|
| 1 | side kett &interlock |
| 2 | OD64190/2026-2027:(OD from 2.8.1)Earth work in excavation by mechanical means (Hydraulic excavator) /manualmeans in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out theexcavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 3 | OD61268/2026-2027:DRY RUBBLE MASONRY _ Dry rubble without concretelevelling course masonrywith good quality blasted rubble including packing to compactness to lines and levels cost and conveyanceof all materials labour charges etc. complete as per direction of Departmental officers at site |
| 4 | 4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) <br> (A) By Mix in Place Method <br> Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. <br> (i) For Grading I Material |
| 5 | OD61234/2026-2027:OD from MORD 6.7.1)( Interlocking concrete block pavementProviding and laying of interlocking concrete block pavements having thickness 80mm as perdrawing and technical specification clause 1504 |
| 6 | OD61241/2026-2027:Providing Plain cement concrete for road work CC 1:2:4 (1 cement: 2 fine aggregate: 4course aggregate) laid to required slope and camber in panels (@ 3 m c/c) as requiredincluding compaction, finishing and tamping etc .complete. Max. size of courseaggregate not exceeding 25mm , mixed in concrete mixer etc complete as perspecification(i) Nominal mix (1:2:4) |
| 7 | 11.4.4:Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203<br> IV. R.C.C grade M 20 |
| 8 | OD68539/2026-2027:Providing and fixing hand rail of approved size by welding etc. to steel ladderrailing, balcony railing, staircase railing and similar works, including applyingpriming coat of approves steel primer. G.I. pipes |
| 9 | OD68546/2026-2027:Providing and fixing granite of any colour and shade for name board of required size laid over base of cement mortar 1:4 includind all charges complete at levels including lettering and fixing. |
| 10 | BUSSTOP |
| 11 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 12 | OD67579/2026-2027:DRY RUBBLE MASONRY _ Dry rubble without concretelevelling course masonrywith good quality blasted rubble including packing to compactness to lines and levels cost and conveyanceof all materials labour charges etc. complete as per direction of Departmental officers at site |
| 13 | 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 14 | 10.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 15 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 16 | 50.12.2.1:Providing & fixing Poly carbonate corrugated sheet 0.8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling / self tapping screw of size (5.5x55 mm) with EPDM seal complete upto any pitch in horizontal/ vertical/ curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size shapes where ever required. |
| 17 | 11.19.1:Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand):Light shade pigment using white cement |
| 18 | OD67656/2026-2027:Providing and fixing 63 mm Pvc pipes 10 kgf /cm2 including jointing of pipes with one stepsolvent cement including trenching and refilling testing the joints complete as perspecifications |
| 19 | OD67660/2026-2027:Providing and fixing 200 mm wide, square cut PVC 4kgf/cm2 rain water gutter pipe with ironbrackets with 25x5 mm size flat, screws and washers etc., including making necessaryconnections with rain water pipes etc. complete. |
| 20 | 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 21 | OD67692/2026-2027:Supplying and fixing at site Aluminium composite pannel (ACP) of approved makefixed in aluminium frames and necessary clips and hooks etc complete. with A C P sheet 3 mmthick,Aluminium frame strips fixed in steel frames ,Aluminium frames 25 X25 ,Rubber beeding,and necessary clips and hooks labour etc complete as per the direction of deptl. officers at site |
| 22 | OD68438/2026-2027:Supplying and fixing in position stainless steel letters in Malayalam of size 25 cmheight and 2 cm depth, approved by Departmental Officers including all cost, fabrication charges etc Please Enable Macros to View BoQ information |