| 1 | S&F in-repair of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 6 Sqmm section, complete all as specified and as directed by engineer-in-charge. |
| 2 | All as per Item No. 01 here-in-above, but for cross-sectional area 10 Sqmm, complete all as specified and as directed by Engineer-in-charge. |
| 3 | All as per Item No. 01 here-in-above, but for cross-sectional area 16 Sqmm, complete all as specified and as directed by Engineer-in-charge. |
| 4 | Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 400 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items. |
| 5 | All as per Item No. 04 here-in-above, but for cross-sectional area 120 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. |
| 6 | All as per Item No. 04 here-in-above, but for cross-sectional area 95 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. |
| 7 | All as per Item No. 04 here-in-above, but for cross-sectional area 70 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. |
| 8 | All as per Item No. 04 here-in-above, but for cross-sectional area 50 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. |
| 9 | All as per Item No. 04 here-in-above, but for cross-sectional area 16 Sqmm 4 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. |
| 10 | All as per Item No. 04 here-in-above, but for cross-sectional area 16 Sqmm 2 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. |
| 11 | All as per Item No. 04 here-in-above, but for cross-sectional area 10 Sqmm 2 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. |
| 12 | M&L for Multistranded Copper Conductor flexible cable of 3 Core 1.5 Sq mm size drawn through steel tubular poles for interconnection of cable looping box to street light Fitting, Post Top Lantern & etc., complete all as specified and as directed by Engineer-in-charge. |
| 13 | S&F in-repair of aluminium lug suitable for making connection of aluminium armoured xlpe cable of size upto 25 Sqmm, complete all as specified and as directed by Engineer-in-charge. |
| 14 | All as per Item No. 13 here-in-above, but for cable size 35-95 Sqmm, complete all as specified and as directed by Engineer-in-charge. |
| 15 | All as per Item No. 13 here-in-above, but for cable size 120-240 Sqmm, complete all as specified and as directed by Engineer-in-charge. |
| 16 | S&F in-repair of Cable straight through joint kit for 1.1 KV (Earthed) graded cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 120 sqmm to 300 sqmm, complete all as specified and as directed. Make - Denson/3-M/ Raychem/ Seimens |
| 17 | M&L for boring holes horizontally under road without damaging the road surface with the help of GI tubing not exc. 80mm bore dia for passing of UG cable, complete all as specified and directed by Engineer-in-charge. NOTE: GI Pipe will be measured and paid separately. |
| 18 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge. |
| 19 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge. |
| 20 | Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge. |
| 21 | M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for. |
| 22 | Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge. |
| 23 | S&F of Galvanised Iron Pipe 50mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed by Engineer-in-charge. |
| 24 | All as per Item No. 23 here-in-above, but for 80mm bore (dia) pipe, complete all as specified and as directed by Engineer-in-charge. |
| 25 | Supply & Erecting in true vertical position of Steel Tubular Swaged Pole Type 410-SP-31 (9.00 Metre long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws with and including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying two Coats of Aluminium Painting over a coat of Red oxide Primer including necessary earthwork in excavation in any type of soil, removal of surplus soil to a distance of not exceeding 50.0m, Cement Concrete 1:3:6, type C-2 (40mm graded aggregate) as in Foundation of Poles filled upto ground level and Cement Concrete 1:2:4, Type B-1(20mm graded aggregate) as in Coping/Padestal of Poles and finishing the Concrete surfaces Fair and Even including necessary Formwork as required at Site(s) and dismantling the existing old damaged LT pole of any type, complete all as specified and as directed by Engineer-in-charge. NOTE: Earthwork, Cement Concrete, etc. will not be measured and paid separately. |
| 26 | S&F in-repair of Pole Box/Junction Box of size 155 X 210 X 92mm (LxBxH) made out of Polycarbonate material totally enclosed, dust and vermin proof, door pasted with rubber gasket, water tight IP 66/67 protection single leaf shutter in front having proper locking arrangements, including provision of suitable connector for single phase connections loop in and out 10 to 16 Sqmm 4.0 Core aluminium armoured cable branch out 1.5 Sqmm single core PVC insulated copper cable and MCB SP 06 amps- 01 No and mounted on security light pole with suitable clamps (GI Flat iron of 25x3mm), nuts, bolts, complete all as specified and directed by Engineer-in-charge. |
| 27 | M&L for preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles (above the Planting Depth and PCC Copings of 9.0 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one Coat of synthetic enamel paint in alternate Yellow & Black Strips (5 Nos. Strip of 300 mm wide each) and remaining portion of Pole and Cross Arms, Cable Protection Pipe, Brackets, etc. treated with One Coat of Aluminium Paint, including writing of pole numbers with black synthetic enamel paint, complete all as specified and as directed by engineer-in-charge. |
| 28 | S&F in-repair of MCCB 4 Pole, 415 Volts, 630 Amps, 50 Hz, conforming to IS/IEC 60898, with Thermal Magnetic release, overload, short circuit fault protection 3 phase, breaking capacity 50 KA, Ics=100% of Icu, with Spreader terminal of both ends, connecting and testing, complete all as specified and as directed by Engineer-in-charge. |
| 29 | All as per Item No. 28 here-in-above, but for 350 Amp capacity MCCB, breaking capacity 36 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge. |
| 30 | All as per Item No. 28 here-in-above, but for 250 Amp capacity MCCB, breaking capacity 36 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge. |
| 31 | All as per Item No. 28 here-in-above, but for 200 Amp capacity MCCB, breaking capacity 36 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge. |
| 32 | All as per Item No. 28 here-in-above, but for 160 Amp capacity MCCB, breaking capacity 36 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge. |
| 33 | All as per Item No. 28 here-in-above, but for 100 Amp capacity MCCB, breaking capacity 30 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge. |
| 34 | All as per Item No. 28 here-in-above, but for 63 Amp capacity MCCB, breaking capacity 30 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge. |
| 35 | Labour only for taking out of unserviceable ACB (Air Circuit Breaker) of 800 Amps, 415 Volts, 50Hz from the panel and servicing, repair/ replacement of unserviceable spare parts and rack in at the same position after repair including testing the ACB, complete all as specified and as directed by Engineer-in-charge. NOTE- Spare parts shall be measured and paid separately under respective item as Supply Only. |
| 36 | Supply only UV release for 800 Amp ACB |
| 37 | Supply only Shunt Coil for 800 Amp ACB |
| 38 | Supply only Closing Coil for 800 Amp ACB |
| 39 | Supply only normal type relay for 800 Amp ACB |
| 40 | S&F in-repair of Aluminium strip of 25 x 3.15mm with saddles and fixing screws etc. as earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and as directed by Engineer-in-charge. |
| 41 | S&F in-repair of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, complete all as specified and as directed by Engineer-in-charge. |
| 42 | S&F in-repair of Air termination, single pointed, copper rod 12mm dia and 300mm long with and including necessary base and insulator, complete all as specified and as directed by Engineer-in-charge. |
| 43 | Supply, installation, testing and commissioning in-replacement of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Panel Board of size 1100 X 1000 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding mounted on DMC insulator and suitable for 400 Amps with main indication IA - 03 Nos (Make- L&T/ Siemens/ Schneider/ Legrand), Digital ammeter 0-500 Amps with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand), digital voltmeter of 500Volts with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand) and LED/ Neon type indicating lamps panel mounting type RYB-3 Nos (Make- L&T/ Siemens/ Schneider/ Legrand), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following :-(a) Internal wiring with 6sqmm single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.(b) Fine wiring with 1.5sqmm single core copper conductor cable for instruments/indicating lamps-1 Job. (c) Bus bar chamber comprising 04 Nos aluminium strip bus bar mounted on DMC (Dough Moulding Compound) insulator and PVC sheathed of capacity 400 Amps with colour coding for RYB & N - 01 SetINCOMING(d) MCCB 125 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. OUT GOING(e) MCCB 100 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. (f) MCCB 63 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. (g) MCB Single Pole & Neutral (SPN) 32 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-06 Nos. (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication). |
| 44 | Supply, installation, testing and commissioning in-replacement of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Panel Board of size 9000 X 800 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 200 Amps with colour coding mounted on DMC insulator and suitable for 200 Amps with main indication IA - 03 Nos (Make- L&T/ Siemens/ Schneider/ Legrand), Digital ammeter 0-500 Amps with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand), digital voltmeter of 500Volts with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand) and LED/ Neon type indicating lamps panel mounting type RYB-3 Nos (Make- L&T/ Siemens/ Schneider/ Legrand), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following :-(a) Internal wiring with 6sqmm single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.(b) Fine wiring with 1.5sqmm single core copper conductor cable for instruments/indicating lamps-1 Job. (c) Bus bar chamber comprising 04 Nos aluminium strip bus bar mounted on DMC (Dough Moulding Compound) insulator and PVC sheathed of capacity 200 Amps with colour coding for RYB & N - 01 SetINCOMING(d) MCCB 63 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 16KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. OUT GOING(e) MCB Triple Pole & Neutral (TPN) 40 Amp, 'C' Curve, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 No.(f) MCB Triple Pole & Neutral (TPN) 25 Amp, 'C' Curve, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 No. (g) MCB Single Pole & Neutral (SPN) 40 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 Nos.(h) MCB Single Pole & Neutral (SPN) 25 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-03 Nos. (j) MCB Single Pole & Neutral (SPN) 10 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 Nos. (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication). |
| 45 | Supply, installation, testing and commissioning in-replacement of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Panel Board of size 1100 X 1000 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 630 Amps with colour coding mounted on DMC insulator and suitable for 630 Amps with main indication IA - 03 Nos (Make- L&T/ Siemens/ Schneider/ Legrand), Digital ammeter 0-500 Amps with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand), digital voltmeter of 500Volts with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand) and LED/ Neon type indicating lamps panel mounting type RYB-3 Nos (Make- L&T/ Siemens/ Schneider/ Legrand), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following :-(a) Internal wiring with 6sqmm single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.(b) Fine wiring with 1.5sqmm single core copper conductor cable for instruments/indicating lamps-1 Job. (c) Bus bar chamber comprising 04 Nos aluminium strip bus bar mounted on DMC (Dough Moulding Compound) insulator and PVC sheathed of capacity 630 Amps with colour coding for RYB & N - 01 SetINCOMING(d) MCCB 800 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 50KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication). |
| 46 | M&L for preparing old rusted steel surfaces of LT panel board by means of sand paper, making free from rust and other foreign particles and appying two coats of synthetic enamel paint by sprey paing of existing colour, complete all as specified and as directed by Engineer-in-charge. (NOTE- Necessary protection cloth and protective measures shall be arranged by contractor's own arrangement at his own cost to avoid any accident.) |
| 47 | S&F in-repair of cable route indicator made of cast iron, suitable for LT cable with 35x35x4mm thick MS angle iron post of 1.0m long embedded in PCC 1:3:6 type C-1 (20mm graded aggregates) as in bed block of 150x150x300mm deep, complete all as specified and as directed by Engineer-in-charge. |
| 48 | S&F in-repair of APFC relay of 08 steps and of size 96x96 mm suitable for upto 50KVAR APFC panel, complete all as specified and as directed by Engineer-in-charge. |
| 49 | S&F in-repair of CT coil 100/5 suitable for upto 50KVAR APFC panel, complete all as specified and as directed by Engineer-in-charge. |
| 50 | S&F in-repair of indicator lamps 22.5mm suitable for APFC panel, complete all as specified and as directed by Engineer-in-charge. |
| 51 | S&F in-repair of MOC 12.5 contractor 240 Volts, suitable for APFC panel, complete all as specified and as directed by Engineer-in-charge. |
| 52 | M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized 32x6mm GI earth strip by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 40 mm bore( light grade) and watering pipe 20 mm bore GI pipe (medium grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down existing damaged one, complete all as specified & testing on completion. NOTE:- (i) Item includes the cost of 1.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr GI earth wire. |
| 53 | Comprehensive maintenance and general servicing, cleaning, Greasing, Minor repairs to Diesel Engine sets including oil pump, water pump, adjustment of tappets, minor repairs of self starter and dynamo, repair of radiator with cleaning, repair to generator control panel by replacement existing burnt out of copper wire including repair/ replacement of toggle switches and replacement of spares all gasket and joints etc for DG set of capacity 10 to 30 KVA to the entire satisfaction by the Engr-in-Charge. Note : Spare parts will be measured and paid separately under respective items. |
| 54 | All as per serial item No 53 above but for 40 to 75 KVA DG Set complete. |
| 55 | Repair/overhauling /Calibration of fuel injection pump and nozzle with holder assembly of diesel engine including providing new parts such as delivery valves. Elements, tapet gear, plungar , nozzle copper washes, leak off pipes, banzo bolts, service kit, governer repair etc in replacement of existing UNSV Parts including re-assembiling, setting , fixing and testing at site suitable of 10 KVA to 30 KVA DG set. |
| 56 | All as per serial item No 55 above but for 40 to 75 KVA DG Set |
| 57 | Repair / Replacement of safety devices complete unit for DG set (water temperature meter, Hour Meter, oil pressure meter, water temperature sensor, Low pressure sensor, vacuum indicator) (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) for following DG sets :- (a) 10KVA to 30 KVA |
| 58 | (b) 40 KVA to 75 KVA |
| 59 | Supply and fix in repair of following spares parts against BOQ sl item 72 (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) for 10 to 30 KVA capacity DG Sets :- (a) Diesel Filter element with clamp and nut-bolt |
| 60 | (b) Mobile Filter element with clamp and nut-bolt |
| 61 | (c) Air Filter element with clamp and nut-bolt |
| 62 | (d) Set of high pressure pipe |
| 63 | (e) Thermostat |
| 64 | (f) Cooling water pipe |
| 65 | (g) set of hoses |
| 66 | (h) set of hose clip |
| 67 | (j) Set of flexible fuel pipe |
| 68 | (k)Set of anti vibration rubber coupling bushes with stud bolts and nuts |
| 69 | (l) Head Gasket |
| 70 | (m) Head Gasket Set |
| 71 | (n) Fly wheel side oil seal |
| 72 | (o) Fly wheel ring gear |
| 73 | (p) STR Relay Board |
| 74 | (q) RRA |
| 75 | (r) Controller board (Conservation Kit) |
| 76 | (s) Stop solenoid |
| 77 | (t) Temp Sensor switch |
| 78 | Supply and fix in repair of following spares parts against BOQ sl item 72 (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) for 40 to 75 KVA capacity DG Sets :- (a) Diesel Filter element with clamp and nut-bolt |
| 79 | (b) Mobile Filter element with clamp and nut-bolt |
| 80 | (c) Air Filter element with clamp and nut-bolt |
| 81 | (d) Set of high pressure pipe |
| 82 | (e) Thermostat |
| 83 | (f) Cooling water pipe |
| 84 | (g) set of hoses |
| 85 | (h) set of hose clip |
| 86 | (j) Set of flexible fuel pipe |
| 87 | (k)Set of anti vibration rubber coupling bushes with stud bolts and nuts |
| 88 | (l) Head Gasket |
| 89 | (m) Head Gasket Set |
| 90 | (n) Fly wheel side oil seal |
| 91 | (o) Fly wheel ring gear |
| 92 | (p) STR Relay Board |
| 93 | (q) RRA |
| 94 | (r) Controller board (Conservation Kit) |
| 95 | (s) Stop solenoid |
| 96 | (t) Temp Sensor switch |
| 97 | Supply and fix in repair V belt for any drive suitable for DG set capacity 10 to 160 KVA complete all as specified and as directed. |
| 98 | Repairs/replacement to exhaust manifold (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) by replacement of worn out silencer unit of required size and shape suitable for DG set 10 KVA to 30 KVA complete all as specified and directed. |
| 99 | Cleaning of fuel tank of any capacity by draining out diesel and cleaning internally with the help of cleaning agent and compressed air , drain out the sludge/foreign matter deposited inside the diesel tank of any capacity of DG set from 10 to 30 KVA capacity |
| 100 | All as per item 99 here in before but suitable for DG set capacity 40 KVA to 75 KVA complete. |
| 101 | Removing existing unserviceble battery and supplied and fixed new lead acid battery maintenance free 12 volts upto 180AH fully charged as required on site with matching capacity of Dg set complete all as directed. (Make- Exide/ Luminious/ as existing) |
| 102 | Taking out old unserviceable battery charger and supply and fix battery charger (MAKE- Exide/ Luminous/ as existing) suitable for charging lead acid battery 6/12volt boost and trickle charging mode, 230 volt single phase complet with charging lead connecting clip complete all as specified and as directed. |
| 103 | M&L for replacement of lubrication oil 20W40, (MAKE- Castrol/ Servo/ Shell) in DG sets of capacity 10 to 160 KVA all as specified and directed. |
| 104 | S&F in-repair of coolent for radiator of water cooled engines as per manufacturers recommendation complete as all directed. |
| 105 | Replacement and Repair of self starter (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) 12 volts for 10 to 30 KVA DG set by replacing the defective worn out parts such as armature, field coil, bendex pinion, clutch plate, solinoid switch and any other necessary parts including testing complete. |
| 106 | All as per serial item No 105 above but for 40 to 75 KVA capacity DG Set. |
| 107 | Taking out radiator assy and repair by cleaning washing flushing and removing blockage of chocked tubes including replacement of existing UNSV water tube soldering nuts bolts washers and making leakproof and testing at site of 10 to 30 KVA DG Set. |
| 108 | All as per serial item No 107 above but for 40 to 75 KVA capacity DG Set. |
| 109 | Replacement of battery copper leads 2 meter long of suitable size single core with copper thimble complete. |
| 110 | Replacement of battery terminals brass of any capacity battery complete. |
| 111 | Repair to alternater complete by dismantling and cutting winding, cleaning, polishing, welding work and re-winding with suitable size and gauge of copper enamelled winding wire complete greasing, replacement of carbon brush, varneshing etc and testing after repair of 10 to 30 KVA DG Set including testing after repair complete all as specified and directed. |
| 112 | Taking out Dynamo 12 V for complete repair including providing new parts such as armature, brushes, filed coil , bush bearings,cut out, bearing, pully nut, bolts & washer etc in replacement of exisitng UNSV Parts refixing and testing at site of 10 to 30 KVA DG Set. |
| 113 | All as per serial item No 112 above but for 40 to 100 KVA capacity DG Set. |
| 114 | Supply only distilled water for lead acid cell 12 Volt complete. |
| 115 | Supply and replacement of Automatic Voltage Regulator suitable for DG sets of Capacity 10 to 75 KVA. |
| 116 | M&L for topping up of transformer oil of dielectric strength more than 50KV in servo voltage stabilizer all as specified and directed. |
| 117 | Disconnecting AC supply,dismantling, taking down and opening Servo stabilizer having capacity 20 KVA to 500KVA. Servicing, repair/replacement unserviceable parts such as contact bush, mechanical tap moving system, filtration of oil, topup new oil, servo motor, carbon busher assembly with carbon and repair/maint/replacement of PC board, indicator, transformer etc and other minor parts found defective during repairing. Re-assembling the same after repairing and commissioning testing, complete all as per specified and as directed by Engineer-in-charge.NOTE :- Parts replaced of voltage stabilizer shall be measured and paid separetly under respective items. (MAKE of spare parts- Havells/ L&T/ Siemens/ as existing) |
| 118 | (a) Replacement of inducator of different colour |
| 119 | (b) Replacement of low cut switch of existing size & capacity |
| 120 | (c) Replacement of high cut switch of existing size & capacity |
| 121 | (d) Repair/replacement R C network suitable size & capacity or as per existing. |
| 122 | (e) Repair/replacement carbon set suitable size & type or as per existing. |
| 123 | (f) Repair/replacement carbon bush suitable size & type or as per existing. |
| 124 | (g) Repair/replacement/rewinding dimmer suitable size & capacity or as per existing. |
| 125 | (h) Repair/replacement/rewinding buckbook transformer suitable size & capacity or as per existing. |
| 126 | (j) Repair/replacement copper lugs of suitable size or as per existing size. |
| 127 | (k) Repair/replacement PCB (printed circuit board) of suitable size & capacity or as per existing. |
| 128 | (l) Repair/replacement PCB connector of suitable size & capacity or as per existing. |
| 129 | (m) Repair/replacement synchronize motor of suitable size & capacity or as per existing. |
| 130 | (n) Repair/replacement triger transformer of suitable size & capacity or as per existing. |
| 131 | (o) Repair/replacement of digital conductor of suitable size & capacity or as per existing. |
| 132 | (p) Repair/replacement digital volt meter. |
| 133 | Dismantling unserviceable turbo charger from DG set of capacity upto 160 KVA complete and supply and fix new turbo charger as per manufacturer's recommendataion all as specified and directed. |
| 134 | S&F in repair Single Phase Contactor Type MR high AC -1 rating all as specified and directed. |
| 135 | S&F in repair relay siutable fo upto 75 KVA DG set/ servo stabilizer all as specified and directed. |
| 136 | S&F in repair 3 Phase LED Ammeter CL-1 flush mounting with inbuild selector switch and CT all as specified and directed by Enfr-in-Charge. |
| 137 | S&F in repair 3 Phase LED voltmeter CL-1 flush mounting with inbuild selector switch and CT all as specified and directed by Enfr-in-Charge. |
| 138 | Supply and fix Emegency push button for upto 160 KVA DG set all as per manufacturer recommendation and directed by Engr-in-Charge. |
| 139 | S&F in-repair of On load Changeover Switch with sheet metal enclosure and advanced neutral switch, Four Pole (FP), 63 Amps, 415 Volts, conforming to IS/IEC 60947-3 with and including all accessories (side handle), connecting up and re-fixing of cables with proper lugs, complete all as specified and as directed by Engineer-in-charge. |
| 140 | All as per Item No. 139 here-in-above, but for 100 Amp capacity Changeover Switch, complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information |