| 1 | Electrical work |
| 2 | OD505485/2025-2026:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanisedGI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of200x200x12 mm suitable for windspeed as per IS 875 Part III fixed head frame including roundarm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangementincluding connector foundation bolt 4 nos existing RCC foundation and junction box etc,complete 7 Meters |
| 3 | 90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 4 | 90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 5 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 6 | 90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) |
| 7 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 8 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 9 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 10 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 11 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 12 | 90.12.39.2:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm |
| 13 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 14 | 90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm |
| 15 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 16 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 17 | OD500173/2025-2026:Supply and installation of 230 V AC 50 Hz 25A 2pole power contactor in the existing enclosure and giving connections as required (L&T MNX 25-2P 2 Pole Power Contactor 25 A CS90240 or equivalent) |
| 18 | OD500172/2025-2026:Supply and installation of Digital Tme Switch suitable for 240V AC DIN based in the existing enclosure and giving connections as required |
| 19 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 20 | 5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 21 | OD500170/2025-2026:Supply and installation of dust and vermin proof single phase energy meter box for fixing smartenergy meter and accessories as required on wall, making good the damages colorwashing etc as required (Model GSMB 4537 450x375x200 mm Sintex make or equivalent ) to accommodate 32 fuse, Neutral link etc |
| 22 | OD500165/2025-2026:Charges for procurement, preparation and submission of application for availing single/three phase KSEB service connection with necessary Sketch, Test and completion report, application fee etc. including necessary liaison work as required. |
| 23 | OD500166/2025-2026:Supply and provide 32 A 2 way Neutral link in the existing meter board with suitable nu bolt |
| 24 | OD500164/2025-2026:Supply and providing 32A 240v HRC type Bakelite/ Porcelain fuse unit with suitable HRC fuse link and fixing with suitable bolt and etc. as required at site |
| 25 | OD500169/2025-2026:Providing and fixing 2x 25X3 GI strip test joint |
| 26 | OD500167/2025-2026:Supply and provide bass nut bot 25X6mm as required for required or fixing test joint |
| 27 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 28 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 29 | OD500168/2025-2026:Steel reinforcement for RCC work including straightening, cutting, bending, tying, placing in position and binding all coponents upto plinth level |
| 30 | OD500163/2025-2026:Supply and providing suitable Iron Hook grouted on wall / surface for binding the service wire |
| 31 | 90.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class) |
| 32 | OD505414/2025-2026:Cutting the existing Concrete floor/road using machinery/manual including clearing the waste material from site etc. as requited for pole foundation |
| 33 | 90.3.17.2:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.40 mm dia GI pipe |
| 34 | OD500171/2025-2026:Fabrication supply conveyance and installation of suitable size granite name board indicating the details of work as per the direction of department officer on existing base as Please Enable Macros to View BoQ information |