | Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approvedcolour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete. |
| 34 | M&L Sand filling under floors or in foundations/ paver blocks including watering and consolidation |
| 35 | Dismantling structural steel work including doors, gates but excluding framed truss etc. |
| 36 | S&F Framed work of Fe-410- W(Gde- E-250) quality B as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 37 | Dismantling of asbestos cement corrugated or semi corrugated sheet in roof covering |
| 38 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 39 | Material and labour for preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 40 | S&F Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles exc 5 kg |
| 41 | M&L Cement concrete type D- 2,1:4:8 (40mm graded aggregate) as subbase for tiling |
| 42 | M&L outdoor (Endura) tiles30cm x 30cm x 12-15 mm thick, set, jointed and pointed in neat cement slurry in floors including 15 mm thick bedding layer in CM 1:4 and demolition of existing old u/s tiles.Make Orientbell/Johnson/Kajaria |
| 43 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for. |
| 44 | Providing pre cast cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) in landing cover slab for manholes/ drain including provision of handle for lifting and sides to be covered with angle iron finished even smooth complete all as specified and directed. |
| 45 | TMT Mild steel bars upto 10mm dia, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 46 | PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in surface channel and drains and similar work complete all as specified and directed. |
| 47 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, metred stopped ends complete all as specified and directed. |
| 48 | Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in bed blocks, coping, cills,steps, kneelers, bed plates, apex stones kerbs and similar work including necessary form work complete all as specified and directed |
| 49 | Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth with out using extra cement complete all as specified and directed. |
| 50 | Providing pre cast cement concrete in landing cover slab for manholes 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) finished even smooth complete all as specified and directed. |
| 51 | TMT Mild steel bars 8 to 10 mm dia , cut to length , bent to shape required including cranking, bending spirally for hopping to columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 52 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr in charge. |
| 53 | Walling of random rubble, uncoursed well bonded, bedded and solidly hearted, built in cement mortor 1:6 Except stone |
| 54 | Walling of random rubble, uncoursed well bonded, bedded and solidly hearted, built in cement mortor 1:6. |
| 55 | M & L preparation of old steel surfaces exc 10cm width or grith and applying one coat of synathetic enamel paint complete all as specified. |
| 56 | Cutting holes into or through brick walls built in cementmortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required not exc 1.5 Sqcm |
| 57 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. of size Exc 500 Ltr and upto 1000 Ltr |
| 58 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. of size Exc 250 Ltr and upto 500 Ltr |
| 59 | Material & labour for coloured glazed ceramic tiles in vertical surface 450 x 300 x 7 mm thick on gate pillars set and jointed in neat cement slurry and pointed in white or colour cement to match with the shade of tiles including 10 mm thick screed bed or bedding layers in cement mortar 1:3 for laying tiles on vertical surfaces, including Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubish of the premises complete all as specified and as directed. |
| 60 | Drilling Holes drilled up to 12mm dia (and countersunk, if required exc 3mm but not exc 12 mm thick complete all as specified and directed Please Enable Macros to View BoQ information |