| 1 | S.I.T.C of Steel Pole, 4mtr. height are made of Galvanised steel tubes having bottom part of the pole (1000mmx114mmx4mm) and upper part is (3000mm x 75mm x 3mm) made out of mild steel galvanised tubes. The bottom and middle part of the poles are fitted with cast alum. embellishments and are fitted and sealed by gurb screws as shown in the drawing. The Poles has a service window at the bottom containing 25amp connector terminal and MCB of the desired rating. The Poles are primer coated and painted with polyurethane paint of the desired colour etc as required. (As per Annexure- D Page No. 48) |
| 2 | S.I.T.C of Steel Pole, 3mtr. height are made of Galvanised steel tubes having bottom part of the pole (1000mmx114mmx4mm) and upper part is (2000mm x 75mm x 3mm) made out of mild steel galvanised tubes. The bottom and middle part of the poles are fitted with cast alum. embellishments and are fitted and sealed by gurb screws as shown in the drawing. The Poles has a service window at the bottom containing 25amp connector terminal and MCB of the desired rating. The Poles are primer coated and painted with polyurethane paint of the desired colour etc as required. (As per Annexure- E Page No. 49) |
| 3 | S.I.T.C of 40Watt LED Post Top decorative fitting with Die Cast Aluminium housing, 3 nos. die cast aluminium arms, die cast aluminium base and top. A PMMA diffuser is provided for glare glare free lighting duly painted and primer coated with PU paint. Total system Lumens of the fixtures are minimum 4000 lumens having Luminous efficacy ≥ 100 Lum/Watt, CCT 2700-3000K, CRI ≥ 80 and having inbuilt Surge protection ≥ 4KV. The Lamp compartment of the fixtures are IP-66 etc as required. (As per Annexure- F Page No. 50) |
| 4 | S.I.T.C of 25Watt LED Post Top decorative fitting with Die Cast Aluminium housing, 3 nos. die cast aluminium arms, die cast aluminium base and top. A PMMA diffuser is provided for glare glare free lighting duly painted and primer coated with PU paint. Total system Lumens of the fixtures are minimum 2500 lumens having and Luminous efficacy ≥ 100 Lum/Watt, CCT 4000K, CRI ≥ 80 and having inbuilt Surge protection ≥ 4KV. The Lamp compartment of the fixtures are IP-66 etc as required. (As per Annexure- G Page No. 51) |
| 5 | Fabrication, supplying and installation of outdoor type, sloping roof cubical feeder pillar of surface area not less than 1 sq meter with minimum depth of 45 cm made out of CRCA M.S. Sheet of 2 mm thick (14 SWG) duly compartmentalized having 4 strip bus bar of 400 Ampers capacity double door with double locking arrangement (one sliding lock in front and one godown lock each at front and rear for protection) dust proof vermin process, duly fixed on M.S. angle iron frame work of size 50 mm X 50 mm X 6 mm (NS) 90 cm long legs, out of which 45 cm duly painted with one coat of red oxide & two coats of superior quality enamel paint in approved shade and colour etc. complete with testing, earth studs, earth strips etc. as required. |
| 6 | Suppling, Installation Testing and commissioning of following accessories |
| 7 | 250 A,36KA,FPMCCB |
| 8 | Digital type volt meter (0-500 volts) with selector switch |
| 9 | Digital type Ammeter (0-250 Amp) with selector switch |
| 10 | Indicating light LED type with 2 A Ampers SP MCB (3 Nos) |
| 11 | 100 Amps, 3 pole power contactor |
| 12 | Digital Time Switch |
| 13 | 400 / 5 Amp. CT (3 Nos.) |
| 14 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 15 | 3 x 1.5 Sq.mm |
| 16 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 17 | 4 X 16 sq. mm (28mm) |
| 18 | 4 X 25 sq. mm (28mm) |
| 19 | 3½ X 150 sq. mm (50mm) |
| 20 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 21 | Upto 35 sq. mm |
| 22 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the hanging pole to pole on pin insulator etc. as required. |
| 23 | Upto 35 sq. mm |
| 24 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 25 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 26 | Supplying and testing one number PVC insulated and PVC sheathed / XLPE aluminium power cable of 1.1 kV grade of following size and colour of XLPE cable should Brown colour with 'PWD' embossed / marked on it at every meter etc as required |
| 27 | 4 x 16 sq.mm |
| 28 | 4 x 25 sq.mm |
| 29 | 3.5 x 150 sq.mm |
| 30 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 31 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 32 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required |
| 33 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 34 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 35 | Wiring for light/ power plug with 2X4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 36 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
| 37 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required |
| 38 | 8 Module (125mmX125mm) |
| 39 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 40 | 15/16 A switch |
| 41 | 6 pin 15/16 A socket outlet |
| 42 | Fabrication, Supplying, & fixing of wiremesh protection frame work fabricating with 40 x 40 x 6 mm thick M.S. angle iron & T iron of 40 x 40 x 6mm thick i/c providing & fixing wire mexh of section 75 mm x 25mm of 6 SWG shall have the legs of angle iron of size 40 x 40 x 6mm of length 15cm and is to be grouted in cement concrete (1:2:4) foundation. the frame box module made out of angle or T iron should not be more than 1 sq.mtr. This frame work is to be fixed around the various electrical & mechanical equipment & appliances which should have the door on one side with interlocking arrangement & all frame work is to be painted with two coats of red oxide, primer and two coats of synthetic enamel paint of approved colour & quality etc, as reqd. |
| 43 | Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 44 | Copper Patch Cords of length 1m (3ft) |
| 45 | Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy in dentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required |
| 46 | 4 Run of cable |
| 47 | Supplying and drawing following core Multi mode Fiber Optic Cable having corrugated steel armoring, leser optimize 50/125 μm with HDPE jacket, LSZH (Low smoke Zero Halogen), Tight-buffered or loose tube, maximum attenuation: < 3.5 dB/km at 850 nm, < 1.5 dB/km at 1300 nm, bandwidth > 2000 MHz-km at 850 nm, > 500 MHz-km at 1300 nm compliance and certifications: ISO/IEC 11801 Ed. 2.2, ANSI/TIA-568- C.3, ITU-T G.651.1 RoHS compliant. Multi Mode Fiber shall be Central-loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793- 1/60794-1-2, ITU-T-REC G.652D and Telecordia GR- 20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature should be – 5 0C to +50 0C, Maximum Attenuation ± 3.5 dB/km at Operational Wavelength 850 nm and ± 1.5 dB / km at Operational Wavelength 1300 nm . type of fiber should be 50/125 / G.652D & Refractive Index should be 1.483/1.478, The value for Mode-filed, Cladding Diameter 50 ± 2.5 μm and 125 ± 1μm correspondingly i/c splicing & marking etc complete as required. |
| 48 | 6 Core Multi Mode Optical Fiber Cable |
| 49 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 50 | 9U Rack |
| 51 | Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 128Gbps and packet forwarding rate of 95Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 4 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol |
| 52 | VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying |
| 53 | Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: FCC, CE marked, UL/EN, RoHS and relevant MTCTE(TEC)/BIS compliance / certification as applicable, etc. complete as required. |
| 54 | 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min. |
| 55 | Supplying Installation Testing and Commissioning of 5/6MP IP IR Dome Camera having following specifications and features etc :-1) Type of Camera: Dome Camera2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition3) Signal System: PAL/NTSC4) Minimum Illumination: 0.008Lux@ F1.4, AGC ON, 0 lux with IR or better5) Imaging: 1/3s to 1/30000s Shutter Support, Auto Gain Control, White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both.7) Signal to Noise Ratio: > 50 dB8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR 30 Mtrs for colour view in night.9) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.72310) Wide Dynamic Range: WDR (120dB or more)11) Digital Noise Reduction: DNR (2D/3D) On/Off12) Streaming: Triple streaming, configurable13) Video Streaming & Frame Rates: Triple streaming, configurable Main stream: 5/6MP @25/30 fps, Sub streams: D1@25/30 fps or better 14) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser15) Profile Management: User configuration import, export16) Security: User Authentication, Water Marking17) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.18) Recording Management: Format SD, overwrite, storage management, video to NAS device 19) Edge Analytics : Tripwire, Intrusion, Motion Detection20) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection21) Alarm Support: It should have 1/1 Alarm In/ Out Port22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio compression23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast.24) System Capability: ONVIF25) VMS: Camera shall support open source VMS.26) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, , account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade.27) Ethernet: 1 RJ 45 10/100 Ethernet port28) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source.29) Power Requirement: 12VDC/24VDC/PoE (802.3af)/ePoE30) Enclosure: IP67 weather proof, IK1031) Operating Condition: Ambient Temperature:- (-) 05°C to 50°C, humidity 95% (max) (non-condensing)32) IR life: 40000 hours or higher33) Video Bit rate: 32 KBPS - 8 MBPS or better34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 56 | 5MP/6MP IP IR 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) Dome Camera. |
| 57 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below :1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or more and must be ONVIF with minimum support of 384 Mbps incoming Bandwidth.2) NVR should support video compressions : H.265 or better, H.264, MJPEG.3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u, PCM, G726 audio compressions.4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 8 SATA Slots with 16TB capacity/ Slot and RAID support of RAID 0/1/5/6/10. (4 SATA (32 Channel) & 8 SATA Slot for 64 Channel)6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)8) Video Output Ports: 2x HDMI and 2 VGA9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.10) Email & SMS Altert options: Option for SMS/Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic Operating Condition : -5°C to 50°C, humidity 90%(max) (non-condensing) 12) Face Recognition Database Capacity: It shouldsupport total Blacklist and Whitelist capacity ofMinimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to add Name, gender, birthday, address, credential type, credential No., countries & regions and state to each face image. 13) Face & Human Attributes Search: SearchPictures/ Video by Gender, age group, glasses,expressions, face mask, beard, Top color, top type,hat, bag, age, gender and umbrella.14) ANPR Capability: It should support ANPRCamera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes. |
| 58 | 15) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception16) Alarm Notification should be linked with Recording,snapshots, Camera external alarm output, buzzer,logs, presets and email.17) General AI Based Search: Search Pictures bychannel, time, event type, target classification (FallDetection, People Approach Detection, People No.Exception Detection, People Staying Detection,Violence Detection.18) Smart playback function: Should support smartsearch for the selected area in the video and smartplayback to improve the playback efficiency19) VCA (Video Content Analytic): Should supportmultiple video contented analytics based on cameraanalytics20) Analytics by NVR: Perimeter protection and facerecognation21) The VMS application shall support all the features& functionalities of the offered cameras.22) VMS should consist Licenses for all channels torecord Cameras with General, motion detection,intelligent, alarm and POS recording modes. VMSshould be provided with Camera Licenses , with nodependency of VMS licenses by binding with the MACaddress of the cameras to achieve the functionality.23) The NVR OEM shall be responsible for providing amobile application compatible with both Android andiOS devices, enabling remote monitoring and playbackof cameras/NVR footage.24) The OEM must provide its own DDNS serverhosted in India, eliminating the need for a public IPaddress for remote monitoring over the Internet.25) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode26) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF27) When alarm recording is enabled and an eventoccurs, you can click the alarm icon on monitoringpage to view the alert details. The snapshot function is supported on monitoring and playback page |
| 59 | 28) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm 29) It should have Web and GUI interface.30) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection31) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing.32) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need.33) Standards: CE, FCC, RoHS, BIS Certified34) Power Supply : Should support AC100-240V, 50/60Hz Power supply. |
| 60 | 32 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/32(36), 2nd screen: 1/4/8/9/16 |
| 61 | Supplying, Installation, Testing and Commissioning following capacity Surveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications |
| 62 | 8TB (Terabytes |
| 63 | Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840 x 2160 resolution or better, USB playback, Bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required. |
| 64 | 32 inch or larger Please Enable Macros to View BoQ information |