| 1 | ELECTRIFICATION |
| 2 | 1.10.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A |
| 3 | 1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 4 | 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 5 | OD100388/2025-2026 Wiring combined plug point together with the light point/ fan point/exhaust fan point/ call bell point including 6 A 5 pin modular socketcontrolled by 6A one way modular switch in the existing switch board and giving connection to the phase, neutral and earth terminal with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable (Green wire for earthing) etc as required. |
| 6 | 90.3.21.3 Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. 1200 mm 1X20W LED Lamp with box type fixture |
| 7 | 90.3.20.3 Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. 1200 mm 1X20W LED Lamp with box type fixture |
| 8 | 1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 9 | OD100385/2025-2026 Supply and providing the following types and power rated lamps in the existing fittings as required. B22 LED bulb 9W |
| 10 | OD100376/2025-26 Supply, conveyance, installation , testing and commissioning of 12 W LED Bulkhead Light fittings Lumen output - 600, Housing-High pressure die cast aluminium directly on wall including giving connectins with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required. (LUKER STYX ECO BULKHEAD LIH+GHT 12 W LBKOVSL 12/ equivalent) |
| 11 | 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 12 | 90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. |
| 13 | 90.4.5.4 Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply |
| 14 | 90.4.8 Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. |
| 15 | Od 135079/2025-26 Supply, conveyance, installation , testing and commissioning of size 250 mm sweep light duty Exhaust fan in plastic body 1300rpmwith self openinglowers working on 230 V single phase A/C in the existing opening, fixing necessary anchor bolts and nuts etc. as required including giving connectins with the supplied wire along with the Exhaust fan |
| 16 | 90.15.4.1 Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 17 | 90.3.18.2 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps |
| 18 | 1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm |
| 19 | 1.17.6 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm |
| 20 | 1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 21 | 1.17.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm |
| 22 | 1.17.21 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 23 | 1.17.24 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm |
| 24 | 1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) |
| 25 | 1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm) |
| 26 | 1.27.4 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 27 | 1.27.5 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm) |
| 28 | 1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 29 | 1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 30 | 1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 31 | 1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 32 | 90.10.3.15 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 32A DP switch with indicator |
| 33 | 1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 34 | 2.3.4 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door |
| 35 | 2.4.2 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/Isolator) 6 Way (4+18), Double door |
| 36 | 2.4.1 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/Isolator) 4 Way (4+12) Double door |
| 37 | 2.5.1 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 WAY(4+12), DOUBLE DOOR |
| 38 | 2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 39 | 2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 40 | 2.14.1 Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps |
| 41 | 2.15.1 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps |
| 42 | 2.10.1 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 43 | 2.10.4 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole |
| 44 | 90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG) |
| 45 | 90.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 46 | OD100380/2025-26 Supply and providing the following sizes of bolt and nut with washers on the existing MS box/earth bus etc. as required including drilling necessary holes as required. 12x3 mm brass nut and bolt etc. as required |
| 47 | 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 48 | OD100375/2025-26 Supply and providing earth lead from the test joint to the arth electrode using the following sizes of conductors /strips including cutting, drilling neecessary holes (in case of strip) and fixing firmly with plate test joint etc as required. 25x3xmm GI strip |
| 49 | OD100382/2025-2026 Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2x25 x 3 mm GI strip |
| 50 | OD100381/2025-2026 Supply and installation of switch gear units in sheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement of the following ratings on existing angle iron frame work or directly to wall using necessary bolts &.nuts, fixing the unit to wall,making good damages, colour washing etc. including giving necessary connections as required. 100 Amp TP&N with ISI marked HRC fuse |
| 51 | OD150211/2025-2026 Supply and installation of switch gear units in sheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement of the following ratings on existing angle iron frame work or directly to wall using necessary bolts &.nuts, fixing the unit to wall,making good damages, colour washing etc. including giving necessary connections as required. 32 Amp TP&N with ISI marked HRC fuse |
| 52 | OD100378/2025-2026 Supply and installation of 1 phase meter board with provision for fixing KSEB energy meter, cut out fuse unit etc. (syntex make GSMB3525/ Equivalent) |
| 53 | OD150214/2025-2026 Supply and installation of 3 phase meter board with provision for fixing KSEB energy meter, cut out fuse unit etc. (syntex make GSMB6535/ Equivalent) |
| 54 | OD100384/2025-26 Supply nd fixing 32 mm dia 6 Kgf/cm2 PVC pipe including fixing the pipe with clamp/clips at 60 cm spacing. Etc as required (for service pipe) |
| 55 | OD100377/2025-2026 Supply and providing suitable Iron Hook grouted on wall for binding the service wire |
| 56 | 2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 57 | OD257969/2025-26 Supply and fixing 32 A , HRC fuse link with connections, in existing meter board. |
| 58 | OD257970/2025-26 Supplying and fixing 32 A, 2 way neutral links mounted on BMC/SMC base with connections, in existing meter board. Please Enable Macros to View BoQ information |